HIKMICRO E Series Handheld Thermal Camera
Specifications
- Product : Handheld Thermal Camera HIKMICRO E Series
- Manufacturer : HIKMICRO
- Website : www.hikmicrotech.com
Product Usage Instructions
Safety Precautions
Before using the handheld thermal camera, please read the safety information provided in the user manual carefully to ensure safe operation.
Powering On
Press and hold the power button until the device powers on. Follow any initial setup instructions that may appear on the screen.
Capturing Thermal Images
Aim the camera at the desired target and press the capture button to take a thermal image. Ensure that the camera lens is clean for accurate results.
Viewing and Analyzing Images
Use the device’s display screen to view the captured thermal images. You can also access various analysis tools and settings to enhance and interpret the images.
Saving and Transferring Data
To save images or data, follow the instructions provided in the user manual on how to store them internally or transfer them to a computer or other devices.
FAQ
- Q: Can I use the thermal camera in extreme weather conditions?
- A : The handheld thermal camera is designed to withstand a range of environmental conditions, but it is recommended to refer to the user manual for specific operating temperature ranges.
- Q: How do I calibrate the thermal camera?
- A : The user manual provides detailed instructions on how to calibrate the thermal camera properly. Follow the calibration steps to ensure accurate temperature readings.
- Q: Can I adjust the thermal imaging settings?
- A : Yes, you can adjust various settings such as color palettes, temperature scales, and image enhancements through the device’s menu options. Refer to the user manual for detailed guidance.
Regulatory Compliance and Safety Information
Read all information and instructions in this document carefully before using the device and keep it for further reference.
For more device information and instructions, please visit our website at
www.hikmicrotech.com. You can also refer to
other documents (if any) accompanying the device or scan the QR code (if any)
on the packaging to get more information.
©2023 Hangzhou Microimage Software Co., Ltd. All rights reserved.
About this Manual
The Manual includes instructions for using and managing the Product. Pictures,
charts, images, and all other information hereinafter are for description and
explanation only. The information contained in the Manual is subject to
change, without notice, due to firmware updates or other reasons. Please find
the latest version of this Manual at the HIKMICRO website
(www.hikmicrotech.com).
Please use this Manual with the guidance and assistance of professionals
trained in supporting the Product.
Trademarks
trademarks and other HIKMICRO trademarks and logos are the properties of
HIKMICRO in various jurisdictions.
Other trademarks and logos mentioned are the properties of their respective
owners.
Disclaimer
TO THE MAXIMUM EXTENT PERMITTED BY APPLICABLE LAW, THIS MANUAL AND THE PRODUCT DESCRIBED, WITH ITS HARDWARE, SOFTWARE AND FIRMWARE, ARE PROVIDED “AS IS” AND “WITH ALL FAULTS AND ERRORS”. HIKMICRO MAKES NO WARRANTIES, EXPRESS OR IMPLIED, INCLUDING WITHOUT LIMITATION, MERCHANTABILITY, SATISFACTORY QUALITY, OR FITNESS FOR A PARTICULAR PURPOSE. THE USE OF THE PRODUCT BY YOU IS AT YOUR OWN RISK. IN NO EVENT WILL HIKMICRO BE LIABLE TO YOU FOR ANY SPECIAL, CONSEQUENTIAL, INCIDENTAL, OR INDIRECT DAMAGES, INCLUDING, AMONG OTHERS,
DAMAGES FOR LOSS OF BUSINESS PROFITS, BUSINESS INTERRUPTION, OR LOSS OF DATA, CORRUPTION OF SYSTEMS, OR LOSS OF DOCUMENTATION, WHETHER BASED ON BREACH OF CONTRACT, TORT (INCLUDING NEGLIGENCE), PRODUCT LIABILITY, OR OTHERWISE, IN CONNECTION WITH THE USE OF THE PRODUCT, EVEN IF HIKMICRO HAS BEEN ADVISED OF THE POSSIBILITY OF SUCH DAMAGES OR LOSS.
YOU ACKNOWLEDGE THAT THE NATURE OF THE INTERNET PROVIDES FOR INHERENT SECURITY RISKS, AND HIKMICRO SHALL NOT TAKE ANY RESPONSIBILITY FOR ABNORMAL OPERATION, PRIVACY LEAKAGE OR OTHER DAMAGES RESULTING FROM CYBER-ATTACKS, HACKER ATTACKS, VIRUS INFECTION, OR OTHER INTERNET SECURITY RISKS; HOWEVER, HIKMICRO WILL PROVIDE TIMELY TECHNICAL SUPPORT IF REQUIRED.
YOU AGREE TO USE THIS PRODUCT IN COMPLIANCE WITH ALL APPLICABLE LAWS, AND YOU
ARE SOLELY RESPONSIBLE FOR ENSURING THAT YOUR USE CONFORMS TO THE APPLICABLE
LAW. ESPECIALLY, YOU ARE RESPONSIBLE, FOR USING THIS PRODUCT IN A MANNER THAT
DOES NOT INFRINGE ON THE RIGHTS OF THIRD PARTIES, INCLUDING WITHOUT
LIMITATION, RIGHTS OF PUBLICITY, INTELLECTUAL PROPERTY RIGHTS, OR DATA
PROTECTION AND OTHER PRIVACY RIGHTS. YOU SHALL NOT USE THIS PRODUCT FOR ANY
PROHIBITED END-USES, INCLUDING THE DEVELOPMENT OR PRODUCTION OF WEAPONS OF
MASS DESTRUCTION, THE DEVELOPMENT OR PRODUCTION OF CHEMICAL OR BIOLOGICAL
WEAPONS, ANY ACTIVITIES IN THE CONTEXT RELATED TO ANY NUCLEAR EXPLOSIVE OR
UNSAFE NUCLEAR FUEL CYCLE, OR IN SUPPORT OF HUMAN RIGHTS ABUSES.
IN THE EVENT OF ANY CONFLICTS BETWEEN THIS MANUAL AND THE APPLICABLE LAW, THE
LATTER PREVAILS.
These clauses apply only to the products bearing the corresponding mark or information.
EU/UK Compliance Statement
This product and – if applicable – the supplied accessories too are marked with “CE” and comply therefore with the applicable harmonized European standards listed under the Directive 2014/30/EU (EMCD) and Directive 2011/65/EU (RoHS).
Note : The products with an input voltage of within 50 to 1000 VAC or 75 to 1500 VDC comply with Directive 2014/35/EU (LVD), and the rest products comply with Directive 2001/95/EC (GPSD). Please check the specific power supply information for reference.
This product and – if applicable – the supplied accessories too are marked
with “UKCA” and comply therefore with the following directives:
Electromagnetic Compatibility Regulations 2016, Electrical Equipment (Safety)
Regulations 2016, the Restriction of the Use of Certain Hazardous Substances
in Electrical and Electronic Equipment Regulations 2012.
For the device without a supplied battery, use the battery provided by a
qualified manufacturer. Refer tothe product specification for detailed battery
requirements
For the device without a supplied power adapter, use the power adapter provided by a qualified manufacturer. Refer to the product specification for detailed power requirements.
Directive 2012/19/EU (WEEE
Directive): Products marked with this symbol cannot be disposed of as
unsorted municipal waste in the European Union. For proper recycling, return
this product to your local supplier upon the purchase of equivalent new
equipment, or dispose of it at designated collection points. For more
information see: www.recyclethis.info.
According to the Waste Electrical and Electronic Equipment Regulations 2013:
Products marked with this symbol cannot be disposed of as unsorted municipal
waste in the United Kingdom. For proper recycling, return this product to your
local supplier upon the purchase of equivalent new equipment, or dispose of it
at designated collection points. For more information see:
www.recyclethis.info.
Directive 2006/66/EC and its amendment 2013/56/EU (Battery Directive): This
product contains a battery that cannot be disposed of as unsorted municipal
waste in the European Union. See the product documentation for specific
battery information. The battery is marked
with this symbol, which may include lettering to indicate cadmium (Cd), lead
(Pb), or mercury (Hg). For proper recycling, return the battery to your
supplier or to a designated collection point. For more information see:
www.recyclethis.info.
According to the Batteries and Accumulators (Placing on the Market) Regulations 2008 and the Waste Batteries and Accumulators Regulations 2009: This product contains a battery that cannot be disposed of as unsorted municipal waste in the United Kingdom. See the product documentation for specific battery information. The battery is marked with this symbol, which may include lettering to indicate cadmium (Cd), lead (Pb), or mercury (Hg). For proper recycling, return the battery to your supplier or to a designated collection point. For more information see: www.recyclethis.info.
Industry Canada ICES-003 Compliance
This device meets the CAN ICES-003 (B)/NMB-003 (B) standards requirements.
Safety Instruction
The symbols that may be found in this document are defined as follows.
These instructions are intended to ensure that user can use the product correctly to avoid danger or property loss.
Laws and Regulations
- Use of the product must be in strict compliance with the local electrical safety regulations.
Transportation
- Keep the device in original or similar packaging while transporting it.
- Keep all wrappers after unpacking them for future use. In case of any failure occurred you need to return the device to the factory with the original wrapper. Transportation without the original wrapper may result in damage on the device and the company shall not take any responsibility.
- Do not drop the product or subject it to physical shock. Keep the device away from magnetic interference.
Power Supply
- The input voltage should meet the Limited Power Source (5 VDC, 2 A) according to the IEC61010-1 standard. Please refer to the technical specifications for detailed information.
- Make sure the plug is properly connected to the power socket.
- DO NOT connect multiple devices to one power adapter, to avoid over-heating or fire hazards caused by overload.
- Use the power adapter provided by a qualified manufacturer. Refer to the product specification for detailed power requirements.
Battery
- The built-in battery cannot be dismantled. Please contact the manufacture for repair if necessary. The battery may explode if it is replaced by an incorrect type. Replace with the same or equivalent type only. Dispose of used batteries in conformance with the instructions provided by the battery manufacturer.
- For long-term storage of the battery, make sure it is fully charged every half year to ensure the battery quality. Otherwise, damage may occur.
- Make sure the plug is properly connected to the power socket.
- When the device is powered off and the battery is full, the time settings can be kept for 60 days.
- The standard adapter power supply is 5 V.
- The battery is certified by UL2054.
Maintenance
- If the product does not work properly, please contact your dealer or the nearest service center. We shall not assume any responsibility for problems caused by unauthorized repair or maintenance.
- Wipe the device gently with a clean cloth and a small quantity of ethanol, if necessary.
- If the equipment is used in a manner not specified by the manufacturer, the protection provided by the device may be impaired.
- Your camera will periodically perform a self-calibration to optimize image quality and measurement accuracy. In this process, the image will pause briefly and you will hear a “click” as a shutter moves in front of the detector. The self-calibration will be more frequent during the startup or in very cold or hot environments.
This is a normal part of operation to ensure optimum performance for your camera.
Calibration Service
We recommend you send the device back for calibration once a year, and please contact the local dealer for the information on maintenance points. For more detailed calibration services, please visit https://www.hikmicrotech.com/en/support/calibrationservice.html.
Technical support
https://www.hikmicrotech.com/en/contact-us.html portal will help you as a HIKMICRO customer to get the most out of your HIKMICRO products. The portal gives you access to our support team, software and documentation, service contacts, etc.
Using Environment
- Make sure the running environment meets the requirements of the device. The operating temperature shall be -10 °C to 50 °C (14 °F to 122 °F), and humidity shall be 95% or less.
- Place the device in a dry and well-ventilated environment.
- DO NOT expose the device to high electromagnetic radiation or dusty environments.
- DO NOT aim the lens at the sun or any other bright light.
- When any laser equipment is in use, make sure that the device lens is not exposed to the laser beam, or it may burn out.
- The device is suitable for indoor and outdoor uses, but do not expose it in wet conditions.
- The level of protection is IP 54.
- The pollution degree is 2.
Emergency
If smoke, odor, or noise arises from the device, immediately turn off the power, unplug the power cable, and contact the service center.
Laser Light Supplement Warning
Warning : The laser radiation emitted from the device can cause eye injuries, burning of skin or inflammable substances. Prevent eyes from direct laser. Before enabling the Light Supplement function, make sure no human or inflammable substances are in front of the laser lens. The wave length is 650 nm, and the power is less than 1 mW. The laser meets the IEC60825-1:2014 standard.
Laser maintenance : It is not necessary to maintain the laser regularly. If the laser does not work, the laser assembly needs to be replaced in the factory under warranty. Keep the device power off when replacinglaser assembly. Caution-Use of controls or adjustments or performance of procedures other than those specified herein may result in hazardous radiation exposure.
Manufacture Address:
Room 313, Unit B, Building 2, 399 Danfeng Road, Xixing Subdistrict, Binjiang District, Hangzhou, Zhejiang 310052, China
Hangzhou Microimage Software Co., Ltd. COMPLIANCE NOTICE:
The thermal series products might be subject to export controls in various countries or regions, including without limitation, the United States, European Union, United Kingdom and/or other member countries of the Wassenaar Arrangement. Please consult your professional legal or compliance expert or local government authorities for any necessary export license requirements if you intend to transfer, export, re-export the thermal series products between different countries
Introduction
Packing List
Product Introduction
The handheld thermal camera is a camera with thermal and optical images. The built-in high-sensitivity IR detector and the high-performance sensor detect the temperature change and measure the real-time temperature. The handheld thermal camera is based on the thermal technology, specially designed for the needs of temperature measuring applications. People can quickly troubleshoot faults on-site.
Main Function
Temperature measurement
The device detects the real-time temperature and displays it on the screen.
Alarm
The device outputs audible and visual alarms when the target’s temperature is higher than the threshold value.
SuperIR
The device supports superior to increase the image quality.
Client Software Connection
PC : You can download HIKMICRO Analyzer
(https://www.hikmicrotech.com/en/industrialproducts/hikmicro-analyzer-
software.html) to analyze pictures offline professionally, and generate a
custom format report on your PC.
You can cast the real-time live view of the device to your PC through the UVC
alarm client.
Appearance
Dimensions
Components
Note
- The appearance and button functions vary according to different models.
- The optical lens is only supported by certain models. Please refer to the actual device or datasheet.
- The warning sign is beside the laser and on the left side of the device.
Warning:
The laser radiation emitted from the device can cause eye injuries, burning of skin or inflammable substances. Prevent eyes from direct laser. Before enabling the Light Supplement function, make sure no human or inflammable substances are in front of the laser lens. The wave length is 650 nm, and the power is less than 1 mW. The laser meets the IEC60825-1:2014 standard.
Preparation
Charge Device
- Lift the type-C interface cover.
- Connect the device to the power supply using the type-C cable to charge the device.
Note
The device is equipped with a built-in battery. For the first charge, charge the device for more than 3 hours when the device is turned on.
Power On/Off
Power On
Remove the lens cover, and hold for over six seconds to turn on the device. You can observe the target when the interface of the device is stable.
Power Off
When the device is on, hold for six seconds to power off the device.
Set Auto Power-off Duration
In the live view interface, press and go to More Settings → Auto Power-off to set the automatic shutdown time for device as required.
Live View
The live view interface of different models may vary. Take the actual product for reference.
Display Settings
Set Image Mode
You can set image modes of the device. Image Mode is only supported by certain
models.
Please refer to the actual device or the datasheet.
Steps:
1 Select an image mode by the following ways:
- Go to Settings → Image Settings → Image Mode, and select a preferred image mode.
- Press in live view to switch image modes.
Thermal : Display the thermal image only.
Fusion : Fuse the optical image with the thermal image. The fused image
with the clear edge is displayed in this mode.
Visual : Display the visual image only.
Optional: When selecting the fusion mode, you need to select the distance in Image Settings → Parallax Correction according to the distance to the target, so as to better overlap the thermal and optical images.
Press to save and exit.
Note
Your camera will periodically perform a self-calibration to optimize image quality and measurement accuracy. In this process, the image will pause briefly and you will hear a “click” as a shutter moves in front of the detector. The self-calibration will be more frequent during the startup or in very cold or hot environments. This is a normal part of operation to ensure optimum performance for your camera.
Set Palettes
The palettes allow you to select the desired colors. You can switch palettes by the following ways:
- Go to Settings → Palettes to select a preferred palette, and press to save and exit.
- Press in live view to switch palettes.
Set Level & Span
Set a display temperature range and the palette only works for targets within the temperature range.You can get better image contrast by adjusting the level & span parameters.
Steps:
- In the live view interface, press to show the menu.
- Press and select Level & Span.
- Select Setting Mode, and press to switch auto and manual adjustment.
- In Auto mode, the device adjusts display temperature range automatically.
- In Manual mode, select Parameters to enter the setting interface. Press to lock or unlock the max. temperature and min. temperature, and press to adjust the unlocked value. Or, unlock the max. temperature and min. temperature, and press to increase or decrease the individual
- values while remaining the same temperature range.
- Press to save and exit.
Display OSD Info
Go to Settings → Display Settings to enable the information on-screen display.
Parameters
Temperature measurement parameters such as emissivity and distance.
Brand Logo
The brand logo is a manufacturer logo displayed on the lower left corner of the screen. You can turn it off if not needed.
Temperature Measurement
The temperature measurement function provides the real-time temperature of the scene. The temperature information is displayed on the left top of your screen. The function is enabled by default.
Set Measurement Parameters
You can set temperature measurement parameters to improve the accuracy of temperature measurement.
Steps:
- In the live view interface, press to show the menu.
- Press to select desired parameters.
- Press to go to the settings interface.
- Press to save and exit.
- Emissivity : Enable Custom, and select Emissivity to set the emissivity of the target as the effectiveness in emitting energy as thermal radiation by pressing Or you can select a preset emissivity.
- Distance: Set the distance between the target and the device.
- Unit : Go to More Settings → Unit, and press to set the temperature unit.
- Temperature Range : Select a temperature range or select Auto Switch. The device can detect the temperature and switch the temperature range automatically in Auto Switchmode.
Set Image Measurement
The device measures the temperature of the whole scene and can be managed to display the center, hot, and cold spot in the scene.
Steps:
- In the live view interface, press to show the menu.
- Press to select Display Settings.
- Select the desired sports to show their temperatures, and press to enable them.
- Hot : Display the hot spot in the scene and show the max. temperature.
- Cold : Display the cold spot in the scene and show the min. temperature.
- Center : Display the center spot in the scene and show the center temperature.
- Press to save and exit.
Result:
The device shows the real-time temperature on the upper left side of live view interface.
Enhance High-Temperature Target
In the target enhancement function, when the target’s temperature is higher than the set value, the target will become red.
Steps:
- You can enable target enhancement function by the following ways:
- Go to Settings → Palettes, and select Above Alarm.
- Press in live view to switch the palette to Above Alarm.
- Go to Settings → Palettes → Temperature, and press / to configure the enhancement temperature threshold. When the temperature of the target is higher than the set value, the target will be red in live view.
- Press to save and exit.
Set Temperature Alarm
Set the alarm rules and the device will alarm when the temperature triggers the rule.
Steps:
- In the live view interface, press to show the menu.
- Press and select Alarm.
- Press to enable the function.
- Select Measurement to set the alarm rule. Select Alarm Threshold to set the threshold temperature. When the target temperature is higher or lower than the threshold value, the device will output an alarm.
- Press to save and exit.
Capture Snapshots
Capture One Image
You can capture snapshots in live view. The snapshot will be automatically saved in the albums.
Steps:
- In the live view interface, you can capture snapshots by the following ways.
- Press the trigger in live view to capture snapshots.
- Hold the trigger in live view to locate the target with laser light, and release the trigger to capture snapshots.
- Note
- Go to More Settings → Laser to turn on/off laser light.
- You cannot capture snapshots when the device is connected to PC.
- Optional : If the thermal images are exported and viewed on a high-resolution screen, enable SuperIR in the menu before capturing. The resolution of captured images with SuperIR is 4 times higher the original one.
- Optional : If a visual image is needed to be saved separately, enable Save Visual Image(only supported by the models with optical lens).
What to do next:
You can view and manage the snapshots in the album, and export them to PC.
View Snapshots
Steps:
- In the live view interface, press to show the menu.
- Press / to select Albums, and press to enter the album.
- Press to select the picture, and press to view it.
- Optional : Press to delete picture in picture view interface.
- Press to switch the picture.
- Press to exit.
Export Snapshots
Purpose:
Connect the device to your PC with Type-C cable, and then you can export the captured snapshots.
Steps:
- Lift the type-C interface cover.
- Connect the camera to your PC with Type-C cable and open the detected disk.
- Copy and paste the snapshots to PC and view the files.
- Disconnect the device from your PC.
Note
- For the first connection, the driver will be installed automatically.
- DO NOT disconnect the Type-C cable from PC during drive installation, or it may cause damage to the device.
Cast Screen
The device supports casting screen to PC by UVC protocol-based client software or player. You can connect the device to your PC via a type-C cable and cast the real-time live view of the device to your PC through the UVC client software.
Before You Start
- Connect the device and PC with the supplied Type-C cable.
- Download the UVC client software from and install the client on your PC. Refer to the user manual of the Client for detailed operation.
Steps:
- In the live view interface, press and go to More Settings → USB Cast Screen.
- Press to enable the function.
- Open the Client on your PC, and you can view the live view and operation of the device.
Maintenance
View Device Information
In the live view interface, press and go to More Settings → About to view the device information.
Set Time and Date
In the live view interface, press and go to More Settings → Time and Date to set the information.
Format Storage
Steps:
- In the live view interface, press and go to More Settings → Format Storage.
- Press and select OK to start formatting storage.
Note
Format storage before first use.
Upgrade
Before You Start:
Download the upgrade file from the official website first.
Steps:
- Connect the device to your PC with Type-C cable and open the detected disk.
- Copy the upgrade file and replace it to the root directory of the device.
- Disconnect the device from your PC.
- Reboot the device and then it will upgrade automatically. The upgrading process will be displayed in the main interface.
Note
After the upgrade, the device automatically reboots. You can view the current version in More Settings → About.
Restore Device
In the live view interface, press and go to More Settings → Restore Device to initialize the device and restore default settings.
Appendix
Common Material Emissivity Reference
Frequently Asked Questions (FAQ)
Q:The charge indicator flashes red.
A : Examine the items below.
- Examine whether the device is charged with the standard power adapter.
- Make sure the environment temperature is above 0°C (32°F).
Q:Capturing fails.
A : Examine the items below:
- Whether the device is connected to your PC and the capture function is unavailable.
- Whether the storage space is full.
- Whether the device is low-battery.
Q: The PC cannot identify the camera.
A : Examine whether the device is connected to your PC with a standard
Type-C cable.
Q: The camera cannot be operated or is not responding.
A: Hold to reboot the camera.
- Facebook : HIKMICRO Thermography
- LinkedIn : HIKMICRO
- Instagram: hikmicro_thermography
- YouTube : HIKMICRO Thermography
- E-mail : support@hikmicrotech.com
- Website : www.hikmicrotech.com
References
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>