EIPL PV-300 Portable Ventilator User Manual

May 15, 2024
EIPL

**EIPL PV-300 Portable Ventilator User Manual

**

INTRODUCTION

This user manual tells you how to operate the PV. Please read thoroughly before operating the unit.. If you have any questions please contact our Customer Services Department at the address shown at the back of this section or phone 01388 664400.

IMPORTANT

Your PV is packed in a plastic wrapping – please ensure that it is disposed of safely and where it will not be a danger to small children

UNPACKING

Carefully remove the unit from it’s transit box and wrapping, and visually check for any signs of transit damage. If there are any signs of damage or parts missing DO NOT attempt to operate the unit, call your supplier for advice. Retain the packaging for further use, or dispose of it considerately

GENERAL

The PV should only be operated in the horizontal position and with the unit standing on a firm, level floor. A flexible duct can be attached to either the inlet or the outlet in order to transport the air over longer distances
To reduce risk of fire or electric shock, do not expose to water. This unit is for indoor use only.

SWITCHING ON

The PV ON/OFF switch is located underneath the handle on top of the unit. To start the unit simply switch over the toggle.

Since the PV has a considerable high suction power, always ensure that the Inlet grille is kept free of any obstruction during operation.

SWITCHING OFF

Switch over the toggle to its original position. Turn off the power and disconnect.

ELECTRICAL CONNECTIONS

IMPORTANT – The wires in the mains lead are coloured in accordance with the following code :-
GREEN & YELLOW ——— EARTH
BLUE ————————— NEUTRAL
BROWN ———————– LIVE

As the colors of the wires in the mains lead of this appliance may not correspond with the cultured markings identifying the terminals in your own plug, proceed as follows.
The wire which is cultured Green and Yellow must be connected to the terminal marked E or by the Earth Symbol or cultured Green or Green and Yellow. The wire which is cultured Blue must be connected to the terminal in the plug which is marked with the letters N or cultured Black. The wire which is cultured Brown must be connected to the terminal which is marked with the letter L or cultured Red.

You must safely dispose of the non rewireable plug once it has been removed from the flexible cord. It is dangerous to attempt to insert the plug into any electrical socket.

CHANGING THE FUSE

Only 13 amp fuses that are ASTA approved to BS1362 should be used.

NON REWIREABLE PLUGS

The fuse cover must be refitted after replacement of the fuse

SERVICE

This machine should be serviced by qualified EIPL personnel or other persons having technical competence in servicing refrigeration equipment following the instructions in the Beak Service Manual.

SPARES

Full spare parts listings and EIPL Service Manuals are available upon request by contacting one of the EIPL Service Centers listed in this manual.

TECHNICAL SPECIFICATION

| PV-200| PV-250| PV-300|
---|---|---|---|---
Part number| 1092660| 1092670| 1092680|
Height| 330| 370| 405| mm
Width| 250| 295| 340| mm
Depth| 290| 300| 345| mm
Weight| 6.7| 8.8| 9.5| kg
Power| 165| 240| 315| W
Voltage| 230| 230| 230| V
Airflow| 2040| 3240| 4440| m3/hr
Fan Blade Día| 200| 250| 300| mm
Noise Level| 75| 80| 85| dba
Finish :| Epoxy Coated Zintec Steel.
---|---
Mobility :| Light Construction – Static Use Only.

SAFETY PRECATIONS

  • This fan is not flameproof
  • Do not use this fan in an environment for the extraction of flammable fumes
  • This appliance can be used by children from 8 years and above and persons with reduced physical, sensory or mental capabilities or lack of experience and knowledge if they have been given supervision or instruction concerning use of the application in a safe way and understand the hazards involved.
  • Children shall not play with the appliance.
  • Cleaning and user maintenance shall not be made by children without supervision.
  • If the SUPPLY CORD is damaged, it must be replaced by the manufacturer, its service agent or similarly qualified person in order to avoid hazard.
  • DO NOT operate with safety grilles removed
  • DO NOT use in dusty or chemical fume environments
  • DO NOT use in wet areas / environments e.g. steamy areas like bathrooms or swimming pools
  • DO NOT use if the power cord or outer drum is damaged
  • DO NOT cover or obstruct the safety grilles
  • DO NOT poke objects into the safety grilles or foul the impellor
  • DO NOT use if the impellors are damaged at all

UK Head Office
Ebac Industrial Products Ltd
St Helens Trading Estate
Bishop Auckland
County Durham
DL14 9AD

Tel : +44 (0) 1388 664400
Fax : +44 (0) 1388 662590

www.eipl.co.uk
sales@eipl.co.uk

American Sales Office

Ebac Industrial Products Inc
700 Thimble Shoals Blvd.
Suite 109, Newport News
Virginia, 23606-2575
USA

Tel : +01 757 873 6800
Fax : +01 757 873 3632

www.ebacusa.com
sales@ebacusa.com

German Sales Office

Beak Industrial Products Ltd.
Greenfelder Str. 29-37
Gebäude 35
D-13599, Berlin
Germany

Tel : +49 3043 557241
Fax : +49 3043 557240

www.eip-ltd.de
sales@eip-ltd.de

References

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>

Related Manuals