Lifeloc FC5 Hornet DOT Approved Evidential Breathalyzer User Manual
- May 15, 2024
- Lifeloc
Table of Contents
FC5 Hornet DOT Approved
Evidential Breathalyzer
User Manual FC5 HORNET
OPERATIONS MANUAL
FC5 Hornet DOT Approved Evidential Breathalyzer
The FC5 Hornet is a new generation of alcohol screener for use by schools,
police, probation, jails, mining and related testing in safety sensitive
industries.
Testing for the presence of alcohol has never been easier. No mouthpieces or
special attachments are required. Simple to operate, the FC5 uses icons to
eliminate misinterpretation due to language barriers.
The FC5 is alcohol specific and uses a platinum fuel cell providing users with
rapid response and reset times, as well as long working life.
The FC5 Hornet comes standard with three operating test modes used for
subject, ambient air and open container testing. Designed for safety, the FC5
allows the operator to see the test results without revealing the display to
the subject.
Components Diagram
- LCD Display: Displays test order and results with an automatic backlight for day/night visibility
- Function Button: Scrolls through test modes
- Power Button: Turns the unit on or off. Unit will automatically power off after 5 minutes of inactivity
- Execute Button: Allows you to perform functions or trigger a manual override test
- Sampling Cone: Breath should be directed to the cone in order to ensure a proper test
- Protective Grip: Covers and protects the entire unit and any exposed ports
- Battery Door: Holds 4 AA batteries that allow up to 4700 tests
Battery Installation
The FCS is designed to operate using 4 AA alkaline batteries. Remove the
battery door by pressing in and down on the door located on the lower back of
the FCS.
Install the 4 AA alkaline batteries in the direction of the symbols in the
battery case. Close the case by pushing up on the battery door until it locks
shut.
In order to change or install batteries, the grip must be removed from the
FCS.
Precautions
- Wait at least 10 minutes after drinking, smoking or inserting anything in your mouth before taking a breath test.
- Do not blow smoke into the port as it may damage the sensor.
- Alcohol leaves the body of at a conservative rate of about 0.5 oz. alcohol per hour or .015 percent of blood alcohol content (BAC) per hour. This is an average rate at which the liver can metabolize (burn off) alcohol. The result is that it can take many times longer to sober up than it took to become intoxicated. Someone with a BAC of .16 will require over 10 hours to be completely sober.
- We recommend storing the FC5 in temperatures between 32° – 130° F (0° – 55°C).
- No user serviceable parts inside. To be serviced only by an authorized FC5 technician.
Test Modes Explained
POS+/- NEG Test Mode
Perfect for zero tolerance environments, this test mode displays results as
POS + or – NEG for alcohol.
A POS + test is any alcohol level > .000 BAC.
Tests are triggered automatically once the subject exhales enough breath
towards the collector cone.
Manual override is available using the execute button for testing
uncooperative subjects or discrete ambient air.
LEVELS Test Mode
Used for more precise alcohol testing, levels test mode, will alert the
operator to levels of alcohol in the subject. Equipped with automatic testing
with manual override capabilities for difficult subjects.
Pre-Set Alcohol Levels
Zero: <.010% BAC (<.04 mg/l)
Low: .011 – .020% BAC (.05 – .09 mg/l)
High: >.021% BAC (>.100 mg/l)
OPEN CONTAINER Test Mode
Samples air-space over open drink containers or spills. With its unique double
pump action, the Open Container mode ensures sufficient test sample even from
small neck bottles. One button sample triggering allows for precise
positioning over the sample and the quiet pump action ensures discrete and
unobtrusive sampling.
Operations
Getting Started
- Turn-on the FCS by momentarily pressing the Power button. The instrument will initiate a self test and then display the POS/NEG test mode.
- To switch test modes, press the Function button and scroll through your options.
- Once test mode is selected, it will become the new default mode. You can change defaults by momentarily pressing the Power button, switching modes using the Function button or by completely powering the unit off.
- You are now ready to test.
Conducting an Automatic Test
- Position the sampling cone about 4” or 10 cm from the subject’s mouth.
- Instruct the subject to blow steadily towards the cone.
- The test will automatically trigger once the subject has provided an adequate sample.
- Read results.
- Results will stay on the screen for 30 seconds or until you press the Function button.
Conducting a Manual Test
- Position the sampling cone no less than 4” from the subject’s mouth.
- Instruct the subject to blow steadily towards the cone.
- Once the subject begins blowing, press the Execute button to trigger the test.
- Read results.
- Results will stay on the screen for 30 seconds or until you press the Function button.
Conducting an Open Container Test
- Position the sampling cone no less than 4” from the container or sample.
- Press the Execute button to trigger the test.
- Read results.
- Results will stay on the screen for 30 seconds or until you press the Function button.
- For best results, slightly agitate the sample prior to trigger the test.
Conducting an Ambient Air Test
- In any of the three modes, wave the unit in the air and press the Execute button to trigger the test.
- Read results.
- Results will stay on the screen for 30 seconds or until you press the Function button.
User Prompts
User Prompts
| Cause & Course of Action
---|---
| POS/NEG Test Mode: NEG results will register as a Zero, POS results will be
anything >0.
| Negative results when in POS/NEG Test Mode.
| Positive result when in POS/NEG Test Mode.
| Levels Test Mode: Results will register in one of three different levels
depending on the subjects alcohol content.
Zero: <.010% BAC (<.04 mg/I)
Low: .011 – .020% BAC (.05 – .09 mg/I) High: >.021% BAC (>.100 mg/I)
| Display shows results as <.010% BAC when in Levels Test Mode.
| Display shows results as .011 – .020% BAC when in Levels Test Mode.
| Display shows results as >.021 % BAC when in Levels Test Mode.
| Open Container Test Mode: NEG results will register as a Zero, POS results
will be anyting >0.
| Negative results when in Open Container Test Mode.
| Positive results when in Open Container Test Mode.
| The hourglass appears when the FC5 is in wait mode. This can occur when the
FC5 is recovering from a POS test.
Specifications
Sensor | Electrochemical Fuel Cell |
---|---|
Sampling | Passive |
Power Supply | 4 AA Batteries |
Battery Life | Approx. 4700 tests |
Operating Temp. | 32°F – 122° F (0°C – 50°C) |
Display | High Resolution Graphic Display |
Size | 1.25″ x 2.5″ x 5″ (31.7 x 63.5 x 127mm) |
Weight w/Battery | 5oz (142 grams) |
Trigger Mode | Automatic and Manual |
Warranty | 1 year limited warranty |
Calibration
All breath testers require periodic calibration to maintain their accuracy. Your FCS Hornet is designed to be calibrated by a factory certified calibration technician at least once every 12 months. To have your instrument calibrated or serviced email LifeLock at service@lifeloc.com, visit us at www.lifeloc.com, call 1.800.722.4872 or contact your local distributor.
Service & Maintenance
For general maintenance we recommend wiping the unit off with a soft cloth sprayed with a non-abrasive disinfectant cleaner. To obtain the longest life from your FC5 Hornet, it is recommended that two or three tests be taken at least every 30 days. This prevents the fuel cell from drying out over extended periods of non use. If you require service, email us at service@lifeloc.com, call 1.800.722.4872 or contact your local distributor.
Warranty
Lifeloc’s Technologies, Inc. (“Lifeloc’s”) warrants to the buyer that at the
time of shipment from Lifeloc’s facilities, all new Lifeloc’s Equipment
purchased through Lifeloc’s or one of our authorized distributors will be free
from defects in material and workmanship, under normal use and service,
provided that the buyer gives Lifeloc’s written notice of any defect within
twelve (12) months from original invoice date (the “Warranty”). The term
“Lifeloc Equipment” includes all [portable hand-held and fixed station
breathalyzers manufactured by Lifeloc], as well as all printers, keyboards,
cables, cases, and power supplies purchased as part of a new Lifeloc kit
configuration. Software is warranted to perform substantially in accordance
with Lifeloc’s user manuals and to be free from defects in materials and
workmanship under normal use and service for a period of twelve (12) months
from original invoice date.
The Warranty does not apply if the product has been altered, customized,
repaired, reported stolen or modified by someone other than a Lifeloc’s
factory authorized technician, or if parts other than Lifeloc’s approved parts
are used in replacement or repair.
The buyer’s exclusive remedy and Lifeloc’s sole liability for breach of the
Warranty shall be repair, replacement or, at Lifeloc’s option, refund of the
original purchase price paid by the buyer to Lifeloc’s for the Lifeloc’s
Equipment that is shown, to Lifeloc’s reasonable satisfaction, to be defective
in breach of the Warranty (“Defective” and, the defect causing the Lifeloc’s
Equipment to be Defective, a “Defect”). Under no circumstance shall Lifeloc’s
be liable for an amount that exceeds the lesser of the cost of replacement or
the original purchase price paid by the buyer to Lifeloc for the Lifeloc
Equipment. Lifeloc shall not be responsible for any customer software,
customer settings or configuration data or customer test records resident in
any products returned for service, repair, warranty or recertification.
Lifeloc assumes no risk for damage in transit. If Lifeloc determines that a
Defect was outside of or not covered under the Warranty, Lifeloc will estimate
repair and service charges and obtain the buyer’s authorization prior to
conducting any work to repair the Defective Lifeloc Equipment. Following
repair, the Lifeloc Equipment will be returned to the buyer via standard
ground transportation prepaid. Express charges, if authorized by the buyer,
will be invoiced at the difference between the express charges and the
standard return shipping charges.
Lifeloc shall not incur costs related to loss, damage or incomplete or
inaccurate paperwork of returned product regardless of origination point.
THIS WARRANTY IS THE PURCHASER’S SOLE AND EXCLUSIVE REMEDY AND IS IN LIEU OF
ALL OTHER WARRANTIES, EXPRESSED OR IMPLIED. LIFELOC SHALL NOT BE LIABLE FOR
ANY SPECIAL, INDIRECT, INCIDENTAL OR CONSEQUENTIAL DAMAGES OR LOSSES,
INCLUDING LOSS OF DATA, WHETHER ARISING FROM BREACH OF WARRANTY OR BASED ON
CONTRACT, TORT, RELIANCE OR ANY OTHER THEORY.
NOTWITHSTANDING ANYTHING TO THE CONTRARY IN THE FOREGOING WARRANTY, OR IN ANY
AGREEMENT BETWEEN THE BUYER AND LIFELOC PERTAINING TO ANY LIFELOC EQUIPMENT,
OR AT LAW OR IN EQUITY:
THE WARRANTIES, OBLIGATIONS, AND LIABILITIES OF LIFELOC, AND THE REMEDIES OF
THE BUYER SET OUT IN THE FOREGOING WARRANTY, ARE SOLE AND EXCLUSIVE, AND ARE
MADE AND ACCEPTED BY THE BUYER IN LIEU OF, AND THE BUYER WAIVES AND RELEASES,
ALL OTHER WARRANTIES, OBLIGATIONS, AND LIABILITIES OF LIFELOC, AND ALL OTHER
CLAIMS AND REMEDIES OF THE BUYER, EXPRESS OR IMPLIED, ARISING BY STATUTE OR
OTHERWISE, WITH RESPECT TO ANY DEFECT IN LIFELOC EQUIPMENT, INCLUDING BUT NOT
LIMITED TO THE WAIVER AND RELEASE BY THE BUYER OF THE FOLLOWING: (i) ANY
STATUTORY OR IMPLIED WARRANTY OF MERCHANTABILITY OR OF FITNESS FOR ANY
PURPOSE, (ii) ANY IMPLIED WARRANTY ARISING FROM COURSE OF DEALING, COURSE OF
PERFORMANCE OR USAGE OF TRADE, AND (iii) ANY OTHER RIGHT, CLAIM, OR REMEDY
WHATSOEVER OF THE BUYER OR OF ANY PERSON OR ENTITY CLAIMING BY, THROUGH, OR
UNDER THE BUYER AGAINST LIFELOC, WHETHER ARISING PURSUANT TO THE FOREGOING
WARRANTY, PURSUANT TO ANY AGREEMENT PERTAINING TO LIFELOC EQUIPMENT, OR IN
CONTRACT, IN INDEMNITY, IN TORT (INCLUDING, BUT NOT LIMITED TO, NEGLIGENCE),
IN PRODUCTS LIABILITY, IN STRICT LIABILITY, OR OTHERWISE. BY ACCEPTING OR
USING LIFELOC EQUIPMENT, THE BUYER FURTHER ACKNOWLEDGES, UNDERSTANDS, AND
AGREES THAT NO STATEMENT OR REPRESENTATION HAS BEEN MADE BY LIFELOC, OR RELIED
UPON BY THE BUYER, THAT IS INCONSISTENT WITH THE FOREGOING WARRANTY.
Without prejudice to the foregoing, Lifeloc shall not have any obligation or
liability, and the buyer acknowledges that Lifeloc shall not have any
obligation or liability whatsoever, to the buyer, or to any person or entity
claiming by, through, or under the buyer, whether arising pursuant to the
foregoing Warranty, pursuant to any agreement pertaining to Lifeloc Equipment,
or in contract, in indemnity, in tort (including, but not limited to,
negligence), in products liability, in strict liability, or otherwise, (i) for
any transportation, installation, removal, reinstallation, adjustment, or
other expenses related to any Lifeloc Equipment covered by the Warranty or to
other property, (ii) for any damage or loss to any property other than the
Lifeloc Equipment covered by the Warranty, or (iii) for any special, indirect,
incidental, or consequential damage or loss, even though such expenses,
damages, or losses may be foreseeable, including, but not limited to: loss of
profits or revenues, loss of use or equipment, cost of capital, cost of
substitute equipment, repairs, or facilities, cost of downtime, or cost of
purchased or replacement equipment or parts. The limited remedies of the buyer
set forth above shall be exclusive even though they may fail of their
essential purpose. No agreement varying or extending the foregoing Warranty,
no remedies, no exclusions, or no limitations shall be effective unless in a
writing signed by an executive officer of LIFELOC. The correction of any
Defect shall in no way extend the duration of the Warranty; only the unexpired
warranty term of the Lifeloc Equipment applies to any repaired or replacement
Lifeloc Equipment that is provided under the Warranty. The Warranty is non-
transferable and is effective on all Lifeloc Equipment purchased from and
after [September 1, 2014]. Rights and recourse may vary by country.
Fuel Cell Warranty*
Unless otherwise set forth in the applicable purchase agreement, Lifeloc warrants to the original purchaser of Lifeloc breath alcohol testers that the fuel cell purchased with the instrument shall operate without defect for the life of the instrument subject to the following conditions:
- Lifeloc shall, at its option, elect to repair or replace any fuel cell returned to Lifeloc as defective.
- All fuel cells returned to Lifeloc as defective become the property of Lifeloc.
- Warranty applies only to fuel cells purchased with new instruments after June 1, 2014.
- Warranty is valid only to the original purchaser of an instrument. Warranty does not pass to subsequent users if the instrument is resold, stolen, donated or given to anyone other than the original purchaser.
- Warranty is invalidated if, in the opinion of Lifeloc, the instrument has been misused, abused, modified or improperly maintained. Lifeloc shall conduct its normal billable Factory Diagnostic Test on all instruments submitted for Lifeloc Limited Lifetime Fuel Cell Warranty evaluation prior to acceptance by Lifeloc of the Lifeloc Limited Lifetime Fuel Cell Warranty claim.
- The Lifeloc Limited Fuel Cell Warranty does not apply if the product has been repaired or modified by someone other than a Lifeloc factory authorized technician and/or if parts other than Lifeloc approved parts are used in replacement or repair; or if any Lifeloc serial number has been removed or defaced.
- Upon subsequent instrument trade-in, there shall be no residual monetary value associated with the fuel cell owing to the owner.
- The Lifeloc Limited Fuel Cell Warranty does not survive past the end-of service and support life of the instrument as determined by Lifeloc Technologies in its sole discretion.
- Other than as set forth above, all Lifeloc fuel cells are subject to Lifeloc’s standard Warranty.
*Lifetime fuel cell warranty is valid throughout the US and Canada. International Customers please contact Lifeloc directly for specific terms and conditions.
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>