MACY-PAN ST1700 Soft Sitting Type Hyperbaric Chamber User Manual

August 24, 2024
MACY PAN

MACY-PAN ST1700 Soft Sitting Type Hyperbaric Chamber

FAQs

Q: How do I update the maps on my GPS device?

A: To update maps, connect your device to a computer and use the provided software to download and install the latest map updates.

Q: Can I use the GPS device while driving?

A: Yes, you can safely use the GPS device while driving by mounting it securely on the dashboard or windshield using a compatible mount.

Foreword

People cannot live without air, especially oxygen. The oxygen percentage in the normal air pressure is 21%. People will suffer a hyperoxic death if oxygen is lower than 12%. 90% of the people in the city are in various degrees of hypoxia. Hyperbaric oxygen therapy improves the quality of life and keeps us more healthy. It is the latest trend in health and beauty.

Symbols

The following table is a list of symbols and definitions that are used with the Hyperbaric Chamber.

Safety Notice

In order to ensure safety, please read the following precautions before use

Warning:

  • Abnormal smell during use, please turn off the power and pull out the plug; Please make sure the socket plug is fully inserted;
  • Please do not disassemble the machine without permission from the supplier; This product needs to stay away from water fire and sharp objects; Children need to use it under adult care;
  • Please do not touch any valves on the chamber while using it;
  • Please do not place heavy objects on the machine;
  • Do not use it if the wire is loose;
  • Do not pull or twist the power cord;
  • Hand wet Do not touch the power plug and switch;
  • Do not use it in a bathroom or other damp environment;

Prohibit the use of crowd:

  • Pregnant women people with severe infectious diseases and patients
  • Bad colds, Pneumothorax patients
  • Patients with severe emphysema
  • Hypertension exceeds 160 / 100ml
  • Severe heart problems

Notice

  •  In the chamber, when the pressure is rising, the ears may have a sense of squeezing, just like the feeling of taking a plane up and down. This is normal. The following methods can be used to debug: a. Spit saliva; b. Chewing candy, c. Yawning;
    • Pinch nose and blowstay in the chamber, when the pressure is stable at 30kPa. This discomfort will gradually disappear.
  • Zippers can be opened only when the chamber has depressurized to 0kPa.
  • After get out of the chamber, please turn off the power immediately after use, cleaning work in a timely manner.

Product specifications and construction

  • chamber
1   cover 8 External pressure gauge
2   Oxygen inlet valve 9 internal pressure gauge
3   Air inlet valve 10 Emergency pressure relief valve
4   viewing window 11 Automatic pressure relief valves
5   Anti-roll bolster 12 Spare ports
6   zipper  
7   Air deflate valves  
  • Air compressor
Voltage 110/220/240V
Air Flow 72L/Minute
Power 480W
Weight 18KG
  • Oxygen concentrator
Voltage 110/220/240V
Oxygen Flow 1-5L/Minute
Power 480W
Weight 30KG
  • Air cooler
Voltage 110/220/240V
Capability 150L/Minute
Pressure 0.8mPa
Power 220w
Weight 5kg

Product assembly and operation

Working Scheme

Installation

  1. Please open the four boxes before installation ①Box: Chamber + accessories
  2. Connect the power cables of the air compressor, oxygen concentrator, and air cooler.
  3. Connect the oxygen tube on the oxygen concentrator to the oxygen inlet valve of the chamber; connect the air tube on the air compressor to the air cooler(Air In); connect another air tube on the air cooler, from(Air Out)to the chamber.
  4. Install the internal/external pressure gauge, automatic pressure relief valves, emergency pressure relief valves, non-porous plugs, silencers.
  5. Install the metal frame, which needs to be installed inside the chamber. It is recommended to take all frames into the chamber, and then install the frames after the chamber is inflated.
  6. Place the anti-roll bolsters.

Operation

  1. Switch on the machines,Adjusting oxygen levels
  2. Get into the chamber, pull the inside and outside zippers, and close the air deflate valve (make sure to flatten out the silicone strip between the zippers)
    • Zippers and Air Deflate Valve can be operated both inside and outside the chamber.
  3. Lie down and wear an oxygen headset or mask.
  4. In about 8 minutes, the chamber pressure gauge will slowly rise up to 30kPa, at this time the automatic pressure release valve will exhaust air automatically.
  5. It is recommended to use 60-80 mins per session.
  6. After use, please open the Air Deflate Valve to reduce pressure first.
  7. When the pressure gauge shows 0kPa, open the zippers and get out of the chamber
  8. After getting out of the chamber, turn off the air compressor, oxygen concentrator, and air cooler.

Precautions when using

  • When using for the first time, please test the empty chamber first and observe whether the equipment is operating normally. If the equipment is running abnormally, please do not use it. Please contact your dealer promptly.
  • When you need to get out of the chamber, wait until the pressure gauge shows 0kPa before you open the inner and outer zippers. Do not force the zipper to open during use or when pressure relief is not complete.
  • In the event of an emergency or if the air deflate valve fails to operate properly, push the emergency relief valve from inside the chamber to relieve pressure. When the pressure is 0, pull the zipper and get out of the chamber
  • When you use the device for the first time, there is slight discomfort or pain in your ears. This is a normal phenomenon caused by pressure increase. You can improve your discomfort by chewing or swallowing. After several uses, this phenomenon will gradually disappear.

Preparing before hyperbaric therapy

  1. Clothing
    • People may go to the chamber fully clothed, and wear loose, comfortable clothes. People may bring electronic products/drinks into the chamber. Ladies should remove long socks(silk stocking) into the chamber. Please take off shoes before getting in. Shoes, jewelry, or any sharp objects that could damage the chamber should be removed. Disposable feet and hair covers may be used for increased sanitation. To make the therapy experience more pleasant, the person should get as comfortable as possible, which means taking care of restroom breaks and/or drinking water before getting into the chamber. The user should be advised to relax and breathe normally. Breathe normally during the therapy. The air inside the chamber will be continually exchanged, people should have no difficulty breathing.
  2. Chamber Pressurization
    • During pressurization, if people feel pain in the ears due to the tympanic membrane receiving extrusion pressure,the ear can cause tingling. It’s normal, at this point, people can do some chewing gum motion or swallow-ing to adapt to the pressure change. The user will feel normal when the pressure is stable at 30kPa. But if the user can’t bear the pain anymore, for instance, when the pressure rise to 15kPa, the ears feel very painful, the user should either turn off the compressor immediately, or unscrew the air deflate valve slowly, to reduce the speed of pressurizing. when people feel better after a while, screw the air deflate again, until it gets 30kPa. When a session is finished, turn off the machine and unscrew the air deflate valve to depressurize the chamber, the pressure will drop slowly from 30kPa to 0kPa, this depressurization process should be more than 5 mins, if too fast, people might feel pain in the ear and there is risk of decompression sickness. When the pressure gauges appear 0kPa, zippers can be opened, people can get out

Maintenance

Chamber maintenance and cleaning
Clean the chamber: After using a deodorizing and antibacterial spray, or after diluting it twice with alcohol, wipe it and let it dry. Drive the machine to run for 20 minutes.

Air compressor maintenance and cleaning
It is recommended to replace the activated carbon filter cotton every 6 months.

Oxygen Concentrator maintenance and cleaning

  • the oxygen machine also has 2 filter cotton to achieve a better filtration effect:
  • The first place is the black filter cotton on the back mesh cover, as in Figure 1. Its role is to filter the air entering the compressor. Just open the cover and clean the filter to achieve the purpose of maintenance.
  • The second is the two white filter pads, as shown in Figure 2, which can be replaced to maintain the oxygen concentrator.

FAQS

  1. What should I do to prepare for a treatment?
    • People can go into the chamber fully clothed. It is recommended to wear loose comfortable. Shoes, jewelry, or any sharp objects should be removed before getting into the chamber. It is recommended that women not wear stockings in the chamber, because it may cause feelings of claustrophobia.
  2. How will the HBOT treatment feel?
    • The chamber will be filled with compressed air. Once the chamber has expanded to its filled size, it will start to pressurize. While the chamber is pressurizing, your ears will feel the change in pressure inside the chamber. Otherwise, it should be unnoticeable. To equalize the pressure and avoid the feeling of fullness in your ears, you will need to clear your ears by chewing (gum or food), swallowing, and yawning. During the pressurization of the chamber, your mouth may become dry. Once the chamber is fully pressurized, your salivation will return to normal. Additionally, the chamber may become slightly warm while it is pressurizing. Once it is to full pressure, the relief valves will begin to pull the warmer air out of the chamber. Then you can sleep, meditate, read, watch movies, listen to music, etc.
  3. How long is the treatment?
    • Treatment times are usually 1-2 hours per session, 5-7 Times per week.
  4. How safe is the Portable Hyperbaric Oxygen Chamber?
    • Pure oxygen under pressure is extremely flammable. Monoplace hard chambers use pure oxygen under pressure, so safety precautions must be taken when using these chambers. While our chamber uses pressurized room air with an oxygen oncentrator. Hence it is safe and not flammable. However, the chamber should not be exposed to any naked flame, cigarette or the like.
  5. Are there any side effects?
    • The most common side effect is discomfort in the ears caused by pressure changes. To minimize the risk, patients learn to promote the adequate clearing of their ears during pressurization. Some patients may feel tired and dizzy after using hyperbaric chamber for the first time. It`s a good signal as Hyperbaric Oxygen Therapy will speed up the metabolism of our body, just like people feel tired after a long run. They are usually good signs of indicating detoxification.
  6. Do I need a prescription or supervision to use the chamber?
    • No, you do not need a prescription to use the Portable Hyperbaric Chamber. If you are using the chamber to treat your health condition, we recommend you seek advice from your health practitioner. The Portable Hyperbaric Chamber is easy to use without the need for any supervision or specialized training. Pressure gauges and pressure release valves come standard in the interior of the chamber, pressure gauge at 0kPa and the zipper is double-sided for easy and fast exiting if required.
  7. Are there any contraindications for Hyperbaric Oxygen Therapy?
    • Never use the chamber when you catch a cold or flu symptoms. Never use the chamber if you have rhinitis or otitis media. Never use the chamber if you are pregnant.

Faults and Troubleshooting

If your chamber fails to operate properly, please refer to the troubleshooting chart on the following pages for possible causes and solutions. If the problems still can’t be solved, please contact your equipment provider.

Trouble Causes Solution

Chamber pressurization very slow

|

1. Air compressor joint or air inlet joint loose or crack

2. Air filters full of dust

3. Air inlet on the air compressor is clogged, no smooth intake

4. Air compressor screws loose

5. Air deflate valve did not tighten up

|

1. Make sure there are no cracks or loose parts, and reinstall the joints

2. Replace new filters or clean the dust on the filters

3. Clean the air inlet part of the air compressor 4. Tighten up the screws on air compressor 5. Tighten up the air deflate valve

Pressure does not go to hold at proper kPa

|

1. Didn’t close the zippers

2. Didn’t close the air deflate valve or didn’t tighten up

3. Air tube does not stick in the connector 4. The blue silicon sealing strip between

the inside and outside zippers is not flat

|

1. Depressurize the chamber first, then close the zippers and restart

2. Make sure no cats and dogs in the valve holes, then close the valve and tighten it up.

3. Stick the air tube in the connector 4. Make the blue sealing strip is flat

Noisy sound or intense vibration of air compressor

|

1. The air filter is clogged

2. The air inlet on the air compressor is clogged, no smooth intake

3. Air compressor screws loose

|

1. Replace the filters

2. Clean the air inlet part of the air compressor 3. Tighten up the screws on the air compressor

The chamber does not swell at all

|

1. Air tube might fall off, air leakage 2. Didn’t close the air deflate valve

or didn’t tighten up

3. There is air leakage on the air compressor

|

1. Find out the leakage source, stick the air tube in the connector

2. Close the valve and tighten it up. 3. Reconnect the air tube to the connector

of the air compressor

Condition for Transportation and Storage

  • Environment temperature scale: -10℃-40℃
  • Comparative humidity scale: 30%-85%
  • Air pressure scale: 700hPa-1060hPa

Warranty

Our products come with a one-year warranty from the date of delivery. During the warranty period, if there are any faulty materials &/or workmanship on the equipment under correct operation, new necessary components or products will be offered for repairing or replacement FREELY. This warranty does not cover shipping costs to and from Shanghai Baobang.

CONTACT INFORMATION

  • Hyperbaric oxygen, healthy life
  • Whatapp/Tel: +86 18017023916
  • Email: Rachel@macy-pan.com
  • Address: Bldg 15, No.889 Guinan Road, Songjiang District, Shanghai, China 201617
  • Web: www.macypan.com

References