SKG W7 Lower Back Massager Instruction Manual

June 4, 2024
SKG

SKG W7 Lower Back Massager

Operating instructions

Number

| Light status| Status description
---|---|---

1

| Blue light stays ON (on for 5 seconds and then go out)| Turn on (when the battery is sufficient)

2

| Blue light flashes (on for 5 seconds and then go out)| When the machine is turned on (with sufficient power) adjust the massage/hot compress levelc

3

| Orange light stays on (on for 5 seconds and then go out)| When the battery is low

4

| Orange light flashes (on for 5 seconds and then go out)| When the machine is turned on (the battery is insufficient) adjust the massage/hot compress level

5

| Orange light flashes| Charging

6

| Blue light flashes| Fully charged

In addition to t he light reminder during operation, the main control box also has a vibration reminder.

  1. There will be a long vibration when turning on/off
  2. There will be one short vibration when adjusting the intensity gear, and two consecutive short vibrations will occur when the device is adjusted to the highest or lowest gear.
  3. When adjusting the gear of hot compress, one short vibration will occur when set the heat compress to the low level, 2 continuous short vibrations when set to the middle level, and 3 continuous short vibrations when set to the high level, and a long vibration will occur when the hot compress is turned off.
  4. When successfully connected to the phone APP, the blue indicator light will flash twice and the product vibrate once for reminding. When disconnected, the blue indicator light will flash twice, and a long vibration will occur for reminding.

Use “Future Wear”(SKG) APP for control

To freely experience more massage techn iques and intelligent control technology.

1. Use WeChat to scan the QR code on the right or search for “Future Wear” (5KG) in the mobile application market, download the APP and install it

2. Register/Login
Enter the mobile number and get the SMS verification code to complete the registration

3. Add device
Make sure that the Bluetooth of the mobile phone is turned on and the SKG device is turned on Click “Add Device” on the APP homepage

Precautions for disposal of wastes

Please do your part in recycling the rechargeable batteries (lithium-ion batteries)

| The battery in this product is a dedicated rechargeable battery, which is not intended for other products. Please do not charge the removed rechargeable battery.

  • Do not throw it in the fire, or heat it up to high temperature
  • Do not pierce it with nails, impact it by gravity or decompose it for modification
  • Do not connect the positive and negative poles of the battery directly with metal
  • Do not store it together with necklaces, hairpins, etc.
  • Do not charge, use or store it in high-temperature places such as near the stove or in sunlight. The above conditions can cause overheat, fire and breakage of the battery.

---|---
| Keep the removed rechargeable battery out of the reach of infants and young children in case that it is swallowed by mistake

  • When the device is mistakenly swallowed, please consult a doctor immediately
  • When the battery fluid leaks, do not touch the fluid by hand, and it can be processed in the following way
  • When the battery liquid splashes into eyes, there is a danger of blindness. Do not rub eyes directly with your hands. Immediately wash eyes with clean water and consult with a doctor; when the battery liquid splashes onto the body or clothes, it may cause skin irritation or injury. Please rinse it with clean water. If you still feel discomfort, immediately see the doctors
  • Only the scrapped products can be decomposed. Otherwise, the accident of fire, e lectric shock, injuries may be resulted in. When you need to repair the battery (not to replace the battery), please consult the dealer where you purchased this product

The lithium-ion battery in this product is a valuable resource that can be recycled and reused, which is not allowed to be replaced. Please hand it over to a professional agency that can recycle the rechargeable batteries when this product is scrapped. Before scrapping this product, remove the battery from this appliance. Before removing the battery, the appliance must be powered off. The battery should be disposed of safely, which can be taken out in the steps below:

  1. With professional tools, open the upper and lower cases.
  2. Remove the circuit board and the motor.
  3. Take out the battery, cut the battery wire with professional pliers, and then take out the battery.

Daily maintenance of the instrument

① Turn of

② Remove the main control box

③ Wipe the electrode  pads with a wet tissue (If necessary, soak in water a nd wash, then dry)

④ Storage

The basic parameters of the product

Product name SKG Massage Belt Charging input 5V:=
Model W7 Rated input power 10W
Battery capacity 2000mAh Charging port Type-C
Executive standard G84 706.1-2005 GB4 706.1 0-2008
  • The model approval code of the product is presented as”laser engraving product nameplate”.b
Wear Future Technologies Co., Ltd.

Address: 23AF, Building Ill, Zhongke R&D Park, 009 High-tech South Avenue I, High-tech Zone Community, Yuehai Sub-district Office, Nanshan District, Shenzhen, Guangdong Province Website : www.skg.com
If you have any questions, please feel free to send a mail: [email protected]

Precautions

DANGER
Please be careful NOT to use the product together with the following medical electronic equipment to avoid mutual influence and cause injury
– Implanted medical e lectronic devices such as pacemakers
– Medical electronic devices for life support such as artificial heart and lungs
– Electrocardiograph and other medical e lectronic instruments
It’s prohibited to be used in gas stations, high dust workshops, gas stations and other combustible and explosive places

Warning

  • Provided that the patient simultaneously uses high-frequency surgical equipment and massage device his/her on the body, it may burn the electrode sheet of the massage  device, or damage the massage device.
  • In case that the user utilizes the product near shortwave or microwave therapeutic equipment (1 meter), the output of this massager may be unstable
  • Avoid contacting wounds and scars with electrode sheet during massage
  • During massage, be sure not to place the electrode sheet near the chest and heart, otherwise it’ ll increase the risk of heart fibrillation
  • It’s recommended that one user should use this product, other users shall clean the electrode sheet on the product before using
  • When using the product, the user shall closely attach the electrode sheet to the skin to evenly contact
  • The product’s electrode sheet feature a heating function, when enabling the heating function, it may cause low-temperature burns if using the heating function for a long time (over 20 minutes) on the same part.
  • If the user feels uncomfortable during or after use, it’s recommended to stop using and seekmedical advice
  • Since this product contains lithium batteries, be sure not to separately dismantle, modify, immerse the product in water or throw it into the fire, otherwise it may cause product damage and explosion
  • Avoid using it near the heart, above the neck, head, mouth, private parts, or parts with skin diseases, and avoid simultaneously massaging the soles of both feet
  • Besides, be sure not to compress the internal organs when using it. Otherwise, it may cause accidents or physical discomfort
  • Avoid using this product with other medical equipment or over 2 sets of this product, otherwise the user may feel nausea or physical discomfort
  • Avoid using for purposes other than the massage recorded in the  instruction manual, otherwiseit may cause accidents and breakdown
  • Avoid using the electrode sheet with chipped or damaged surfaces, or it may cause accidents and malfunctions
  • Avoid disassembling, repairing or modifying this product without permission, otherwise it may cause malfunction or electric shock accident

In the following conditions, please consult a doctor before using this product.
Otherwise, it may cause accidents or physical discomfort:

  • Patients receiving the medical treatment and feeling physical discomfort
  • Patients with heart and cranial nerve abnormities
  • Patients whose body temperature exceeds 38 degrees (stage of fervescence)
  • People whose skin is sensitive to graphene/graphite
  • Patients with infectious diseases
  • Patients infected with skin perceptual disturbance or skin abnormalities
  • Patients who are taking medication
  • Patients with abnormal blood pressure
  • Patients failing to express their wishes freely

In the following conditions, please consult a doctor before using this product.
Otherwise, it may cause accidents or physical discomfort:

  • Malignant tumor patient
  • Patients with hemorrhagic tendency
  • Patient with coagulation disorders
  • Pregnant women and puerpera
  • Patients with acute purulent inflammation
  • Patient with convulsion stage after cerebrovascular accident
  • Cardiac pacemaker user
  • Patients with metal implants
  • Patient with severe cognitive impairment
  • Near the human’s heart
  • Patients with unconsciousness, deformity of limb bone and joint contracture
  • Spastic paralysis
  • Eye
  • atient with abnormal nervous irritability

Note

  •  Please read the product manual before using
  • If the user feels uncomfortable due to an abnormality in this product, please stop using it immediately. If the user feels that there exist body or skin abnormities, please seek medical advice and follow the doctor’s advice
  • During the massage, if one wants to move the electrode sheet or move to other people’s body, make sure to power off before moving, or it may cause strong electric shock
  • Patients with a history of cerebrovascular accidents, avoid placing the e lectrode pair on the craniocerebral part
  • Do not massage carrying an electronic device. Otherwise, the electronic device may be misoperated (e.g.: disorder in electronic watch)
  • In case of abnormal operation, please cut off the power supply immediately, otherwise high temperature or short circuit or accident may occur. Contact the customer  service personnel for after-sales consultation simultaneously.
  • Do not plug the USB charging cable with a wet hand, otherwise it may cause an electric shock or accident
  • Please keep it away from children or people without expressible conscious, otherwise it will cause accidents or physical discomfort.
  • Do not use it in high humidity places such as the bathroom, or use the product while bathing, otherwise there may be a strong electric shock and damage to the product.
  • Do not use it in bed, otherwise the ontology may be damaged. In addition, the electrode sheet may be moved to other parts to cause physical discomfort.
  • Do not use it when driving a car, otherwise it may cause physical discomfort due to excessive stimulation, resulting in an accident.
  • Do not stick the electrode sheet to the affected area for a long time, otherwise it may cause skin inflammation.
  • During massage, do not allow the metal part of belts, necklaces and other items to contact the electrode sheet, otherwise it may be strongly shocked.
  • When using the massage function, do not use it in the same place for a long time (more than 30 minutes), otherwise the muscle fatigue in the massage part may cause physical discomfort.
  • Please wear the product correctly (bilateral symmetry at back), otherwise, it  may cause accidents or physical discomfort.