HYSOLIS MPS3K (3 kW / 4.5 kWh) with an Inverter Power Station User Manual

June 13, 2024
HYSOLIS

MPS3K (3 kW / 4.5 kWh) with an Inverter Power Station

Function menu: From any Status screen, long press the Funct button for 5 seconds to enter the Function menu. Press DOWN or UP to scroll through the different parameters PO-P4. Then, after reaching the desired parameter PO-P4, short press Funct to highlight that parameter’s setting (the setting will be blinking). Then press DOWN or UP to change the setting.
After achieving the desired setting, press Funct so that the parameter PO-P4 is blinking, press DOWN or UP until “PO” is blinking, and then short press Funct to save the setting and exit the Function menu (you can change multiple parameter settings before exiting). The functions of PO-P4 are as follows:

Main Menu Functions
P4 Buzzer mode
P3 Inverter charging current
P2 N/A (This parameter is intentionally left blank)
P1 Inverter operating mode
PO Save & Exit

HYSOLIS MPS3K 3 kW 4.5 kWh with an Inverter Power Station - Figure
1

Parameter Settings

3.3.5.1 AC Input Alarm setting
From any Status screen, long press the Function button for 5 seconds to enter the Function menu. Press DOWN or UP until the Beeper noise parameter “P4″ is blinking. Press the Function button to highlight the setting (“OFF” or “ON” will be  blinking). Turn On/Off the Alarm noise using the DOWN or UP button. Press the Function button so that “P4” is blinking, press DOWN or UP until “PO” is blinking, and then press the Function button to save and exit.
Explanation: When this setting is ON, an alarm sounds every 15-seconds if the inverter is running without AC input connected. When this setting is OFF, this particular alarm is disabled. All other operational/fault alarms remain enabled  in either setting. HYSOLIS MPS3K 3 kW 4.5 kWh with an Inverter
Power Station - Figure 2

Inverter AC charging current setting

From any Status screen, long press the Funct button for 5 seconds to enter the Function menu. Press DOWN/UP until the Inverter charging current parameter “P3” is blinking. Press the Funct button to highlight the setting (the % value will be blinking). Press DOWN or UP to change the AC charging current of the unit (100%, 80%, 60%, 40%, or 20% of maximum capacity). Press the Funct button so that “P3” is blinking, press DOWN or UP until “PO” is blinking, and  then press the Funct button to save and exit.

HYSOLIS MPS3K 3 kW 4.5 kWh with an Inverter Power Station - Figure
3

Error codes and solutions

Error code Problem Solution
MOSFETS board over-current Turn unit OFF and ON. If problem persists,

contact support.
| Output short circuit| Inspect loads for signs of short circuit (e.g. bare wires,  contact damage, etc.). Remove loads.
| Output overload| View Inverter Load % via Status screen. Remove unnecessary loads.
| Internal Temperature above Limit| Check cooling fan operation.
Remove any dust. Maintain 10cm free space around unit.
| Battery over-voltage| Check external battery connection, configuration, and voltage (see section 4.4).
| Battery under-voltage| Make sure battery is fully charged. If problem persists, battery must be replaced.
Contact support.
| Reversed connecting cables between transformer and heatsink on power board| Cables must be reconnected.
Contact support.
| Start Protection from low output voltage| Turn unit OFF and ON. If problem persists, contact support.