HORNBACH 700U07179270 D Electric Water Heater Instruction Manual

May 15, 2024
HORNBACH

HORNBACH 700U07179270 D Electric Water Heater

Warnings

This device is not intended for use by persons (including children) with physical, sensory or mental disability, or by persons lacking experience or knowledge, unless they have received from a person in charge of their safety adequate supervision or preliminary instructions on how to use the device. Children should be super-vised to ensure that they do not play with the appliance. This unit can be used by children of not less than 3 years and people with reduced physical, sensory or mental capabilities or without experience or knowledge if they are properly supervised or if the instructions for using the device safely have been given and if the risks are taking into account. Children must not play with the device. Cleaning and maintenance must not be done by children without supervision. Children aged from 3 to 8 years are only allowed to operate the tap connected to the water heater.

CAUTION
Heavy item, handle with care :

  • Install the appliance in a room which is protected from frost. If the appliance is damaged because the safety device has been blocked, it is not covered by guarantee,

  • If the appliance is to be fitted in a room or location where the ambient temperature is higher than 35°C, provide sufficient ventilation,

  • When installed in a bathroom, do not install the appliance in volumes V0 and V1 (See fig. 1, p. A). It is compulsory to fit a sump below the water heater if mounted in a suspended ceiling, under the roof or above living area. Position the appliance where it can be accessed. Refer to installation figures PAGE A.

  • Make sure that the wall on which the appliance is mounted can support the weight of the appliance when filled with water,

  • Installation of vertical wall mounted device : To replace eventually the heating element, leave free space (300 mm until 100 liters and 480 mm for higher capacities) below the ends of the tubes of the appliance.

  • This device is intended for use at a maximum altitude of 2000 m. This water heater is fitted with a thermostat with an operating temperature of more than 60°C at its maximum position, capable of reducing growth of legionella bacteria in the tank.
    Caution! Above 50°C, water could cause immediate scalds. Check the water temperature before taking a bath or shower.

  • The user must conserve this guide

WATER CONNECTIONS

  • Mandatory installation of a safety device in a frost free location (or any other new device which limits the tank pressure) to 0.7 or 0.9 MPa (7 or 9 bar) according to the nominal pressure, with a size of 3/4’’ on the input of the water heater, respecting the local regulations (see table p.B).
  • Hydraulic accessories should not be located between the safety valve and the cold water inlet. A pressure reducer (not supplied) is required when the water supply pressure exceeds 0,5 MPa (5 bar) and will be fitted on the main supply.
  • Connect the safety device to an unpressurised outlet pipe in a frost free location, with a continuous slope to evacuate water during heating up or draining the water heater.
  • Operate regularly the discharge of safety device to prevent scaling and check that it is not blocked.
  • To drain the device : switch off the power and the supply of cold water, open the hot water faucets and manipulate the safety valve,
  • The pipes used must support 1 MPa (10 bar) and 100°C.
ELECTRICAL CONNECTIONS
  • Switch off the power before removing the cover, to avoid any risk of injury or electric shock.
  • The installation must be equipped, upstream of the appliance, with a bipolar cut-out device (fuse, breaker switch) respecting local regulations (30 mA earth-leakage breaker).
  • If the supply cord is damaged, it must be replaced by a special cord or assembly available from the manufacturer or the after sales service.
  • Always connect the earth conductor of the cable to the earth ground wire or connect the earth conductor to the appropriate terminal identified by the symbol .
  • Product including a battery : there is a risk of explosion if the battery is replaced by an incorrect type of battery. Dispose waste battery according the instructions.
  • The instruction book of this product is available by contacting the after-sales service.

Installation manual

INSTALLATION (Figure 1)
It is compulsory to fit a sump below the water heater if mounted in a suspended ceiling, under the roof or above living area. A drain connected to the sewer is required.

LOCATION
INSTALLATION OF A VERTICAL WATER HEATER (Figure 2)
To enable the heating element to be replaced, leave free space below the ends of the tubes of the appliance. The appliances can be mounted on a tripod (optional) if the wall is not strong enough. It is, however, obligatory for the upper bracket of the water heater to be attached to the wall to prevent it tilting.

INSTALLATION OF A STABLE WATER HEATER (Figure 3)
The water heater must be installed absolutely vertically in such a way as to ensure perfect stability with access to its electrical parts and safety devices. Allow for access to parts which may need replacing.

HORNBACH 700U07179270 D Electric Water Heater 1

INSTALLATION OF A HORIZONTAL WATER HEATER (Figure A)
Various ways to install ; when the water heater is in place, the water connections MUST be absolutely vertical below the appliance. Allow for access to parts which may need replacing.

HORNBACH 700U07179270 D Electric Water Heater 2

WATER CONNECTIONS (Figure 5)
All water supply pipes must be thoroughly cleaned before connection. The connection to the hot water outlet must be made using a cast iron or steel sleeve or a dielectric union in order to avoid corrosion of the tubes (due to direct contact between iron and copper). A brass union must not be used.

HORNBACH 700U07179270 D Electric Water Heater 3

| EN
---|---
1| Hot water tube
2| Safety relief valve
3| Funnel – Syphon
4| Pressure reducing for pressure 0,5 MPa (5 bar)
5| Stop valve
6| Drain to sewage
7| Cold water pipe
8| Dielectric union

UNVENTED INSTALLATION
A new safety device which conforms to current standards (in Europe EN 1487), pressure 0,7 and 0,9 MPa (7 and 9 bar) and size 3/4’’ in diameter must be fitted. The safety valve must be protected from frost.
Hydraulic accessories should not be located between the safety valve and the cold water inlet. A pressure reducer (not supplied) is required when the water supply pressure exceeds 0,5 MPa (5 bar) and will be fitted on the main supply.
Connect the safety device to an unpressurised outlet pipe in a frost free environment, with a continuous slope for the evacuation of the water during heating up or draining the water heater. The pipes used must support 1 MPa (10 bar) and 100°C.
If using PER pipes, we strongly recommend that a thermostatic regulator be fitted to the water heater outlet. It will be set according to the performances of the equipment used.

ELECTRICAL CONNECTIONS (Figure 6/7 D and E)
The water heater can be connected and powered only by a single-phase 220-240 V AC or a three-phase 380-400 V mains supply according to model. Connect the water heater via a fixed duct with a cross section of 2.5 mm². Use a standard duct (fixed or ring reinforced sheath) to the calibrated receptacle in the caver. In the case of appliances fitted with a cable or a plug (not allowed in France), connect up directly.
Always connect the earth conductor of the cable to the earth ground wire or connect the earth conductor to the appropriate terminal identified by the symbol ..

HORNBACH 700U07179270 D Electric Water Heater 4

| 4h {75°C}

3h {65° C}

| Schema| 6h {75°C}

4h {65° C}

| Schema| 8h {75°C}

6h {65° C}

| Schema
---|---|---|---|---|---|---
VM| 80 L| 1500 W| 1000 W| 750 W
| 230 V

400 V

| M4

Ml

| 230 V

400 V

| MS

M2

| 230 V

400 V

| M6

M3

l00 L| 2400 W| 1600 W| 1200 W
| 230 V

400 V

| M4

Ml

| 230 V

400 V

| MS

M2

| 230 V

400 V

| M6

M3

l20 L| 2400 W| 1600 W| 1200 W
| 230 V

400 V

| M4

Ml

| 230 V

400 V

| MS

M2

| 230 V

400 V

| M6

M3

lS0 L| 3000 W| 2000 W| 1500 W
| | ****

Ml

| 230 V

400 V

| MS

M2

| 230 V

400 V

| M6

M3

400 V
200 L| 4000 W| 3000 W| 2000 W
| | ****

Pl

| | ****

P2

| 230 V

400 V

| P4

P3

400 V 3| 400 V

This connection is a vital safety feature. The green-yellow earth wire must be longer than the phase wires. The installation must be equipped, upstream of the appliance, with a bipolar cut-out device (contact opening at least 3 mm ; fuse, breaker switch.) If the ducts are made of insulating material, the electrical contacts must be protected by a 30 mA earth-leakage breaker conforming to the applicable standards. Adapt the connection to the power supply (see diagrams and table).
Before removing the cover, switch off the power.

HORNBACH 700U07179270 D Electric Water Heater 5

Thermal circuit breaker:
All our products are equipped with a thermal circuit breaker with manual resetting which shuts off the power to the water heater if it becomes overheated. If the safety device is tripped, cut the power before any operation and have the circuit breaker reset by a professional.
If the circuit breaker continues to trip, replace the thermostat. Never by- pass the safety device or the thermostat. Connect the power supply only via the terminal.
For electronic products with a power output greater than or equal to 1800 W, it is possible to switch to three-phase 400V using the Facilitri 400V kit. The modification must be made by a professional.
For products which are equipped with a mechanical thermostat and compatible with single-phase and three-phase connections, the wiring must be modified by a professional and only using the equipment supplied by the manufacturer.

COMMISSIONING / USE

Never switch the water heater on without it being filled with water.
Before switching on, open the hot water taps, bleed the pipes until no air is present and fill the appliance.
Check that the pipes and the door seal under the caver are not leaking. If there are any leaks tighten gently. Check that the water safety devices are working and fill the appliance. Switch on the appliance. After 5 to 20 minutes according to the capacity of the appliance, water should start dripping from the drain outlet. This is normal and results from the expansion of the water. Check that joints and seals are watertight. In the course of heating up, shielded water heaters may make a boiling noise ; this is normal and does not indicate any fault with the appliance.

To avoid the development of bacteria (legionella…) ensure that a temperature of 60°C is reached every day. The thermostat is set at the factory at (65°C+- 5°C. or 78+-3°C according to model).

If steam or boiling water emerges continuously from the drain plug or drain tap, switch off the electricity and call a professional.
When first powered, a smoke and an odor may be released from the heating element. This is normal and it disappears after a few minutes.

MAINTENANCE

User maintenance:
Operates once a month the discharge of water security to prevent scaling and verify that it is not blocked. If this is not done, damage may be caused and the guarantee invalidated.

Maintenance by a qualified person:

  • Remove the scale sludge. Do not scrape or chip at lime scale deposited on the casing because this may damage the lining
  • Change the magnesium anode every 2 years or when its diameter is less than 10 mm. Changing the shielded heating element or the anode requires the water heater to be drained and the seal changed.

Drain:
Turn off the power and the supply of cold water, open the hot water faucets and manipulate the safety valve before performing these operations. Refit the heating element and tighten the screws gently (opposite screws in sequence), check for leaks the next day and tighten if required.
If the supply cord is damaged, it must be replaced by a special cord or assembly available from the manufacturer or its service agent.

Replaceable parts:
The thermostat, seals, heating element, boiler shell, the indicator light, the magnesium anode, the connection cable. The guarantee requires genuine manufacturer’s parts to be used.
Do not dispose your water heater in the garbage, but hand it to a place assigned for this purpose (collection point) where it can be recycled.

SCOPE OF THE GUARANTEE

The water heater must be installed, used and maintained according to best practice and conform to the standards in force in the country in which it is installed and to the instructions contained in this document.
In the European Union this appliance is covered by the statutory guarantee accorded to consumers in accordance with directive 1999/44/CE. This guarantee comes into force when the appliance is delivered to the consumer. In addition to the legal guarantee, certain items are covered by an extra guarantee relating only to the free exchange of the tank and of components accepted as defective. It does not include the cost of replacement or carriage. Refer to the table below.

This commercial guarantee does not affect your statutory rights. It applies within the country where the product was acquired, provided it is also installed in the same country. The dealer must be informed of any damage before the product is exchanged under guarantee and the appliance will remain available for inspection by experts from the insurance company and the manufacturer.

The duration of commercial guarantee| Range| IMMERSION ELEMENT| STEATITE| ACI
---|---|---|---|---
Statutory| 2 years all parts| 2 years all parts| 2 years all parts
Extra commercial guarantee on tanks and heating elements, except for electrical components| + 3 years

(for Ireland : + 0 year)

| + 3 years

(for Ireland : + 0 year)

| + 3 years

(for Ireland : + 0 year)

Exclusions: Wear parts : magnesium anodes…. ; equipment which cannot be assessed (access difficult for repair, maintenance or assessment) ; equipment exposed to abnormal environmental conditions : frost, bad weather, water which is abnormally aggressive or outside drinking standards, electrical supply with large spikes ; equipment installed without observing current standards in the country of installation : the absence or incorrect fitting of safety devices, abnormal corrosion due to incorrect water fitments (iron/copper contact), incorrect earthing, inadequate cable thickness, non observance of the connection drawings shown in these instructions ; equipment not maintained in accordance with these instructions ; repairs or replacement of parts or components in the equipment not carried out or authorised by the company responsible for the guarantee.

These devices comply with the directive 2014/30/UE according to electromagnetic compatibility, 2014/35/UE according to low voltage, 2015/863/UE according and 2017/2102/UE to ROHS directive and Commission Delegated Regulation 2013/814/UE supplementing 2009/125/EC regulation for ecodesign.