ELICENT EC 2V Silent Bathroom Exhaust Fans Instructions
- May 15, 2024
- elicent
Table of Contents
ELEGANCE EC 2V
Wall Axial fans
Linea Design EC versions
EC 2V Silent Bathroom Exhaust Fans
Complies with ErP Directive 2009/125/CE and EU Regulation 1253/2014
Classification: Residential Ventilation Unit
- Energy effi cient EC motor.
- Choice of 2 low speeds at installation.
- Provides low level continuous ventilation to control condensation.
- For any domestic wet room.
- Low noise levels and running costs.
- Wall, ceiling or window (with additional window kit) installation.
- Exhausts directly to the outside (through wall, or window installation with additional window kit, or with medium length ducting – up to 6m)
- Runs continuously at pre-selected choice of two speeds (fi xed at installation)
- Patented anti-turbulence defl ectors ensure very low noise levels and optimum performance
- Energy saving ventilation
- Extremely low running costs
INSTALLATION
WALL | CEILING |
---|
|
PERFORMANCE
MODEL | m3/h | l/s | Pa | W | **dB(A)*** |
---|
EC 2V
Elegance 100 EC 2V| 97 / 49 / 30| 27 / 14 / 8| 34 / 10 / 4| 3,5 / 0,8 / 0,5|
32 / 16 / 15
Elegance 100 EC DT 2V| 97 / 49 / 30| 27 / 14 / 8| 34 / 10 / 4| 3,5 / 0,8 /
0,5| 32 / 16 / 15
Elegance 100 EC HDT 2V| 97 / 49 / 30| 27 / 14 / 8| 34 / 10 / 4| 3,5 / 0,8 /
0,5| 32 / 16 / 15
Selv 12V – DC – Selv 2v
Elegance 100 EC 2 V 12V| 81 / 49 / 30| 22,5 / 14 / 8| 24 / 10 / 4| 2 / 0,8 /
0,5| 32 / 16 / 15
Elegance 100 EC DT 2 V 12V| 81 / 49 / 30| 22,5 / 14 / 8| 24 / 10 / 4| 2 / 0,8
/ 0,5| 32 / 16 / 15
Elegance 100 EC HT DT 2 V 12V| 81 / 49 / 30| 22,5 / 14 / 8| 24 / 10 / 4| 2 /
0,8 / 0,5| 32 / 16 / 15
- Lp(A) measured at 3m in open fi eld 230V-50Hz.
CURVES
DIMENSIONS (mm)
MODEL | A | ØB | C | D | Kg |
---|---|---|---|---|---|
ELEGANCE 100 EC 2V | 160 | 98 | 80 | 38 | 0,9 |
VERSIONS
EC 2V DT – 24 hours running at low speed (selectable between 2 at
installation). Speed boosts to maximum via control switch. The maximum speed
is provided with a timer (adjustable from 0 to 30 minutes) which activation
can be delayed up to 2 minutes to avoid unnecessary night-time operation at
the highest speed. (DT option, selectable at installation).
EC 2V HDT – 24 hours running at low speed (selectable between 2 at
installation). Speed boosts to maximum automatically and/or manually:
– automatically via humidistat (adjustable from 40 to 90% of R.H). The fan
switches back to the low speed when the humidity level goes beneath the pre-
selected threshold and once concluded the pre-selected overrun via timer
(adjustable from 0 to 30 min).
– manually via control switch (remote or pull cord). The fan switches back to
the low speed once concluded the pre-selected overrun via timer (adjustable
from 0 to 30 min). The activation of the timer can be delayed up to 2 minutes
to avoid unnecessary night-time operation at the highest speed. (DT option,
selectable at installation).
All EC models (100 2 speed, 2V DT, 2V HDT) are also available in SELV version,
low voltage 12V.
Lateral intake on the whole perimeter