Danfoss 1090052 Amplifier for KEP Foot Pedal User Guide

May 15, 2024
Danfoss

Danfoss-LOGO

Danfoss 1090052 Amplifier for KEP Foot Pedal

Product Information

Specifications

  • Product Name: Amplifier, Foot Pedal
  • Model Number: 1090052
  • Manufacturer: Phased Out Products
  • Date of Issue: June 1996
  • Designed for: Danfoss foot pedal (KEP)

Electrical Characteristics

  • +8V Regulator Indicator
  • Offset Adjustment
  • Max Gain
  • +12V Power Indicator
  • Output Indicator

Typical Wiring Connections
Refer to the provided diagrams for wiring connections based on the type and number of EDCs being controlled.

Adjustments
The amplifier allows adjustments for offset and gain to customize the output levels according to requirements.

Product Usage Instructions

  1. Single Coil EDC Control: Use a Double Pole, Double Throw (DPDT) switch for changing direction.
  2. Dual Coil EDC Control: Use a Single Pole, Double Throw (SPDT) switch for changing direction. One coil of a dual coil can be wired and switched accordingly.
  3. Multiple EDCs Control: When controlling two or three EDCs, wire the coils in series or EDCs in parallel as shown in the provided wiring diagram using a DPDT switch for changing flow direction.

Frequently Asked Questions (FAQ)

Q: What is the purpose of the trim pots on the amplifier?
A: The trim pots allow users to adjust the output levels based on the position of the foot pedal for customized control.

Q: How can I control multiple EDCs using the amplifier?
A: Refer to the provided wiring diagrams for instructions on wiring multiple EDCs and using a DPDT switch for changing flow direction.

3500 Annapolis Lane North, Minneapolis, MN 55447
Telephone: 763-509-2084 Telefax: 763-559-0108

GENERAL DESCRIPTION

This amplifier is designed to work with the Danfoss foot pedal (KEP). A typical application would be controlling a variable-volume piston pump that is fitted with an Electrical Displacement Control (EDC). Trim pots on the amplifier allow the output levels to be tailored with respect to foot pedal position. An enclosure protects the internal circuit board and provides a means of mounting. The control has (3) LEDs to indicate +12 V power, +8 V regulator and output current.

DIMENSIONS

Danfoss-1090052-Amplifier-for-KEP-Foot-Pedal-FIG-
\(1\)

  1. Enclosure Base   P/N K20292
  2. Enclosure Cover P/N K20293
  3. Bushing Cable   P/N K00797
  4. Screw 6-32 x 3/8 (4)  P/N K06254
  5. Lockwasher   P/N K04773

ELECTRICAL CHARACTERISTICS

  • Supply voltage: 12 Vdc (11 to 15 volts)

  • Output current (uni-polar): maximum 160 mA with a 22 ohm load

  • Adjustments (see Adjustments):

    1. OFFSET sets start current (threshold)
    2. MAX sets maximum current output
    3. GAIN sets current output with respect to foot pedal position
      All adjustments are clockwise (< 1 turn) for increasing.
      To access the adjustments, remove the 4 cover screws.
  • Input impedence: 200K ohm

  • EMI/RFI protection

ADJUSTMENTS

Danfoss-1090052-Amplifier-for-KEP-Foot-Pedal-FIG-
\(2\)

TYPICAL WIRING CONNECTIONS

Controlling a Single Coil EDC Requires a Double Pole, Double Throw (DPDT) Switch for Changing Direction.

Danfoss-1090052-Amplifier-for-KEP-Foot-Pedal-FIG-
\(3\)

Controlling a Dual Coil EDC Requires a Single Pole, Double Throw (SPDT) Switch for Changing Direction. Also, Just One Coil of a Dual Coil can be Wired and Switched as in Above Diagram.

Danfoss-1090052-Amplifier-for-KEP-Foot-Pedal-FIG-
\(4\)

When Controlling Two or Three EDCs, They must be Wired Coils in Series/EDCs in Parallel as Shown in Diagram Below. A Double Pole, Double Throw (DPDT) Switch is Used for Changing Flow Direction of the PV.

Danfoss-1090052-Amplifier-for-KEP-Foot-Pedal-FIG-
\(5\)

3500 Annapolis Lane North, Minneapolis, MN 55447
Telephone: 763-509-2084 Telefax: 763-559-0108

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

Related Manuals