diymore 6133A DC 12V Battery Capacity Monitor Instruction Manual

May 15, 2024
Diymore

diymore 6133A DC 12V Battery Capacity Monitor

diymore-6133A-DC-12V-Battery-Capacity-Monitor-product

Product Specifications

  • Voltage detection range: DC8-100V
  • Working current: 15mA
  • Display mode: LCD screen
  • Display color: Blue/White/Color (optional)

Product Usage Instructions

  • Mode Settings
    To access the mode settings page, long press the upper right corner button on the home screen for 2 seconds. To exit the settings page and return to the home screen, long press the upper right corner button for another 2 seconds.

  • Parameter Settings for Lead-Acid Battery
    In the lead-acid battery setting page, the voltage value will flicker. Short press the button in the lower right corner to select the battery voltage required. After selecting the voltage, press the button to confirm.

  • Ternary Lithium / Iron Lithium Battery
    The product supports measurement for ternary lithium batteries from L03 string to L20 string with power-off memory. It also measures lead-acid battery P at DC12V, 36V, 48V, 60V, 72V, 84V with power memory and lithium iron battery F from F03 to F23 string with power memory.

  • Custom High and Low Voltage Settings
    You can set custom high and low voltage ranges within the DC8-100V range.

  • Display Backlight Settings
    In the backlight setting page, you can choose between ON and OFF modes. ON mode automatically turns off the display after a 10-second delay, while OFF mode keeps the display always on. Press the bottom right corner button to select ON or OFF. Press the top right corner button to confirm and save options. Long press the top right corner button for 2 seconds to return to the main page.

  • Low Voltage Alarm Settings
    You can set low voltage alarm thresholds for timely notifications.

  • Alarm Sound Setting
    You can configure alarm sound settings for specific alerts.

Frequently Asked Questions (FAQ)

  • Q: How do I reset the device to factory settings?
    A: To reset the device to factory settings, navigate to the settings menu and look for the reset option. Confirm the reset action to restore the device to its original settings.

  • Q: Can I use this product with both lead-acid and lithium batteries?
    A: Yes, this product supports both lead-acid and lithium batteries. Follow the specific instructions provided in the manual for accurate measurements and settings.

6133A electric quantity detector instruction manual

Product parameters

  1. voltage detection range: DC8-100V
  2. working current: ≤15mA
  3. display mode: LCD screen
  4. display color: blue/white/color (optional)

Performance indicators

  1. detection accuracy: ±1%
  2. hole size: 58.5*28.5mm
  3. refresh speed: 500ms/ time
  4. Overall size: 61.333.313.5mm

The product description

  1. ternary lithium L measurement from L03 string to L20 string (power off memory)
  2. lead acid battery P measurement: DC12V, 36V, 48V, 60V, 72V, 84V (power memory)
  3. lithium iron battery F measurement from F03 string to F23 string (power memory)
  4. custom set high and low voltage range: DC8-100V

Model specification

Long press the upper right corner button on the home screen for 2 seconds to enter the mode Settings page, and long press the upper right corner button for another 2 seconds to exit the Settings page and return to the home screen

  • Mode 1 – Lead acid P setting;

  • Mode 2 – ternary lithium L setting;

  • Mode 3 – Lithium iron F setting;

  • Mode 4 — Custom high and low voltage Settings: Custom low voltage and saturation voltage, display 00.0 000, left digit is the low voltage parameter, right
    The number is the saturation voltage parameter;

  • Mode 5 — backlight setting: Display 5-B, short press the button in the lower right corner to switch ON/OFF, ON is to automatically turn OFF the backlight after 10S delay, OFF is The backlight is always on;

  • Mode 6 – low voltage alarm Settings: display 00.0V Lo, the left is the alarm voltage parameter (voltage below this parameter alarm);

  • Mode 7 — alarm sound setting: Display 7-A, short press the button in the lower right corner to switch ON/OFF, ON is to open the alarm sound function, OFF is to shut down Alarm sound function (this function needs to be selected when purchased)

Note: there are two kinds of lithium batteries (ternary lithium L and iron lithium F), teach you to distinguish;First charge the battery first, a string of three yuan lithium battery The saturation voltage is DC4.2V, and the saturation voltage of lithium iron battery is DC3.6V.For example: saturation voltage shows 84V (20 strings), this one
It is a ternary lithium battery, and then select parameters according to the setting mode of ternary lithium battery

Parameter Settings

Lead-acid battery

diymore-6133A-DC-12V-Battery-Capacity-Monitor- \(1\) In the lead-acid battery setting page, the voltage value flickers, short press the button in the lower right corner to select the battery voltage that needs to be used, after selecting the voltage, the short.

Ternary lithium

diymore-6133A-DC-12V-Battery-Capacity-Monitor- \(2\)

In the ternary lithium battery setting page, the number of battery strings is flashing, and the number of battery strings to be used is selected by pressing the button in the lower right corner. After selecting the number of battery strings, press the button in the upper right corner to confirm and save the value ( the number of battery strings is always bright ), press the button in the upper right corner for 2 seconds to return to the main page, or press the button in the upper right corner for other mode settings.

iron lithium battery

diymore-6133A-DC-12V-Battery-Capacity-Monitor- \(3\)

In the ternary lithium battery setting page, the number of battery strings is flashing, and the number of battery strings to be used is selected by pressing the button in the lower right corner. After selecting the number of battery strings, press the button in the upper right corner to confirm and save the value ( the number of battery strings is always bright ), press the button in the upper right corner for 2 seconds to return to the main page, or press the button in the upper right corner for other mode settings. Lithium iron battery

Custom high and low voltage settings

diymore-6133A-DC-12V-Battery-Capacity-Monitor- \(4\)

On the user-defined high and low voltage setting page, 00.0 on the left side is low voltage, 000 on the right side is saturated voltage. Short press the key at the lower right corner to set the bit value. After the bit value is set, long press the key at the lower right corner for 2 seconds to shift. After the low voltage and saturated voltage are set, short press the key at the upper right corner to confirm and save the value (all values are always on), long press the key at the upper right corner for 2 seconds to return to the main page, You can also press the key on the upper right corner briefly to set other modes.

Tip : the right side of 000 is actually 00.0, such as 255 shows is 25.5

Display backlight settings

diymore-6133A-DC-12V-Battery-Capacity-Monitor- \(5\)

On the backlight setting page, ON/OFF flashes. Briefly press the button at the bottom right corner to select ON or OFF. ON: The display automatically closes after a 10 second delay. OFF: The display is always on. Briefly press the button at the top right corner to confirm and save the options. Long press the button at the top right corner for 2 seconds to return to the main page. You can also briefly press the button at the top right corner to set other modes.

Low voltage alarm settingsdiymore-6133A-DC-12V-Battery-Capacity-
Monitor- \(6\)

On the low voltage alarm setting page, 00.0 on the left is the setting value. Short press the key at the lower right corner to set the bit value. After the bit value is set, long press the key at the lower right corner for 2 seconds to shift. After the alarm voltage is set, short press the key at the upper right corner to confirm and save the value (all values are always on). Long press the key at the upper right corner for 2 seconds to return to the main page, or short press the key at the upper right corner to set other modes.

Note : If the user does not customize the low voltage alarm parameters, the product default power is less than 10 % automatic alarm prompt.

Alarm sound setting

diymore-6133A-DC-12V-Battery-Capacity-Monitor- \(7\)

On the alarm sound setting page, ON/OFF flashes, short press the button at the lower right corner to select ON or OFF, ON: turn on the alarm sound, OFF: turn off the alarm sound, short press the button at the upper right corner to confirm and save the options, long press the button at the upper right corner for 2 seconds to return to the main page, or short press the button at the upper right corner to set other modes.

Note: This product is a patent product of our company, please do not imitate, imitation must be investigated.

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>

Related Manuals