1. Initial Inspection

Inspect the product for any damage during transit. Do not power
the product ON until inspection is complete.

Check for the following items in the box:

  • Wireless Charger
  • Cables (shipped separately in the accessories box)

2. Safety Guidelines

All personnel involved in the installation, use, or maintenance
of this product must read and understand the provided safety
information in the manual.

WARNING: Use only a dry chemical powder fire
extinguisher if the product is exposed to flame or fire. Using a
wet chemical fire extinguisher can conduct electricity and cause an
electric shock.

3. Product Features

Top Panel

  • Wireless Charger: For charging compatible electronic
    devices.

Front Panel

  • 12VDC Output Sockets (MAX 2A)
  • 12VDC Output Anderson Plug (MAX 30A)
  • 12VDC Output Cigarette Lighter Socket (MAX 10A)
  • 5VDC Output USB/TYPE C Charger
  • 120V AC Output NEMA 5-20R outlets (Max 20A)
  • 120V AC Output NEMA TT-30R Outlet (Max 25A)
  • 120V Alternate AC Output Outlet (Max 25A)
  • Touchscreen
  • Indicator Light
  • Air Vent (removable for cleaning)

Back Panel

  • 120V AC Input Port LP-28 (Max 30A)

  • Inverter Reset Switch

  • AC Output parallel communication port (For AC output parallel
    setup)

  • Expansion Battery Port 1

  • Expansion Battery Port 2

  • AC Input Reset Switch

  • 12/24VDC Input Port (Max. 10A)

  • Power Switch (for Battery BMS)

  • Solar Input Port (Voc. Range 120V DC ~ 500V DC, Max. Charging
    Power 4,400W, Max. Total Input for Charging+Inverter
    5,000W/18A)

Frequently Asked Questions (FAQ)

Q: What should I do if I encounter issues with charging my

devices using the wireless charger?

A: Ensure that the compatible electronic device is properly
aligned on the wireless charger for efficient charging. If issues
persist, contact customer service for further assistance.

Q: Can I connect multiple devices to the AC outputs

simultaneously?

A: Yes, you can connect multiple devices to the AC outputs as
long as the total combined load does not exceed the specified
maximum current ratings for each outlet.

“`

User Manual
Portable Solar Power Station
Apollo 5K

Hysolis Apollo 5K Manual – Primary V20240108P.indd 1

1/8/24 9:58AM

Contents
1.0 Introduction . . . . . . . . . . . . . . . . . . . . . . . . . 1 2.0 Safety . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2 3.0 Initial Inspection . . . . . . . . . . . . . . . . . . . . .3 4.0 Product Features . . . . . . . . . . . . . . . . . . . 4
4 .1 Top Panel . . . . . . . . . . . . . . . . . . . . . . 4 4 .2 Front Panel . . . . . . . . . . . . . . . . . . . . 4 4 .3 Back Panel. . . . . . . . . . . . . . . . . . . . . 5 4 .4 Homepage UI Touchscreen . . . . . 6 4 .5 Homepage UI Icons. . . . . . . . . . . . . 7 5.0 Installation . . . . . . . . . . . . . . . . . . . . . . . . . 8 5 .1 Overview . . . . . . . . . . . . . . . . . . . . . . 9 5 .2 General Installation Guidelines 9 5 .3 Single Unit Options. . . . . . . . . . . . . 9 6.0 Operation . . . . . . . . . . . . . . . . . . . . . . . . . . . 17 6 .1 Power-on Options. . . . . . . . . . . . . .17 6 .2 Touchscreens . . . . . . . . . . . . . . . . . 21 7.0 Product Care . . . . . . . . . . . . . . . . . . . . . . . 37 8.0 Troubleshooting . . . . . . . . . . . . . . . . . . . 37 9.0 Technical Specifications . . . . . . . . . . . . .41 10.0 Declarations . . . . . . . . . . . . . . . . . . . . . . . 42 11.0 FCC Compliance Statement . . . . . . . . . 43 12.0 IC Notice . . . . . . . . . . . . . . . . . . . . . . . . . . . 44
Hysolis Apollo 5K Manual – Primary V20240108P.indd 2

1/8/24 9:58AM

1.0 Introduction

1

12VDC

2VDC MAX 30
PD60W 5V 2.4A QC 3.0 PD60W

A

MAX 30A
12VDC 2A

AC OUTPUT MAX 15A

AC OUTPUT MAX 25A

ALTERNATE AC OUTPUT MAX 25A

Thank you very much for purchasing the
Hysolis Apollo 5K unit! We designed this product to help grant you energy independence. We have the utmost confidence in this product’s performance and quality. Please feel free to contact us at Hysolis .com if you have any questions. Enjoy using your Hysolis Apollo 5K, and may it positively affect your future endeavors!

The product has the following features: · Dual-CPU Intelligent Control Technology manages energy input/output · High-frequency pure sine wave output is clean and reliable for any load · Wide input voltage range and consistent voltage output · Three programmable working modes prioritize different energy needs:
· UPS mode: Utility Power first, a.k.a. “Pass-through AC Power” · AC Fast Charge (AC F .C .) mode: 120V AC power Fast Charge,
600W-3,000W (5A – 25A) programmable · Battery First mode: The solar charges the battery and grid. AC Power is
only used if battery is almost empty. · Intelligent MPPT solar controller features over-charge & over-discharge
protection, current limiting charging, and multiple other safety protections · Battery over-voltage and low-voltage protection, overload protection, short
circuit protection, over-temperature and under-temperature protection. · A 4.3″ touchscreen shows real-time running statuses at-a-glance · Remote monitoring and control · Compact and modular unit design for portability · Smart Fan Control keeps the unit cool, safe, and reliable · Multiple output power supply (120VAC/3000W, 12VDC/600W, 5VDC/120W) · Unattended mode: If battery runs out, inverter auto-starts when solar power
is available.

1

Hysolis Apollo 5K Manual – Primary V20240108P.indd 1

1/8/24 9:58AM

2.0 Safety

All personnel engaged with installation, use, or maintenance of this product must read, and understand the information in this manual. Please contact customer service if there are any questions before operating this product.
WARNING
· Inserting foreign objects into any of the product’s port or ventilation holes may cause an electrical shock and result in death or serious injury. Never insert foreign objects into any of the product’s port or ventilation holes.
· Improper connections between the unit and the power source may result in exposure to electricity and could result in death or serious injury. A licensed electrician is required to install the Apollo 5K as spacing installation involves connecting the wires from your home circuit breaker box to the Apollo 5K Wiring Box (optional purchase).
· Placement of the product near any heat sources may result in an explosion or toxic fumes and could result in death or serious injury. Never place and operate the product in an environment with flammable, explosive gas, or smoke.
· Operation of the product in wet conditions may conduct electricity and expose people and animals to electric shock resulting in minor injury or death. Always turn the power to the unit OFF if is operating in wet conditions. Let the unit dry completely and ensure the unit is in a safe environment before turning the power to the unit on.
· This product utilizes high voltage solar array to charge. Exercise extreme caution when handling high-voltage PV (solar) wires. Do not use if wires are damaged. Use included Solar Input Breaker to connect to Apollo.
· Voltage may be present on PV (solar) Input when inverter is in operation.

CAUTION
Only use a dry chemical powder fire extinguishing agent if the product is exposed to flame or fire. Using a wet chemical fire extinguisher can conduct electricity and cause an electric shock and may result in minor or moderate injury as well as damage the product.
2

Hysolis Apollo 5K Manual – Primary V20240108P.indd 2

1/8/24 9:58AM

NOTICE
· Ensure proper ventilation while in use and do not obstruct fan openings. Inadequate ventilation may cause permanent damage to the equipment.
· Vibrations and impacts during product operation may damage the unit and lead to poor connectivity to the hardware inside. Do not move the product during operation.
· Stacking anything on top of the power station either in storage or while in use may cause damage the product. Do not stack anything on the product.
· Replacement of the internal battery or any other components of product by anyone other than authorized personnel may result in damage to the product. Always have authorized personnel perform hardware maintenance.
3.0 Initial Inspection

NOTICE

Inspect the product for damage during transit. Do not power the product ON.

Check the following items are in the box (Note: Cables are shipped separately in the accessories box):

· AC charging cable

· Ground cable and spike

· DC charging cable · Solar Input Breaker
Hysolis Apollo 5K Manual – Primary V20240108P.indd 3

· Wall-Outlet Adapter for AC charging cable
· User Manual · Apollo 5K Unit Report any damage to the product to the dealer and carrier. Contact Hysolis customer service regarding any missing items: Phone: +1 (760) 410-5917 Email: support@hysolis.com 3
1/8/24 9:58AM

4.0 Product Features
4.1 Top Panel
1 . Wireless Charger Note: The wireless charger can be used to charge compatible electronic devices.

4.2 Front Panel

2 . 12VDC Output 5210 Sockets (MAX 2A)

3 . 12VDC Output Anderson Plug (MAX 30A)

4 . 12VDC Output Cigarette 4
Lighter Socket (MAX 10A)
5 . 5VDC Output USB /TYPE 5
C Charger

6 . 120V AC Output NEMA

5-20R outlets

6

(Max 20A)

7 . 120V AC Output NEMA TT-30R Outlet (Max 25A)

8 . 120V Alternate AC Output Outlet (Max 25A)

9 . Touchscreen

10 . Indicator Light

11 . Air Vent (removable for cleaning)

Hysolis Apollo 5K Manual – Primary V20240108P.indd 4

1

1

Fig. 4 .1 · Unit top view

32

12VDC

2VDC MAX 30
PD60W 5V 2.4A QC 3.0 PD60W

A

MAX 30A
12VDC 2A

AC OUTPUT MAX 15A

AC OUTPUT MAX 25A

ALTERNATE AC OUTPUT MAX 25A

10 9 7 8
11

Fig. 4 .2 · Unit front panel 4

1/8/24 9:58AM

4.3 Back Panel

12 . 120V AC Input Port LP-28 (MAX 30A)

13 . Inverter Reset Switch

14. AC Output parallel
communication port 12

(For AC output parallel

set up)

13

15 . Expansion Battery

Port 1

14

16 . Expansion Battery

Port 2

17 . AC Input Reset Switch 15
18 . 12/24VDC Input Port (Max. 10A)

19 . Power Switch

16

(for Battery BMS)

20 . Solar Input Port (Voc. Range 120V DC ~ 500V DC, Max. Charging Power 4,400W, Max. Total Input for Charging+Inverter 5,000W/18A)

21 . BMS Working Status Indicator

22 . Ground Port

23 . BMS Reset Button

I n v e r te AC Inp

17

S witch S witch

MAX · 35A AC INPUT

r R eset

ut R es et

COM1

COM2

AC OUTPUT

COMM.PORT

12V/24V MAX · 10A DC INPUT

BATTERY 1 51.2VDC

CAUTION!
SWITCH BATTERIES OFF BEFORE CONNECTING OR DISCONNECTING BATTERY CABLES.
CAUTION!
ONLY CONNECT HYSOLIS 5K BATTERIES. DO NOT USE 3RD-PARTY BATTERIES. CONNECTING THE WRONG BATTERY MAY DAMAGE THE UNIT AND/OR HARM THE USER.

BATTERY 2 51.2VDC

Battery Switch
NOTICE! DISCONNECT ALL INPUT AND OUTPUT CABLES BEFORE SWITCHING ON OR OFF. BATTERY MAY ALWAYS BE LEFT ON EXCEPT FOR SHIPPING OR STORAGE.
RESET

SOLAR INPUT 120V~450V
MAX.4400W(18A)
DANGER! VOLTAGE MAY BE PRESENT ON PV INPUT WHEN INVERTER IS OPERATING..

RUN ALM

CHARGE

18
19 20
21 22

23
Fig. 4 .3 · Unit back panel

5
Hysolis Apollo 5K Manual – Primary V20240108P.indd 5

1/8/24 9:58AM

4.4 Homepage UI Touchscreen

efg

h

a
Home
b
Settings
c
Information
d
Alerts

11/15/XXXX 15:15

PV 120VAC 12VDC

2560 W

2560 W

2500 W 120 W

330 W

100%

AC Load AC ON
DC Load DC OFF

i j
k l

m
Fig. 4 .4 · Homepage UI touchscreen features

a . Homepage Button: Press to return to the Homepage UI touchscreen b . Setting Screens Button: Press to access the Settings screens c . Information Screens Button: Press to access the Information screens d . Alert Screen Button: Press to access the current Alert screen e . PV (solar) Button: Press to access the PV Input information screen f . AC Button: Press to access the AC Input information screen g . Battery Button: Press to access the Battery information screen h . Date & Time: Displays current Date and Time i . AC Load Button: Press to access the AC Output information screen j . AC Output On/OFF Switch: Toogle to turn AC Output ON or OFF k . DC Load Button: Press to access the DC Output information screen l . DC Output ON/OFF Switch: Toggle to turn DC Output ON or OFF m . DC Button: Press to access the DC Charge information screen

6
Hysolis Apollo 5K Manual – Primary V20240108P.indd 6

1/8/24 9:58AM

4.5 Homescreen UI Icons

b cd

h

i

a

g

11/15/XXXX 15:15

Home Settings

ef

2560 W

2560 W

ECO

PV

AC Load

2500 W

AC ON
j

Data

120VAC

120 W

330 W

k

100%

12VDC

DC Load DC OFF

Warnings

Fig. 4 .5 · Homepage UI touchscreen icons a . AC/DC Status: The unit is charging.

b . Battery Status Indicator: Battery charge level.
c . Bluetooth Indicator (connected): The unit is connected to Bluetooth.
d . Bluetooth Indicator (not connected): The unit is not connected to Bluetooth.
e . WiFi Status (connected): The unit is connected to a WiFi network. f . WiFi Status (ready to connect): The WiFi settings have been reset
and the device is ready to connect to a WiFi network. g . WiFi Status (connecting): The unit is connecting to Bluetooth.
ECO h . Energy Saver Mode Status: Energy saver mode is on.
i . Inverter Status (disconnected): The inverter is disconnected, click to power on the inverter.
j . Unattended Mode Status: Unattended mode is on.

k . Inverter Status (disconnected): Inverter may not be used when using AC F.C. mode greater than the default value.
7

Hysolis Apollo 5K Manual – Primary V20240108P.indd 7

1/8/24 9:58AM

5.0 Installation
Important! A licensed electrician is required to install the Apollo 5K in any hardwired fashion. An Apollo 5K Wiring Box (Optional Purchase) may be used in the installation. For all configurations, please consider the rated amperages of power sources, total loads, wires, and the Apollo 5K. Do not exceed limits.
The Apollo 5K factory default setting is “floating neutral” (i.e. the neutral and ground are unbonded.
The unit should be configured with floating neutral when connecting the load side of the Apollo to a separate ground (e.g. directly supplying power to a home breaker panel).
The unit may be configured with a neutral-ground bond, a.k.a. “bonded neutral”, which may be preferred for some off-grid applications. To bond the neutral to the ground, please follow instructions according to the label on the side panel of the Apollo as depicted in Fig. 5.1 and Fig. 5.2 below.
The Apollo ground port may be connected to a grounding rod, building rod, etc. by a qualified electrician. Ensure the Apollo neutral-ground is appropriately bonded or unbonded.

Fig. 5 .1 Neutral-Ground Separated / Floating Neutral (Factory Default): The Neutral wires to the plastic pole
Fig. 5 .2 Neutral-Ground Bonded: The Neutral wires to the metal structure
8
Hysolis Apollo 5K Manual – Primary V20240108P.indd 8

Switch t Switch

1AM1CA0VIXN/1P32U50ATV

1SM2O0ALVXA~R455I00N0VP0DUWCT

MD1CA2XVIN/2P14U0VAT

Reset Rese

AC Input Inverter

COM2 COM1
AC OUTPUT COMM.PORT

MBEDODXEAOFAPMNSBNAUUAAONGTPFTSATPEWICECLOTAROITNEHRYUNDEBN!RNWABIWUENTYRCRHGTOTT.OE!HNRLDEEGYIFOUPBFRANEAICRTIGTTEK.INENTMRAHTUYLETSMYTPAEY

RESET

B5A1T.T2EVRDYC 2

B5A1T.T2EVRDYC 2

RUN ALM

CHARGE

1/8/24 9:58AM

5.1 Overview
There are two installation options. These include Single Unit setup and Multi- unit setup. Refer to the Apollo 5K Expandability Manual for Multi-unit setup instructions. The power sources for each option include:
· AC input (i.e. utility power or generator)
· DC input (i.e. automobile with DC output)
· PV input (i.e. solar photovoltaic panels)
· Both setups provide AC and DC output.

5.2 General Installation Guidelines
During transport, the unit may have warmed or cooled outside of its working temperature range. Moisture may have condensed on the unit. Ensure it is dry and within the proper temperature range before using.
· Do not use the product in a wet or dusty environment.
· Do not use anything flammable or explosive near the product.
· Do not cover or block the vents in the product.
· Maintain 4 inches (10cm) of clear space around the unit to have good heat dissipation.

5.3 Single Unit Options

This section provides an overview of the single unit options. It shows input power options (Fig. 5 .3), possible ouput capabilties, and describes the input and output power parameters for AC, DC, and PV (solar) input and AC, DC output.

INPUT

OUTPUT

PV Utility Generator

1

12VDC

2VDC MAX 30
PD60W 5V 2.4A QC 3.0 PD60W

A

MAX 30A
12VDC 2A

AC OUTPUT MAX 15A

AC OUTPUT MAX 25A

ALTERNATE AC OUTPUT MAX 25A

Vehicle
Fig. 5 .3 Power options and output capabilities 9

Hysolis Apollo 5K Manual – Primary V20240108P.indd 9

AC Loads
DC Loads
1/8/24 9:58AM

5 .3 .1 Single Unit: 120V AC Input

Acceptable 65V~140VAC (for home appliances) Voltage Range 95V~140VAC (for computers)

Frequency 60Hz / 50Hz (auto-sensing)

Maximum Current

30A (3,600 watts)

Table 5 .1 Single unit – 120V AC input power parameters

INPUT PORT

Utility power Generator

I n v e r te AC Inp

MAX · 35A AC INPUT

r R eset

ut R es et

COM1

COM2

AC OUTPUT

COMM.PORT

S witch S witch

12V/24V MAX · 10A DC INPUT

BATTERY 1 51.2VDC

CAUTION!
SWITCH BATTERIES OFF BEFORE CONNECTING OR DISCONNECTING BATTERY CABLES.
CAUTION!
ONLY CONNECT HYSOLIS 5K BATTERIES. DO NOT USE 3RD-PARTY BATTERIES. CONNECTING THE WRONG BATTERY MAY DAMAGE THE UNIT AND/OR HARM THE USER.

BATTERY 2 51.2VDC

Battery Switch
NOTICE! DISCONNECT ALL INPUT AND OUTPUT CABLES BEFORE SWITCHING ON OR OFF. BATTERY MAY ALWAYS BE LEFT ON EXCEPT FOR SHIPPING OR STORAGE.
RESET

SOLAR INPUT 120V~450V
MAX.4400W(18A)
DANGER! VOLTAGE MAY BE PRESENT ON PV INPUT WHEN INVERTER IS OPERATING..

RUN ALM

CHARGE

Fig. 5 .4 Single unit – 120V AC input port and cable

10
Hysolis Apollo 5K Manual – Primary V20240108P.indd 10

1/8/24 9:58AM

5 .3 .2 Single Unit: 120V AC Output

Voltage Range

120VAC (+/-5%) 60Hz / 50Hz (auto sensing)

Wave Form Pure sine wave

Rated Current

25A (3,000 watts) / Surge: 50A (6,000 watts)

Table 5 .2 120V AC output power parameters

OUTLET PORTS

1

12VDC

2VDC MAX 30
PD60W 5V 2.4A QC 3.0 PD60W

A

MAX 30A
12VDC 2A

AC OUTPUT MAX 15A

AC OUTPUT MAX 25A

ALTERNATE AC OUTPUT MAX 25A

Fig. 5 .5 120V AC output ports

11
Hysolis Apollo 5K Manual – Primary V20240108P.indd 11

1/8/24 9:58AM

5 .3 .3 Single Unit: 120V DC Input
Acceptable Voltage Range 12VDC or 24VDC Maximum Current 10A
Table 5 .3 120V DC input power parameters
INPUT PORT

I n v e r te AC Inp

S witch S witch

MAX · 35A AC INPUT

r R eset

ut R es et

COM1

COM2

AC OUTPUT

COMM.PORT

12V/24V MAX · 10A DC INPUT

BATTERY 1 51.2VDC

CAUTION!
SWITCH BATTERIES OFF BEFORE CONNECTING OR DISCONNECTING BATTERY CABLES.
CAUTION!
ONLY CONNECT HYSOLIS 5K BATTERIES. DO NOT USE 3RD-PARTY BATTERIES. CONNECTING THE WRONG BATTERY MAY DAMAGE THE UNIT AND/OR HARM THE USER.

BATTERY 2 51.2VDC

Battery Switch
NOTICE! DISCONNECT ALL INPUT AND OUTPUT CABLES BEFORE SWITCHING ON OR OFF. BATTERY MAY ALWAYS BE LEFT ON EXCEPT FOR SHIPPING OR STORAGE.
RESET

SOLAR INPUT 120V~450V
MAX.4400W(18A)
DANGER! VOLTAGE MAY BE PRESENT ON PV INPUT WHEN INVERTER IS OPERATING..

RUN ALM

CHARGE

Fig. 5 .6 Single unit – 120V DC input port and cable

12
Hysolis Apollo 5K Manual – Primary V20240108P.indd 12

1/8/24 9:58AM

5 .3 .4 Single Unit: 120V DC Output

Wireless Charger Max 20W 12VDC Output Anderson Plug Max 30A 12VDC Output Cigarette Lighter Socket Max 10A 5VDC Output USB / TYPE C Charger Max 100W
12VDC Output 5210 Sockets Max 2A Table 5 .4 120V DC output power parameters

OUTLET PORTS

Refrigerator 1x: 12VDC Output Anderson Plug (MAX 30A)
Fan 1X: 12VDC Output Cigarette Lighter Socket (MAX 10A)

1

12VDC

2VDC MAX 30
PD60W 5V 2.4A QC 3.0 PD60W

A

MAX 30A
12VDC 2A

Phone 1x: 5VDC Output USB / TYPE
C Charger
Light Bulb 1X: 12VDC Output 5210 Sockets (MAX 2A)

AC OUTPUT MAX 15A

AC OUTPUT MAX 25A

ALTERNATE AC OUTPUT MAX 25A

Fig. 5 .7

Fig. 5 .7 Single unit – 120V DC output ports

13
Hysolis Apollo 5K Manual – Primary V20240108P.indd 13

1/8/24 9:58AM

5 .3 .5 Single Unit: PV (solar) Input

N panels in series (Note: always configure your array within the MPPT specifications (Table 5.5)

Solar MPPT Voltage Range 60VDC~500VDC

Maximum Solar Charging Power 4,400 watts

Maximum Solar Input Current 18A

Maximum Solar Input Power 5,000 watts*

Maximum MPPT Charge Current DC 80A

  • When Inverter is Active, some Solar Input Power may be used for Inverter Power
    Table 5 .5 PV input power parameters

Panel 1

Panel 2

Panel 3

Panel N

In v e r te A C Inp

S witch S w itc h

MAX · 35A AC INPUT

r R eset

ut R es et

COM1

COM2

AC OUTPUT

COMM.PORT

12V/24V MAX · 10A DC INPUT

BATTERY 1 51.2VDC

CAUTION!
SWITCH BATTERIES OFF BEFORE CONNECTING OR DISCONNECTING BATTERY CABLES.
CAUTION!
ONLY CONNECT HYSOLIS 5K BATTERIES. DO NOT USE 3RD-PARTY BATTERIES. CONNECTING THE WRONG BATTERY MAY DAMAGE THE UNIT AND/OR HARM THE USER.

BATTERY 2 51.2VDC

Battery Switch
NOTICE! DISCONNECT ALL INPUT AND OUTPUT CABLES BEFORE SWITCHING ON OR OFF. BATTERY MAY ALWAYS BE LEFT ON EXCEPT FOR SHIPPING OR STORAGE.
RESET

SOLAR INPUT 120V~450V
MAX.4000W(18A)
DANGER! VOLTAGE MAY BE PRESENT ON PV INPUT WHEN INVERTER IS OPERATING..

RUN ALM

CHARGE

Fig. 5 .8 Single unit – PV input port and cable (N panels) 14

Hysolis Apollo 5K Manual – Primary V20240108P.indd 14

1/8/24 9:58AM

Important! The Working Voltage must be within the Apollo’s range of 60­500V.
The following tables provide reference calculations to demonstrate the behavior of wattage, voltage, and amperage with solar panels in a series array. The calculations are based on the voltage and wattage of the solar panel specifications of; 410W/37.1V (Table 5 .6) and 200W/20.4V (Table 5 .7).
The number of panels (i.e. 4­10, 7­20) multiply to produce the total voltage and power of the solar array. The total Open Circuit Voltage (Voc) and Short Circuit Current (Isc) must be within the unit’s operating range between 60-500V and <=18A, respectively.

Solar Panel Specifications (For reference)

PV Array

Open Circuit Voltage

Working Working Voltage Current

Total Power

· Pmax: 410W · Vmp: 30.6V · Imp: 13.4A · Voc: 37.1V · Isc: 13.9A

3 panels in series x 1 string
4 panels in series x 1 string
5 panels in series x 1 string
6 panels in series x 1 string
7 panels in series x 1 string
8 panels in series x 1 string
9 panels in series x 1 string
10 panels in series x 1 string
11 panels in series x 1 string
12 panels in series x 1 string
13 panels in series x 1 string

111.0V 149.0V 186.0V 223.0V 260.0V 297.0V 334.0V 371.0V 409.0V 446.0V 483.0V

92.0V 122.0V 153.0V 184.0V 214.0V 245.0V 275.0V 306.0V 337.0V 367.0V 398.0V

13.4A 13.4A 13.4A 13.4A 13.4A 13.4A 13.4A 13.4A 13.4A 13.4A 13.4A

1230W 1630W 2050W 2470W 2870W 3280W 3690W 4100W 4520W 4920W 5330W

Table 5 .6 Example calculations based on 410W/37.1V
Note: The working current stays the same with each series array. Although the maximum total charging power is 4400W, you may safely “over-panel” the array up to 500V or approximately 5300W with 410W panels.

15

Hysolis Apollo 5K Manual – Primary V20240108P.indd 15

1/8/24 9:58AM

Solar Panel Specifications (For reference)

PV Array

Open Circuit Voltage

Working Working Voltage Current

Total Power

4 panels in series x 1 string

5 panels in series x 1 string

6 panels in series x 1 string

7 panels in series x 1 string

8 panels in series x 1 string

9 panels in series x 1 string

· Pmax: 200W · Vmp: 20.4V · Imp: 9.8A · Voc: 24.3V · Isc: 10.2A

10panels in series x 1 string
11 panels in series x 1 string
12 panels in series x 1 string
13 panels in series x 1 string

14 panels in series x 1 string

15 panels in series x 1 string

16 panels in series x 1 string

17 panels in series x 1 string

18 panels in series x 1 string

19 panels in series x 1 string

20 panels in series x 1 string

97.0V 122.0V 146.0V 170.0V 194.0V 219.0V 243.0V 267.0V 292.0V 316.0V 340.0V 365.0V 389.0V 413.0V 437.0V 462.0V 486.0V

82.0V 102.0V 122.0V 143.0V 163.0V 184.0V 204.0V 224.0V 245.0V 265.0V 286.0V 306.0V 326.0V 347.0V 367.0V 388.0V 408.0V

13.4A 13.4A 13.4A 13.4A 13.4A 13.4A 13.4A 13.4A 13.4A 13.4A 13.4A 13.4A 13.4A 13.4A 13.4A 13.4A 13.4A

800W 1000W 1200W 1400W 1600W 1800W 2000W 2200W 2400W 2600W 2800W 3000W 3190W 3400W 3600W 3800W 4000W

Table 5 .7 Example calculations based on 200W/20.4V 16

Hysolis Apollo 5K Manual – Primary V20240108P.indd 16

1/8/24 9:58AM

6.0 Operation

The following section describes the power options and touchscreen operation of the unit.
6.1 Power-on Options
To enable battery power, press the Battery Switch on the back of unit. Note: Make sure all cables are disconnected first.

6 .1 .1 Battery Power

Note: Switch off the battery for long periods of inactivity, for shipping, or for

storage. Important! Make sure all cables are disconnected before switching

the unit off.

2

3a 3b

I n v e r te AC Inp
A

S witch
S witch 1

12VDC

2VDC MAX 30
PD60W 5V 2.4A QC 3.0 PD60W

MAX 30A
12VDC 2A

Home Settings
Data Warnings

11/15/XXXX 15:15

PV 120VAC 12VDC

2560 W

2560 W

2500 W 120 W

330 W

100%

INV. RESTART

AC Load AC ON
DC Load DC OFF

AC OUTPUT MAX 15A

AC OUTPUT MAX 25A

ALTERNATE AC OUTPUT MAX 25A

1

MAX · 35A AC INPUT

r R eset

ut R es et

COM1

COM2

AC OUTPUT

COMM.PORT

12V/24V MAX · 10A DC INPUT

BATTERY 1 51.2VDC

CAUTION!
SWITCH BATTERIES OFF BEFORE CONNECTING OR DISCONNECTING BATTERY CABLES.
CAUTION!
ONLY CONNECT HYSOLIS 5K BATTERIES. DO NOT USE 3RD-PARTY BATTERIES. CONNECTING THE WRONG BATTERY MAY DAMAGE THE UNIT AND/OR HARM THE USER.

BATTERY 2 51.2VDC

Battery Switch
NOTICE! DISCONNECT ALL INPUT AND OUTPUT CABLES BEFORE SWITCHING ON OR OFF. BATTERY MAY ALWAYS BE LEFT ON EXCEPT FOR SHIPPING OR STORAGE.
RESET

SOLAR INPUT 120V~450V
MAX.4400W(18A)
DANGER! VOLTAGE MAY BE PRESENT ON PV INPUT WHEN INVERTER IS OPERATING..

RUN ALM

CHARGE

11/15/XXXX 15:15

Home Settings Information
Alerts

PV 120VAC 12VDC

2560 W

2560 W ECO

2500 W 120 W

330 W

100%

AC Load AC ON
4
DC Load DC OFF

Fig. 6 .1 Battery power setup

1 . With all cables disconnected, press the Battery Switch to connect the battery. Touchscreen will light up.
2 . Wait until the Bluetooth signal is ready. Note: Bluetooth icon is highlighted blue.
3a . Press AC Output once to turn on the Inverter. Note: The AC switch will toggle to ON then OFF.
3b . Press AC Output again to turn on the Inverter. Note: AC Output is now enabled.
4 . Turn AC Output or DC Output on/off as needed.
17

Hysolis Apollo 5K Manual – Primary V20240108P.indd 17

1/8/24 9:58AM

6 .1 .2 AC Power

12VDC

2VDC MAX 30
PD60W 5V 2.4A QC 3.0 PD60W

MAX 30A
12VDC 2A

Home Settings
Data Warnings

11/15/XXXX 15:15

PV 120VAC 12VDC

2560 W

2560 W

2500 W 120 W

330 W

100%

INV. RESTART

AC Load AC ON
DC Load DC OFF

AC OUTPUT MAX 15A

AC OUTPUT MAX 25A

ALTERNATE AC OUTPUT MAX 25A

I n v e r te AC Inp
A

S witch
S witch 1

3

1

MAX · 35A AC INPUT

r R eset

ut R es et

COM1

COM2

AC OUTPUT

COMM.PORT

12V/24V MAX · 10A DC INPUT

BATTERY 1 51.2VDC

CAUTION!
SWITCH BATTERIES OFF BEFORE CONNECTING OR DISCONNECTING BATTERY CABLES.
CAUTION!
ONLY CONNECT HYSOLIS 5K BATTERIES. DO NOT USE 3RD-PARTY BATTERIES. CONNECTING THE WRONG BATTERY MAY DAMAGE THE UNIT AND/OR HARM THE USER.

BATTERY 2 51.2VDC

Battery Switch
NOTICE! DISCONNECT ALL INPUT AND OUTPUT CABLES BEFORE SWITCHING ON OR OFF. BATTERY MAY ALWAYS BE LEFT ON EXCEPT FOR SHIPPING OR STORAGE.
RESET

SOLAR INPUT 120V~450V
MAX.4400W(18A)
DANGER! VOLTAGE MAY BE PRESENT ON PV INPUT WHEN INVERTER IS OPERATING..

RUN ALM

CHARGE

Home Settings Information
Alerts

2
11/15/XXXX 15:15

PV 120VAC 12VDC

2560 W
2500 W 120 W

2560 W ECO
330 W

AC Load AC ON
5

100%

DC Load DC OFF

Fig. 6 .2 AC power setup

4

1 . With all cables disconnected, press the Battery Switch to connect the battery. Touchscreen will light up.
2 . Wait until the Bluetooth signal is ready. Note: Bluetooth icon is highlighted blue.
3 . Plug the AC charging cable into the AC Input port.
4 . Plug the AC charging cable to the 110V/120V power source. Note: The inverter will be started automatically.
5 . Turn AC Output or DC Output on/off as needed.

18
Hysolis Apollo 5K Manual – Primary V20240108P.indd 18

1/8/24 9:58AM

I n v e r te AC Inp
A

S witch
S witch 1

6 .1 .3 PV (solar) Power

12VDC

2VDC MAX 30
PD60W 5V 2.4A QC 3.0 PD60W

MAX 30A
12VDC 2A

Home Settings
Data Warnings

11/15/XXXX 15:15

PV 120VAC 12VDC

2560 W

2560 W

2500 W 120 W

330 W

100%

INV. RESTART

AC Load AC ON
DC Load DC OFF

AC OUTPUT MAX 15A

AC OUTPUT MAX 25A

ALTERNATE AC OUTPUT MAX 25A

MAX · 35A AC INPUT

1
12V/24V MAX · 10A DC INPUT

2

11/15/XXXX 15:15

Home Settings Information
Alerts

PV 120VAC 12VDC

2560 W
2500 W 120 W

2560 W ECO
330 W

AC Load AC ON
4

100%

DC Load DC OFF

Fig. 6 .3 PV (solar )power setup

3

r R eset

ut R es et

COM1

COM2

AC OUTPUT

COMM.PORT

BATTERY 1 51.2VDC

CAUTION!
SWITCH BATTERIES OFF BEFORE CONNECTING OR DISCONNECTING BATTERY CABLES.
CAUTION!
ONLY CONNECT HYSOLIS 5K BATTERIES. DO NOT USE 3RD-PARTY BATTERIES. CONNECTING THE WRONG BATTERY MAY DAMAGE THE UNIT AND/OR HARM THE USER.

BATTERY 2 51.2VDC

Battery Switch
NOTICE! DISCONNECT ALL INPUT AND OUTPUT CABLES BEFORE SWITCHING ON OR OFF. BATTERY MAY ALWAYS BE LEFT ON EXCEPT FOR SHIPPING OR STORAGE.
RESET

SOLAR INPUT 120V~450V
MAX.4400W(18A)
DANGER! VOLTAGE MAY BE PRESENT ON PV INPUT WHEN INVERTER IS OPERATING..

RUN ALM

CHARGE

3

1 . With all cables disconnected, press the Battery Switch to connect the battery. Touchscreen will light up.
2 . Wait until the Bluetooth signal is ready. Note: Bluetooth icon is highlighted blue.
Important! Ensure the Apollo 5K system is grounded when connecting a full- sized solar array.
Grounding can be done via the ground port on the back of the unit using the included ground rod and cable or by simply connecting the unit’s AC Input to a wall outlet in the home.
3 . Plug into solar power (Voc. Range 60V DC ~ 500V DC, Max. Charging Power 4,400W, Max. Input 5,000W/18A) using the included Solar Input Breaker.
Connect all cables when Breaker is in the OFF position. After cables are connected, flip Breaker ON. Note: The inverter will be started automatically.
4 . Turn AC Output or DC Output on/off as needed.
19

Hysolis Apollo 5K Manual – Primary V20240108P.indd 19

1/8/24 9:58AM

I n v e r te AC Inp
A

S witch
S witch 1

6 .1 .4 Turn the Power OFF

12VDC

2VDC MAX 30
PD60W 5V 2.4A QC 3.0 PD60W

MAX 30A
12VDC 2A

Home Settings
Data Warnings

11/15/XXXX 15:15

PV 120VAC 12VDC

2560 W

2560 W

2500 W 120 W

330 W

100%

INV. RESTART

AC Load AC ON
DC Load DC OFF

AC OUTPUT MAX 15A

AC OUTPUT MAX 25A

ALTERNATE AC OUTPUT MAX 25A

Home Settings
Data

Warnings

MAX · 35A AC INPUT

r R eset

ut R es et

COM1

COM2

AC OUTPUT

COMM.PORT

12V/24V MAX · 10A DC INPUT

BATTERY 1 51.2VDC

CAUTION!
SWITCH BATTERIES OFF BEFORE CONNECTING OR DISCONNECTING BATTERY CABLES.
CAUTION!
ONLY CONNECT HYSOLIS 5K BATTERIES. DO NOT USE 3RD-PARTY BATTERIES. CONNECTING THE WRONG BATTERY MAY DAMAGE THE UNIT AND/OR HARM THE USER.

BATTERY 2 51.2VDC

Battery Switch
NOTICE! DISCONNECT ALL INPUT AND OUTPUT CABLES BEFORE SWITCHING ON OR OFF. BATTERY MAY ALWAYS BE LEFT ON EXCEPT FOR SHIPPING OR STORAGE.
RESET

SOLAR INPUT 120V~450V
MAX.4400W(18A)
DANGER! VOLTAGE MAY BE PRESENT ON PV INPUT WHEN INVERTER IS OPERATING..

RUN ALM

CHARGE

1 2 3

11/15/XXXX 15:15

PV 120VAC 12VDC

2560 W
2500 W 120 W

2560 W ECO

AC Load AC OFF

4 330 W

100%

DC Load DC OFF

Fig. 6 .4 Turn power OFF

1 . Disconnect DC Input.
2 . Disconnect AC Input.
3 . Disconnect Solar Input.
4 . On the touchscreen, switch the AC Output and DC Output to the OFF position.
Note: You do not need to turn the Battery Switch OFF. You may leave the Battery Switch ON.
Important! If you wish to switch the battery off for long periods of inactivity, storage, or transport, make sure all cables are disconnected before pressing the Battery Switch off.
20

Hysolis Apollo 5K Manual – Primary V20240108P.indd 20

1/8/24 9:58AM

6.2 Touchscreens
The touchscreens provide information or settings for operation. The Home, Data, and Warnings touchscreens provide information on the operation of the unit. The Settings touchscreens are used to customize the unit’s settings (Fig. 6 .5). The following sections will explain each touchscreen. Note: See Section 8 for Error Codes.

a
Home
b
Settings
c
Information
d
Alerts

11/15/XXXX 15:15

PV 120VAC 12VDC

2560 W

2560 W ECO

2500 W 120 W

330 W

100%

AC Load AC ON
DC Load DC OFF

Fig. 6 .5 Homepage UI screen

a . Home Touchscreens: Select to see real-time information on the AC input, AC output, DC input, DC output, PV (solar) input, and the battery status.
b . Settings Touchscreens: Select to set the settings for the Working Mode, Energy Saver, Unattended Mode, Parallel Mode, Language, Display Settings, and WiFi.
c . Information Touchscreens: Select to see information about the product, the power generated by the different sources, and view the alert history.
d . Alerts Touchscreen: Select to see the current error code and time.

21
Hysolis Apollo 5K Manual – Primary V20240108P.indd 21

1/8/24 9:58AM

6 .2 .1 Home Information Touchscreen
When selecting the Home button on the Homepage UI touchscreen you can find real-time information on the AC input, AC output, DC input, DC output, PV (solar) input, and the battery status. Select the appropriate button to see the desired information. (Fig. 6 .6).

PV Input
Power Voltage Current
AC Input
Power Voltage Current Frequency
DC Charge
Power Voltage Current

Back

2870 W

142.5 V

a

20.5 A

Home
Back

2670 W 120.5 V 22.5 A 49.99 Hz

b

Settings

Information

Back

120 W

13.8 V

c

8.6 A

Alerts

11/15/XXXX 15:15

PV 120VAC 12VDC

2560 W

2560 W ECO

2500 W 120 W

330 W

100%

AC Load AC ON
DC Load DC OFF

Fig. 6 .6 Information screens
a . PV (solar) Input Information: Selecting the PV (solar) button on the Homepage UI touchscreen will show the real-time running status of Power, Voltage, and Current.
b . AC Input Information: Selecting the 120VAC button on the Homepage UI touchscreen will show the real-time running status of Power, Voltage, Current, and Frequency.
c . DC Input Information: Selecting the 12VDC button on the Homepage UI touchscreen will show the real-time running status of Power, Voltage, and Current. 22

Hysolis Apollo 5K Manual – Primary V20240108P.indd 22

1/8/24 9:58AM

Homepage UI screen (continued)

Home Settings Information
Alerts

11/15/XXXX 15:15

PV 120VAC 12VDC

2560 W

2560 W ECO

2500 W 120 W

330 W

100%

AC Load AC ON
DC Load DC OFF

AC Output

Loads

d

Voltage

Current

Frequency

Back
85 % 120.5 V 22.5 A 49.99 Hz

Battery

Energy Available

e

Voltage

Current

Temper atur e

Back
99.5 Ah 54.8 V 41.7 A
45.9 °c

DC Output

Power

f

Voltage

Current

Back
330 W 12.8 V 25.7 A

Fig. 6 .7 Information screens
d . AC Output Information: Selecting the AC Load button on the Homepage UI touchscreen will show the real-time running status of Loads, Voltage, Current, and Frequency.
e . Battery Information: Selecting the Battery button on the Homepage UI touchscreen will show the real-time running status of the Energy Available, Voltage, Current, and Temperature.
f . DC Output Information: Selecting the DC Load button on the Homepage UI touchscreen will show the real-time running status of Power, Voltage, and Current.