Meditub 2953WCA Wheelchair Accessible Bathtub Instruction Manual

May 15, 2024
MediTub

Meditub 2953WCA Wheelchair Accessible Bathtub

Meditub-2953WCA-Wheelchair-Accessible-Bathtub-PRODUCT

Product Specifications

  • Model: 2953 WHEELCHAIR ACCESS

  • Dimensions: 29 x 53 inches

  • Available Therapy Systems:

    • 2953WCA**S – Non-Jetted Soaking
    • 2953WCA**H – Whirlpool Jetted
    • 2953WCA**A – Air Jetted
    • 2953WCA**D – Whirlpool & Air Jetted
  • Key Attributes:

    • Walk-in Type: Wheelchair Accessible
    • Material: Acrylic Soaker
    • Weight: 140 lbs (Soaker), 175 lbs (Jetted)
    • Average Fill Capacity: 80-90 gal (Estimated with occupant
      inside)
  • Required Electrical Service:

    • Air Bath or Whirlpool: 1x 15 amp GFCI
    • Whirlpool w/ Inline Heater: 1x 20 amp GFCI
    • Whirlpool & Air Jetted: 1x 20 amp GFCI
    • Soaker: n/a
  • Standards: ASME A112.19.15; CSA C22.2 No. 218.2-15; UL 1795, 5th Edition

  • Certified: UPC, EGS

Product Usage Instructions

  1. Leveling: Ensure the tub is completely level with all leveling feet touching the floor for the door, seal, and drain to work properly.
  2. Electrical Requirements: Follow the specified electrical service requirements based on the therapy system installed.
  3. Maintenance: Refer to the user manual for maintenance instructions to ensure optimal performance and longevity of the product.
  4. Registration: Register the product within 5 business days of delivery date at SWCORP.com/register for more information.

Frequently Asked Questions (FAQ)

Q: What is the average fill capacity of the tub?
A: The average fill capacity is estimated to be between 80-90 gallons, varying based on the occupant’s volume.

Q: What are the electrical requirements for the different therapy systems?
A: The electrical requirements vary based on the therapy system:

  • Air Bath or Whirlpool: 1x 15 amp GFCI
  • Whirlpool w/ Inline Heater: 1x 20 amp GFCI
  • Whirlpool & Air Jetted: 1x 20 amp GFCI
  • Soaker: Not applicable (n/a)

Q: How should I maintain the product for optimal performance?
A: Regular maintenance as outlined in the user manual is essential to ensure optimal performance and longevity of the product. This may include cleaning, inspection, and preventive measures.

2953 WHEELCHAIR ACCESS 29” x 53”

Key Attributes

  • Walk-in Type: …………………………………Wheelchair Accessible
  • Material: ………………………………………… Acrylic
  • Soaker Weight: ……………………………… 140 lbs
  • Jetted Weight: ………………………………. 175 lbs
  • Average Fill Capacity*: ………………… 80-90 gal
  • *Estimated with occupant inside. May vary based on occupant’s volume.

Required Electrical Service 110v

  • Air Bath or Whirlpool ……………………. 1x 15 amp GFCI
  • Whirlpool w/ Inline Heater ………….. 1x 20 amp GFCI
  • Whirlpool & Air Jetted ………………….. 1x 20 amp GFCI
  • Soaker …………………………………………….. n/a

Available Therapy Systems

  • 2953WCA**S …………………Non-Jetted Soaking
  • 2953WCA**H …………………Whirlpool Jetted
  • 2953WCA**A ………………..Air Jetted
  • 2953WCA**D…………………Whirlpool & Air Jetted

Key Measurements (inches)

  • Overall Outer: ……………….52.5 x 29.5 x 42
  • Interior Width: ………………23.5
  • Standing Area: ……………..20 x 20
  • Seat Width: ……………………20
  • Seat Height: ………………….18
  • Soaking Depth: …………….31.5
  • Drain to Side Wall: ……….11
  • Drain to Back Wall: ……….15
  • Step-in Height: …………….6
  • Door Clearance: ……………n/a
  • Faucet Deck: ………………….5
  • Tile Flange: …………………….1.2
  • Extension Kit: ………………..7

It is vital that tub is completely level with all leveling feet touching the floor for the door, seal and drain to work properly.

Meditub-2953WCA-Wheelchair-Accessible-Bathtub-

Compliance: Uniform Plumbing Code UPC®;; International Plumbing Code IPC®; ADA
Standards: ASME A112.19.15; CSA C22.2 No. 218.2-15; UL 1795, 5th Edition Issued September 02, 2016 including revisions through August 25, 2017
Certifeid: UPC,EGS

  • IMPORTANT! TEST THE TUB’S DRAIN AND JETS (if any) BEFORE PERMANENT INSTALLATION!
  • INSPECT THE TUB WHEN RECEIVED! Report any damages or missing parts within 5 business days of delivery date.
  • Before ordering or installing, please consider future access to equipment.
  • Please measure tub on-site before building tub surrounding!
  • Jet, pump & blower locations are predetermined and cannot be changed.
  • Tub door must remain closed when not in use.
  • Please note that installers) must be certified or warranty will be voided.
  • Measurements are subject to a +/- .5” variance and subject to change without notice. Measurements here in supersede all other published specs prior to publication date shown below.
  • Inline heater (if included) is designed to maintain water temperature during operation. It will not heat cold water to desired bathing temperature.
  • Product must be registered for warranty activation. See user manual or visit SWCORP.com/register for more information.

v5 / 201905. All rights reserved. Subject to change without notice.

References

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>