USER INSTRUCTIONS
LCD-W110
Loop Powered indicator
with backlight for field mounting
LCD-W110 Loop Powered Indicator With Backlight
The user instruction must be read prior to adjustment and/or installation. All information subject to change without notice.
INTRODUCTION
LCD-W110 is a loop powered digital indicator to be connected directly in a
4-20 mA loop without need for external power supply.
The indicator show numeric values in the range from -1999 to 9999 proportional
to the 4-20 mA input signal on a digital display.
LCD-W110 is designed for field mounting on wall, pipe or DIN rail and has a
rugged and splashproof housing for mounting directly into an industrial
environment.
GENERAL INFORMATION
Configuration of the indicator is done either with NFC and the smartphone app
INOR Connect or with three push buttons.
The indicator can be connected to the 4-20 mA loop of any normal 2-wire
transmitter. The field indicator LCD-W110 can be equipped with an integrated
Inorb In Head transmitter of any type for direct sensor input.
LCD-W110 is equipped with a rugged and splashproof IP 65 / NEMA 4X housing
with double cable conduits for convenient installation, one blanking plug is
included.
The indicator is designed for ambient temperatures between -20 to +70 °C (-4
to +158 °F).
This manual describes in short form the various functions and technical data
of the display, for a more detailed description please refer to the specific
manual for the display module LCD-D100.
Installation, assembly, start-up and maintenance may only be performed by
appropriately trained personnel.
MOUNTING
Wall Mounted
Distance between wall mounting holes
Pipe Mounted
Mounting accessory p/n 70ADA00021
- LCD-W110
- Mounting plate
- Hose clamp
- Screws
- Locking washer
- Nuts
DIN Rail Mounted
Mounting accessory p/n 70ADA00022
- LCD-W110
- Mounting plate
- Clip
- Screws
- Locking washer
- Nuts
Inside minting of 2-wire Transmitter
Mounting accessory p/n 70ADA00024
- LCD-W110
- Mounting plate
- Screws
- Springs
- Lock washers
- In-head transmitter (not included)
DATA (short form)
Input Current | 4-20 mA |
---|---|
I Maximum current | 30 mA |
Minimum current for operation | ,u3.5 mA |
Voltage drop | 4.2 V |
Indication
Display| 7-segment black LCD with clear background
Backlight| White LED powered from the 4-20 mA loop
Indication range| 4 digits (-1999 to 9999)
Digit height| 17.8 mm / 0.7″
Decimals| Selectable, 0 to 3
Under range / Over range| Flashing symbols Lo (I 5 3.6 mA) /
| HI (I ? 21.0 mA)
Engineering units| Set of self-adhesive labels included for units: °C, °F, mA,
mV, V, bar, mbar, Pa, kPa, MPa, pH, %, s, ms, Ns, mm, an, m
Response time| Appr. 1 s
Power on delay: 5 s and stable after 1 min
Temperature influence| 5 ±0.01 % FS / °C
Configuration method| 3 push buttons or NFC, located on the rear of the
display
Operation temperature| -20 to +70 °C / -4 to +158 °F
Typical accuracy| ±0.05% of span ±1 digit
Dimensions| 80 x 110 x 65 mm / 3.15 x 4.33 x 2.56″
Protection| 11637 NEMA 4X
Connections| Push-In spring connection, Wire cross section 0.25 mm2-1.5 mm=
AWG 24-16
Cable entries| 2x cable glands M20x1.5 for cable diameter 5-13 mm (0.20-0.511
(lx blanking plug Included)
NAMUR NE 43 compliance| Yes
HART transparent| Yes
Mounting| Wall, 35 mm DIN rail acc. to EN 60715 or 50-65 mm (2-2.55″) pipe
with mounting kit
DESIGN
2x M20x1.5 cable glands, Cable Ø 5-13 mm/0.20-0.51”
If a cable gland is not used, then it must be removed and the entry sealed
with the included M20 blanking plug.
Materials:
Base and lid: | Polycarbonate |
---|---|
Gasket: | Polyurethane |
Cover screws: | Polyamide |
Blanking plug: | Polyamide |
Top label: | Polycarbonate |
ORDERING INFORMATION
Product | Part No. |
---|---|
Indicator LCD-W110 | 70LCDW1102 |
Pipe mounting kit | 70ADA00021 |
DIN-rail mounting kit | 70ADA00022 |
Built-in transmitter mounting kit | 70ADA00024 |
Indicator LCD-W110 can be ordered with a built-in INOR In-Head transmitter of
any type and configured according to customer’s specification.
CONNECTIONS
Connections 2 and 3 are internally shorted
Connection method
Terminal block with Push-In spring connection
Connection capacity
Conductor cross section, flexible| 0.2 mm2 … 1.5 mm2
Conductor cross section flexible, with ferrule without plastic sleeve| 0.25
mm2 … 0.75 mm2
Conductor cross section flexible, with ferrule with plastic sleeve| 0.25 mm2 …
0.75 mm2
i Stripping length| 8 mm
J Conductor cross section AWG| 24 … 16
CONFIGURATION – VIA PUSH BUTTONS
CONFIGURATION – VIA PUSH BUTTONS
1. Pushbutton with step (decrease) function
2. Pushbutton with enter function
3. Pushbutton with step (increase) function| 1. Parameter name
2. Factory default value
3. The default setting value refers to display TAG / ID is the last four
digits in the serial number.
---|---
Parameter description:
- Engineering value related to the lower point (4 mA), the default setting value refers to 0.0 at lower point.
- Engineering value related to the higher point (20 mA), the default setting value refers to 100.0 at higher point.
- Decimal point location, the default setting value refers to 1 decimal.
- Filter, the default setting value refers to “No filter”.
- TAG / ID number, the default setting value refers to the last four digits in the serial number for the display.
- Display update interval, the default setting value refers to update display immediately.
- Backlight mode, the default setting value refers to the backlight on but flashing during alarm.
- NFC mode, the default setting value refers to the configuration via NFC is on.
- Error correction, the default setting refers to no error correction.
- Reset back to factory default.
- End setup and return to indication.
CONFIGURATION – VIA APP
Before making a configuration of LCD-W110 you need to do following:
- Make sure that you have a mobile device with NFC communication activated
- Download the app INOR Connect to your mobile device
Required versions:
iOS
iOS 13 or later and IPhone 7 or later for NFC| Android
Android 4.4 or later
---|---
Scan the QR code to download and install INOR Connect
Configuration procedure:
-
Launch the app by clicking on the App icon or holding your mobile device against the display on the part of the device where NFC is located (only possible with Android).
-
Click on
“Read Configuration” and hold your mobile device against the display as explained in the first section. -
In the app you can edit the following:
• Display indication range
• Decimal points position
• Backlight mode
• Filter settings
• TAG-no -
Once you have set the desired values in the app, you transfer it to the display by clicking the transfer button and holding the mobile device against the display until a green check box appears confirming that the transfer has been completed.
DIMENSIONS
DISPLAY FUNCTION, NAMUR NE 43
Input current (mA) | Signal description | Indication on LCD-W110 |
---|---|---|
? 21,0 mA | Failure | Flashing HI |
20,5 to <21,0 mA | – | Fixed value (max. range value +3.1 0/0) |
20,0 to 20,5 mA | Over range | Extended indication range |
4,0 to 20,0 mA | Normal operating range | The configured indication range |
3,8 to 4,0 mA | Under range | Extended indication range |
>3,6 to 3,8 mA | – | Fixed value (min. range value -1.25 %) |
s 3,6 mA | Failure | Flashing Lo |
LIMITED WARRANTY
INOR Process AB, or any other affiliated company within the Inor Group
(hereinafter jointly referred to as ”Inor”), hereby warrants that the Product
will be free from defects in materials or workmanship for a period of five (5)
years from he date of delivery (”Limited Warranty”). This Limited Warranty is
limited to repair or replacement at Infor’s option and is effective only for
the first end-user of the Product. Upon receipt of a warranty claim, Inorb
shall respond within a
reasonable time period as to its decision concerning:
- Whether Inor acknowledges its responsibility for any asserted defect in materials or workmanship; and, if so,
- the appropriate cause of action to be taken (i.e. whether a defective product should be replaced or repaired by Inor).
This Limited Warranty applies only if the Product:
- is installed according to the instructions furnished by Inor;
- is connected to a proper power supply;
- is not misused or abused; and
- there is no evidence of tampering, mishandling, neglect, accidental damage, modification or repair without the approval of Inor or damage done to the Product by anyone other than Inor.
This Limited Warranty is provided by Inor and contains the only express
warranty provided.
INOR SPECIFICALLY DISCLAIMS ANY EXPRESS WARRANTY NOT PROVIDED HEREIN AND ANY
IMPLIED WARRANTY, GUARANTEE OR REPRESENTATION AS TO SUITABILITY FOR ANY
PARTICULAR PURPOSE, PERFORMANCE, QUALITY AND ABSENCE OF ANY HIDDEN DEFECTS,
AND ANY REMEDY FOR BREACH OF CONTRACT, WHICH BUT FOR THIS PROVISION, MIGHT
ARISE BY IMPLICATION, OPERATION OF LAW, CUSTOM OF TRADE OR COURSE OF DEALING,
INCLUDING IMPLIED WARRANTIES OF MER-CHANTABILITY AND FITNESS FOR A PARTICULAR
PURPOSE. EXCEPT AS PROVIDED HEREIN, INOR FURTHER DISCLAIMS ANY RESPONSIBILITY
FOR LOSSES, EXPENSES, INCONVENIENCES, SPECIAL, DIRECT, SECONDARY OR
CONSEQUENTIAL DAMAGES ARISING FROM OWNERSHIP OR USE OF THE PRODUCT.
Products that are covered by the Limited Warranty will either be repaired or
replaced at the option of Inor. Customer pays freight to Inor, and Inor will
pay the return freight by post or other “normal” way of transport. If any
other type of return freight is requested, customer pays the whole return
cost.
INOR Process AB, PO Box 9125, SE-200 39 Malmö, Sweden,
Phone: +46 40 312 560, Fax: +46 40 312 570, E-mail:
support@inor.se
INOR Transmitter OY, Unakite 13, FI-01300 Vantaa, Finland,
Phone:+358 10 421 7900, Fax: +358 10 421 7901, E-mail:
myynti@inor.fi
INOR Transmitter GmbH, Am See 24, D-47279 Duisburg, Germany,
Phone: +49-203 7382 762 0, Fax: +49-203 7382 762 2, E-mail: info@inor-
gmbh.de
KROHNE Temperature Division INOR, 55 Cherry Hill Drive,
Beverly, MA 01915, United States
Phone: +1 978 826 6900, Fax: +1 978 535 1720, E-mail: inor-
info@krohne.com
www.inor.com, www.krohne-inor.se
www.krohne-inor.fi, www.inor-gmbh.de
This product should not be mixed with other kind of scrap, after usage.
It should be handled as an electronic/electric device.
© INOR 02/2024 – 4010240701 – MA LCD-W110 R01 en
References
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>