SITERWELL GS511-B-H61 Smoke Alarm User Manual
- June 4, 2024
- SITERWELL
Table of Contents
GS511-B-H61 Smoke Alarm
User Manual
GS511-B-H61 Smoke Alarm
Thank you for purchasing our smoke alarm!
Please read these instructions carefully and store them in a safe place where
you can access them easily.
Product description and intended use
This is a smoke alarm with a radio link function with an optical sensor for
installation in residential buildings, apartments, and rooms with residential-
like use. Smoke alarms are designed to provide an early warning of fire smoke
and fires to persons present so that these persons can react appropriately to
the hazardous event. Always consult local regulations for smoke alarms.
Product specifications
Detection method | Optical |
---|---|
Power supply | Sealed battery 3V DC |
Battery lifetime | 10 years |
Alarm volum | 85 dB (A) at 3 meters |
Monitored area | 40 m’ |
Operating temperature | 0 °C – 45 °C |
Operating humidity | < 93 % |
Date of replacement | See product label |
Individual alarm iindicator | Yes |
Alarm silence facility | Yes I Hush time |
Low battery warning | 10±1 minutes |
Low battery silence facility | Yes |
Installation in leisure | Yes I Hush time |
accommodation vehicles | 10 hours |
Mounting location | No |
Interconnectable | Ceiling or wall |
Wireless frequency | Yes I max. 40 Devices 915.3 MHz |
Wireless distance | Max. 100 meters |
Warnings:
- To prevent injury, this apparatus must be securely attached to the ceiling/wall in accordance with the installation instructions.
- Batteries should not be exposed to excessive heat such as sunshine, fire or the like.
- Do not paint or cover the smoke alarm.
Where to install a smoke alarm
Smoke alarms must be installed in such a way that they can be reached unhindered by the fire smoke so that fires can be reliably detected during the development phase.
- Install at least in sleeping areas (especially children’s rooms).
- Install at least in escape rooms.
- In the middle of the ceiling of a room.
- At least 50 cm away from the wall and other objects.
- Maximum installation height of 6 meters.
- If ceiling installation is not possible, the smoke alarm can be installed on the wall. The distance to the ceiling should be between 30 and 50 centimeters.
Where to install a smoke alarm in rooms with special geometries
- Corridors with a maximum width of 3m: Max. 15m between 2 smoke alarms. Max. 7,5m to the front side of the gallery and smoke alarms at edges/crossings of corridors.
- Rooms with sloping ceilings: – If the ceiling Inclination is > 20° to the horizontal: Smoke alarms must be installed at least 0.5 m and at most 1 m from the ceiling top.
– Partial roof slopes: If the flat ceiling is k lm wide, consider as ceiling inclination is of > 20°. If the flat ceiling is >lm wide, consider a flat Ceiling. Rooms with subdivided ceilings:
– Height of the subdivisions is k 0.2 m: Beams without consideration; smoke alarm may be Installed on the beams as well as on the ceiling.
– Height of subdivisions is > 0.2 m and area of ceiling panels > 36 m’: Smoke alarm should be installed in each ceiling panel.
– Height of subdivisions > 0.2 m and area of ceiling panels 5 36 m2: Individual ceiling without consideration.
Where not to install a smoke alarm
- In an environment with a high risk of drought (e.g. close to air conditioning, fans and ventilation outlets). The movement of air can Impair the penetration of fire smoke Into the smoke alarm.
- Areas where combustions regularly occur, such as kitchens.
- Areas with high humidity such as bathrooms, or close to devices such as dishwashers or washing machines.
Activation
Before commissioning the smoke alarm, it is important to activate it and test
It for correct operation.
- Use a screwdriver to push the activation switch to the right. When the smoke alarm is activated, the LED lights up.
- Test the correct activation of your smoke alarm by pressing the test button. If no sound is generated, the smoke alarm is not activated properly and should not be used!
Connect your smoke alarms
- Choose one smoke alarm as the master smoke alarm.
- Turn your master smoke alarm into the connect mode by quickly pressing the test button 3 times.
- The red LED will light up red, followed by the blue LED. This indicates that the smoke alarm turned Into the connect mode In which It remains for 30 seconds.
- Turn the next smoke alarm into the learn mode by quickly pressing the test button 3 times.
- The red LED will light up, followed by the green LED. This indicates that the smoke alarms are connected to each other.
- Repeat steps 1 to 5 for connecting more smoke alarms. Make sure that you always use the same master smoke alarm!
- Test if your smoke alarm was connected successfully by pressing the test button of a random device until it beeps. The red LED of all connected devices will flash twice per second for five minutes. Stop these alarms by pressing the test button of each alarm.
Reset connection
- Disconnect the smoke alarm you want to reset by removing it from the mounting plate, or by pushing the activation switch to the left with a screwdriver.
- Press and hold the test button and activate the smoke alarm again by pushing the activation switch to the right.
- Hold the test button while the LED lights up red and release it when the LED turns of.
- When the LED lights up again, press the test button.
- The LED will start flashing to indicate that it the network is being cleared.
- When the LED turns off, the connection is successfully cleared.
- Repeat steps 1 to 6 for disconnecting more smoke alarms.
Connect Your smoke alarms
Test if t smoke alarm beeps. the red LED of all connected devices sh twice per
second for alarm.
Reset Connection
Mounting
- Place the mounting plate on the desired installation location and mark where the holes should be drilled.
- Drill two holes with a diameter of 5 millimeters.
- Push the plastic plugs into the holes.
- Insert the screws into the mounting plate, and tighten them firmly into the plugs.
- Place the smoke alarm on the mounting bracket and secure it by turning it clockwise.
- Test the correct operation of your smoke alarm by pressing the test button. If no sound is generated, the smoke alarm is not functioning properly and should not be used I
Alarm silence facility
When the smoke alarm has detected smoke and turns into alarm mode, you can
mute the alarm for approx 10±1 minutes by pressing the test button. After
that, the smoke alarm automatically resets and returns to the normal operation
mode. If there are still particles of combustion in the air, the smoke alarm
will turn into alarm mode again. WARNING: Before using the alarm silence
facility, always identify the cause of the alarm and make sure that the
circumstances are safe.
Low battery mode
When the battery is running low, the smoke alarm will indicate this with a
repetitive beep and flash for approximately 30 days. WARNING: This smoke alarm
is equipped with a non-replaceable battery. When this warning occurs, replace
the device as soon as possible! The acoustic low battery warning signal can be
muted for ten hours by pressing the test button. The smoke alarm is still
functioning and able to detect smoke when it’s in this mode.
Fault warning mode
When the smoke alarm is not functioning properly, it will turn into fault
warning mode. Try cleaning the smoke alarm (see paragraph maintenance) or
replace the smoke alarm!
Maintenance
- Test this smoke alarm weekly for correct operation using the test facility. If the smoke alarm functions correctly, it will generate a loud beep. Due to the loudness of the alarm, make sure that you always stand at arm’s length distance from the unit when you are testing. If the smoke alarm does not generate an acoustic signal, the smoke alarm must be replaced immediately!
- Clean the smoke alarm at least once per month to remove dirt, dust or debris. Use a vacuum cleaner with a soft brush and vacuum all sides and covers of the smoke alarm. Do not remove the top cover of the smoke alarm to clean it inside.
- Do not attempt to repair this smoke alarm. If the smoke alarm shows damage related to its functionality, it must be replaced!
- Troubleshooting: False alarm is often caused by dust or steam.
Recycling and disposal
The WEEE symbol means that this product and batteries must be disposed of
separately from other household waste. When they reach their end of life, take
them to a designated waste collection point in your area to guarantee safe
disposal or recycling. Protect the environment, human health, and natural
resources!
FCC warning:
Any Changes or modifications not expressly approved by the party responsible
for compliance could void the user’s authority to operate the equipment.
Note: This equipment has been tested and found to comply with the limits
for a Class B digital device, pursuant to part 15 of the FCC Rules. These
limits are designed to provide reasonable protection against harmful
interference in a residential installation. This equipment generates uses and
can radiate radio frequency energy and, if not installed and used in
accordance with the instructions, may cause harmful interference to radio
communications. However, there is no guarantee that interference will not
occur in a particular installation. If this equipment does cause harmful
interference to radio or television reception, which can be determined by
turning the equipment off and on, the user is encouraged to try to correct the
interference by one or more of the following:
– Reorient or relocate the receiving antenna.
– Increase the separation between the equipment and receiver.
– Connect the equipment to an outlet on a circuit different from that to which
the receiver is connected.
– Consult the dealer or an experienced radio/TV technician for help.
This equipment complies with FCC radiation exposure limits set forth for an
uncontrolled environment. This equipment should be installed and operated with
a minimum distance of 20cm between the radiator & your body.
IC warning
This device complies with Industry Canada licence-exempt RSS standard(s).
Operation is subject to the following two conditions: (1) This device may not
cause interference, and (2) This device must accept any interference,
including interference that may cause undesired operation of the device.
Identification
Product Type | Smoke alarm |
---|---|
Item number | GS511-B-H61 |
Manufacturer | Sitwell Electronics CO., |
Limited | No.666 Qingfeng Road,Jiangbei District, |
Website | www.china-siter.com |
Dop: (GS511-B-H61)-CPR-001
EN: 14604:2005/AC:2008 0359
Fire Safety
ESSENTIAL CHARACTERISTICS: PASSED
Nominal activation conditions/ Sensitivity, Response delay (response time),
and Performance under fire conditions – Operational reliability – Tolerance to
supply voltage – durability of operational reliability and response delay,
temperature resistance, vibration resistance, humidity resistance, corrosion
resistance, electrical stability Download the Declaration of Performance at
www.china-siter.com.