Whyte ADA102 A Series Advanced Distribution Amplifier Instruction Manual

June 4, 2024
WHYTE

Whyte ADA102 A Series Advanced Distribution Amplifier

Whyte ADA102 A Series Advanced Distribution Amplifier-
PRO

SAFETY

  • The Whyte Series A Distribution Amplifiers are intended for indoor use only.
  • Do not install the Distribution Amplifier in damp, humid, hot, or dusty areas.
  • Switch off the source of power when making connections to the Distribution
  • Amplifier to avoid damaging the unit.
  • Always earth bond the Distribution Amplifier using the Earth Bonding Lug to a suitable Earth Bonding point using up to 6mm2 core earth cable.

PRECAUTIONS

To ensure a trouble-free operation of your Whyte Distribution Amplifier: Do not remove the cover of the Distribution Amplifier or dissemble it, as this will invalidate your guarantee. The female F-Type connectors on this unit were designed for use with ‘100’ type coaxial cable with a center core diameter of 1mm2. When using larger diameter ‘125’ or ‘165’ coaxial cables, you must ensure that suitable IF connectors with reducing pins are used, otherwise damage to the unit will occur which will invalidate the guarantee. Do not over-tighten the F connectors (finger tight only).

GUARANTEE

All Whyte products are guaranteed for a period of 4 years from the date of purchase against defects. Within this period, Whyte Technologies will repair or replace the faulty product. In the unlikely event, please return any faulty products to your dealer. The guarantee will be deemed void if the serial number on the product is removed, damaged or illegible. The guarantee excludes defects caused by incorrect use, accidental damage, disassembly, water/fire/lightening damage or lack of ventilation

GENERAL DESCRIPTION

A comprehensive range of RED-compliant, professional Advanced Distribution Amplifiers with IRS Loop-through. This enables Whyte Series A Distribution Amplifiers to be connected directly to a Multiswitch subscriber output whereby the SAT and TERR/RADIO signals are passed through the Distribution Amplifier before terminating at the outlet plate. The TERR/RADIO signals are amplified before being distributed to the TERR & RADIO outlets.
The Whyte Series A Distribution Amplifiers are available in sizes ranging from 2-Way to 16-Way. The IRS Loop-through can also be used to cascade multiple units to create large-scale Master Antenna TV systems (MATV). When used as a standard TERR and RADIO Distribution Amplifier, the Whyte range of Distribution Amplifiers offer a professional, low noise, high gain solution.

Features include:

  • RED Compliant
  • Ultra-Low Noise ≤4dB
  • 10dB ~ 12dB Gain (depending on model)
  • Gain Control
  • IRS Loop-Through
  • Cascadable
  • LTE Filter (4G)
  • High-Quality Distribution Amplifier with a 4-year guarantee
  • Internal power supply
  • Remote Powering via all outputs
  • Adequate cable clearance for routing underneath
  • Models available include 2, 4, 6, 8, 12 and 16-way output

PRODUCT DESCRIPTION

Whyte ADA102 A Series Advanced Distribution
Amplifier-1

  1. AC In Power Cord
  2. Transformer Housing
  3. Subscriber Outputs
  4. TERR / IRS Input
  5. Gain Control
  6. IRS Loop Output
  7. Earth Lug
  8. LED Power Indicator
  9. Corner Brackets
  10. UK Mains Plug

TECHNICAL DESCRIPTION

  • The Whyte Series A Advanced Distribution Amplifier has been designed to meet the requirements of the modern Integrated TV & Satellite Integrated Reception System.

  • The range features an IRS Loop-through which enables Whyte Series A Distribution Amplifiers to connected directly to a Multiswitch subscriber output.

  • The IRS Loop through is passive and passes all frequencies between 87MHz to 2340MHz. The IRS Loop-through permits 22kHz tone as well as DiSEqC commands to be passed backwards. Hence the ADA 100 series Advanced Distribution Amplifiers are compatible with both legacy and dSCR Multiswitches.
    Used as a Terrestrial TV and Radio Distribution Amplifier (MATV), the ADA provides unrivalled low noise, high gain performance and reliability. This RED compliant

  • Distribution Amplifier includes a high rejection 4G Filter and features a 15dB Gain Control which ensures that the ADA100 can be applied to most any signal level scenario.

  • The unit can be powered via the AC mains lead supplied or, in the absence of mains supply can be remotely powered via any of the TERR Outputs using a suitable PSU (not included).

INSTALLATION INSTRUCTIONS

MOUNTING THE DISTRIUTION AMPLIFIER
Select a suitable location to install the Distribution Amplifier. Do not install the Distribution Amplifier in damp, humid, hot, or dusty areas. Using the screw slots on the corner brackets and transformer housing secure the Distribution Amplifier using the supplied fixing screws or other fixing to suit the relevant wall, surface, or cabinet.

EARTH BONDING
Earth bond the Distribution Amplifier to the Earth Bonding Lug using minimum 6mm2 Earth Bonding Cable. Make sure that the Earth Bonding Cable is connected directly to the buildings PME (Protective Multiple Earthing) point.

USING THE INTERNAL AC POWER SUPPLY
Where a 230V UK AC socket outlet is available the Distribution Amplifier can be plugged in to provide power to the amplifier circuit. AC cord with 3A fused BS1363 moulded UK mains plug included.

DC POWER OPTIONS

Whyte ADA102 A Series Advanced Distribution
Amplifier-2

EXAMPLE CONFIGURATION

Single SAT + MATV (AC Power)

Whyte ADA102 A Series Advanced Distribution
Amplifier-3

Apt TERR Distribution via IRS (AC Power)

Whyte ADA102 A Series Advanced Distribution
Amplifier-4

Cascading MATV System

Whyte ADA102 A Series Advanced Distribution
Amplifier-5

MATV (AC Power)

Whyte ADA102 A Series Advanced Distribution
Amplifier-6

MATV (DC Remote Power)

Whyte ADA102 A Series Advanced Distribution
Amplifier-7

SPECIFICATIONS

ADA102 | ADA104

MODEL ADA102                                 ADA104

 |  |
TERR Frequency Range| 87MHz ~ 782MHz| 87MHz ~ 782MHz
TERR/IRS Input (F-Type Female)| 1| 1
TERR Tap Outputs (F-Type Female)| 2| 4
SAT Loop Through (F-Type Female)| 1 x 87~ 2350MHz| 1 x 87~ 2350MHz
RED Compliance| Class 3| Class 3
TERR Gain| 12dB| 10dB
Max Output TERR (IMA3 -60dB)| 90dBuV| 90dBuV
Max Noise Figure| ≤4dB| ≤4dB
SAT Through Loss| 4dB| 4dB
Impedance| 75 Ω| 75 Ω
Loop Through Passing| 13/18V / 22kHz / DiSEqC| 13/18V / 22kHz / DiSEqC
Mains Operation| 230V AC| 230V AC
Remote DC Powering (via TERR outputs)| 12V DC| 12V DC
Remote DC Consumption| 40mA Max| 40mA Max
Power Indicator| LED| LED
Earth Lug| Up to 6mm2 core| Up to 6mm2 core
Dimensions W x L x H (mm)| 168x116x43| 168x116x43
Weight| 332g| 340g

ADA106 | ADA108 | ADA112 | ADA116

ADA106 ADA108                            ADA112 ADA116

 |  |  |
87MHz ~ 782MHz| 87MHz ~ 782MHz| 87MHz ~ 782MHz| 87MHz ~ 782MHz
1| 1| 1| 1
6| 8| 12| 16
1 x 87~ 2350MHz| 1 x 87~ 2350MHz| 1 x 87~ 2350MHz| 1 x 87~ 2350MHz
Class 3| Class 3| Class 3| Class 3
10dB| 12dB| 10dB| 10dB
90dBuV| 90dBuV| 90dBuV| 90dBuV
≤4dB| ≤4dB| ≤4dB| ≤4dB
4dB| 4dB| 4dB| 4dB
75 Ω| 75 Ω| 75 Ω| 75 Ω
13/18V/22kHz/DiSEqC| 13/18V/22kHz/DiSEqC| 13/18V/22kHz/DiSEqC| 13/18V/22kHz/DiSEqC
230V AC| 230V AC| 230V AC| 230V AC
12V DC| 12V DC| 12V DC| 12V DC
100mA Max| 100mA Max| 100mA Max| 100mA Max
LED| LED| LED| LED
Up to 6mm2 core| Up to 6mm2 core| Up to 6mm2 core| Up to 6mm2 core
200x116x43| 200x116x43| 200x116x43| 232x116x43
450g| 458g| 472g| 528g