FAGERHULT Multilume Slim VTB Ceiling Light Instruction Manual

May 15, 2024
FAGERHULT

FAGERHULT Multilume Slim VTB Ceiling Light

 Multilume Slim VTB

The light source, control gear and external cable shall exclusively be replaced by the manufacturer or its designated person.

Multilume Slim VTB

Box space can be covered with insulating matting

This product may contain a component with SVHC above 0,1% w/w, according to Reach (EC 1907/2006). Visit ECHA’s SCIP database with item number as identifier, or contact reach@fagerhult.se.

It is appropriate that this information is passed on to the users of the installation.

For use in ventilated or unventilated spaces.

Multilume Slim Organic Response

Multilume Slim Organic Response

The light source, control gear and external cable shall exclusively be replaced by the manufacturer or its designated person.

Multilume Slim Organic Response

Recessed mounting box can be covered with insulating material.

It is appropriate that this information is passed on to the users of the installation.

For use in ventilated or unventilated spaces.

Multilume Slim HB

Multilume Slim HB
The light source, control gear and external cable shall exclusively be replaced by the manufacturer or its designated person.

Box space can be covered with insulating matting.

This product may contain a component with SVHC above 0,1% w/w, according to Reach (EC 1907/2006). Visit ECHA’s SCIP database with item number as identifier, or contact reach@fagerhult.se.

It is appropriate that this information is passed on to the users of the installation.

Multilume Slim TW & Organic Response VTB

The luminaire MUST be connected before plugging in the mains voltage!

The light source, control gear and external cable shall exclusively be replaced by the manufacturer or its designated person.

Luminaire must not be covered with insulating material.

Recessed mounting box can be covered with insulating material.

It is appropriate that this information is passed on to the users of the installation.

For use in ventilated or unventilated spaces.

Manufactured by Fagerhult Sweden. For UK market importer Fagerhult UK 33-34 Dolben Street, London, SE1 OUQ

 Installation instructions LED

 The product is containing electronics which may be sensitive to electrostatic discharges (ESD) as well as mechanical stress. To avoid damages, any open circuit board like LED-modules should never be directly touched by hand or by a tool. This is valid both during installation and normal maintenance.

Products marked with this symbol
The light source shall only be replaced by the manufacturer or his designated person.

Products with an external driver
Some luminaires are for use with an external LED-driver. If any other driver than standard is intended to be used it must be adapted for the luminaire. It should be with corresponding functionality (constant current resp. constant voltage) and electrical parameters.

Insulation test
In order to avoid damaging the electronic ballast or other sensitive electronic devices, the phase and neutral must be connected together before any insulation test (max 500V DC).

Automatic circuit breakers (MCB) and Residual current device (RCD)
Due to the high peak connection current MCB:s type C is recommended. Peak- current-proof RCD:s adapted for electronics are recommended. Normally a luminaire has a leakage current of 1 mA.

Luminaires for dimming
An amplifier may be required for long cable lengths or a large number of luminaires.
Digital technology permits cable lengths up to 250 metres.

Basic insulation between mains and control wiring.
Control voltage cables may be routed with mains cables if they are mains voltage insulated. National regulations should be adopted. Control voltage cables for 1-10V are polarised (+/-) and must be connected correctly to all luminaires.

If pulse switching via a momentary push button is used, the connected luminaires must due to functional reasons be equipped with DALI drivers of the same brand!

Troubleshooting
No light? Check the supply voltage. Measure the voltage at the terminal in the luminaire. For spotlights with track adapter: please check the positioning of the phase selector and the fixation to the track system.

According to REACH (EC 1907/2006) we are obliged to inform you that this product may contain a low concentration of Lead (Pb) CAS 7439-92-1. Normal instructions for safe use applies, lead does not cause harm as it is incorporated in the chemical composition in the product and is not released in normal use. Please contact reach@fagerhult.se for more information.

It is appropriate to give this information to the user of the installation.