Hysolis APL2401 Apollo 5K Portable Solar Power Station User Manual
- May 15, 2024
- HYSOLIS
Table of Contents
APL2401 Apollo 5K Portable Solar Power Station
“`html
- dfgd Product Usage Instructions
1. Initial Inspection
Inspect the product for any damage during transit. Do not power
the product ON until inspection is complete.
Check for the following items in the box:
- Wireless Charger
- Cables (shipped separately in the accessories box)
2. Safety Guidelines
All personnel involved in the installation, use, or maintenance
of this product must read and understand the provided safety
information in the manual.
WARNING: Use only a dry chemical powder fire
extinguisher if the product is exposed to flame or fire. Using a
wet chemical fire extinguisher can conduct electricity and cause an
electric shock.
3. Product Features
Top Panel
- Wireless Charger: For charging compatible electronic
devices.
Front Panel
- 12VDC Output Sockets (MAX 2A)
- 12VDC Output Anderson Plug (MAX 30A)
- 12VDC Output Cigarette Lighter Socket (MAX 10A)
- 5VDC Output USB/TYPE C Charger
- 120V AC Output NEMA 5-20R outlets (Max 20A)
- 120V AC Output NEMA TT-30R Outlet (Max 25A)
- 120V Alternate AC Output Outlet (Max 25A)
- Touchscreen
- Indicator Light
- Air Vent (removable for cleaning)
Back Panel
-
120V AC Input Port LP-28 (Max 30A)
-
Inverter Reset Switch
-
AC Output parallel communication port (For AC output parallel
setup) -
Expansion Battery Port 1
-
Expansion Battery Port 2
-
AC Input Reset Switch
-
12/24VDC Input Port (Max. 10A)
-
Power Switch (for Battery BMS)
-
Solar Input Port (Voc. Range 120V DC ~ 500V DC, Max. Charging
Power 4,400W, Max. Total Input for Charging+Inverter
5,000W/18A)
Frequently Asked Questions (FAQ)
Q: What should I do if I encounter issues with charging my
devices using the wireless charger?
A: Ensure that the compatible electronic device is properly
aligned on the wireless charger for efficient charging. If issues
persist, contact customer service for further assistance.
Q: Can I connect multiple devices to the AC outputs
simultaneously?
A: Yes, you can connect multiple devices to the AC outputs as
long as the total combined load does not exceed the specified
maximum current ratings for each outlet.
“`
User Manual
Portable Solar Power Station
Apollo 5K
Hysolis Apollo 5K Manual – Primary V20240108P.indd 1
1/8/24 9:58AM
Contents
1.0 Introduction . . . . . . . . . . . . . . . . . . . . . . . . . 1 2.0
Safety . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2 3.0
Initial Inspection . . . . . . . . . . . . . . . . . . . . .3 4.0 Product
Features . . . . . . . . . . . . . . . . . . . 4
4 .1 Top Panel . . . . . . . . . . . . . . . . . . . . . . 4 4 .2 Front Panel
. . . . . . . . . . . . . . . . . . . . 4 4 .3 Back Panel. . . . . . . . . . .
. . . . . . . . . . 5 4 .4 Homepage UI Touchscreen . . . . . 6 4 .5 Homepage
UI Icons. . . . . . . . . . . . . 7 5.0 Installation . . . . . . . . . . . . .
. . . . . . . . . . . . 8 5 .1 Overview . . . . . . . . . . . . . . . . . . .
. . . 9 5 .2 General Installation Guidelines 9 5 .3 Single Unit Options. . . .
. . . . . . . . . 9 6.0 Operation . . . . . . . . . . . . . . . . . . . . . .
. . . . . 17 6 .1 Power-on Options. . . . . . . . . . . . . .17 6 .2
Touchscreens . . . . . . . . . . . . . . . . . 21 7.0 Product Care . . . . . .
. . . . . . . . . . . . . . . . . 37 8.0 Troubleshooting . . . . . . . . . . .
. . . . . . . . 37 9.0 Technical Specifications . . . . . . . . . . . . .41
10.0 Declarations . . . . . . . . . . . . . . . . . . . . . . . 42 11.0 FCC
Compliance Statement . . . . . . . . . 43 12.0 IC Notice . . . . . . . . . . .
. . . . . . . . . . . . . . . . 44
Hysolis Apollo 5K Manual – Primary V20240108P.indd 2
1/8/24 9:58AM
1.0 Introduction
1
12VDC
2VDC MAX 30
PD60W 5V 2.4A QC 3.0 PD60W
A
MAX 30A
12VDC 2A
AC OUTPUT MAX 15A
AC OUTPUT MAX 25A
ALTERNATE AC OUTPUT MAX 25A
Thank you very much for purchasing the
Hysolis Apollo 5K unit! We designed this product to help grant you energy
independence. We have the utmost confidence in this product’s performance and
quality. Please feel free to contact us at Hysolis .com if you have any
questions. Enjoy using your Hysolis Apollo 5K, and may it positively affect
your future endeavors!
The product has the following features: · Dual-CPU Intelligent Control
Technology manages energy input/output · High-frequency pure sine wave output
is clean and reliable for any load · Wide input voltage range and consistent
voltage output · Three programmable working modes prioritize different energy
needs:
· UPS mode: Utility Power first, a.k.a. “Pass-through AC Power” · AC Fast
Charge (AC F .C .) mode: 120V AC power Fast Charge,
600W-3,000W (5A – 25A) programmable · Battery First mode: The solar charges
the battery and grid. AC Power is
only used if battery is almost empty. · Intelligent MPPT solar controller
features over-charge & over-discharge
protection, current limiting charging, and multiple other safety protections ·
Battery over-voltage and low-voltage protection, overload protection, short
circuit protection, over-temperature and under-temperature protection. · A
4.3″ touchscreen shows real-time running statuses at-a-glance · Remote
monitoring and control · Compact and modular unit design for portability ·
Smart Fan Control keeps the unit cool, safe, and reliable · Multiple output
power supply (120VAC/3000W, 12VDC/600W, 5VDC/120W) · Unattended mode: If
battery runs out, inverter auto-starts when solar power
is available.
1
Hysolis Apollo 5K Manual – Primary V20240108P.indd 1
1/8/24 9:58AM
2.0 Safety
All personnel engaged with installation, use, or maintenance of this product
must read, and understand the information in this manual. Please contact
customer service if there are any questions before operating this product.
WARNING
· Inserting foreign objects into any of the product’s port or ventilation
holes may cause an electrical shock and result in death or serious injury.
Never insert foreign objects into any of the product’s port or ventilation
holes.
· Improper connections between the unit and the power source may result in
exposure to electricity and could result in death or serious injury. A
licensed electrician is required to install the Apollo 5K as spacing
installation involves connecting the wires from your home circuit breaker box
to the Apollo 5K Wiring Box (optional purchase).
· Placement of the product near any heat sources may result in an explosion or
toxic fumes and could result in death or serious injury. Never place and
operate the product in an environment with flammable, explosive gas, or smoke.
· Operation of the product in wet conditions may conduct electricity and
expose people and animals to electric shock resulting in minor injury or
death. Always turn the power to the unit OFF if is operating in wet
conditions. Let the unit dry completely and ensure the unit is in a safe
environment before turning the power to the unit on.
· This product utilizes high voltage solar array to charge. Exercise extreme
caution when handling high-voltage PV (solar) wires. Do not use if wires are
damaged. Use included Solar Input Breaker to connect to Apollo.
· Voltage may be present on PV (solar) Input when inverter is in operation.
CAUTION
Only use a dry chemical powder fire extinguishing agent if the product is
exposed to flame or fire. Using a wet chemical fire extinguisher can conduct
electricity and cause an electric shock and may result in minor or moderate
injury as well as damage the product.
2
Hysolis Apollo 5K Manual – Primary V20240108P.indd 2
1/8/24 9:58AM
NOTICE
· Ensure proper ventilation while in use and do not obstruct fan openings.
Inadequate ventilation may cause permanent damage to the equipment.
· Vibrations and impacts during product operation may damage the unit and lead
to poor connectivity to the hardware inside. Do not move the product during
operation.
· Stacking anything on top of the power station either in storage or while in
use may cause damage the product. Do not stack anything on the product.
· Replacement of the internal battery or any other components of product by
anyone other than authorized personnel may result in damage to the product.
Always have authorized personnel perform hardware maintenance.
3.0 Initial Inspection
NOTICE
Inspect the product for damage during transit. Do not power the product ON.
Check the following items are in the box (Note: Cables are shipped separately in the accessories box):
· AC charging cable
· Ground cable and spike
· DC charging cable · Solar Input Breaker
Hysolis Apollo 5K Manual – Primary V20240108P.indd 3
· Wall-Outlet Adapter for AC charging cable
· User Manual · Apollo 5K Unit Report any damage to the product to the dealer
and carrier. Contact Hysolis customer service regarding any missing items:
Phone: +1 (760) 410-5917 Email: support@hysolis.com 3
1/8/24 9:58AM
4.0 Product Features
4.1 Top Panel
1 . Wireless Charger Note: The wireless charger can be used to charge
compatible electronic devices.
4.2 Front Panel
2 . 12VDC Output 5210 Sockets (MAX 2A)
3 . 12VDC Output Anderson Plug (MAX 30A)
4 . 12VDC Output Cigarette 4
Lighter Socket (MAX 10A)
5 . 5VDC Output USB /TYPE 5
C Charger
6 . 120V AC Output NEMA
5-20R outlets
6
(Max 20A)
7 . 120V AC Output NEMA TT-30R Outlet (Max 25A)
8 . 120V Alternate AC Output Outlet (Max 25A)
9 . Touchscreen
10 . Indicator Light
11 . Air Vent (removable for cleaning)
Hysolis Apollo 5K Manual – Primary V20240108P.indd 4
1
1
Fig. 4 .1 · Unit top view
32
12VDC
2VDC MAX 30
PD60W 5V 2.4A QC 3.0 PD60W
A
MAX 30A
12VDC 2A
AC OUTPUT MAX 15A
AC OUTPUT MAX 25A
ALTERNATE AC OUTPUT MAX 25A
10 9 7 8
11
Fig. 4 .2 · Unit front panel 4
1/8/24 9:58AM
4.3 Back Panel
12 . 120V AC Input Port LP-28 (MAX 30A)
13 . Inverter Reset Switch
14. AC Output parallel
communication port 12
(For AC output parallel
set up)
13
15 . Expansion Battery
Port 1
14
16 . Expansion Battery
Port 2
17 . AC Input Reset Switch 15
18 . 12/24VDC Input Port (Max. 10A)
19 . Power Switch
16
(for Battery BMS)
20 . Solar Input Port (Voc. Range 120V DC ~ 500V DC, Max. Charging Power 4,400W, Max. Total Input for Charging+Inverter 5,000W/18A)
21 . BMS Working Status Indicator
22 . Ground Port
23 . BMS Reset Button
I n v e r te AC Inp
17
S witch S witch
MAX · 35A AC INPUT
r R eset
ut R es et
COM1
COM2
AC OUTPUT
COMM.PORT
12V/24V MAX · 10A DC INPUT
BATTERY 1 51.2VDC
CAUTION!
SWITCH BATTERIES OFF BEFORE CONNECTING OR DISCONNECTING BATTERY CABLES.
CAUTION!
ONLY CONNECT HYSOLIS 5K BATTERIES. DO NOT USE 3RD-PARTY BATTERIES. CONNECTING
THE WRONG BATTERY MAY DAMAGE THE UNIT AND/OR HARM THE USER.
BATTERY 2 51.2VDC
Battery Switch
NOTICE! DISCONNECT ALL INPUT AND OUTPUT CABLES BEFORE SWITCHING ON OR OFF.
BATTERY MAY ALWAYS BE LEFT ON EXCEPT FOR SHIPPING OR STORAGE.
RESET
SOLAR INPUT 120V~450V
MAX.4400W(18A)
DANGER! VOLTAGE MAY BE PRESENT ON PV INPUT WHEN INVERTER IS OPERATING..
RUN ALM
CHARGE
18
19 20
21 22
23
Fig. 4 .3 · Unit back panel
5
Hysolis Apollo 5K Manual – Primary V20240108P.indd 5
1/8/24 9:58AM
4.4 Homepage UI Touchscreen
efg
h
a
Home
b
Settings
c
Information
d
Alerts
11/15/XXXX 15:15
PV 120VAC 12VDC
2560 W
2560 W
2500 W 120 W
330 W
100%
AC Load AC ON
DC Load DC OFF
i j
k l
m
Fig. 4 .4 · Homepage UI touchscreen features
a . Homepage Button: Press to return to the Homepage UI touchscreen b . Setting Screens Button: Press to access the Settings screens c . Information Screens Button: Press to access the Information screens d . Alert Screen Button: Press to access the current Alert screen e . PV (solar) Button: Press to access the PV Input information screen f . AC Button: Press to access the AC Input information screen g . Battery Button: Press to access the Battery information screen h . Date & Time: Displays current Date and Time i . AC Load Button: Press to access the AC Output information screen j . AC Output On/OFF Switch: Toogle to turn AC Output ON or OFF k . DC Load Button: Press to access the DC Output information screen l . DC Output ON/OFF Switch: Toggle to turn DC Output ON or OFF m . DC Button: Press to access the DC Charge information screen
6
Hysolis Apollo 5K Manual – Primary V20240108P.indd 6
1/8/24 9:58AM
4.5 Homescreen UI Icons
b cd
h
i
a
g
11/15/XXXX 15:15
Home Settings
ef
2560 W
2560 W
ECO
PV
AC Load
2500 W
AC ON
j
Data
120VAC
120 W
330 W
k
100%
12VDC
DC Load DC OFF
Warnings
Fig. 4 .5 · Homepage UI touchscreen icons a . AC/DC Status: The unit is charging.
b . Battery Status Indicator: Battery charge level.
c . Bluetooth Indicator (connected): The unit is connected to Bluetooth.
d . Bluetooth Indicator (not connected): The unit is not connected to
Bluetooth.
e . WiFi Status (connected): The unit is connected to a WiFi network. f . WiFi
Status (ready to connect): The WiFi settings have been reset
and the device is ready to connect to a WiFi network. g . WiFi Status
(connecting): The unit is connecting to Bluetooth.
ECO h . Energy Saver Mode Status: Energy saver mode is on.
i . Inverter Status (disconnected): The inverter is disconnected, click to
power on the inverter.
j . Unattended Mode Status: Unattended mode is on.
k . Inverter Status (disconnected): Inverter may not be used when using AC
F.C. mode greater than the default value.
7
Hysolis Apollo 5K Manual – Primary V20240108P.indd 7
1/8/24 9:58AM
5.0 Installation
Important! A licensed electrician is required to install the Apollo 5K in any
hardwired fashion. An Apollo 5K Wiring Box (Optional Purchase) may be used in
the installation. For all configurations, please consider the rated amperages
of power sources, total loads, wires, and the Apollo 5K. Do not exceed limits.
The Apollo 5K factory default setting is “floating neutral” (i.e. the neutral
and ground are unbonded.
The unit should be configured with floating neutral when connecting the load
side of the Apollo to a separate ground (e.g. directly supplying power to a
home breaker panel).
The unit may be configured with a neutral-ground bond, a.k.a. “bonded
neutral”, which may be preferred for some off-grid applications. To bond the
neutral to the ground, please follow instructions according to the label on
the side panel of the Apollo as depicted in Fig. 5.1 and Fig. 5.2 below.
The Apollo ground port may be connected to a grounding rod, building rod, etc.
by a qualified electrician. Ensure the Apollo neutral-ground is appropriately
bonded or unbonded.
Fig. 5 .1 Neutral-Ground Separated / Floating Neutral (Factory Default): The
Neutral wires to the plastic pole
Fig. 5 .2 Neutral-Ground Bonded: The Neutral wires to the metal structure
8
Hysolis Apollo 5K Manual – Primary V20240108P.indd 8
Switch t Switch
1AM1CA0VIXN/1P32U50ATV
1SM2O0ALVXA~R455I00N0VP0DUWCT
MD1CA2XVIN/2P14U0VAT
Reset Rese
AC Input Inverter
COM2 COM1
AC OUTPUT COMM.PORT
MBEDODXEAOFAPMNSBNAUUAAONGTPFTSATPEWICECLOTAROITNEHRYUNDEBN!RNWABIWUENTYRCRHGTOTT.OE!HNRLDEEGYIFOUPBFRANEAICRTIGTTEK.INENTMRAHTUYLETSMYTPAEY
RESET
B5A1T.T2EVRDYC 2
B5A1T.T2EVRDYC 2
RUN ALM
CHARGE
1/8/24 9:58AM
5.1 Overview
There are two installation options. These include Single Unit setup and Multi-
unit setup. Refer to the Apollo 5K Expandability Manual for Multi-unit setup
instructions. The power sources for each option include:
· AC input (i.e. utility power or generator)
· DC input (i.e. automobile with DC output)
· PV input (i.e. solar photovoltaic panels)
· Both setups provide AC and DC output.
5.2 General Installation Guidelines
During transport, the unit may have warmed or cooled outside of its working
temperature range. Moisture may have condensed on the unit. Ensure it is dry
and within the proper temperature range before using.
· Do not use the product in a wet or dusty environment.
· Do not use anything flammable or explosive near the product.
· Do not cover or block the vents in the product.
· Maintain 4 inches (10cm) of clear space around the unit to have good heat
dissipation.
5.3 Single Unit Options
This section provides an overview of the single unit options. It shows input power options (Fig. 5 .3), possible ouput capabilties, and describes the input and output power parameters for AC, DC, and PV (solar) input and AC, DC output.
INPUT
OUTPUT
PV Utility Generator
1
12VDC
2VDC MAX 30
PD60W 5V 2.4A QC 3.0 PD60W
A
MAX 30A
12VDC 2A
AC OUTPUT MAX 15A
AC OUTPUT MAX 25A
ALTERNATE AC OUTPUT MAX 25A
Vehicle
Fig. 5 .3 Power options and output capabilities 9
Hysolis Apollo 5K Manual – Primary V20240108P.indd 9
AC Loads
DC Loads
1/8/24 9:58AM
5 .3 .1 Single Unit: 120V AC Input
Acceptable 65V~140VAC (for home appliances) Voltage Range 95V~140VAC (for computers)
Frequency 60Hz / 50Hz (auto-sensing)
Maximum Current
30A (3,600 watts)
Table 5 .1 Single unit – 120V AC input power parameters
INPUT PORT
Utility power Generator
I n v e r te AC Inp
MAX · 35A AC INPUT
r R eset
ut R es et
COM1
COM2
AC OUTPUT
COMM.PORT
S witch S witch
12V/24V MAX · 10A DC INPUT
BATTERY 1 51.2VDC
CAUTION!
SWITCH BATTERIES OFF BEFORE CONNECTING OR DISCONNECTING BATTERY CABLES.
CAUTION!
ONLY CONNECT HYSOLIS 5K BATTERIES. DO NOT USE 3RD-PARTY BATTERIES. CONNECTING
THE WRONG BATTERY MAY DAMAGE THE UNIT AND/OR HARM THE USER.
BATTERY 2 51.2VDC
Battery Switch
NOTICE! DISCONNECT ALL INPUT AND OUTPUT CABLES BEFORE SWITCHING ON OR OFF.
BATTERY MAY ALWAYS BE LEFT ON EXCEPT FOR SHIPPING OR STORAGE.
RESET
SOLAR INPUT 120V~450V
MAX.4400W(18A)
DANGER! VOLTAGE MAY BE PRESENT ON PV INPUT WHEN INVERTER IS OPERATING..
RUN ALM
CHARGE
Fig. 5 .4 Single unit – 120V AC input port and cable
10
Hysolis Apollo 5K Manual – Primary V20240108P.indd 10
1/8/24 9:58AM
5 .3 .2 Single Unit: 120V AC Output
Voltage Range
120VAC (+/-5%) 60Hz / 50Hz (auto sensing)
Wave Form Pure sine wave
Rated Current
25A (3,000 watts) / Surge: 50A (6,000 watts)
Table 5 .2 120V AC output power parameters
OUTLET PORTS
1
12VDC
2VDC MAX 30
PD60W 5V 2.4A QC 3.0 PD60W
A
MAX 30A
12VDC 2A
AC OUTPUT MAX 15A
AC OUTPUT MAX 25A
ALTERNATE AC OUTPUT MAX 25A
Fig. 5 .5 120V AC output ports
11
Hysolis Apollo 5K Manual – Primary V20240108P.indd 11
1/8/24 9:58AM
5 .3 .3 Single Unit: 120V DC Input
Acceptable Voltage Range 12VDC or 24VDC Maximum Current 10A
Table 5 .3 120V DC input power parameters
INPUT PORT
I n v e r te AC Inp
S witch S witch
MAX · 35A AC INPUT
r R eset
ut R es et
COM1
COM2
AC OUTPUT
COMM.PORT
12V/24V MAX · 10A DC INPUT
BATTERY 1 51.2VDC
CAUTION!
SWITCH BATTERIES OFF BEFORE CONNECTING OR DISCONNECTING BATTERY CABLES.
CAUTION!
ONLY CONNECT HYSOLIS 5K BATTERIES. DO NOT USE 3RD-PARTY BATTERIES. CONNECTING
THE WRONG BATTERY MAY DAMAGE THE UNIT AND/OR HARM THE USER.
BATTERY 2 51.2VDC
Battery Switch
NOTICE! DISCONNECT ALL INPUT AND OUTPUT CABLES BEFORE SWITCHING ON OR OFF.
BATTERY MAY ALWAYS BE LEFT ON EXCEPT FOR SHIPPING OR STORAGE.
RESET
SOLAR INPUT 120V~450V
MAX.4400W(18A)
DANGER! VOLTAGE MAY BE PRESENT ON PV INPUT WHEN INVERTER IS OPERATING..
RUN ALM
CHARGE
Fig. 5 .6 Single unit – 120V DC input port and cable
12
Hysolis Apollo 5K Manual – Primary V20240108P.indd 12
1/8/24 9:58AM
5 .3 .4 Single Unit: 120V DC Output
Wireless Charger Max 20W 12VDC Output Anderson Plug Max 30A 12VDC Output
Cigarette Lighter Socket Max 10A 5VDC Output USB / TYPE C Charger Max 100W
12VDC Output 5210 Sockets Max 2A Table 5 .4 120V DC output power parameters
OUTLET PORTS
Refrigerator 1x: 12VDC Output Anderson Plug (MAX 30A)
Fan 1X: 12VDC Output Cigarette Lighter Socket (MAX 10A)
1
12VDC
2VDC MAX 30
PD60W 5V 2.4A QC 3.0 PD60W
A
MAX 30A
12VDC 2A
Phone 1x: 5VDC Output USB / TYPE
C Charger
Light Bulb 1X: 12VDC Output 5210 Sockets (MAX 2A)
AC OUTPUT MAX 15A
AC OUTPUT MAX 25A
ALTERNATE AC OUTPUT MAX 25A
Fig. 5 .7
Fig. 5 .7 Single unit – 120V DC output ports
13
Hysolis Apollo 5K Manual – Primary V20240108P.indd 13
1/8/24 9:58AM
5 .3 .5 Single Unit: PV (solar) Input
N panels in series (Note: always configure your array within the MPPT specifications (Table 5.5)
Solar MPPT Voltage Range 60VDC~500VDC
Maximum Solar Charging Power 4,400 watts
Maximum Solar Input Current 18A
Maximum Solar Input Power 5,000 watts*
Maximum MPPT Charge Current DC 80A
- When Inverter is Active, some Solar Input Power may be used for Inverter Power
Table 5 .5 PV input power parameters
Panel 1
Panel 2
Panel 3
Panel N
In v e r te A C Inp
S witch S w itc h
MAX · 35A AC INPUT
r R eset
ut R es et
COM1
COM2
AC OUTPUT
COMM.PORT
12V/24V MAX · 10A DC INPUT
BATTERY 1 51.2VDC
CAUTION!
SWITCH BATTERIES OFF BEFORE CONNECTING OR DISCONNECTING BATTERY CABLES.
CAUTION!
ONLY CONNECT HYSOLIS 5K BATTERIES. DO NOT USE 3RD-PARTY BATTERIES. CONNECTING
THE WRONG BATTERY MAY DAMAGE THE UNIT AND/OR HARM THE USER.
BATTERY 2 51.2VDC
Battery Switch
NOTICE! DISCONNECT ALL INPUT AND OUTPUT CABLES BEFORE SWITCHING ON OR OFF.
BATTERY MAY ALWAYS BE LEFT ON EXCEPT FOR SHIPPING OR STORAGE.
RESET
SOLAR INPUT 120V~450V
MAX.4000W(18A)
DANGER! VOLTAGE MAY BE PRESENT ON PV INPUT WHEN INVERTER IS OPERATING..
RUN ALM
CHARGE
Fig. 5 .8 Single unit – PV input port and cable (N panels) 14
Hysolis Apollo 5K Manual – Primary V20240108P.indd 14
1/8/24 9:58AM
Important! The Working Voltage must be within the Apollo’s range of 60500V.
The following tables provide reference calculations to demonstrate the
behavior of wattage, voltage, and amperage with solar panels in a series
array. The calculations are based on the voltage and wattage of the solar
panel specifications of; 410W/37.1V (Table 5 .6) and 200W/20.4V (Table 5 .7).
The number of panels (i.e. 410, 720) multiply to produce the total voltage
and power of the solar array. The total Open Circuit Voltage (Voc) and Short
Circuit Current (Isc) must be within the unit’s operating range between
60-500V and <=18A, respectively.
Solar Panel Specifications (For reference)
PV Array
Open Circuit Voltage
Working Working Voltage Current
Total Power
· Pmax: 410W · Vmp: 30.6V · Imp: 13.4A · Voc: 37.1V · Isc: 13.9A
3 panels in series x 1 string
4 panels in series x 1 string
5 panels in series x 1 string
6 panels in series x 1 string
7 panels in series x 1 string
8 panels in series x 1 string
9 panels in series x 1 string
10 panels in series x 1 string
11 panels in series x 1 string
12 panels in series x 1 string
13 panels in series x 1 string
111.0V 149.0V 186.0V 223.0V 260.0V 297.0V 334.0V 371.0V 409.0V 446.0V 483.0V
92.0V 122.0V 153.0V 184.0V 214.0V 245.0V 275.0V 306.0V 337.0V 367.0V 398.0V
13.4A 13.4A 13.4A 13.4A 13.4A 13.4A 13.4A 13.4A 13.4A 13.4A 13.4A
1230W 1630W 2050W 2470W 2870W 3280W 3690W 4100W 4520W 4920W 5330W
Table 5 .6 Example calculations based on 410W/37.1V
Note: The working current stays the same with each series array. Although the
maximum total charging power is 4400W, you may safely “over-panel” the array
up to 500V or approximately 5300W with 410W panels.
15
Hysolis Apollo 5K Manual – Primary V20240108P.indd 15
1/8/24 9:58AM
Solar Panel Specifications (For reference)
PV Array
Open Circuit Voltage
Working Working Voltage Current
Total Power
4 panels in series x 1 string
5 panels in series x 1 string
6 panels in series x 1 string
7 panels in series x 1 string
8 panels in series x 1 string
9 panels in series x 1 string
· Pmax: 200W · Vmp: 20.4V · Imp: 9.8A · Voc: 24.3V · Isc: 10.2A
10panels in series x 1 string
11 panels in series x 1 string
12 panels in series x 1 string
13 panels in series x 1 string
14 panels in series x 1 string
15 panels in series x 1 string
16 panels in series x 1 string
17 panels in series x 1 string
18 panels in series x 1 string
19 panels in series x 1 string
20 panels in series x 1 string
97.0V 122.0V 146.0V 170.0V 194.0V 219.0V 243.0V 267.0V 292.0V 316.0V 340.0V 365.0V 389.0V 413.0V 437.0V 462.0V 486.0V
82.0V 102.0V 122.0V 143.0V 163.0V 184.0V 204.0V 224.0V 245.0V 265.0V 286.0V 306.0V 326.0V 347.0V 367.0V 388.0V 408.0V
13.4A 13.4A 13.4A 13.4A 13.4A 13.4A 13.4A 13.4A 13.4A 13.4A 13.4A 13.4A 13.4A 13.4A 13.4A 13.4A 13.4A
800W 1000W 1200W 1400W 1600W 1800W 2000W 2200W 2400W 2600W 2800W 3000W 3190W 3400W 3600W 3800W 4000W
Table 5 .7 Example calculations based on 200W/20.4V 16
Hysolis Apollo 5K Manual – Primary V20240108P.indd 16
1/8/24 9:58AM
6.0 Operation
The following section describes the power options and touchscreen operation of
the unit.
6.1 Power-on Options
To enable battery power, press the Battery Switch on the back of unit. Note:
Make sure all cables are disconnected first.
6 .1 .1 Battery Power
Note: Switch off the battery for long periods of inactivity, for shipping, or for
storage. Important! Make sure all cables are disconnected before switching
the unit off.
2
3a 3b
I n v e r te AC Inp
A
S witch
S witch 1
12VDC
2VDC MAX 30
PD60W 5V 2.4A QC 3.0 PD60W
MAX 30A
12VDC 2A
Home Settings
Data Warnings
11/15/XXXX 15:15
PV 120VAC 12VDC
2560 W
2560 W
2500 W 120 W
330 W
100%
INV. RESTART
AC Load AC ON
DC Load DC OFF
AC OUTPUT MAX 15A
AC OUTPUT MAX 25A
ALTERNATE AC OUTPUT MAX 25A
1
MAX · 35A AC INPUT
r R eset
ut R es et
COM1
COM2
AC OUTPUT
COMM.PORT
12V/24V MAX · 10A DC INPUT
BATTERY 1 51.2VDC
CAUTION!
SWITCH BATTERIES OFF BEFORE CONNECTING OR DISCONNECTING BATTERY CABLES.
CAUTION!
ONLY CONNECT HYSOLIS 5K BATTERIES. DO NOT USE 3RD-PARTY BATTERIES. CONNECTING
THE WRONG BATTERY MAY DAMAGE THE UNIT AND/OR HARM THE USER.
BATTERY 2 51.2VDC
Battery Switch
NOTICE! DISCONNECT ALL INPUT AND OUTPUT CABLES BEFORE SWITCHING ON OR OFF.
BATTERY MAY ALWAYS BE LEFT ON EXCEPT FOR SHIPPING OR STORAGE.
RESET
SOLAR INPUT 120V~450V
MAX.4400W(18A)
DANGER! VOLTAGE MAY BE PRESENT ON PV INPUT WHEN INVERTER IS OPERATING..
RUN ALM
CHARGE
11/15/XXXX 15:15
Home Settings Information
Alerts
PV 120VAC 12VDC
2560 W
2560 W ECO
2500 W 120 W
330 W
100%
AC Load AC ON
4
DC Load DC OFF
Fig. 6 .1 Battery power setup
1 . With all cables disconnected, press the Battery Switch to connect the
battery. Touchscreen will light up.
2 . Wait until the Bluetooth signal is ready. Note: Bluetooth icon is
highlighted blue.
3a . Press AC Output once to turn on the Inverter. Note: The AC switch will
toggle to ON then OFF.
3b . Press AC Output again to turn on the Inverter. Note: AC Output is now
enabled.
4 . Turn AC Output or DC Output on/off as needed.
17
Hysolis Apollo 5K Manual – Primary V20240108P.indd 17
1/8/24 9:58AM
6 .1 .2 AC Power
12VDC
2VDC MAX 30
PD60W 5V 2.4A QC 3.0 PD60W
MAX 30A
12VDC 2A
Home Settings
Data Warnings
11/15/XXXX 15:15
PV 120VAC 12VDC
2560 W
2560 W
2500 W 120 W
330 W
100%
INV. RESTART
AC Load AC ON
DC Load DC OFF
AC OUTPUT MAX 15A
AC OUTPUT MAX 25A
ALTERNATE AC OUTPUT MAX 25A
I n v e r te AC Inp
A
S witch
S witch 1
3
1
MAX · 35A AC INPUT
r R eset
ut R es et
COM1
COM2
AC OUTPUT
COMM.PORT
12V/24V MAX · 10A DC INPUT
BATTERY 1 51.2VDC
CAUTION!
SWITCH BATTERIES OFF BEFORE CONNECTING OR DISCONNECTING BATTERY CABLES.
CAUTION!
ONLY CONNECT HYSOLIS 5K BATTERIES. DO NOT USE 3RD-PARTY BATTERIES. CONNECTING
THE WRONG BATTERY MAY DAMAGE THE UNIT AND/OR HARM THE USER.
BATTERY 2 51.2VDC
Battery Switch
NOTICE! DISCONNECT ALL INPUT AND OUTPUT CABLES BEFORE SWITCHING ON OR OFF.
BATTERY MAY ALWAYS BE LEFT ON EXCEPT FOR SHIPPING OR STORAGE.
RESET
SOLAR INPUT 120V~450V
MAX.4400W(18A)
DANGER! VOLTAGE MAY BE PRESENT ON PV INPUT WHEN INVERTER IS OPERATING..
RUN ALM
CHARGE
Home Settings Information
Alerts
2
11/15/XXXX 15:15
PV 120VAC 12VDC
2560 W
2500 W 120 W
2560 W ECO
330 W
AC Load AC ON
5
100%
DC Load DC OFF
Fig. 6 .2 AC power setup
4
1 . With all cables disconnected, press the Battery Switch to connect the
battery. Touchscreen will light up.
2 . Wait until the Bluetooth signal is ready. Note: Bluetooth icon is
highlighted blue.
3 . Plug the AC charging cable into the AC Input port.
4 . Plug the AC charging cable to the 110V/120V power source. Note: The
inverter will be started automatically.
5 . Turn AC Output or DC Output on/off as needed.
18
Hysolis Apollo 5K Manual – Primary V20240108P.indd 18
1/8/24 9:58AM
I n v e r te AC Inp
A
S witch
S witch 1
6 .1 .3 PV (solar) Power
12VDC
2VDC MAX 30
PD60W 5V 2.4A QC 3.0 PD60W
MAX 30A
12VDC 2A
Home Settings
Data Warnings
11/15/XXXX 15:15
PV 120VAC 12VDC
2560 W
2560 W
2500 W 120 W
330 W
100%
INV. RESTART
AC Load AC ON
DC Load DC OFF
AC OUTPUT MAX 15A
AC OUTPUT MAX 25A
ALTERNATE AC OUTPUT MAX 25A
MAX · 35A AC INPUT
1
12V/24V MAX · 10A DC INPUT
2
11/15/XXXX 15:15
Home Settings Information
Alerts
PV 120VAC 12VDC
2560 W
2500 W 120 W
2560 W ECO
330 W
AC Load AC ON
4
100%
DC Load DC OFF
Fig. 6 .3 PV (solar )power setup
3
r R eset
ut R es et
COM1
COM2
AC OUTPUT
COMM.PORT
BATTERY 1 51.2VDC
CAUTION!
SWITCH BATTERIES OFF BEFORE CONNECTING OR DISCONNECTING BATTERY CABLES.
CAUTION!
ONLY CONNECT HYSOLIS 5K BATTERIES. DO NOT USE 3RD-PARTY BATTERIES. CONNECTING
THE WRONG BATTERY MAY DAMAGE THE UNIT AND/OR HARM THE USER.
BATTERY 2 51.2VDC
Battery Switch
NOTICE! DISCONNECT ALL INPUT AND OUTPUT CABLES BEFORE SWITCHING ON OR OFF.
BATTERY MAY ALWAYS BE LEFT ON EXCEPT FOR SHIPPING OR STORAGE.
RESET
SOLAR INPUT 120V~450V
MAX.4400W(18A)
DANGER! VOLTAGE MAY BE PRESENT ON PV INPUT WHEN INVERTER IS OPERATING..
RUN ALM
CHARGE
3
1 . With all cables disconnected, press the Battery Switch to connect the
battery. Touchscreen will light up.
2 . Wait until the Bluetooth signal is ready. Note: Bluetooth icon is
highlighted blue.
Important! Ensure the Apollo 5K system is grounded when connecting a full-
sized solar array.
Grounding can be done via the ground port on the back of the unit using the
included ground rod and cable or by simply connecting the unit’s AC Input to a
wall outlet in the home.
3 . Plug into solar power (Voc. Range 60V DC ~ 500V DC, Max. Charging Power
4,400W, Max. Input 5,000W/18A) using the included Solar Input Breaker.
Connect all cables when Breaker is in the OFF position. After cables are
connected, flip Breaker ON. Note: The inverter will be started automatically.
4 . Turn AC Output or DC Output on/off as needed.
19
Hysolis Apollo 5K Manual – Primary V20240108P.indd 19
1/8/24 9:58AM
I n v e r te AC Inp
A
S witch
S witch 1
6 .1 .4 Turn the Power OFF
12VDC
2VDC MAX 30
PD60W 5V 2.4A QC 3.0 PD60W
MAX 30A
12VDC 2A
Home Settings
Data Warnings
11/15/XXXX 15:15
PV 120VAC 12VDC
2560 W
2560 W
2500 W 120 W
330 W
100%
INV. RESTART
AC Load AC ON
DC Load DC OFF
AC OUTPUT MAX 15A
AC OUTPUT MAX 25A
ALTERNATE AC OUTPUT MAX 25A
Home Settings
Data
Warnings
MAX · 35A AC INPUT
r R eset
ut R es et
COM1
COM2
AC OUTPUT
COMM.PORT
12V/24V MAX · 10A DC INPUT
BATTERY 1 51.2VDC
CAUTION!
SWITCH BATTERIES OFF BEFORE CONNECTING OR DISCONNECTING BATTERY CABLES.
CAUTION!
ONLY CONNECT HYSOLIS 5K BATTERIES. DO NOT USE 3RD-PARTY BATTERIES. CONNECTING
THE WRONG BATTERY MAY DAMAGE THE UNIT AND/OR HARM THE USER.
BATTERY 2 51.2VDC
Battery Switch
NOTICE! DISCONNECT ALL INPUT AND OUTPUT CABLES BEFORE SWITCHING ON OR OFF.
BATTERY MAY ALWAYS BE LEFT ON EXCEPT FOR SHIPPING OR STORAGE.
RESET
SOLAR INPUT 120V~450V
MAX.4400W(18A)
DANGER! VOLTAGE MAY BE PRESENT ON PV INPUT WHEN INVERTER IS OPERATING..
RUN ALM
CHARGE
1 2 3
11/15/XXXX 15:15
PV 120VAC 12VDC
2560 W
2500 W 120 W
2560 W ECO
AC Load AC OFF
4 330 W
100%
DC Load DC OFF
Fig. 6 .4 Turn power OFF
1 . Disconnect DC Input.
2 . Disconnect AC Input.
3 . Disconnect Solar Input.
4 . On the touchscreen, switch the AC Output and DC Output to the OFF
position.
Note: You do not need to turn the Battery Switch OFF. You may leave the
Battery Switch ON.
Important! If you wish to switch the battery off for long periods of
inactivity, storage, or transport, make sure all cables are disconnected
before pressing the Battery Switch off.
20
Hysolis Apollo 5K Manual – Primary V20240108P.indd 20
1/8/24 9:58AM
6.2 Touchscreens
The touchscreens provide information or settings for operation. The Home,
Data, and Warnings touchscreens provide information on the operation of the
unit. The Settings touchscreens are used to customize the unit’s settings
(Fig. 6 .5). The following sections will explain each touchscreen. Note: See
Section 8 for Error Codes.
a
Home
b
Settings
c
Information
d
Alerts
11/15/XXXX 15:15
PV 120VAC 12VDC
2560 W
2560 W ECO
2500 W 120 W
330 W
100%
AC Load AC ON
DC Load DC OFF
Fig. 6 .5 Homepage UI screen
a . Home Touchscreens: Select to see real-time information on the AC input, AC
output, DC input, DC output, PV (solar) input, and the battery status.
b . Settings Touchscreens: Select to set the settings for the Working Mode,
Energy Saver, Unattended Mode, Parallel Mode, Language, Display Settings, and
WiFi.
c . Information Touchscreens: Select to see information about the product, the
power generated by the different sources, and view the alert history.
d . Alerts Touchscreen: Select to see the current error code and time.
21
Hysolis Apollo 5K Manual – Primary V20240108P.indd 21
1/8/24 9:58AM
6 .2 .1 Home Information Touchscreen
When selecting the Home button on the Homepage UI touchscreen you can find
real-time information on the AC input, AC output, DC input, DC output, PV
(solar) input, and the battery status. Select the appropriate button to see
the desired information. (Fig. 6 .6).
PV Input
Power Voltage Current
AC Input
Power Voltage Current Frequency
DC Charge
Power Voltage Current
Back
2870 W
142.5 V
a
20.5 A
Home
Back
2670 W 120.5 V 22.5 A 49.99 Hz
b
Settings
Information
Back
120 W
13.8 V
c
8.6 A
Alerts
11/15/XXXX 15:15
PV 120VAC 12VDC
2560 W
2560 W ECO
2500 W 120 W
330 W
100%
AC Load AC ON
DC Load DC OFF
Fig. 6 .6 Information screens
a . PV (solar) Input Information: Selecting the PV (solar) button on the
Homepage UI touchscreen will show the real-time running status of Power,
Voltage, and Current.
b . AC Input Information: Selecting the 120VAC button on the Homepage UI
touchscreen will show the real-time running status of Power, Voltage, Current,
and Frequency.
c . DC Input Information: Selecting the 12VDC button on the Homepage UI
touchscreen will show the real-time running status of Power, Voltage, and
Current. 22
Hysolis Apollo 5K Manual – Primary V20240108P.indd 22
1/8/24 9:58AM
Homepage UI screen (continued)
Home Settings Information
Alerts
11/15/XXXX 15:15
PV 120VAC 12VDC
2560 W
2560 W ECO
2500 W 120 W
330 W
100%
AC Load AC ON
DC Load DC OFF
AC Output
Loads
d
Voltage
Current
Frequency
Back
85 % 120.5 V 22.5 A 49.99 Hz
Battery
Energy Available
e
Voltage
Current
Temper atur e
Back
99.5 Ah 54.8 V 41.7 A
45.9 °c
DC Output
Power
f
Voltage
Current
Back
330 W 12.8 V 25.7 A
Fig. 6 .7 Information screens
d . AC Output Information: Selecting the AC Load button on the Homepage UI
touchscreen will show the real-time running status of Loads, Voltage, Current,
and Frequency.
e . Battery Information: Selecting the Battery button on the Homepage UI
touchscreen will show the real-time running status of the Energy Available,
Voltage, Current, and Temperature.
f . DC Output Information: Selecting the DC Load button on the Homepage UI
touchscreen will show the real-time running status of Power, Voltage, and
Current.
23
Hysolis Apollo 5K Manual – Primary V20240108P.indd 23
1/8/24 9:58AM