Product Information

Specifications

  • Model No.: 120-K
  • Version: S9k

Product Glance

Value Min Typ Max
SHA256/BTC/BCH 13.50 1148 85.00
1389 12.00

Detailed Characteristics

Hardware Configuration| Quantity of hash chips| Quantity of hash boards| Networking connection mode
---|---|---|---
Value| 85.00 – 90.07 – 1148 – 11.60 – 1250| 13.50 – 12.00 – 95.7 – 1389 – 13.95 – 90.95 – 96.37 – 1344 –
13.00 – 115.9 – 180| 3 RJ45 ethernet 10/100M
Server Size (LengthWidthHeight, w/o package), mm(2-1)| 298.0129.6187.5/321.3129.6200.0| 3.95/4.50
Environment Requirements| 0 – 40| 25 – 40 – 25 – 85
Operation humidity, RH| 5% – 95%
Notes:| (1-1) Refers to PSU power conversion efficiency of 93%. (1-2)
Refers to PSU power conversion efficiency of 93%. (1-3) Min condition:
25, minJ/TH, typical hash rate.

Product Usage Instructions

S9k Server Components
The main components and controller front panel of the S9k server are shown in the figure provided in the manual.

Connecting to the Power Supply

  1. Remove the screw at the position indicated by A with a cross screwdriver.
  2. Lift the upper cover of the control board upward at the direction indicated by the arrow shown in the figure and then pull it in the upper rear direction.

Frequently Asked Questions (FAQ)

  • Q: Do I need to purchase a separate power supply for the S9k Server?
    A: Yes, you must provide your own ATX power supply for the S9k Server.

© Copyright Bitmain Technologies Holding Company 2007 – 2022. All rights reserved. Bitmain Cayman (hereinafter referred to as ‘Bitmain’) reserves the right to make corrections, modifications, enhancements, improvements, and other changes to its products and services at any time and to discontinue any product or service without notice. Customers should obtain the latest relevant information before placing orders and should verify that such information is current and complete. All products are sold subject to Bitmain’s terms and conditions of sale supplied at the time of order acknowledgment.

Bitmain warrants the performance of its products to the specifications applicable at the time of sale by Bitmain’s standard warranty. Testing and other quality control techniques are used to the extent Bitmain deems necessary to support this warranty. Except where mandated by government requirements, testing of all parameters of each product is not necessarily performed.

Bitmain assumes no liability for third‐party application assistance. Customers are responsible for their products and applications using Bitmain components. To minimize the risks associated with customer products and applications, customers should provide adequate design and operating safeguards. Bitmain does not warrant or represent that any license, either express or implied, is granted under any Bitmain patent right, copyright or other Bitmain intellectual property right relating to any combination, machine, or process in which Bitmain products or services are used. Information published by Bitmain regarding third‐party products or services does not constitute a license from Bitmain to use such products or services or a warranty or endorsement thereof. Use of such information may require a license from a third party under the patents or other intellectual property of the third party, or a license from Bitmain under the patents or other intellectual property of Bitmain.

Resale of Bitmain products or services with statements different from or beyond the parameters stated by Bitmain for that product or service voids all express and any implied warranties for the associated Bitmain product or service and is an unfair and deceptive business practice. Bitmain is not responsible or liable for any such statements.

All company and brand products and service names are trademarks or registered trademarks of their respective holders. All text and figures included in this publication are the exclusive property of Bitmain, and may not be copied, reproduced, or used in any way without the express written permission of Bitmain. Information in this document is subject to change without notice and does not represent a commitment on the part of Bitmain. Although the information in this document has been carefully reviewed, Bitmain does not warrant it to be free of errors or omissions. Bitmain reserves the right to make corrections, updates, revisions or changes to the information in this document.

Bitmain

Overview

The S9k server is Bitmain’s newest version in the S9k server series. All S9k servers are tested and configured before shipping to ensure easy set-up.

BITMAIN-S9k-Server-fig-1

  1. You must provide your own ATX power supply.
  2. Please refer to the layout above to place your goods in usage in case of any damage.
Components

The main components and controller front panel of the S9k server are shown in the following figure:

BITMAIN-S9k-Server-fig-2

Connecting to the Power Supply
  1. Remove the screw at the position indicated by A with a cross screwdriver.
  2. Lift the upper cover of the control board upward at the direction indicated by the arrow shown in the figure and then pull it in the upper rear direction.
  3. The position and name of the socket are shown in the figure below after removing the upper cover of the control board.
    No.| Item| Quantity
    ---|---|---
    1| Fan Socket| 2
    2| Main Control PSU Socket| 1
    3| Hashboard Signal Socket| 3
    4| Hashboard PSU Socket| 9
    5| Main Control Board PSU Socket| 4
  4. Connecting the external power supply to the corresponding socket of the server and then bind the cables at the position indicated by B.
  5. Put the upper cover of the control board back in place and fix the screw at the position indicated by A. Note that the bundled cables shall be placed into the U‐shaped hole.

Warning: Energy Hazards!

  • Please be sure to follow the manual for installation.
  • Risk of injury due to energy hazard exists inside.
  • Be sure to close the metal cover before powering on the equipment, otherwise there is a risk of injury.
  • Be sure to use an external power supply which was approved according to IEC 60950‐1:2005 + A1 + A2 or IEC 62368‐1:2014. The external power supply shall provide SELV output and be evaluated.

Specifications

  • Model No.: 120‐K
  • Version: S9k
Product Glance Value
Crypto Algorithm/Coins SHA256/BTC/BCH
Hashrate, TH/s 13.50
Reference power on the wall, Watt 1148
Reference power efficiency on wall @ 25 ° C , J/TH 85.00
Adapted AC/DC output requirement, Watt / Volt 1389/12.00
Detailed Characteristics Value
--- ---
Min Typ

Hashrate & Power
Hashrate, TH/s|  | 13.50| 13.95
Power efficiency on wall @ 25 ° C , J/TH (1‐1)| 85.00| | 90.95
Power efficiency on wall @ 40 ° C , J/TH (1‐2)| 90.07| | 96.37
Reference power on the wall, Watt (1‐3)| 1148|  | 1344
DC input voltage range, Volt (1‐4)| 11.60| 12.00| 13.00
DC input current range, Amp (1‐5)|  | 95.7| 115.9
Adapted AC/DC output power requirement, Watt (1‐6)| 1250| 1389|
Hardware Configuration
Quantity of hash chips| 180
Quantity of hash boards| 3
Networking connection mode| RJ45 ethernet 10/100M
Server Size (LengthWidthHeight, w/o package), mm (2‐1)| 298.0129.6187.5/321.3129.6200.0
Net weight, kg (2‐2)| 3.95/4.50
Noise, dBA @25 ° C (2‐3)|  |  | 76
Environment Requirements
Operation temperature, ° C| 0| 25| 40
Storage temperature, ° C| ‐40| 25| 85
Operation humidity, RH| 5%|  | 95%
---|---|---|---

Notes:

  • (1‐1) Refers to PSU power conversion efficiency of 93%.

  • (1‐2) Refers to PSU power conversion efficiency of 93%.

  • (1‐3) Min condition: 25℃, minJ/TH, typical hash rate.

    • Max condition: 40℃, max J/TH, max hash rate.
    • Refers to PSU power conversion efficiency of 93%.
  • (1‐4) Caution: Wrong input voltage may probably cause server damage.

  • (1‐5) Typ condition: min reference power, typical DC input voltage.

    • Max condition: max reference power, min DC input voltage.
  • (1‐6) Min condition: 40℃, max J/TH, max hash rate, PSU output power should be no less than the min value to make sure mining is stable.
    Typical condition: (typical power) = (min power)/90%, leave power output margin for PSU.
    Caution: It is strongly recommended that using typical power can make sure your server works well. You can use one PSU to power multiple boards. Do not attempt to power one board with more than one PSU. All PCI‐E ports are required to plug in while powering up the board.

  • (2‐1) Domestic and international versions.

  • (2‐2) Domestic and international versions.

  • (2‐3) Max condition: Fan is under max RPM(rotation per minute).

Setting Up the Server

To set up the server:
The file IPReporter.zip is supported by Microsoft Windows only.

  1. Go to the following site: https://shop.bitmain.com/support/download.
  2. Choose ‘Others’ and download the following file: IPReporter.zip.
  3. Extract the file.
    • The default DHCP network protocol distributes IP addresses automatically.
  4. Right‐click IPReporter.exe and run it as Administrator.
  5. Select one of the following options:
    • Shelf, Step, Position – suitable for farm servers to mark the location of the servers.
    • Default – suitable for home servers.
  6. Click Start.BITMAIN-S9k-Server-fig-8
  7. On the controller board, click the IP Report button. Hold it down until it beeps (about 5 seconds).BITMAIN-S9k-Server-fig-9
  8. In your web browser, enter the IP address provided.
  9. Proceed to login using root for both the username and password.
  10. In the Network section, you can assign a DHCP IP address (optional).
  11. Click Save & Apply.BITMAIN-S9k-Server-fig-10

Configuring the Server

Setting Up the Pool

To configure the server:

  1. click General Settings.BITMAIN-S9k-Server-fig-11
  2. Set the options according to the following table:

Option

|

Description

---|---
Pool URL| Enter the URL of your desired pool.

The S9k server can be set up with three mining pools, with decreasing priority from the first pool (pool 1) to the third pool (pool 3).

The pools with low priority will only be used if all higher-priority pools are offline.

Worker| Your worker ID on the selected pool.
Password| The password for your selected worker.
3. Click Save & Apply to save and restart the server.

Monitoring Your Server

To check the operating status of your server:

  1. Click the status marked below.
    Here is an example of an S9k‐13.5T server:BITMAIN-S9k-Server-
fig-12 Note: The S9k server is with automatic frequency. Firmware will stop running when the Temp(PCB) reaches 85℃ or the Temp(Chips) reaches 105℃, there will be an error message “Fatal Error: Temperature is too high!” shown at the bottom of the kernel log page.

  2. Monitor your server according to the descriptions in the following table:

Option Description
ASIC# Number of chips detected in the chain.
Frequency ASIC frequency setting.
GH/S(RT) The hash rate of each hash board (GH/s).
Temp(PCB) The temperature of each hash board (°C). (Applied only to servers

with fixed frequency).
Temp(Chip)| The temperature of the chips on each hash board (°C).
ASIC status| One of the following statuses will appear:

●       O ‐ indicates OK

●       X ‐ indicates an error

●       ‐ indicates dead

Administering Your Server

Checking Your Firmware Version

To check your firmware version:

  1. In System, click the Overview tab.
  2. File System Version displays the date of the firmware your server uses. In the example below, the server is using firmware version 20190616.BITMAIN-S9k-Server-fig-13
Upgrading Your System

Make sure that the S9k server remains powered during the upgrade process. If power fails before the upgrade is completed, you will need to return it to Bitmain for repair.

To upgrade the server’s firmware:

  1. In System, click Upgrade.BITMAIN-S9k-Server-fig-14
  2. For Keep Settings:
    • Select the check box to keep your current settings (default).
    • Clear the check box to reset the server to default settings.
  3. Click the (Browse) button and navigate to the upgrade file. Select the upgrade file, then click Flash Image. A message appears notifying you if the S9k firmware can be upgraded and if yes, will then proceed to flash the image.
  4. When the upgrade is completed, the following message appears:BITMAIN-S9k-Server-fig-15
  5. Click one of the following options:
    • Reboot ‐ to restart the server with the new firmware.
    • Go Back ‐ to continue mining with the current firmware. The server will load the new firmware next time when it is restarted.
Modifying Your Password

To change your login password:

  1. In the System, click the Administration tab.
  2. Set your new password, then click Save & Apply.BITMAIN-S9k-Server-fig-16
Restoring Initial Settings

To restore your initial settings

  1. Turn on the server and let it run for 5 minutes.
  2. On the controller front panel, press and hold the Reset button for 10 seconds.

Resetting your server will reboot it and restore its default settings. The red LED will automatically flash once every 15 seconds if the reset is operated successfully.

Environmental Requirements
Please run your server by the following requirements

Basic Environmental Requirements:

Climatic Conditions:

Description Requirement
Operating Temperature 0‐40˚C
Operating Humidity 10‐90%RH (non‐condensing)
Storage Temperature ‐20‐70℃
Storage Humidity 5‐95%RH(non‐condensing)
Altitude <2000m

Site Requirements of the Server Running Room:

  • Please keep the server running room away from industrial pollution sources:
  • For heavy pollution sources such as smelters and coal mines, the distance should be more than 5km.
  • For moderate pollution sources such as chemical industries, rubber and electroplating industries, the distance should be more than 3.7km.
  • For light pollution sources such as food factories and leather processing factories, the distance should be more than 2km.
  • If unavoidable, the site should be chosen in the perennial upwind direction of the pollution source.
  • Please do not set your location within 3.7km from the seaside or the salt lake. If unavoidable, it should be built as airtight as possible, and equipped with air conditioning for cooling.

Electromagnetic Environmental Conditions:
Please keep your site away from transformers, high‐voltage cables, transmission lines and high‐current equipment, for example, there should be no high‐power AC transformers (>10KA) within 20 meters, and no high‐voltage power lines within 50 meters. Please keep your site away from high‐power radio transmitters, for example, there should be no high‐power radio transmitters (>1500W) within 100 meters.

Other Environmental Requirements:
The server running room shall be free of explosive, conductive, magnetically conductive and corrosive dust. The requirements of mechanical active substances are shown below:

Requirements of Mechanical Active Substances

Mechanical Active Substance Requirement
Sand <= 30mg/m3
Dust (suspended) <= 0.2mg/m3
Dust (deposited) <=1.5mg/m2h

Requirements of Corrosive Gas

Corrosive Gas Unit Concentration
H2S ppb < 3
SO2 ppb < 10
Cl2 ppb < 1
NO2 ppb < 50
HF ppb < 1
NH3 ppb < 500
O3 ppb < 2

Note: ppb (part per billion) refers to the unit of concentration, and 1 ppb stands for the volume ratio of part per billion.

Regulations

FCC Notice (FOR FCC CERTIFIED MODELS):
This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation.

Note:
This equipment has been tested and found to comply with the limits for a Class A digital device, under part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used per the instruction manual, may cause harmful interference to radio communications. Operation of this equipment in a residential area is likely to cause harmful interference in which case the user will be required to correct the interference at his own expense.

EU WEEE: Disposal of Waste Equipment by Users in Private Households in the European Union
This symbol on the product or its packaging indicates that this product must not be disposed of with your other household waste. Instead, it is your responsibility to dispose of your waste equipment by handing it over to a designated collection point for the recycling of waste electrical and electronic equipment. The separate collection and recycling of your waste equipment at the time of disposal will help to conserve natural resources and ensure that it is recycled in a manner that protects human health and the environment. For more information about where you can drop off your waste equipment for recycling, please contact your local city office, your household waste disposal service or the shop where you purchased the product.

References

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>

Related Manuals