SEALEY 9329 3 Fold Flat Mask Instruction Manual
- June 4, 2024
- SEALEY
Table of Contents
3 Fold Flat Mask
Instruction Manual
9329 3 Fold Flat Mask
DISPOSABLE FACE MASKS
MODEL NO’S: 9329/3 & /10 (PACKS OF 3 & 10), 9309/3 & /10 9331/3 & /10,
9304/3 & /10, 9305/3 & /10, 9332/3 & /10, 9333/3 & /10 9334/3 & /10.
Thank you for purchasing a Sealey product. Manufactured to a high standard,
this product will, if used according to these instructions, and properly
maintained, give you years of trouble-free performance.
IMPORTANT: PLEASE READ THESE INSTRUCTIONS CAREFULLY. NOTE THE SAFE
OPERATIONAL REQUIREMENTS, WARNINGS & CAUTIONS. USE THE PRODUCT CORRECTLY AND
WITH CARE FOR THE PURPOSE FOR WHICH IT IS INTENDED. FAILURE TO DO SO MAY CAUSE
DAMAGE AND/OR PERSONAL INJURY AND WILL INVALIDATE THE WARRANTY. KEEP THESE
INSTRUCTIONS SAFE FOR FUTURE USE.
**** Refer to the instruction manual
SAFETY
** A properly selected face mask is essential to protect your health.
Before commencing any task, please consult with qualified safety personnel to
ensure that the face mask type and rating offer adequate protection for your
intended use.
× DO NOT use for fire fighting. These respirators DO NOT supply oxygen.
DO NOT use in oxygen-deficient atmospheres e.g. tanks or other poorly
ventilated areas (see Limitations to use section).
× DO NOT use in explosive atmospheres.
** For use only by trained and qualified personnel. Requirements for leak
tightness are unlikely to be achieved if the respirator is worn against a
beard or facial stubble.
**** When transporting this product, retain in the original packaging and
keep it away from mechanical and chemical hazards.
INTRODUCTION
Pack of disposable masks classes FFP1/2/3 NR (see individual packaging). Protects against non-toxic dust and water-based aerosols. Filter Efficiency ≥ 80%. Manufactured to BS EN 149:2001 + A1:2009. PLEASE REFER TO THE APPLICATIONS TABLE OVERLEAF.
Model no. | FFP classification |
---|---|
9329 | FFP1 NR |
9309 | FFP1 NR |
9331 | FFP1 NR |
9304 | FFP2 NR |
9305 | FFP2 NR |
9332 | FFP2 NR |
9333 | FFP3 NR |
9334 | FFP3 NR |
DIRECTIONS FOR USE
3.1. Fit the respirator and check leak tightness BEFORE entering the
contaminated area.
3.2. Wear the respirator for the whole duration of the exposure to
contaminants.
3.3. Use the respirator in accordance with applicable Health and Safety
Regulations.
3.4. Discard the respirator and replace it with a new one if:
– the respirator is removed while in a contaminated area.
– excessive clogging of the respirator causes breathing difficulty or
discomfort.
– the respirator becomes damaged.
– (for respirators protecting against vapors; discard if the smell of vapors
present becomes detectable).
3.5. Leave the contaminated area if dizziness, irritation or other distress
occurs.
3.6. Only for single use. No maintenance is necessary. DO NOT store and/or
reuse after a single use.
3.7. Discard the respirator after a single use (one shift maximum).
FITTING INSTRUCTIONS
4.1. Cup the respirator in the hand, allowing the headbands to hang freely.
4.2. Hold the respirator under the chin with the nosepiece facing outwards.
4.3. Place the lower headband around the neck below the ears. Holding the
respirator against the face with one hand, place the top headband above the
ears, around the crown of the head.
4.4. Respirators with adjustable headbands only: while maintaining the
position of the respirator, adjust the tension by pulling tab of each
headband. (Tension may be decreased by pushing out on the back of the buckle).
4.5. Mould the nose area to the shape of the face, running the fingertips of
both hands from the top of the nose piece down both sides whilst pressing
inwards.
4.6. CHECK FOR LEAK TIGHTNESS AS FOLLOWS:
– Place both hands over the respirator and exhale sharply, positive pressure
should be inside the respirator. If air is felt escaping around the edges
readjust the respirator by tightening the nose piece and/or increasing the
tension of the headbands. – Repeat the procedure until a satisfactory face fit
has been achieved.
IMPORTANT In the case of respirators with nonadjustable headbands if the
headbands are too loose tension can be increased by tying a small knot in the
headband.
STORAGE
5.1. Keep unused respirators in their closed box and store and transport in a
dry, non-contaminated area between -20 +50°C at a relative humidity below 75%.
EXPIRY DATE
6.1. The period of obsolescence is 3 years from the date of manufacture (refer
to manufacturing and expiry date on the packaging.
LIMITATIONS TO USE
× DO NOT use these respirators or enter/stay in an area where:
– oxygen concentration is less than 19%. – contaminants or their
concentrations are immediately dangerous to life or health.
– particulate concentrations exceed levels fixed by applicable health and
safety regulations or protection factor x NPF whichever is lower (Nominal
protection factors 4.5 for FFP1, 12.5 for FFP2, and 50 for FFP3).
APPLICATIONS TABLE
Dust mask grade | FFP1 | FFP2 | FFP3 |
---|---|---|---|
Protection: | Non-toxic dust and/or water-based aerosols. Minor dust | ||
level. | Mild toxic or irritant, solid & liquid aerosols. Moderate dust level. |
Toxic liquids, solids & liquid aerosols. High dust level.
Application:| Handling rubble, sweeping, and drilling concrete.|
Plastering, sanding rust & softwood, grinding & cutting metal, paint spraying
(excluding 2-pack isocyanate)| Paint stripping, sanding of hardwood or
cement, copper, hrome or arsenic, welding.
Substance:| Flour, chalk, graphite, cotton, and concrete.| Untreated
softwood, coal, powder pesticide, fiberglass.| Biological, pharmaceutical,
chrome, lime, lead, asbestos (non-handling).
Filter efficiency :| ≥80%| ≥94%| ≥99%
- The application guide is given as an indication only. Before commencing with any task, please consult with qualified safety personnel, or carry out your own risk assessment, to ensure that the face mask type and rating offer adequate protection for your intended use. You may need to use this mask in conjunction with other safety equipment. These are particulate filters only, and do not provide protection from harmful fumes or gases.
ENVIRONMENT PROTECTION
Recycle unwanted materials instead of disposing of them as waste. All
tools, accessories, and packaging should be sorted, taken to a recycling
center, and disposed of in a manner that is compatible with the environment.
When the product becomes completely unserviceable and requires disposal, drain
any fluids (if applicable) into approved containers and dispose of the product
and fluids according to local regulations.
Note: It is our policy to continually improve products and as such we
reserve the right to alter data, specifications, and component parts without
prior notice.
Important: No Liability is accepted for incorrect use of this product.
Warranty: The guarantee is 12 months from the purchase date, proof of
which is required for any claim.
Sealey Group, Kempson Way, Suffolk Business Park,
Bury St Edmunds, Suffolk. IP32 7AR
**** 01284 757500
01284 703534
sales@sealey.co.uk
www.sealey.co.uk
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>