K2 Systems 5105 Non Metal Flashings Traditional Metal Flashings Instruction Manual
- June 2, 2024
- K2 Systems
Table of Contents
- 5105 Non Metal Flashings Traditional Metal Flashings
- Specifications
- Product Information
- General Safety Information
- Tools Overview
- Splice Foot X & XL Dimensions
- Components
- Assembly
- Bonding and Grounding
- Fire Rating
- Compatible Modules
- Q: Can the Splice Foot X and XL be used with any PV
- Q: What should I do if I encounter corrosion on the
- Q: How often should I review the installation
5105 Non Metal Flashings Traditional Metal Flashings
“`html
Specifications
- Product Name: Splice Foot X and XL
- Manufacturer: K2 Systems (formerly Everest Solar Systems)
- Website: k2-systems.com
Product Information
General Safety Information
Please note that the general mounting instructions must be
followed at all times. The equipment should only be installed and
operated by qualified and trained installers. It is important to
ensure compliance with on-site static loading requirements and roof
load-bearing capacity for roof-mounted systems.
Tools Overview
The necessary tools for installation will be detailed in the
manual. Make sure to have all required tools ready before starting
the assembly process.
Splice Foot X & XL Dimensions
The manual provides detailed dimensions for the Splice Foot X
and XL components to aid in the assembly process.
Components
The manual lists all components included in the Splice Foot X
and XL kit for easy identification during assembly.
Assembly
Follow the step-by-step assembly instructions provided in the
manual to correctly install the Splice Foot X and XL components.
Make sure to adhere to the manufacturer’s guidelines for proper
installation.
Bonding and Grounding
Proper bonding and grounding procedures are crucial for the safe
and effective operation of the PV system. Follow country-specific
standards and regulations for equipotential
bonding/grounding/earthing between individual parts.
Fire Rating
Ensure that the components used in the PV system meet required
fire safety standards as outlined in the manual.
Compatible Modules
Refer to the list of compatible modules provided in the manual
to ensure proper integration with the Splice Foot X and XL
components.
FAQ
Q: Can the Splice Foot X and XL be used with any PV
system?
A: The Splice Foot X and XL are designed to support PV systems;
however, it is important to check compatibility with specific
modules and mounting configurations.
Q: What should I do if I encounter corrosion on the
components?
A: Carefully inspect all components for corrosion exposure and
replace any affected parts with appropriate corrosion-resistant
alternatives as necessary.
Q: How often should I review the installation
instructions?
A: Prior to installation, consult the manufacturer’s website for
up-to-date instructions, as the installation process may change
over time.
“`
We support PV systems
Formerly Everest Solar Systems
Splice Foot X and XL
INSTALLATION MANUAL
k2-systems.com
Content
T General Safety Information
3
· Roof requirements
4
· Structural requirements
4
· Important mounting instructions
4
T Tools Overview
5
T Splice Foot X & XL Dimensions
6
T Components
8
T Assembly
10
T Bonding and Grounding
16
T Fire Rating
17
T Compatible Modules
18
T Notes
22
Quality tested several certifications
K2 Systems stands for secure connections, highest quality and precision. Our
customers and business partners have known that for a long time. Independent
institutes have tested, confirmed and certified our capabilities and
components. Please find our quality and product certificates under:
k2-systems.com/en-US/company/quality-management-and-certificates
2
General Safety Information
Please note that our general mounting instructions must be followed at all times and can be viewed online at https://k2-systems.com/en- US/downloads/documentation
T The equipment may only be installed and operated by qualified and adequately
trained installers.
T Prior to installation, ensure that the product complies with on-site static
loading requirements. For roof-mounted systems, the roof load-bearing capacity
must always be checked.
of 25 years! We strongly recommend reviewing our terms of guarantee, which can
be viewed at https://k2-systems.com/ en-US/downloads/documentation. We will
also send this information on request.
T Dismantling of the system is performed in reverse order to the assembly.
T National and local building regulations and environmental requirements must
be adhered to.
T Compliance with health and safety regulations, accident prevention
guidelines and applicable standards are required. · Protective equipment such
as safety helmet, boots and gloves must be worn. · Roofing works must be in
accordance with roofing regulations utilizing fall protection safeguards when
eaves height exceeds 3 m. · At least two people must be present for the
duration of the installation work in order to provide rapid assistance in the
event of an emergency.
T K2 mounting systems are continuously developed and improved and the
installation process may thereby change at any time. Prior to installation
consult our website at: https://k2-systems.com/en-US/downloads/documentation
for up-to-date instructions. We can send you the latest version on request.
T The assembly instructions of the module manufacturer must be adhered to.
T Equipotential bonding/grounding/earthing between individual parts is to be
performed according to country specific standards, as well as national laws
and regulations.
T K2 stainless steel components are available in different corrosion
resistance classes. Each structure or component must be carefully checked for
possible corrosion exposure.
T The installer is solely responsible for:
T Handling and installing the PV modules and rail system according to the
manufacturer’s instruction, with special attention for the suggested clamping
locations on the frame. attention for the suggested clamping locations on the
frame.
T Complying with all applicable local or national building codes, standards
and industry best practices including any code that may supersede this manual.
T Ensuring that K2’s and other products are appropriate for the specific
installation and the installation location.
T Using only K2 parts and installer-supplied parts as specified by K2.
(Substitution of parts may void the warranty and invalidate the letters of
certification.)
T Verifying the strength of any alternate mounting devices used in lieu of the
anchoring screws.
T Ensuring safe installation of all electrical and mechanical aspects of the
PV array.
T At least one copy of the assembly instructions should be available on site
throughout the duration of the installation.
T Failure to adhere to our general safety and assembly instructions and not
using all system components, K2 is not liable for any resulting defects or
damages. We do not accept liability for any damage resulting in the use of
competitor’s parts. Warranty is excluded in such cases.
T If all safety instructions are adhered to and the system is correctly
installed, there is a product warranty entitlement
T Ensuring correct and appropriate design parameters are used in determining
the design loading used for design of the specific installation. Parameters,
such as snow loading, wind speed, exposure and topographic factor should be
confirmed with the local building official or a licensed professional
engineer.
T K2 recommends inspecting installed racking system periodically for loose
components, loose fasteners and any corrosion.
3
The following guidelines apply
The CrossRail System can be installed as standard under the following
conditions. Even if the system is capable of meeting higher demands through
the integration of safety standards, please get in touch with your contact at
K2 Systems if the specified values are exceeded.
Roof Requirements
T The sufficient holding force of the roof covering at the support or
substructure must be ensured on site.
T Roof pitch: 0 – 75°
T For low slope roofs, make sure there is positive drainage and roofing is
compatible with butyl.
Structural Requirements
The static verification of the component is automatically calculated with the
K2 Base planning software for the respective location. The design provided in
a project report must be followed.
Ensuring that the roof, its rafters, connections, and other structural support
members can support the array under all code level loading conditions.
Important Mounting Instructions
!T Maintaining the waterproof integrity of the roof. To maintain the flashing
performance, avoid installation when the temperature of the roof and butyl are
below 22F or above 176F. K2 EverSeal must be installed on a dry surface.
T Thermal break must be determined by the installer based on the rail system
installation instructions. The installer must also determine the maximum
allowed span and cantilever design parameters recommended by the rail system
manufacturer. The Splice Foot X/XL can be installed on steep slope roofs
(composite shingles). The K2 EverSeal is also compatible with felt and
synthetic underlayments.
Moisture Content
T The K2 EverSeal is to be installed on dry mounting surfaces.
T Determining how wet is too wet: First, remove the paper backing from a
Splice Foot X/XL exposing the clean butyl. Second, press the base, K2 EverSeal
side down against the surface. Third, pick up the base. If the base adheres to
the roof, the roof is suitably dry for installation.
T A heat gun, roof dryer, calcium chloride or alcohol is suitable to remove
ice from the roof surface.
Periodical Inspection
T K2 recommends inspecting installed racking system periodically for loose
components, loose fasteners and any corrosion. If found, those components are
to be retightened, or replaced immediately.
T When a PV module needs to be removed from the PV array for maintenance
and/or replacement, the electric bonding system may need to be temporarily
restored to maintain the electrical bonding path. Please make sure the system
electrical circuits and disconnects are in the open position and the entire
system is powered down. Cover the fronts of modules in the array with an
opaque material to stop the production of electricity. Use appropriate safety
equipment such as insulated tools and insulating gloves to protect yourself.
4
Tools Overview
Chalk Line 3.0 m
Tape Measure
6.0 m
Drill
Torque Wrench 6 – 35 Nm
(4.5 – 22.2 lb-ft)
13mm Socket
1/4″ Nut Driver
Sealant Gun
Heat Gun
Compatible Sealants
T Henry : 208R, 209, 925 (Black) T Geocel: S2, S4 (Black) T Sashco: Through the Roof T Boss: 125 (Black)
T Top Industrial: Rain Buster 850, 900 T Chem Link: M1 T NPC Solar Seal 900 T GE All Purpose 100% Silicone
Torque Overview
T M10 T-Bolts: 25.8 ft-lb (35 Nm)
Technical Note
T Proper torque values for a wood screw will vary depending on the rafter
and/or deck characteristics; hardness, age, and moisture of the wood. Tighten
the splice foot screws until the conical washer stops rotating.
T Stainless hardware is soft and if dry torqued too quickly it may cause the
nut and bolt to seize.
T K2 Systems recommends all stainless steel threads be lubricated. This will
make it easier to tighten nuts to bolts, avoid galling, and facilitate
adjustments before the nut is properly torqued. Therefore, avoid the use of an
impact driver.
Tools and materials for the installation of third party items such as roof attachment products, roof covering and sealing products or items used for bonding and grounding are not listed here. Please refer to the instructions of those third party products.
5
Splice Foot X
Units: [in] mm
6
Splice Foot XL
2X
.18
Units: [in] mm
4.50
.81 20.60
4x .59 15
4X 1.41 35.80
.98 25
.18 4.50 3.50 88.90
4.00 101.60
6X .24
6
2X .44 11.10
2.68 68
TION CONTAINED IN THIS DRAWING IS THE SOLE PROPERTY OF K2 SYSTEMS. UCTION IN PART OR AS A WHOLE WITHOUT THE WRITTEN PERMISSION OF K2 SYSTEMS IS PROHIBITED.
TOLERANCES
DIMENSION X. X.X X.XX RADIUS ANGULAR
TOLERANCE(mm) ±1.00 ±0.40 ±0.20 ±0.5 ±1º
THIRD ANGLE
Name Drawn
Checked
Date
K2 Systems
Title:
2835 La Mirada Dr Suite A Vista, CA 92081
phone 760.301.5300
4 Material: Weight per length: 2.2618kg/m
Size:
B
1.5198 lbs/ft
Splice Foot XL,
Drawing no. (ESS):
1065 -02
Part no.
Approved
Weight per cut: 229.7948 g
0.5066 lbs Mfg. Process: EXTRUSION
Finish: MILL
Last Revision
Part Weight:
219.8257 g
0.484496 lbs Scale:
1:2
Revision:
02
This drawing is the sole property of K2 Systems. It is protected by copyright and may only be copied, reproduced or distributed to a third party with e
7
4
1 4000113 / 4000162 Splice Foot X / Splice Foot XL
8
2 4000115 Self-tapping screw with sealing washer
3 2 1
3 4000601-H, 4000602-H
4 4000090 / 4000050-H
5 4000019, 4000020
Mid Clamp 30 – 50 mm module frame height
End Clamp or Yeti Clamp 30 – 50 mm module frame height
CrossRail 44-X shown & PNs listed
9
Assembly
Part A: Marking the array and mounting locations
1
! Corner out and mark array on roof. Snap chalk lines for rail location within
shingle course. (Refer to module manufacturer frame clamping zones). Mark
mounting locations over rafters and chalk lines within shingle course. Refer
to engineering letters for allowable mount spacing. It is best practice to
stager mounts.
2
! Line up mounts on chalk line.
10
Part B: Mount Placement and Installation for Rafter Connection
To maintain flashing performance, avoid installation when the temperature of
the roof and/or butyl is below 22F or ! above 176F. K2 EverSeal must be
installed on a dry surface.
1
! Locate the rafter and clean roofing surface for mount placement. Peel back
protective paper from butyl, and stick down mount on a single shingle course
with the two center holes lining up over the rafter. Position all mounts in
the same direction with the long side towards the ridge. Drive provided lag
screws into the rafter until the conical washer stops rotating, providing a
positive seal. Do not over torque. It should be tightened until the conical
washer stops rotating.
2 ! The distance from the edge of the rafter and the wood screws must be at
least 5/16″ from the edge.
NOTE: Minimum Edge Distance = 1.5D Where D is the diameter of the screw. NOTE:
The screw shall hit the area that is marked by the red box.
5/16″ min.
5/16″ min.
11
3 Modified Rafter
! If the screw hits a nail under the shingle, there are a few solutions: 1.
Leave the nail and use the rest of the holes if possible 2. Remove the nail 3.
Angle the driver to avoid the nail
Part C: Mount Placement and Installation for Deck Connection
! To maintain flashing performance, avoid installation when the temperature of
the roof and/or butyl is below 22F or above 176F. K2 EverSeal must be
installed on a dry surface.
1
! For deck attachments, follow steps in B2, but only use Splice Foot screws in
the four corners of the mount. When possible always attach mounts to the
rafter and only use deck attached as a secondary option when rafters are not
within mounting zones for the array. Follow K2 engineered calculations and
span charts for deck attachments. Ensure that the mount faces toward the ridge
of the roof. When deck attaching check for positive engagement into plywood
and avoid plywood seams. It should be tightened until the conical washer stops
rotating.
12
2 Modified Deck
! If the screw hits a nail under the shingle, there are a few solutions. Leave
the nail and use the rest of the holes if possible, if not: 1. Remove the nail
2. Angle the driver to avoid the nail 3. Use a 3mm steel drill to make a hole.
Part D: Ensuring Proper Installation
1
! Proper torque will vary based on the characterisitcs of the rafter and deck.
It’s best practice to tighten the wood screws until the washer stops rotating.
After completing process, make sure the Splice Foot X/XL is securely fixed.
You may verify that the screws underneath the deck panel are stained with
butyl rubber. This indicates a good flashing performance. Butyl should extrude
from the sides of the mount.
13
2
! If a screw head gets sheared, or a nail is hit, you must drill into the
remaining splice foot holes.
Part E: Leveling Uneven Roof Surfaces
1
! Using a standard comp shingle starter course, level out the roof surface
under the Splice Foot.
14
Part F: Attaching CrossRail
A Attaching Single CrossRail
! Position and install rail on back side of Splice Foot towards the ridge, as
shown in the image. Insert only one T-Bolt through one Splice Foot slot and
into side channel of CrossRail. Turn the T-Bolt clockwise ensuring that the
mark at the end of the shaft is vertical, indicating proper alignment. Tighten
to 25.8 ft-lbs (35 Nm).
B Splicing Two Rails
When connecting two rails to the Splice Foot, insert two T-Bolts through the
Splice Foot slots and into side ! channel of CrossRail. Turn the T-Bolts
clockwise ensuring that the mark at the end of the shaft is vertical,
indicating proper alignment. Leave a 1/8″ gap between rails in the center of
the Splice Foot. Tighten to 25.8 ft-lbs (35 Nm). Note: Rail connector function
for Splice Foot is only compatible with mill rail with kitted t-bolts. If
Splice foot is being used in conjunction with dark rail as a splice, bonded
t-bolts are required.
1/8″ gap
15
Bonding and Grounding
Appropriate means of bonding and grounding are required by regulation. The
information provided in this manual shall always be verified with local and
national building codes.
K2 Systems has obtained a UL 2703 system listing from Underwriter’s
Laboratories (UL).
A sample bonding path diagram is shown in Figure 1 below. Your specific
installation may vary, based upon site conditions and your AHJ`s requirements.
Each electrical connection has been evaluated to a maximum fuse rating of 30A.
At least one ground lug per row of modules must be used to ground all strings
within each sub-array, although additional may be used for redundancy. When
installed per these installation instructions, all connections meet the
requirements of NEC 690.43.
This racking system may be used to ground and/or mount a PV module complying
with UL 1703 only when the specific module has been evaluated for grounding
and/or mounting in compliance with the included instructions.
End Clamp (typical location)
K2 Ground Lug (typical location)
Splice Foot M10 Bonding T-Bolt (typical location)
Mid Clamp (typical location)
16
Fire Rating
The CrossRail System has undergone fire performance testing in accordance with
UL 2703, Fire Performance. A System Class A fire rating is achieved when using
CrossRail 44-X/48-X/48-XL under the following conditions: T Roof slope of
2/12″ rise per linear foot or greater T Used in combination with a UL 1703
Listed module with a fire performance rating of Type 1, Type 2, or Type
3. Consult the module manufacturer for specific fire performance rating
information. T CrossRail may be mounted using any stand-off height to maintain
the Class A fire rating. Always consult
the module manufacturers installation instructions to ensure your installation is in compliance with their UL 1703 Listing. T The results of the racking system do not improve a roof covering Class rating. All documentation can be found on UL
s Online Database as well as K2 Systems` website.
17
Compatible Modules
K2’s CrossRail System was tested with the following:
T UL/NRTL Listed Aptos Solar Modules: · DNA-120-MF26-XXXW · DNA-144-MF26-XXXW
· DNA-120-BF23-XXXW · DNA-120-MF23-XXXW · DNA-144-BF23-XXXW ·
DNA-144-MF23-XXXW
T UL/NRTL Listed Axitec Modules: · AC-xxP/156-60S · AC-xxxM/156-60S · AC-
xxxP/60V · AC-xxxP/60xV · AC-xxxP/60S · AC-xxxP/60x · AC-xxxMH/120S · AC-
xxxM/60V · AC-xxxM/60xV · AC-xxxMH/120V · AC-xxxM/60S · AC-xxxM/60x · AC-
xxxP/156-72S · AC-XXXP/72V · AC-XXXP/72XV · AC-XXXP/72S · AC-XXXP/72X · AC-
XXXMH/144S · AC-XXXM/72V · AC-XXXM/72XV · AC-XXXMH/144V · AC-XXXM/72S · AC-
XXXM/72X
T UL/NRTL Listed Boviet Modules: · BVM6612M 72-Cell Mono
T UL/NRTL Listed Canadian Solar Inc. Modules: · CS6U-xxx · CS6K-xxx · CS6X-xxx
· CS6P-xxx · CS3K-xxxP · CS3K-xxxMS · CS3U-xxxP · CS3U-xxxMS · CS3W-xxxP ·
CS3U-xxxPB-AG · CS3U-xxxMB-AG · CS3W-xxxPB-AG · CS1H-xxxMS
T CONTINUED – Canadian Solar Inc Modules: · CS6K-xxxM · CS6K-P-FG DYMOND ·
CS1Y-xxxMS · CS3N-xxxMS
T UL/NRTL Listed CertainTeed Modules: · CTXXXHC11-04 · CTXXXHC00-04 ·
CTxxxHC11-06
T UL/NRTL Listed ET Solar Modules: · ET-M660xxxBB
T UL/NRTL Listed Hansol Modules: · UB-AN1 Black 270-300 · UBAN1 Silver 270-300
· UD-AN1 330-360
T UL/NRTL Listed Hanwha Q Cells Modules: · Q.PEAK- G4.1/MAx xxx · Q.PEAK BLK
G4.1 xxx · Q.PRO G4 xxx · Q.PLUS G4 xxx · Q.PEAK-G4.1/TAA xxx · Q.PEAK BLK
G4.1/TAA xxx · Q.PLUS BFR G4.1/TAA xxx · Q.PLUS BFR G4.1/MAx xxx · B.LINE PLUS
BFR G4.1 xxx · B.LINE PRO BFR G4.1 xxx · Q.PEAK DUO-G5 xxx · Q.PEAK DUO BLK-G5
xxx · Q.PEAK DUO-G8 xxx · Q.PEAK DUO BLK-G8 xxx · Q.PEAK DUO-G7 xxx · Q.PEAK
DUO BLK-G7 xxx · Q.PEAK DUO G7.2 xxx · Q.PEAK DUO-G6 xxx · Q.PEAK DUO BLK-G6
xxx · Q.PEAK DUO BLK-G6+ xxx · Q.PEAK DUO-G6+ xxx · Q.PEAK DUO-G8+ xxx ·
Q.PEAK DUO BLK-G8+ xxx · Q.PEAK DUO L-G8.3 xxx · Q.PEAK DUO L-G8.2 xxx ·
Q.PEAK DUO L-G8.1 xxx · Q.PEAK DUO L-G8 xxx · Q.PEAK DUO L-G7.3 xxx · Q.PEAK
DUO L-G7.2 xxx · Q.PEAK DUO L-G7.1 xxx · Q.PEAK DUO L-G7 xxx
18
T CONTINUED – Hanwha Q Cells Modules: · Q.PEAK DUO L-G6 xxx · Q.PEAK DUO L-G6.2 xxx · Q.PEAK DUO L-G6.3 xxx · Q.PLUS DUO L-G5 xxx · Q.PLUS DUO L-G5.1 xxx · Q.PLUS DUO L-G5.2 xxx · Q.PLUS DUO L-G5.3 xxx · Q.PEAK DUO L-G5.2 xxx · Q.PEAK DUO L-G5.3 xxx · Q.PEAK L-G4.2 xxx · Q.PEAK L-G4.1 xxx · Q.PLUS L-G4.2 xxx · Q.PLUS L-G4.1 xxx · Q.PLUS L-G4 xxx · Q.PEAK DUO BLK G6+/SC xxx · Q.PEAK DUO G5/SC xxx · Q.PEAK DUO BLK G5/SC xxx · Q.Plus BFR-G4.1xxx · Q.Pro BFR-G4.1xxx · Q.Pro-G4.1/SCxxx · Q.PLUS BFR G4.1 xxx · Q.PRO BFR G4 xxx · Q.PRO BFR G4.1 xxx · Q.PRO BFR G4.3 xxx · Q.PEAK-G4.1 xxx · Q. PEAK DUO BLK G6+/TS XXX · Q.PEAK DUO G5/TS-XXX · Q.PEAK DUO BLK G6/TS XXX · Q.PEAK DUO G6 /TS-XXX · Q.PEAK DUO G6+/TS-XXX · Q.PEAK DUO ML-G9 XXX · Q.PEAK DUO ML-G9.2 XXX · Q.PEAK DUO ML BLK-G9 XXX · Q.PEAK DUO ML BLK-G9.2 XXX · Q.PEAK DUO XL-G9 XXX · Q.PEAK DUO XL-G9.2 XXX · Q.PEAK DUO XL BLK-G9 XXX · Q.PEAK DUO XL BLK-G9.2 XXX · Q.PEAK DUO XL BLK-G9.3 XXX · Q.PEAK DUO XL -G9.3 XXX · Q.PEAK DUO ML -G9.3 XXX · Q.PEAK DUO ML BLK -G9.3 XXX · Q.PEAK DUO ML -G9 XXX · Q.PEAK DUO ML -G9+ XXX · Q.PEAK DUO BLK ML -G9+ XXX · Q.PEAK DUO BLK ML -G9 XXX · Q.PEAK DUO BLK-G10+ · Q.PEAK DUO BLK ML-G10+ · Q.PEAK DUO BLK-G10+ / AC · Q.PEAK DUO BLK ML-G10.a · Q.PEAK DUO XL-G10.d
T CONTINUED – Hanwha Q Cells Modules: · Q.PEAK DUO BLK ML-G10 · Q.PEAK DUO BLK
ML-G10.a+ · Q.PEAK DUO BLK ML-G10.a+ /TS · Q.PEAK DUO XL-G10.2 · Q.PEAK DUO
XL-G10.c · Q.PEAK DUO XL-G10.3 · Q.PEAK DUO ML-G10 · Q.PEAK DUO ML-G10+
T UL/NRTL Listed Hyundai Modules: · HiS-MxxxMG · HiS-MxxxMI
T CONTINUED – Hyundai Modules: · HiS-MxxxTI · HiS-MxxxRI · HiS-SxxxRI · HiS-
MxxxRG
T UL/NRTL Listed Itek Modules · IT-xxx-SE · Hipro TP672M-xxx
T UL/NRTL Listed JA Solar Modules: · JAP6(DG) · JAM6(K)-60-xxx/4BB
T UL/NRTL Listed Jinko Solar Modules:: · JKMxxxPP-72-DV · JKMxxxPP-60-DV ·
JKMxxxM-60HBL · JKMxxxM-72HL-V · JKMxxxM-72HL-TV · JKMxxx-P-60 · JKMxxxM-
72HL4-TV · JKMxxxM-6RL3-B
T UL/NRTL Listed Kyocera Modules: · KUxxxMCA
T UL/NRTL Listed LG Electronics Inc. Modules: · LGxxxS1C-G4 · LGxxxN1C-G4 ·
LGxxxS2WG4 · LGxxxN1K-G4 · LGxxxN2W-G4 · LGxxxN1K-A5 · LGxxxQ1C-V5 ·
LGxxxQ1K-V5 · LGxxxN2W-A5 · LGxxxS2W-A5
T CONTINUED – LG Electronics Inc. Modules: · LGxxxN2T-A5 · LGxxxQ1C-A5 · LGxxxQ1K-A5 · LGxxxN2W-V5 · LGxxxN1C-V5 · LGxxxN1W-V5 · LGxxxN1K-V5 · LGXXXN2W-V5 · LGXXXN1C-V5 · LGXXXN1W-V5 · LGXXXN1K-V5 · LGXXXN2T-V5 · LGXXXN1C-N5 · LGXXXQ1C-N5 · LGXXXQ1K-N5 · LGXXXN1K-L5 · LGXXXN2W-L5 · LGXXXN2T-L5 · LGXXXN1W-L5 · LGXXXN1T-L5 · LGXXXA1C-V5 · LGXXXA1K-V5 · LGXXXM1C-N5 · LGXXXM1K-L5 · LGXXXQ1C-A6 · LGXXXQ1K-A6 · LGXXXQAC-A6 · LGXXXQAK-A6 · LGXXXN1C-A6 · LGXXXN1K-A6 · LGXXXN2W-E6 · LGXXXN2W-E6.AW5 · LGXXXN2T-E6 · LGXXXN1K-B6 · LGXXXQ1C-A6 · LGXXXQ1K-A6 · LGXXXQAC-A6 · LGXXXQAK-A6 · LGXXXN1C-A6 · LGXXXN1K-A6 · LGXXXN2W-E6 · LGXXXN2W-E6.AW5 · LGXXXN2T-E6 · LGXXXN1K-B6 · LGXXXA1C-A6 · LGXXXM1C-A6 · LGXXXM1K-A6 · LGxxxN16-E6
T UL/NRTL Listed Longi Modules: · LR6-72-xxxM (xxx=320-350) · LR6-72HV-xxxM
(xxx=320-350) · LR6-72BK-xxxM (xxx=320-350) · LR6-72PE-xxxM (xxx=340-380) ·
LR6-72PH-xxxM (xxx=340-380) · LR6-72PB-xxxM (xxx=340-380) · LR6-72HPB-xxxM
(xxx=360-385) · LR6-60-xxxM (xxx=270-300) · LR6-60HV-xxxM (xxx=270-300) · LR6
-60BK-xxxM (xxx=270-300) · LR6-60PE-xxxM (xxx=280-320) · LR6-60PH-xxxM
(xxx=280-320) · LR6-60PB-xxxM (xxx=280-320) · LR6-72BP-xxxM · LR6-60BP-xxxM ·
LR6-72HBD-xxxM · LR6-60-xxxM · LR6-60BK-xxxM · LR6-60PE-xxxM · LR6-60PB-xxxM ·
LR6-60PH-xxxM · LR6-60HPB/HIB-xxxM · LR6-60HPH/HIH-xxxM · LR6-72-xxxM · LR6
-72BK-xxxM · LR6-72HV-xxxM · LR6-72PE-xxxM · LR6-72PB-xxxM · LR6-72PH-xxxM ·
LR6-72HPH/HIH-xxxM · LR6-72BP-xxxM · LR6-72HBD/HIBD-xxxM · LR6-60BP-xxxM ·
LR6-60HBD/HIBD-xxxM · LR4-60HPH/HIH-xxxM · LR4-60HPB/HIB-xxxM · LR4-72HPH/HIH-
xxxM · LR4-72HBD/HIBD-xxxM · LR4-72HBD/HIBD-xxxM
T UL/NRTL Listed Lumos Modules: · LSxxxx-60M-B/C
T UL/NRTL Listed Luxor Solar Modules: · Lx-xxxP · Lx-xxxM
19
Compatible Modules continued
K2’s CrossRail System was tested with the following:
T UL/NRTL Listed Solaria Modules:
· PowerxT® -xxxR-PD
T UL/NRTL Listed Mission Solar Modules:
T UL/NRTL Listed REC Modules:
· PowerxT® -xxxR-BD
· MSExxxSB1J
· RECxxxTP2 BLK2
· MSExxxSO5T
· RECxxxTPS 72
· MSExxxSO4J
· RECxxxTP2S 72 XV
T UL/NRTL Listed Solarworld Modules
· MSExxxSQ6S
· RECxxxTP2SM 72 XV
“Sunmodule”:
· MSExxxSO6J
· RECxxxTP2SM 72
· Plus SW XXX Mono
· MSExxxSQ4S
· RECxxx NP
· MSExxxSQ5T
· RECxxx NP Black
T UL/NRTL Listed Soluxtec Modules:
· MSExxxSQ5K
· RECxxxAA
· FR xxx Wp
· MSExxxSQ8T
· RECxxxAA Black
· Power Slate 54 Mono Dark Series
· MSExxxSQ8K
· RECxxxTP4
· Power Slate 54 Mono Series
· MSExxxSQ9J
· RECxxxAAPure
· MSExxxSQ9S
· RECxxxTP4Black
T UL/NRTL Listed SunPower Modules:
· MSExxxSR8T
· SPR-E19-xxx
· MSExxxSR8K
· SPR-E20-xxx
· MSExxxSR9S
T UL/NRTL Listed Sanyo Electric Co Ltd of Pana-
· MSExxxSB1J
sonic Group Modules:
T UL/NRTL Listed Sunpreme Modules:
· MSExxxSX5T
· VBHNxxxSA16
· GxB-xxx
· MSExxxSX5K
· VBHNxxxSA17
· GxB-xxxSM
· MSExxxSX6S
· VBHNxxxSA18
· GxB-xxxSL
· MSExxxSX6W
· VBHNxxxSA16
T UL/NRTL Listed Sunspark Modules:
· MSExxxSX6Z
· VBHNxxxSA17
· SST-275-300M
· MSExxxSX5R
· VBHNxxxSA18
· SMX-250-265P
· VBHNxxxKA01
· SST-xxxM 60 cell
T UL/NRTL Listed Panasonic Modules:
· VBHNxxxKA03
· SST-xxxM 72 cell
· VBHNxxxSA16
· VBHNxxxKA04
· SST-xxxMB 60 cell
· VBHNxxxKA01
· SST-XXXM3B-60/72
· VBHNxxxKA03
T UL/NRTL Listed Seraphim Modules:
· SST-XXXM3-60/72
· VBHNxxxKA04
· SEG-XXX-6MA-HV
· SST-XXXM3B-60/72
· VBHNxxxSA17
· SEG-XXX-BMA-HV
· VBHNxxxSA18
T UL/NRTL Listed S-Energy Modules:
· VBHNxxxSA17E
T UL/NRTL Listed Silfab Modules:
· SN15-60PAE/PCE-xxxV
· EVPVxxx
· SLAxxxM
· SN10-60PAE/PBE/PCE-xxxV
· EVPVxxxK
· SLG-M-xxx
· SN15-60MAE/MCE-xxxV
· SLA-x-xxx
· SN10-60MAE/MCE-xxxV
T UL/NRTL Listed Peimar Modules:
· SLG-x-xxx
· SNxxxM-10T(SN60)
· SGxxxP-(BF)
· SIL-xxx BL
· SN15-72PAE/PCE-xxxV
· SGxxxP
· SIL-xxx HL
· SN10-72PAE/PBE/PCE-xxxV
· SGxxxM-(BF)
· SIL-xxx NL
· SN15-72MAE/MCE-xxxV
· SGxxxM
· SIL-xxx ML
· SN10-72MAE/MBE/MCE-xxxV
· SIL-xxx NT
· SN20-60MAE/MBE/MCE-xxxV
T UL/NRTL Listed Phono Solar Modules:
· SIL-xxx BK
· SN25-60MAE/MCE-xxxV
· PSxxxMG-20/U
· SIL-xxx NU
· SC20-60MAE/MBE/MCE-xxxV
· PSxxxPG-20/U
· SIL-xxx NX
· SC25-60MAE/MCE-xxxV
· PSxxxM-20/U
· SIL-xxxHC
· SN20-72MAE/MBE/MCE-xxxV
· PSxxxMH-20/U
· SN25-72MAE/MCE-xxxV
T UL/NRTL Listed Sharp Modules:
· SC20-72MAE/MBE/MCE-xxxV
T UL/NRTL Listed Prism Solar Modules:
· NU-SCxxx
· SC25-72MAE/MCE-xxxV
· Bi48 xxx Bifacial
· NU-SAxxx
· SD25-60BDE-xxxV
· Bi60 xxx Bifacial
· SD25-72BDE-xxxV
20
T UL/NRTL Listed Talesun Modules · Hipro TP660M-xxx · Hipro TP672M-xxx
T UL/NRTL Listed Trina Solar Modules: · TSM-xxxDE14A · TSM-xxxDD05A.08 ·
DUOMAX SPECS 1. PEG14 · DUOMAX SPECS 2. PEG5 · DUOMAX SPECS 3. PEG5.07 ·
DUOMAX SPECS 4. PDG5 · TSM-DE15H(II) · TSM-DE15M(II) · TSM-DD06M.05(II) · TSM-
DD06H.05(II) · TSM-DD06M.t5(II) · TSM-DD06H.T5(II) · TSM-PE15H · TSM-
DEG15HC.20(II) · TSM-DEG15MC.20(II) · TSM-DEG6HC.20(II) · TSM-DEG6MC.20(II) ·
TSM-xxxDE15V(ll) · TSM-xxxDE19 · TSM-xxxDEG15VC.20(ll) · TSM-xxxDEG19C.20
T UL/NRTL Listed V Energy Modules: · Series 200 PV
T UL/NRTL Listed Yingli Solar Modules: · YL-xxxP-29b · YL-xxx-35b
21
Notes
22
Notes
23
We support PV systems
Formerly Everest Solar Systems
Thank you for choosing a K2 mounting system.
Systems from K2 Systems are quick and easy to install. We hope these
instructions have helped. Please contact us with any questions or suggestions
for improvement. Our contact info: T k2-systems.com/en-US/contact T Telephone:
+1.760.301.5300