PRODUCT SPECIFICATIONS

Power:| built-in DC3V(CR-2/3AZ) Lithium battery| Alarm Volume:|

85dB(A) at 3 meters
---|---|---|---
Operation Current:| <8uA (standby), <70mA (alarm)| Alarm Sensitivity:| 1.6-2.74%/ft OBS
Sensor Type:| Photoelectric| Comply With:| UL217 &CAN/ULC-S531

OPERATION

Activation: Press test button and hold it for more than 3 seconds until LED lights, and release it within 2 seconds, the unit will generate a “beep” indicating that it is activated and ready to detect status.
CAUTION : this unit must activated prior to installation. Failure to perform step will result in a non functioning smoke alarm!
Testing: Test the unit weekly to ensure proper operation by pressing the test button.
This will sound the alarm if the electronic circuitry, horn, and battery are working properly. If no alarm sounds, the battery may be depleted or another problem. DO NOT use an open flame to test your alarm, you could damage the alarm o ignite combustible materials and start
a structure fire.
CAUTION: Due to the loudness (85 decibels) of the alarm, Always stand an arms-length away from the unit when testing.
Test the alarm weekly to ensure proper operation. Erratic or low sound coming from your alarm may indicate defectives alarm.
LED indicators: This smoke alarm is equipped with red LED indicators. Standby.

Condition: The red LED will flash every 40 seconds to indicate that the smoke alarm is operating properly.
Alarm Condition: When the alarm senses products of combustion and goes into alarm, the red LED will flash rapidly (one flash per second).The rapid flashing LED and pulsating alarm will continue until the air is cleared or the test button is released. Silence
Condition: The red LED will flash every 8 seconds as long as the alarm is in Hush mode.
Low battery trouble indication: An intermittent “chirp” accompanied by a red LED flash every 40 seconds indicates allow battery, you may press the test button to silence the trouble indication for 10 hours, but it will reset automate calmly after 10 hours. During this condition the unit will continue to operate normally and detect smoke and sound an alarm. This action only temporarily silences the chirp.
NOTE: As the battery in this unit is not replaceable, a low battery signal is an indication of end of life. Therefore the alarm MUST be replaced as soon as possible!
Fault indication: This chirp will occur between the flashes of the red LED indicator light. Battery discharge.
Condition: The red LED will always light ( This is another red LED of other position).
NOTE: When the unit chirps once every 40 seconds, pressing the test button temporarily silences this warning tone for 10 hours.

INSTALLATION NOTE

  • When mounting an alarm on the ceiling, locate it at a minimum of 4″ (10cm) from the side wall (see figure 1).
    mounting an alarm

  • When mounting the alarm on the wall, use an inside wall with the top edge of the alarm at a minimum of 4%(10cm) and a maximum of 12°(30.5cm)below the ceiling s — (see figure 1).

  • Put smoke alarms at both ends of a bedroom hallway or large room if the hallway or room is more than 30 ft (9.1 m) long. Figure 1

  • Install Smoke Alarms on sloped, peaked or cathedral ceilings at or within 3 ft (0.9m) of the highest point (measured horizontally). NFPA72 states: “Smoke alarms in rooms with ceiling slopes greater than 1 ftin 8 ft (.3m in 2.4m) horizontally shall be located on the high side of the room. * NFPA 72 states: “A row of alarms. shall be spaced ac’usmated within 3 ft (0.9m) of the peak of the ceiling measured horizontally” (see figure 2).
    smoke alarms

SINGLE FLOOR PLAN
SINGLE FLOOR PLAN Figure 3

If you are not sure about the insulation in your mobile home, or if you notice that the outer walls and ceiling are either hot or cold, install the alarm on an inside wall. For — olm minimum protection, install at least one alarm close to the bedrooms. For additional protection, see SINGLE FLOOR PLAN in Figure 3 and MULTIPLE FLOOR PLAN in Figure 4.
MULTIPLE FLOOR PLAN

Smoke Alarms for Minimum Protection
Smoke Alarms for Additional Protection
**lionization Type Smoke Alarm with Alarm Silencer or Photoelectric Type

**

Ningbo Stepwell Import & Export Co., Limited
Address: 706 Gutting Building, Huffing Creative Plaza, Jiang Dong District, Ningbo Zhejiang Province, China TEL:0086-574-87729581
E-mail: Service@china-siter.com
Fax: 0086-574-87729581 http://www.china-siter.com

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>

Related Manuals