SONANCE DSP 8-130 Multi-Channel Power Amplifier
Product Information
Specifications
- Model : Sonance DSP 8-130 MKIII
- Power Output : Multi-channel power amplifier
- Control Inputs : 3-30V (AC or DC)
- Speaker Load Capability : 4-ohm stereo, 8-ohm stereo, or 8-ohm bridged mono loads
- Power Cable : 14 gauge EIA standard 120 Volt grounded
Product Usage Instructions
Getting Started
Place the amplifier in a location away from moisture.
- Connect the network jack with an ethernet cable to a network hub or switch.
- For IR control, insert a mono 3.5mm plug into the IR Control jack.
- Connect trigger lines to the Voltage Trigger terminal block and connect it.
- Connect the power cord and turn the amplifier power switch to the ON position.
Source Connections:
The DSP 8-130 MKIII ships with two Analog Input Modules. Inputs can be routed to specific zones through SonARC.
Voltage Trigger Control:
The amplifier has a 3-30V control input that can be enabled through the SonARC interface.
IR Control:
The 3.5mm jack receives IR commands and does not require enabling in the SonARC interface.
Speaker Connections:
- Connect the speaker wire (up to 12 AWG) to the provided block connector.
- For bridged operation, connect speaker wires accordingly.
- Plug the block connector into the amplifier ensuring no strain on the speaker wire.
Powering the Amplifier
Plug the provided power cable into the IEC power connector after making all system connections.
Reset Button
Pressing the RESET button for different durations initiates various reset actions including rebooting, resetting network settings, and performing a full factory reset.
FAQ
- Q: Can the amplifier drive bridged mono loads?
- A : Yes, the DSP 8-130 MKIII can drive 8 ohm bridged mono loads. Configuration can be done through SonARC.
- Q: How do I reset the amplifier to factory defaults?
- A : Press the RESET button for more than ten seconds to perform a full factory reset, erasing any user settings.
BOX CONTENTS
- (1) Quickstart Guide
- (1) Sonance DSP 8-130 MKIII Amplifier
- (1) IEC Power Cord (Region Dependent)
- (4) Amp Feet
- (2) Rack Ears
- (4) Block Connector for Speaker Outputs
- (1) Block connector for Voltage Trigger
GETTING STARTED
The Sonance DSP 8-130 MKIII comes ready-to-play audio out-of-the-box. Installers have the option to set the amplifier up using the physical controls for customization or the SonARC web interface (ethernet interface required). Sonance suggests the following installation sequence:
- Place amplifier in a location away from moisture and temperatures exceeding 100°F (38°C).
- Connect Audio Inputs.
- Connect Speaker Outputs.
- Connect the network jack with an ethernet cable from the amplifier to a network hub or switch (see the complete DSP 2-750 MKIII User’s Manual and the SonARC guide for complete details).
- For IR control, insert a mono 3.5mm plug (tip-positive) into the 3.5mm jack labeled “IR Control”.
- For the Voltage Trigger, connect trigger lines to the IN + and IN- terminals on the Voltage Trigger terminal block and connect it.
- Connect the power cord.
- Confirm inbound audio feed signals have been muted. Turn the amplifier power switch to the ON position.
SOURCE CONNECTIONS
The DSP 8-130 MKIII ships with two Analog Input Modules. By default, Inputs 1 through 4 are routed to Zones 1 through 4, respectively. Different routing can be configured through SonARC.
VOLTAGE TRIGGER CONTROL
The DSP 8-130 MKIII has a 3-30V (AC or DC) control input. The factory default setting of the amplifier is Always On or Audio-Sense. The Voltage Trigger can be enabled within the SonARC interface.
IR CONTROL
The 3.5mm jack can be used to receive IR commands from a distribution box or self-powered IR sensor. The amplifier does not provide a voltage to IR sensors. Refer to the DSP 8-130 MKIII webpage for specific IR control codes. This feature is always active, and does not need to be enabled in the SonARC interface.
SPEAKER CONNECTIONS
NOTE : The DSP 8-130 MKIII is capable of driving 4 ohm stereo, 8 ohm stereo, or 8 ohm bridged mono loads. Bridged mono load configurations require selection in the SonARC interface.
- Connect the speaker wire (up to 12 AWG) to the provided block connector. IMPORTANT: Keep all wire strands inside the plastic shell. Damage may occur if speaker wires short together or touch the amplifier housing.
- For bridged operation, connect speaker wires from LEFT+ to SPEAKER+ and RIGHT+ to SPEAKER-.
- Plug the block connector into the amplifier and check that there is no strain on the speaker wire.
POWERING THE AMPLIFIER
Plug the provided 14 gauge EIA standard 120 Volt grounded power cable into the IEC power connector.
IMPORTANT : Do not plug the power cord into the wall outlet until all system connections are made.
RESET BUTTON
Pressing the RESET button for less than five seconds will reboot the amp. Pressing the RESET button between five and ten seconds will reset the network settings to factory defaults (DHCP on). Pressing the RESET button for greater than ten seconds will perform a full factory reset, erasing any EQ changes or other user settings.
LED STATUS INDICATORS
Power Button System Status Indicator
- No Light: The amp is unpowered or the power button is turned off
- Bright White : The amp has power and is active
- Dim White: The amp has power and is sleeping
- Blinking White: The amp is in overtemperature or power supply protection, or the “Identify Amplifier” button was pressed in SonARC
Channel Status Indicators
- No Light : no audio present
- Green : audio present
- Blinking Red : audio present, the amp is overdriven
- Solid Red : the amplifier is in protection mode
Front Panel
- Illuminated Power Button
- Active Audio and Protection Indicator
- Rear Panel
- Audio Input/Output Module
- Reset Button
- IR Control Input and Passthrough
- RJ-45 Input
- AC Fuse Holder
- Speaker Output
- Voltage Control
- AC Input
Scan
Scan the QR code for additional information.
For technical support call 949.492.7777 or visit www.sonance.com
- ©2023 Sonance. All rights reserved. Sonance is a registered trademark of Dana Innovations. Due to continuous product improvement, all features and specifications are subject to change without notice. For the latest Sonance product specification information visit our website: