BOSCH Quigo Green Cross Line Laser Level User Manual

May 15, 2024
Bosch

BOSCH Quigo Green Cross Line Laser Level

Product Information

Specifications

  • Model: Quigo Green
  • Manufacturer: Robert Bosch Power Tools GmbH
  • Country of Origin: Germany
  • Wavelength: 500-540nm
  • Power Output : <5mW
  • Weight: 0.27kg
  • Battery Type : 1/4
  • Battery Life: Minimum of 5 hours

Product Usage Instructions

Components

  • (1) 1/4-Inch Adapter Plate Receptacle
  • (2) Fine Adjustment Screw of the Adapter Plate
  • (3) Adapter Plate
  • (4) On/Off Switch

Mounting and Battery Installation

  1. Insert or replace batteries according to the provided instructions.
  2. Mount the measuring tool on a stable surface, holder (16), or tripod (6).
  3. Ensure the measuring tool is level and secure.

operation

  1. Turn on the measuring tool using the On/Off switch.
  2. Align the tripod roughly before switching on the tool.

Maintenance and Service

  • Regularly clean and maintain the measuring tool for optimal performance.
  • Contact customer service for any maintenance or application-related queries.

FAQ

  • Q: How do I identify my Quigo Green measuring tool?
  • A: The serial number (11) on the type plate serves as a unique identifier for your measuring tool.
  • Q: What should I do if the laser warning sign on my tool becomes unrecognizable?
  • A : Ensure the laser warning sign remains visible at all times. If it becomes unrecognizable, contact qualified personnel for assistance.

Safety Instructions

All instructions must be read and observed in order for the measuring tool to function safely. The safeguards integrated into the measuring tool may be compromised if the measuring tool is not used in accordance with these instructions. Never make warning signs on measuring tools unrecognisable. SAVE THESE INSTRUCTIONS FOR FUTURE REFERENCE AND INCLUDE THEM WITH THE MEASURING TOOL WHEN TRANSFERRING IT TO A THIRD PARTY.

Do not direct the laser beam at persons or animals and do not stare into the direct or reflected laser beam yourself. You could blind somebody, cause accidents or damage your eyes.

  • If laser radiation hits your eye, you must close your eyes and immediately turn your head away from the beam.
  • Do not make any modifications to the laser equipment.
  • Do not use the laser goggles (accessory) as protective goggles. The laser goggles make the laser beam easier to see; they do not protect you against laser radiation.
  • Do not use the laser goggles (accessory) as sunglasses or while driving. The laser goggles do not provide full UV protection and impair your ability to see colours.
  • Have the measuring tool serviced only by a qualified specialist using only original replacement parts? This will ensure that the safety of the measuring tool is maintained.
  • Do not let children use the laser measuring tool unsupervised. They could unintentionally blind themselves or other persons.
  • Do not use the measuring tool in explosive atmospheres which contain flammable liquids, gases or dust. Sparks may be produced inside the measuring tool, which can ignite dust or fumes.

Keep the magnet away from implants and other medical devices, e.g. pacemakers or insulin pumps. The magnet generates a field that can impair the function of implants and medical devices.

  • Keep the measuring tool away from magnetic storage media and magnetically sensitive devices. The effect of the magnets can lead to irreversible data loss.

Product Description and Specifications

  • Please observe the illustrations at the beginning of this operating manual. Intended Use
  • The measuring tool is intended for determining and checking horizontal and vertical lines.
  • The measuring tool is suitable for indoor use.
  • This product is a consumer laser product following EN 50689.

features

Product features

The numbering of the product features shown refers to the illustration of the measuring tool on the graphic page.

BOSCH-Quigo-Green-Cross-Line-Laser-Level-FIG-1BOSCH-Quigo-Green-Cross-Line-Laser-Level-FIG-2

  1. 1/4″ mount of the adapter plate
  2. Fine adjustment screw of the adapter plate
  3. Adapter plate
  4. On/off switch
  5. Laser beam outlet aperture
  6. Tripods)
  7. Laser viewing glasses)
  8. 1/4″ tripod mount
  9. Battery compartment cover
  10. Laser warning label
  11. Serial number
  12. Battery compartment cover locking mechanism
  13. 1/4″ screw of the holder
  14. Locking screw of the holder
  15. Fastening screw of the holder
  16. Holder

Accessories shown or described are not included with the product as standard. You can find the complete selection of accessories in our accessories range

Technical data

BOSCH-Quigo-Green-Cross-Line-Laser-Level-FIG-8

  • The working range may be reduced by unfavourable environmental conditions (e.g. direct sunlight).
  • At 20–25 °C
  • The values stated presuppose normal to favourable environmental conditions (e.g. no vibration, no fog, no smoke, no direct sunlight). Extreme fluctuations in temperature can cause deviations in accuracy.
  • Only non-conductive deposits occur, whereby occasional temporary conductivity caused by condensation is expected.

The serial number (11) on the type plate is used to clearly identify your measuring tool

Assembly

Inserting/changing the batteries
It is recommended that you use alkaline manganese batteries to operate the measuring tool. Push the locking mechanism (12) in the direction of the arrow to open the battery compartment cover (9) and remove the battery compartment cover. Insert the batteries supplied. When inserting the batteries, ensure that the polarity is correct according to the illustration on the inside of the battery compartment. If the batteries become weak, the laser lines will flash quickly for a few seconds. Always replace all the batteries at the same time. Only use batteries from the same manufacturer and which have the same capacity.

  • Take the batteries out of the measuring tool when you are not using it for a prolonged period of time. The batteries can corrode and self-discharge during prolonged storage in the measuring tool.

Operation

Starting Operation

  • Protect the measuring tool from moisture and direct sunlight.
  • Do not expose the measuring tool to any extreme temperatures or variations in temperature. For example, do not leave it in a car for extended periods of time. In case of large variations in temperature, allow the measuring tool to adjust to the ambient temperature before putting it into operation. The precision of the measuring tool may be compromised if exposed to extreme temperatures or variations in temperature.
  • Avoid substantial knocks to the measuring tool and avoid dropping it. Damaging the measuring tool can cause accuracy to be compromised. If the laser line is subjected to a substantial knock or is dropped, check it by comparing it to a known horizontal or vertical reference line.
  • Switch the measuring tool off when transporting it. The pendulum unit is locked when the tool is switched off, as it can otherwise be damaged by big movements.

Switching on/off

  • To switch on the measuring tool, push the on/off switch (4) up. Immediately after switching on, the measuring tool sends two laser lines out of the outlet aperture (5).
  • To switch off the measuring tool, push the on/off switch (4) downward over the laser beam outlet aperture (5).

Never leave the measuring tool unattended when switched on, and ensure the measuring tool is switched off after use. Others may be blinded by the laser beam.

Automatic levelling
Position the measuring tool on a level, firm surface or attach it to the holder (16) or the tripod (6). To work with automatic levelling, the underside of the measuring tool needs to be horizontal and aligned with the tripod mount (8) facing down. After switching on, the automatic levelling function automatically compensates for irregularities within the self-levelling range of±4°. The levelling is finished as soon as the laser lines stop flashing. If automatic levelling is not possible, e.g. because the underside of the measuring tool deviates by more than 4° from the horizontal plane or the measuring tool is held freely in the hand, the laser lines will continuously flash slowly and the measuring tool will work without automatic levelling. The laser lines remain switched on, but the two intersecting lines will no longer necessarily be perpendicular to each other. To make sure that the two laser lines are still perpendicular to one another, position the measuring tool at an angle of 90° to the wall. In case of ground vibrations or position changes during operation, the measuring tool is automatically levelled again. Upon re- levelling, check the posi-tion of the horizontal or vertical laser line with regard to the reference points to avoid errors by moving the measuring tool.

Working Advice

  • Only the centre of the laser line must be used for marking. The width of the laser line changes depending on the distance

Attaching using the holder (see Figure A)
Using the holder (16), you can attach the measuring tool to various objects up to 10 to 60 mm thick, e.g. to vertical or horizontal boards or pipes.BOSCH-
Quigo-Green-Cross-Line-Laser-Level-FIG-3

Loosen the fastening screw (15) of the holder, position the holder in the desired location and retighten the fastening screw. Place the measuring tool with the tripod mount (8) on the 1/4″ screw (13) of the holder and tighten it to secure it on the holder applying moderate force. Do not tighten the measuring tool firmly as this could cause damage. Roughly align the holder before switching on the measuring tool. To do this, loosen the locking screw (14). Move the measuring tool into a horizontal po-sition at the required height (with the tripod mount (8) facing down). Retighten the locking screw. You can also mount the measuring tool on the holder using the adapter plate (3).

Working with the Tripod (Accessory)
A tripod offers a stable, height-adjustable support surface for measuring. Place the measuring tool with the 1/4″ tripod mount (8) on the thread of the tripod (6) or a conventional camera tripod. Tighten the measuring tool using the locking screw of the tripod.
Roughly align the tripod before switching on the measuring tool. You can also mount the measuring tool on the tripod using the adapter plate (3).

Working with the adapter plate (see figures B–C)
The adapter plate (3) makes it easier to accurately align the measuring tool with a reference point and enables you to quickly attach and detach the measuring tool. The adapter plate (3) can be mounted on the holder (16) or tripod (6).
BOSCH-Quigo-Green-Cross-Line-Laser-Level-FIG-4BOSCH-Quigo-Green-Cross-Line-Laser-Level-FIG-5

  • Holder: Place the adapter plate with the 1/4″ mount (1) on the screw (13) of the holder and tighten it to secure it on the holder applying moderate force.
  • Note : Loosen the locking screw (14) of the holder if you want to change the position of the measuring tool. If the adapter plate is turned without loosening the locking screw, the adapter plate can become loose and the measuring tool can fall off.
  • Tripod: Tighten the locking screw of the tripod in the 1/4″ mount (1) of the adapter plate.

Press the measuring tool into the adapter plate (3) so that the locking mechanisms of the adapter plate engage in the holes on two sides of the measuring tool. The adapter plate can be fastened to the bottom, back and top side of the measuring tool. Check that the measuring tool is firmly secured. When the adapter plate is mounted on the back, the height of the measuring tool can be aligned. When it is mounted on the top or bottom, the measuring tool can be aligned sideways. Turn the fine adjustment screw (2) of the ad apter plate to align the laser line with a reference point.
Laser Goggles (Accessory)
The laser goggles filter out ambient light. This makes the light of the laser appear brighter to the eye.

Maintenance and Service

Maintenance and Cleaning Keep the measuring tool clean at all times. Never immerse the measuring tool in water or other liquids. Wipe off any dirt using a damp, soft cloth. Do not use any detergents or solvents. The areas around the outlet aperture of the laser in particular should be cleaned on a regular basis. Make sure to check for lint when doing this

After-Sales Service and Application Service
Our after-sales service responds to your questions concerning the maintenance and repair of your product as well as spare parts. You can find explosion drawings and information on spare parts at: www.bosch-pt.com The Bosch product use advice team will be happy to help you with any questions about our products and their accessories. In all correspondence and spare parts orders, please always include the 10‑digit article number given on the nameplate of the product.

Great Britain

  • Robert Bosch Ltd. (B.S.C.)
  • P.O. Box 98
  • Broadwater Park
  • North Orbital Road
  • Denham Uxbridge
  • UB 9 5HJ

Disposal
Measuring tools, accessories and packaging should be recycled in an environmentally friendly mannerDo not dispose of measuring tools or batteries with household waste..

Only for EU countries:
According to Directive 2012/19/EU on waste electrical and electronic equipment and its transposition into national law, measuring tools that are no longer usable, and, according to Directive 2006/66/EC, defective or drained batteries must be collected separately and disposed of in an environmentally correct manner.
If disposed of incorrectly, waste electrical and electronic equipment may have harmful effects on the environment and human health, due to the potential presence of hazardous substances.
Only for the United Kingdom:
According to The Waste Electrical and Electronic Equipment Regulations 2013 (SI 2013/3113) (as amended) and the Waste Batteries and Accumu-lators Regulations 2009 (SI 2009/890) (as amended), products that are no longer usable must be collected separately and disposed of in an environmentally friendly manner.

CONTACT

BOSCH-Quigo-Green-Cross-Line-Laser-Level-FIG-9

1 609 92A 85F

References