STEEL GREEN MANUFACTURING SG54 Zero Turn Sprayer Instruction Manual
- June 1, 2024
- STEEL GREEN MANUFACTURING
Table of Contents
STEEL GREEN MANUFACTURING SG54 Zero Turn Sprayer
Specifications:
- Model: SG54
- Manufacturer: Steel Green Mfg.
- Address: 824 S State Road 39 Lebanon, IN 46052
- Phone: (756)-481-2890
- Website: www.steelgreenmfg.com
Product Usage Instructions
-
Step A:
Begin by locating the tee fitting from the supply side. -
Step B:
Connect the tee fitting to the proper control valve (loop). -
Step C:
Follow the instructions for component C. -
Step D:
Proceed with the guidelines for component D. -
Step E:
Complete the process by addressing component E. -
HSA Valve:
Refer to the specific instructions for the HSA Valve.
FAQ (Frequently Asked Questions):
-
Q: Where can I find more information about the SG54 Hydraulic System Update?
A: For additional details and support, please refer to the official Steel Green Mfg. website or contact their customer service. -
Q: What should I do if I encounter any issues during the installation process?
A: If you face any challenges or have questions, contact Steel Green Mfg. for assistance. Ensure safety precautions are followed at all times.
INSTRUCTION MANUAL
HYDRAULIC SYSTEM UPDATE
Models: SG54
SG54 HYDRAULIC SYSTEM UPDATE INSTRUCTIONS
-
STEP 1 : Drain the hydraulic oil from the machine.
NOTE: Refer to the hydraulic oil change manual. -
STEP 2: Remove the loop hose on the hydraulic pump.
- Disconnect the supply hose from the hydraulic pump.
- Disconnect the other end at the hsa valve & remove the hose.
- Disconnect the return hos from the hydraulic pump.
- Disconnect the other end at the hsa valve & remove the hose.
-
STEP 3:
Remove the flow restrictor from the return side & the tee fitting from the supply side.- Loosen & rotate the return tee fitting so it faces the left side panel.
- Retighten the fitting.
- Loosen & reposition the elbow fittings as shown. Angle the supply fitting towards the front of the machine & face the return elbow straight down.
-
STEP 4:
Drill (2) holes in the left side panel.- Attach the hopper control valve to the panel.
- NOTE: The fittings on the valve are shipped loose to allow for easier hose attachment. BE SURE to tighten all the fittings once hoses are connected.
-
STEP 5:
Connect (1) of the 1/4”x 10-1/2” hoses with to the hop-per control valve (loop).- Connect one end of the other 1/4” x 10-1/2” hose to the return on the hsa valve.
- Connect the other end to the tee fitting on the hydraulic pump.
- Connect the elbow end of the 1/4” x 13” hose with to the return tee fitting on the hopper control valve.
- Connect the other end to the tee fitting on the hydraulic pump.
- Connect the elbow end of the 1/4” x 14-1/2” hose to the supply tee fitting on the hopper control valve.
- Connect the other end to the elbow fitting on the hydraulic pump.
- Connect the straight end of the 1/4” x 7-1/4” hose to the hopper control valve & the elbow end to the hsa valve
-
STEP 6:
- Refill the hydraulic oil to the full line. with 10w30 full synthetic.
- Jack up the rear of the machine so the rear tires are off of the ground.
- Start and run the machine in forward and reverse to cycle the hydraulic oil back through the system, the oil level will drop in the reservoir.
- Ounce the oil level has dropped, refill the reservoir to the full line and reinstall the cap.
MADE IN THE USA