BEACON BIOSIGNALS BB420 SpotLite EEG Device Instruction Manual
- May 15, 2024
- BEACON BIOSIGNALS
Table of Contents
BEACON BIOSIGNALS BB420 SpotLite EEG Device
Current Issues To Resolve
Distribution: Per Jean, digital is satisfactory for 510K submission, but physical copies could be needed. That need is based on the preference of the hospitals. Should we plan to include a physical copy within the SpotLite System box?
References
- Peer IFUs and FDA Guidance
- Draft SpotLite User manual for compliance testing
- STAT Hardware Manual
- Byteflies Kit
Getting Started
What’s in the box Completed Your box includes:
- SpotLite EEG Device
- Charging Dock
- Power Adapter
- USB-C Cable
You should also have received
- A number of patch envelopes which contain
- The patch with SpotLite cradle attached
- 2 skin prep wipes
You should also have
- A mobile device with the SpotLite app installed and it is connected to the Wi-Fi
Descriptions
Ready for ReviewThe Beacon SpotLite System is a wearable self-contained EEG system designed to amplify and digitize and record the electroencephalogram (EEG) from a patient’s scalp. The recorded EEG signals are acquired by the SpotLite Device, transmitted to a mobile device in real time, and uploaded to the cloud storage after a recording session is completed. The recorded data is available for access for viewing on the Beacon Platform (not included in the SpotLite system). The Beacon platform provides the recorded signals for post- hoc review ONLY.
Indications for Use
Ready for ReviewThe SpotLite EEG System is intended to record, store, and
display EEG signals.
A reusable SpotLite Device is intended to amplify, capture and wirelessly
transmit the signals to the cloud storage via a mobile device. A single use,
disposable SpotLite Patch is an EEG electrode array to be used with the
SpotLite Device to record up to 8 channels of EEG signals.
The Beacon SpotLite EEG System does not provide any diagnostic conclusion
about the subject’s condition and does not provide any automated alerts of an
adverse clinical event. It is intended for prescription use in the home,
healthcare facility or clinical site where reduced montage EEG monitoring may
be desired.
Contraindications
Completed
- The SpotLite EEG System should not be used when real time EEG monitoring is required.
- The SpotLite EEG System does not provide real time alarms and should not be used to make life saving decisions.
- The SpotLite System should not be used on children under the age of 6
- The SpotLite Patch is manufactured with medical grade adhesives containing silicones, acrylics and conductive hydrogels. The Patch should not be used on patients with a suspected or known allergy to skin adhesives, acrylics, hydrogels, or silicones.
Warnings
Ready for Review
-
The SpotLite Device and SpotLite Patch have not been evaluated for safety in the MR environment. The
SpotLite Device and SpotLIte Patch have not been tested for heating or unwanted movement in the MR environment. The safety of the SpotLite Device within the MR environment is unknown. Performing an MR exam on a person who has this medical device may result in injury or device malfunction. -
Only place the Patch on intact skin, do not place the Patch on open wounds or abrasions.
-
Depending on wireless connectivity, a temporary interruption of data transmission is possible. Data will be stored on the device for transfer once connectivity is reestablished.
-
Do not use the SpotLite EEG Device or Patch in conjunction with defibrillation devices
Precautions In Progress
- Wireless electronic devices may cause signal interference during data transmission. Avoid close proximity with interfering devices.
- The Patch is single use only. Do not reapply or reuse the patch once it is removed.
- Do not use the SpotLite EEG Device or Patch if the package has been opened, or appears used, damaged, or expired.
- If prolonged discomfort or irritation occurs, the Patch should be removed. If mild soreness or redness is experienced after removing the Patch, take care to let the area heal prior to applying another Patch.
- Incorrect handling, excessive force, or dropping the SpotLite EEG Device may cause malfunction or permanent damage
- The SpotLite Device and Patch are not intended to be used in a wet environment; do not use the device while showering or under water.
- Keep the SpotLite EEG Device away from children and pets. The device may be a choking hazard, and may be harmful if swallowed.
- If the SpotLite EEG Device fails to operate, contact your healthcare provider immediately.
- This device has not been evaluated for use in a HF surgical environment.
System Overview
System Components Ready for Review
-
SpotLite EEG Device
The device is electrically connected to the Patch, samples the EEG signals, monitors the impedance of each
Patch electrode, and wirelessly transmits the data to a connected mobile device. -
Charging Dock
A wireless charging dock used to both charge and protect the SpotLite EEG Device when not in use. When the SpotLite EEG Device is placed within the charging dock, all EEG acquisition functions are automatically disabled. -
Patch
Multiple electrodes are attached to the forehead with adhesive on each electrode. Each Patch has a cradle to securely mount the EEG device. The conductive pads allow the EEG device to electrically connect to the Patch. -
Power Adaptor
100-240 V AC power adapter used to charge the SpotLite EEG Device. Only use the included power adapter to charge the SpotLite EEG Device. -
USB-C Cable
Cable used to connect the SpotLite EEG Device to the power adapter for charging. -
Mobile Device
A user interacts with the SpotLite system with a mobile device. The app installed on the device will guide the user on how to set up, start and stop the EEG recording. -
Cloud Storage
When the EEG recording is completed on the mobile device, the data is uploaded to the cloud storage for retrieval and analysis.
System Description
Ready for Review
The EEG device is connected to a wearable patch attached to the forehead that acquires brain wave signals continuously. The EEG device, the patch, the wireless charger, the companion mobile app and the cloud storage, collectively known as the SpotLite System, are custom designed by Beacon.
Phone Requirements Ready for Review
Supported phones and OS versions
OS | Phone model | OS version |
---|---|---|
iOS | Apple iPhone 14 | 16.2.X |
iOS | Apple iPhone 13 | 16.2.X |
iOS | Apple iPhone 12 | 16.2.X |
iOS | Apple iPhone 11 | 16.2.X |
iOS | Apple iPhone XR | 16.2.X |
Android | Google Pixel 6, 7 | 12, 13, 14 |
Android | Samsung Galaxy S2x | 12, 13, 14 |
Charging The Battery
Ready for Review
The SpotLite EEG Device is powered by a rechargeable battery.
To charge the battery, align the front of the SpotLite EEG Device (with logo)
with the front of the Charging Dock (the opposite side of the charging cable).
Gently push the device all the way into the charging dock.
During the charging, the light in the front of the charging dock is blinking.
When the charging is complete, the light turns solid. The charging time should
be less than 90 minutes.
If you notice longer charging time or significant reduction in the duration of
the SpotLite EEG Device operating time, the device may need to be replaced.
Powering On and Off the SpotLite EEG Device
To turn on the SpotLite EEG Device, press the green power button on the back
of the device. To turn off the SpotLite EEG Device, press and hold the green
power button for 5 seconds.
Quick Start Guide
For Self-Application
Author: Elliott Munoz Stephen Johnson Laura Edinger, in draft state In
Progress
Step 1
Confirm the LED on the SpotLite Device is green. This means the Device is on and paired with the SpotLite App.
Step 2
Remove a SpotLite EEG Patch from an envelope.
Step 3
Carefully place the SpotLite Device, bottom first, into the Cradle of the SpotLite Patch and listen for a click.
Step 4
Turn the Patch over and, using the plastic tab, remove the backing from the center of the Patch.
Step 5
Use a mirror to help place the patch about ½ an inch above the eyebrows with the Device centered between the eyes. Firmly press the Device against your forehead.
Step 6
Use the plastic tab to remove the backing from the left sensor and, taking care to avoid the hairline, place the sensor along the left side of the forehead.
Step 7
- Plug in and ensure you have access to your phone
- Be in the place where you plan to relax or sleep.
- If you need to get up at any time while recording, please take your phone with you and keep your patch on until you’re able to return to where you plan to relax or sleep.
Step 8: Monitoring
- When you are ready to begin, press “Start Monitoring”
- If there is an issue with a sensor during the monitoring, the screen will go red and direct you on how to address the issue
Step 9: Stop the EEG Monitoring
- Press the “Stop” button to end monitoring
For Assisted-Application
Author: Elliott Munoz Stephen Johnson Laura Edinger, in draft stateIn Progress
Step 1
Assist the user in turning on the device and confirm the LED on the SpotLite Device is green. This means the Device is on and paired with the SpotLite App.
Step 2
Assist the user in removing a SpotLite Patch from an envelope.
Step 3
Place SpotLite Device, bottom first, into the cradle until you hear a click.
Step 4
Turn the Patch over and use the plastic tab to remove the backing from the center of the Patch.
Step 5
Place the patch about ½ an inch above the eyebrows with the Device centered between the user’s eyes. Firmly press the Device against their forehead.
Step 6
Use the plastic tab to remove the backing from the left sensor and, taking care to avoid the hairline, place the sensor along the left side of the forehead.
Step 7
- Plug in and ensure the participant has access to their phone
- Be in the place where the participant plans to relax or sleep.
- If the participant needs to get up at any time while recording, instruct them to take their phone with them and keep the patch on until they’re able to return to where they plan to relax or sleep.
Step 8: Monitoring
- When they are ready to begin, press “Start Monitoring”
- If there is an issue with a sensor during the monitoring, the screen will go red and direct you on how to address the issue
Step 9: Stop the EEG Monitoring
- Press the “Stop” button to end monitoring
SpotLite App
Signing in
Author: Jean Wheeler Elliott Munoz, in draft state ❌ Blocked
After you receive your SpotLite EEG Device, you should receive a welcome email
to the email address you provided your administrator. If you have not received
the welcome email, please first check any junk or spam folders prior to
contacting your administrator.
The welcome email will include a link to finish setting up your [SpotLite]
account. Click the link and follow the instructions on how to update your
account password. This password, along with your email address will be the
credentials used for signing into the SpotLite app.
To access the SpotLite app, log in using the credentials provided to you by
your health care network administrator.
Home Screen
Author: Elliott Munoz In Progress
The home screen is divided into two sections. The top section contains an Overview carousel that orients the participant to the contents of the SpotLite System. The bottom section contains a button to start a recording.
Navigation
Author: Elliott Munoz In Progress
The Navigation consists of 3 menu items: Home, Record, and More. Each Menu item contains a representative icon and a label.
Home
Pressing “Home” will take you back to the Home Screen.
Record
Pressing “Record” will initiate a monitoring session.
Menu
Author: Elliott Munoz Not Started Ready for Review)
Pressing “Menu” will display five submenu items:
-
Account
Pressing “Account” will display “Sign Out” and five additional submenu items:
a. Notification Preferences
b. Consent Documents
c. Legal Notices
d. License Agreement
e. Privacy Policy -
The SpotLite System
-
Instructions
-
Contact
-
About
Starting an EEG Recording
Author: Elliott Munoz Ready for Review Once you click Start Monitoring from the “Monitoring Tips” screen, the Monitoring screen will appear as shown below. The Monitoring screen is composed of two sections. The top section displays LED Light settings, Battery life, and Signal Quality. The bottom section displays the elapsed time of the Monitoring session and the “Stop Monitoring” button.
If there are issues with a sensor during the monitoring session, a sheet will
appear with instructions for addressing the issue. A monitoring session will
not be stopped unless more than one sensor has an issue.
A user may end a monitoring session by clicking and confirming “Stop
Monitoring.” See the Stop Monitoring section of this manual on how to end a
recording.
Stopping an EEG Recording
Author: Elliott Munoz Ready for Review
It is possible to end a recording from the Monitoring screen by clicking on
“Stop Monitoring.”
An alert — as shown below — will appear asking you to either “Cancel” which
will send you back to the Monitoring screen or “Stop Monitoring” which will
end your monitoring session. Click “Stop Monitoring” to end your monitoring
session.
Ending your monitoring session will begin the file transfer process. See the
Uploading EEG Monitoring via Wi-Fi section of this manual for more
information.
Uploading EEG Monitoring via Wi-Fi
Author: David Klaffenbach Elliott Munoz Not Started
Maintenance
Cleaning SpotLite and the Charger
Author: David Klaffenbach Not Started
Disposing of patches
Author: Jean Wheeler Not Started
Disposing of SpotLite
Author: Jean Wheeler
Not Started
EEG Device Product Specifications Ready for Review
Parameter | Value/Description | Comments |
---|---|---|
Battery | Li-poly, 3.85V, 220mAh | |
Dimensions | 41 x 32 x 13 mm | H x W x D [1] |
Mass | approx. 14 g | |
Wireless Protocol | BLE 5.0 | |
Operating Temperature | 15 – 40 °C | |
Operating Humidity | 25 – 95 %RH w/o condensation | |
Shipping Temperature | -20 – 60 °C | |
Shipping Humidity | 15 – 95 %RH | |
Battery Life | > 12 hours, all features on | |
Number of Channels | 6 | |
Minimum Bandwidth | 0 – 70 Hz | [2] |
EEG Sample Rate | 250 sps | |
Input range | ±300.0 mV | |
Impedance measurement | Continuous | [3] |
Resolution | 35.8 nV | |
Common Mode Rejection Ratio (CMRR) | < 100μV pk-valley for 1Vrms | |
Crosstalk rejection | 40 dB | |
Noise | < 1.0 μVrms | |
Charging interface | Qi (inductive) 5 W | |
Charger | Proprietary | |
Charger dimensions | 51 x 43 x 47 mm | H x W x D |
--- | --- | --- |
Charger mass | approx. 70 g | |
EEG connection to Patch | Proprietary |
- Not including protrusions of pogo pins or the latch feature.
- The SpotLite does not high-pass filter the data.
- Continuous, out of band (125Hz), AC impedance measurements.
This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions:
- This device may not cause harmful interference, and
- This device must accept any interference received, including interference that may cause undesired operation.
Caution : Changes or modifications not expressly approved by the party responsible for compliance could void the user’s authority to operate the equipment.
NOTE : This equipment has been tested and found to comply with the limits
for a Class B digital device, pursuant to part 15 of the FCC Rules. These
limits are designed to provide reasonable protection against harmful
interference in a residential installation. This equipment generates, uses and
can radiate radio frequency energy and, if not installed and used in
accordance with the instructions, may cause harmful interference to radio
communications.
However, there is no guarantee that interference will not occur in a
particular installation. If this equipment does cause harmful interference to
radio or television reception, which can be determined by turning the
equipment off and on, the user is encouraged to try to correct the
interference by one or more of the following measures:
- Reorient or relocate the receiving antenna.
- Increase the separation between the equipment and receiver.
- Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.
- Consult the dealer or an experienced radio/TV technician for help.
-
WARNING: Use of this equipment adjacent to or stacked with other equipment should be avoided because it could result in improper operation. If such use is necessary, this equipment and the other equipment should be observed to verify that they are operating normally.”
-
WARNING: Use of accessories, transducers and cables other than those specified or provided by the manufacturer of this equipment could result in increased electromagnetic emissions or decreased electromagnetic immunity of this equipment and result in improper operation.”
-
WARNING: Portable RF communications equipment (including peripherals such as antenna cables and external antennas) should be used no closer than 30 cm (12 inches) to any part of the ME equipment, including cables specified by the manufacturer. Otherwise, degradation of the performance of this equipment could result.”
Table 1 -
RF Exposure Compliance(Spotlite)
This equipment complies with FCC radiation exposure limits set forth for an uncontrolled environment.
This transmitter must not be co-located or operating in conjunction with any other antenna or transmitter.
This equipment should be installed and operated with minimum distance 00cm between the radiator and your body.
*4 RF Exposure Compliance(Wireless charger)**
This equipment complies with FCC radiation exposure limits set forth for an
uncontrolled environment.
This equipment should be installed and operated with minimum distance 20cm
between the radiator and your body. This transmitter must not be co-located or
operating in conjunction with any other antenna or transmitter.
FCC Declaration – Electromagnetic Emission
Emissions test| Compliance
RF emissions CISPR 11| Group 1
RF emissions CISPR 11| Class B
Harmonic emissions IEC 61000-3-2| Class A
Voltage fluctuations/ flicker emissions IEC 61000-3-3| Clause 5
Table 2
Declaration – Electromagnetic Immunity
Immunity test| IEC 60601 test level| Compliance level
Electrostatic discharge (ESD) IEC 61000-4-2| ±8 kV contact ±2 kV, ±4 kV, ±8
kV, ±15 kV air| ±8 kV contact ±2 kV, ±4 kV, ±8 kV, ±15 kV air
Electrical fast| ± 2 kV for power supply| ± 2 kV for power supply lines
transient/burst| lines| ± 1 kV for input/output lines
IEC 61000-4-4| ± 1 kV for input/output|
| lines|
Surge IEC 61000-4-5| ± 0.5kV, ± 1 kV line(s) to lines ± 0.5kV, ± 1 kV, ± 2 kV
line(s) to earth| ± 0.5kV, ± 1 kV line(s) to lines
± 0.5kV, ± 1 kV, ± 2 kV line(s) to earth
Voltage dips, short interruptions and voltage variations on power supply input
lines
IEC 61000-4-11
| 0 % UT; 0.5 cycle At 0°, 45°, 90°, 135°, 180°, 225°, 270°and 315°
0 % UT; 1 cycle and
70 % UT; 25/30 cycles Single phase: at 0°| 0 % UT; 0.5 cycle At 0°, 45°,
90°, 135°, 180°, 225°, 270°and 315° 0 % UT; 1 cycle and 70 % UT; 25/30 cycles
Single phase: at 0°
| | 0 % UT; 250/300 cycles
| 0 % UT; 250/300 cycles|
Power frequency (50/60 Hz)
magnetic field IEC 61000-4-8| 30 A/m| 30 A/m
NOTE : UT is the a.c. mains voltage prior to application of the test
level.
Table 3
Declaration – Electromagnetic Immunity
Immunity test| IEC 60601 test level| Compliance level
Conducted RF IEC 61000-4-6| 3 V
0.15 MHz to 80 MHz| 3 V
0.15 MHz to 80 MHz
6 V in ISM bands between 0.15 MHz and 80 MHz
| 6 V in ISM bands between 0.15 MHz and 80 MHz| 3Vrms (emf),
6Vrms (emf) in ISM bands between 0.15 MHz and 80 MHz 80%, 1 kHz
---|---|---
Radiated RF IEC 61000-4-3| 10V/m
80 MHz to 2.7 GHz| 10V/m
Immunity to proximity magnetic fields in the frequency range
IEC 61000-4-39| Immunity to proximity magnetic fields in the frequency range 9
kHz to 13.56| See table 11 of standard
Any one of its nominal input voltages and frequencies
Table 4
Declaration – IMMUNITY to proximity fields from RF wireless communications equipment
Immunity test| IEC60601 test level| Compliance level
Test frequency| Modulation| Maximum power| Immunity level
Radiated RF
IEC 61000- 4-3| 385 MHz| *Pulse Modulation: 18Hz| 1.8W| 27 V/m| 27 V/m
450 MHz| FM+ 5Hz deviation: 1kHz sine| 2 W| 28 V/m| 28 V/m
710 MHz
745 MHz
780 MHz| Pulse Modulation: 217Hz| 0.2 W| 9 V/m| 9 V/m
810 MHz
870 MHz
930 MHz| Pulse Modulation: 18Hz| 2 W| 28 V/m| 28 V/m
1720 MHz
1845 MHz
1970 MHz| Pulse Modulation: 217Hz| 2 W| 28 V/m| 28 V/m
2450 MHz| Pulse Modulation: 217Hz| 2 W| 28 V/m| 28 V/m
5240 MHz
5500 MHz
5785 MHz| **Pulse Modulation: 217Hz| 0.2 W| 9 V/m| 9 V/m
**Note* – As an alternative to FM modulation, 50 % pulse modulation at 18
Hz may be used because while it does not represent actual modulation, it would
be worst case.
Note**** – The carrier shall be modulated using a 50 % duty cycle square
wave signal.
Verdict summary section
IEC 60601-1-2 referenced emission standards
Clause| Requirement – Test case| Basic standard| Verdict
7.1| Terminal disturbance voltages| CISPR 11:2015 +A1:2016 + A2:2019| P
7.1| Radiation disturbance| CISPR 11:2015 +A1:2016 + A2:2019| P
7.2.1| AC-Mains Harmonics| IEC 61000-3-2:2005 +A1:2008
+A2:2009
| P
7.2.2| AC-Mains Voltage fluctuations and flicker| IEC 61000-3-3:2013| P
IEC 60601-1-2 referenced immunity standards
Clause| Requirement – Test case| Basic standard| Verdict
8.9| ELECTROSTATIC DISCHARGE| IEC 61000-4-2:2008| P
8.9| Radiated RF EM fields| IEC 61000-4-3:2006 +A1:2007
+A2:2010
| P
8.9| Electrical fast transients / bursts| IEC 61000-4-4:2012| P
8.9| Surges| IEC 61000-4-5:2014+A1:2017| P
8.9| Conducted disturbances induced by RF fields| IEC 61000-4-6:2013| P
8.9| RATED power frequency magnetic fields| IEC 61000-4-8:2009| P
8.9| Voltage dips| IEC 61000-4-11:2004 + A1:2017| P
8.9| Voltage interruptions| IEC 61000-4-11:2004 + A1:2017| P
8.10| IMMUNITY to proximity fields from RF wireless communications equipment|
IEC 60601-1-2:2014 + A1:2020
Table 9
| P
8.11| Immunity to proximity magnetic fields| IEC 61000-4-39:2017| P
Supplementary information: None.
Troubleshooting
Author: Yongbo Wang Not Started
Contact Information
Author : Jean Wheeler In Progress
For [questions/issues] related to SpotLite, please email
spotlite@beacon.bio
For more information on Beacon Biosignals and SpotLite, visit
www.beacon.bio
Glossary
Meaning of Symbols
-
Single Use Only
-
Not made with latex
-
Non-Sterile
-
Consult Instructions for use
-
Upper limit of temperature
-
Batch Code
-
Manufacture Date
-
Expiration Date
-
Manufactured by
-
Quantity
-
Prescription Only
References
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>