FLASH ART ART 400 IP65 LEDbar User Manual
- June 16, 2024
- FLASH ART
Table of Contents
ART ART 400 IP65 LEDbar
User Manual
INTRODUCTION
We are glad that you have chosen LedBar 400 IP65, thereby expanding yourlighting fixtures workshop. We hope that the choice of this device will meet your expectations and stimulate creativity in subsequent lighting projects. FOR SAFETY REASONS AND TO ENSURE THE TROUBLE-FREE OPERATION, CAREFULLY READ THE INSTRUCTIONS.
SAFETY INFORMATION
WARNING! Always mount the lamp on checked, correctly assembled and
properly screwed mounting brackets.
WARNING! When clamping the fixture to a truss or other structure at any
other angle than with the yoke hanging vertically downwards, use two clamps of
half-coupler type. Do not use any type of clamp that does not completely
encircle the structure when fastened.
WARNING! Do not look directly at the light spot while the fixture is on.
IMPORTANT! Do not point strong light output from other fixtures at the
lamp, as intense illumination can damaged the display.
WARNING! Before operating, ensure that the voltage and frequency of power
supply match the power requirements of the fixture. It’s important to ground
the yellow/green conductor to earth in order to avoid electric shock. Do not
touch any wire during operation and there might be a hazard of electric shock.
To prevent or reduce the risk of electrical shock or fire, do not expose the
fixture to rain or moisture. Do not connect the device to any dimmer pack.
IMPORTANT! Unpack and check carefully there is no transportation damage
before using the fixture. In the event of ser ious operat i ng problem, stop
using the fixture immediately. Never try to repair the fixture by yourself.
Repairs carried out by unskilled people can lead to damage or malfunction.
Please contact the nearest authorized technical assistance center. Always use
the same type spare parts. Disconnect main power before servicing and
maintenance. The housing must be replaced if they are visibly damaged.
IMPORTANT! Maximum ambient temperature is: 40°C Don’t operate it5 where
the temperature is higher than this.
Please keep this User Manual for future consultation. If you sell the fixture
to another user, be sure that they also receive this instruction booklet.
UNPACKING
The following item are included inside the box:
- ART LedBar 400 IP65 (1pc)
- DMX cable (1pc)
- powerCON TRUE1 cable (1pc)
- Safety cable (1pc)
- Pins to connect devices (2pcs)
- Omega (2pcs)
- Side adapter (1pc)
- Frost with protection (1pc)
- User manual (1pc)
INSTALATION
The unit should be mounted via its screw holes on the bracket. Always ensure
that the unit is firmly fixed to avoid vibration and slipping while operating.
Always ensure that the structure to which you are attaching the unit is secure
and is able to support a weight of 10 times of the unit’s weight. Also always
use a safety cable that can hold 12 times of the weight of the unit when
installing the fixture. The equipment must be fixed by professionals. And it
must be fixed at a place where is out of the touch of people and has no one
pass by or under it. flown above the ground. Rig the fixture to a support
truss or structure using the supplied brackets and suitable clamps. Fasten a
safety cable between the support structure and the attachment point on the
fixture. The safety cable must be able to bear at least 10 times the weight of
the fixture. The fixture may be installed in any orientation, but if installed
horizontally with a downward beam-angle, water can potentially pool in the fan
wells. Under normal operation the moisture will evaporate. However, in
locations with high rainfall, you may wish to fabricate a rain shield above
the fixture, or modify the position and orientation of the fixture to minimize
pooling. Two quarter-turn brackets are supplied with the fixtre if it is to
be. it is possible to connect several devices in one smooth line using the
pins included in the set. Place the lamps you want to connect with their side
edges so that they match each other. two pins should be inserted into the
mounting holes for each connection. It is recommended to connect no more than
3 devices in a vertical line. Using the omega holder adapter, you can easily
mount the lamp vertically directly on the structure.
IMPORTANT: Remember to always secure the device with a steel safety
cable.
IMPORTANT: If any slack is detected between the hook and the device,
immediately tighten the mounting screws or skip the device during
installation.
CONNECTION
The device is equipped with the following interfaces:
- DMX (in/out): XLR 3-pin socket
- EHTERNET (in/out): RJ-45 socket
- Power (in/out): powerCON TRUE1 socket
The connection is performed using cable with XLR-female -> XLR-Male plugs OR Ethernet (RJ-45) cable.
CAUTION! At the last fixture, the DMX signal has to be terminated with a
terminator.
Solder a 120Ω resistor between signal (-) and signal (+) into a XLR plug and
plug it in the DMX output of the last fixture.
The connection is performed using power cable with powerCON TRUE1 connector
(included). The device must be operated by qualified personnel.
CAUTION! In the case of cable damage do not attempt to repair.
Replacement or repair can be made only on the manufacturer or by a person with
appropriate permissions Using lamp, the change rate of power voltage should
be within ±10%, if the voltage
is too high, it will shorten the light’s life; if it’s not enough, the lamp
will be dark.
Please restart it after turning off light for 20 minutes until full-cooling.
Frequent switching will reduce the life span of lamps and bulbs; intermittent
using will improve the life of bulbs and lamps.
IMPORTANT! The maximum number of devices connected in series via power
cable is 3 pcs.
Voltage Specyfication
Input Voltage AC | Amperage | Frequency | Total Power |
---|---|---|---|
230 [V] | 1,74 [A] | 50 [Hz] | 400 [W] |
110 [V] | 3,66 [A] | 60 [Hz] |
Set DMX Address
- To enter the MENU enter the password (if password is turned on). The password is UP, DOWN, UP, DOWN.
- Find DMX on menu, and press ENTER to enter into.
- Set needed DMX Address using the UP and DOWN buttons.
- Press ENTER to save.
- Press the MENU to exit.
Set ArtNet config
- Find NET on menu, and press ENTER to enter into.
- Go to IP ADRESS to set needed IP address (generally ArtNet works on IP range 2.x.x.x, or 10.x.x.x) on your network.
- Go to Subnet mask to choose needed Subnet mask.
- Go to SET UNIVERSES to give Control (master dimmer and shutter), and LED (pixels). Do not forget that artnet is counted from universe 0.
- Go to LedDmxAdrr to set address the first pixel. Master dimmer had main DMX address.
- Press ENTER to save.
- Enjoy your lamp with pixel mapping!
DMX CHART
FIXTURE MODES
- 11 channels – standard
- 27 channels – standard + 4 groups pixels rgBW control
- 80 channels – 20 pixels rgBW control
- 91 channels – standard + 20 pixels rgBW control
- 2-net – control only thru art-net. main dimmer, mainstroBe + 20 pixels rgBW control
FIXTURE MODE | FUNCTION | DMX VALUE | DETAILS |
---|---|---|---|
11 | 27 | 91 | 80 |
1 | * | 1 | DIMMER MASTER |
2 | * | 2 | SHUTTER MASTER |
6-130
131-180
181-229
230-249
250-255| OPEN
STROBE SLOW -> FAST
PULSE OPEN
PULSE CLOSE
RANDOM PIXEL
OPEN
3| | | RED MASTER| 0-255|
4| | | gREEN MASTER| 0-255|
5| | | BLUE MASTER| 0-255|
6| | | WHITE MASTER| 0-255|
7| | | MACRO DIMMER| 0-5
6-13
14-22
23-31
32-40
41-49
50-58
59-67
68-76
77-85
86-94
95-103
104-112
113-121
122-130
131-139
140-148
149-157
158-166
167-176
177-185
186-194
195-203
204-212| NO FUNCTION
MACRO 1
MACRO 2
MACRO 3
MACRO 4
MACRO 5
MACRO 6
MACRO 7
MACRO 8
MACRO 9
MACRO 10
MACRO 11
MACRO 12
MACRO 13
MACRO 14
MACRO 15
MACRO 16
MACRO 17
MACRO 18
MACRO 19
MACRO 20
MACRO 21
MACRO 22
MACRO 23
FIXTURE MODE| FUNCTION| DMX VALUE| DETAILS
---|---|---|---
11| 27| 91| 80| 2-NET*
7|
|
|
MACRO DIMMER
| 213-221
222-230
231-239
240-255| MACRO 24
MACRO 25
MACRO 26
MACRO 27
8| | | MACRO DIMMER SPEED| 0-255|
9| | | MACRO COLOR| 0-5
6-70
71-130
131-190
191-255| NO FUNCTION
COLOR SMOOTH FADE SLOW -> FAST COLOR CHASE SLOW -> FAST COLOR SMOOTH FADE WITH
BACKgROUND COLOR CHASE WITH BACKgROUND
10| | | DIMMER BACKgROUND| 0-255|
11| | | MACRO COLOR BACKgROUND| 0-255|
| 12| | | | RED PIXEL 1-5| 0-255|
| 13| | | | gREEN PIXEL 1-5| 0-255|
| 14| | | | BLUE PIXEL 1-5| 0-255|
| 15| | | | WHITE PIXEL 1-5| 0-255|
| …| | | | …| |
| 24| | | | RED PIXEL 16-20| 0-255|
| 25| | | | gREEN PIXEL 16-20| 0-255|
| 26| | | | BLUE PIXEL 16-20| 0-255|
| 27| | | | WHITE PIXEL 16-20| 0-255|
| | 12| 1| RED PIXEL 1| 0-255|
| | 13| 2| gREEN PIXEL 1| 0-255|
| | 14| 3| BLUE PIXEL 1| 0-255|
| | 15| 4| WHITE PIXEL 1| 0-255|
| | …| …| |
| | 88| 77| RED PIXEL 20| 0-255|
| | 89| 78| gREEN PIXEL 20| 0-255|
| | 90| 79| BLUE PIXEL 20| 0-255|
| | 91| 80| WHITE PIXEL 20| 0-255|
- IN 2-NET MODE, TWO ADDRESSES MUST BE SET.
ONE FOR THE MAIN CONTROL (GLOBAL DIMMER AND SHUTTER) IN THE MAIN MENU, THE OTHER FOR SINGLE PIXEL CONTROL IN THE NET MENU.
(!) TT WORKS ONLY WITH ART-NET PROTOCOL, AND ONLY WITH CONNECTION THRU RJ-45 CABLE Do NOT FORGET SET IP ADRRES, SUB-MASK, UNIVERSEs To RECIVE SIGNAL ff
MENU OVERVIEW
DRAWINGS
PHOTOMETRICS
SPECIFICATION =
- Light Source: 20x20W RGBW
- Total lumen output: 10000 lm
- Power consumption: 400 W
- Power supply voltage: 110-240V, 50/60Hz AC
- RGBW SECTION pixel and shapes control
- Control: DMX 512, RDM, Art-Net, Auto-running
- DMX channel mode: 11/27/80/91/2-net
- System for easy connection of elements in a line
- Additional frost
- IP Rating: IP65
- Housing made: aluminium, glass, plastic (frost)
- Cooling: Passive
- AC IN/OUT: PowerCon TRUE1
- 3-Pin XLR DMX Input/Output
- Ethercon Input/Output
- Net Weight: 9,5 [kg]
- Dimensions: 100,4 x 13 x 9,5 [cm]
FLASH-BUTRYM SP.J.
SKARBIMIERZYCE 18
72-002 DOLUJE
POLAND
WWW.FLASH-BUTRYM.PL