WINE GUARDIAN SPLIT Series Packaged Cooling Systems Installation Guide
Wine Guardian PRO SERIES SPLIT System Quick Start Installation Guide Specialty Residential and Commercial Cooling System Quick Start Installation Guide.
This document is a pictorial guide on in- stalling the SPLIT Pro Series
Cooling System. It is not intended to replace the detailed in- structions
found in the SPLIT System Instal- lation, Operation and Maintenance (IOM)
manual, which includes important safety mes- sages. All SPLIT Series
installers and owners should carefully follow for safe and optimal performance
of the system. A copy of the manual may be viewed and downloaded at
https://wineguardian.com/support-wine-cellar- consultation/installation-operation-
maintenance-
manuals/
Refer to the Installation and Operations man- ual for installation
instructions related to duct collars and duct collar kits, optional remote
interface control and remote sensors.
If you have any additional questions related to the installation, operation or
maintenance of your SPLIT system, please contact your authorized Pro Series
distributor or Wine Guardian Service Department.
_ _Fan Coil__
Optional Equipment
Humidification—Integral or Stand-alone
Ideal for adding humidity to your wine cellar.
Electric Heat Option
Required when the temperature in the rooms surrounding the wine cellar may drop below 50°F (10°C) for an extended period of time. Factory installed
Xtreme Low Ambient Option
The Xtreme low ambient cold temperature package is recommend- ed for areas where the temperature consistently dips below 20°F and maintains operation of the Wine Guardian condensing unit to – 20°F.
- Unpackage
- Remove unit from box. Check for any signs of concealed damage, and that all optional equipment has been provid- Contact Wine Guardian immediately if components are missing or unit has been damaged in shipping.
- Shipment includes:
- One (1) fan-coil unit
- One (1) condensing unit
- One (1) 7’ clear plastic drain hose
Installation—Mounting Locations
Wine Guardian’s Split Pro system fan coil units are typically installed
indoors located near the room to minimize the length of ductwork to and from
the wine room. Provide a
three-foot clearance around the unit for removal of duct- work, or access for
unit maintenance. The fan coil unit can be located either above, or below the
condensing unit in height keeping any height difference to a minimum
-
*
_ _Floor Mounting__
- Mount the Wine Guardian fan coil on a plywood surface at least 12 inches above the floor to keep __ it away from water. Allow adequate space for the external drain
Wall Mounting
A. Provide adequate support on both ends of the unit to accommodate the weight of the system. Angle brackets are available as an option for these types of applications
Ceiling Mounting
A. Construct a structurally sound, level platform to place the unit on when hanging it from the ceiling joists. The SPLIT system is NOT designed to be suspended from the top of the unit; it must be supported from the bottom.
Wiring Thermostat
A. Thermostat and control wire are not included with
Wine Guardian Pro unit.
Note: Wine Guardian Pro requires the use of a 24 volt thermostat. Thermostat
and control wire shall be by others.
B. Disconnect control wire from unit and thermostat. Route the control wire to
the desired thermostat location within the wine room.
C. Follow thermostat manufacturer’s instructions for mounting thermostat,
making sure to re-connect the control wire to the device.
D. Re-connect the control wire at the Wine Guardian 24 volt terminal strip at
the appropriate connection points. (see photo on left)
Condensate Drain
A. PRO SERIES Split systems are supplied with 7 feet 2 meters) of ½” (13 mm)
inside dimension clear tube.
B. Slip plastic hose into drain port connection at unit and route to nearest
open floor drain, sink or condensate pump. A hose clamp may be required at
connection to prevent leakage.
NOTE: SPLIT units have an internal trap. Do not double trap piping. Failure to
comply may lead to water leaks and possible water damage to surrounding
mounting area. Install drain line with a ¼ inch per linear foot (1.25
cm/linear meter) of pitch.
Installing Ductwork
A. The split units are supplied with one (1) supply duct collar and (1) return duct collar as standard equipment.
B. Install ductwork by folding back the insulation to expose the wire
reinforced vinyl duct. Slip the ductwork over the end of the duct collar and
fasten using two tie wraps supplied withthe kit making sure the ductwork is
tight on the duct collar.
C. Fold the insulation back over the duct and duct collar and secure to collar
using duct tape.
. Installing the Condensing Unit
A. Wine Guardian condensing unit must be mounted horizontally on its base as
shown and be level to +/- ¼” end to end and 1/8” side to side.
B. A minimum of 12 inches is required around the perimeter of the condensing
unit for proper airflow across the unit and for service access.
C. Provide a half-inch downward slope in suction and liquid line toward the
condenser for every 10 feet of line-set to prevent an oil return issue from
occurring. This will allow oil in the system to return to the compressor when
the system is off to ensure the system remains lubricated.
D. Mount system on concrete slab outside above average snow fall heights. Unit
can also be mounted to side of house or within a large indoor crawl space,
attic, or mechanical room that is at least three (3) times the size of the
cellar.
E. Prevent dips, sags, or other low spots that will trap refrigerant oil.
F. Evacuate and leak test indoor unit suction and liquid lines by purging the
dry air charge from the unit by opening the liquid line shut-off valve or
removing the liquid line outlet fitting or plug, whichever is applicable for
your unit.
G. Pressurize and leak test system (the condensing unit comes pre charged). A
pressure equal to the low side test pressure marked on the unit nameplate is
recommended for leak testing.
H. Evacuate the system to hold at 500 microns and break the vacuum with
refrigerant. Charge the system with the correct amount of refrigerant and mark
the amount, with a permanent marker in the space provided on the unit
nameplate. (See chart on below)
I. See the full Wine Guardian Operations and installation manual for
comprehensive charging procedure
System Charging
For Installations using a line-set distance that are Less Than or Equal To 25’
add the required amount of refrigerant shown in the table above.
For Installations using a line-set distance that are Greater Than 25’ add th
required amount of refrigerant shown in the table above THEN add additional
refrigerant based on the rules below:
Models SP25 & SP50
Add an additional 0.50 oz/ft (0.465 kg/meter) for every foot exceeding 25’
Models SP88 & SP200
Add an additional 1 oz/ft (0.93 kg/meter) for every foot exceeding 25’
Wiring the Unit for Power
- Connect line power to the contactor inside the condensing unit as shown
- Run 24 volt low voltage signal wires from Y and C terminals on fan coil (shown in image to left below) to Y and C connections in condenser housing (shown below).
- Turn on power to the condensing unit 24 hours prior to system start-up to allow crankcase heater to warm up
- See pages 15-23 in owners manual for full
24 volt connection wiring schematics/diagrams. Inside of
condensing unit also contains schematic.
24 volt connection
Turn Unit On
A. Turn the ON/OFF switch to the “ON” position. Green
LED lit when unit is on.
B. Follow thermostat instruction to adjust temperature setpoint to 55°F
(13°C).
C. The thermostat may have a built-in time delay for compressor protection,
system should turn on after time de
Read More About This Manual & Download PDF:
References
- Air Innovations | Specialty HVAC • Air Filtration • ECUs
- Troubleshooting and Guides - Wine Guardian® Wine Cellar Cooling Units
- Wine Cellar Cooler | Wine Cooling Systems - Wine Guardian®
- Wine Cellar Cooler | Wine Cooling Systems - Wine Guardian®
- Resources and Owner Manuals - Wine Guardian® Wine Cellar Cooling Units
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>