GE current RefitTM Strip Fixture Retrofit Series Lumination LED Luminaires Installation Guide
- June 4, 2024
- GE current
Table of Contents
Installation Guide
Lumination® LED Luminaires
Refit™ Strip Fixture Retrofit Series (RLB2 Series)
BEFORE YOU BEGIN
Read these instructions completely and carefully.
WARNING
RISK OF ELECTRIC SHOCK
- Turn power off before inspection, installation or removal.
- Properly ground electrical enclosure.
- Luminaire wiring and electrical parts may be damaged when drilling for installation of LED retrofit kit. Check for enclosed wiring and components.
- LED Retrofit Kit installation requires knowledge of luminaires electrical systems. If not qualified, do not attempt installation. Contact a qualified electrician.
- Install this kit only in the luminaires that have the construction features and dimensions shown in the photographs and/or drawings and where the input rating of the retrofit kit does not exceed the input rating of the luminaire.
- To prevent wiring damage or abrasion, do not expose wiring to edges of sheet metal or other sharp objects.
- Do not make or alter any open holes in an enclosure of wiring or electrical components during kit installation.
RISK OF FIRE
- Follow all NEC and local codes.
- Use only UL approved wire for input/output connections. Minimum size 18 AWG or 14 AWG for continuous runs.
Save These Instructions
Use only in the manner intended by the manufacturer. If you have any questions, contact the manufacturer.
Prepare Electrical Wiring
Electrical Requirements
- Limited to use in dry locations.
- The grounding and bonding of the ballast shall be done in accordance with National Electric Code (NEC) Article 600.
- Follow all National Electric Codes (NEC) and local codes.
Grounding Instructions
- The grounding and bonding of the overall system shall be done in accordance with National Electric Code (NEC) Article 600 and local codes.
Installation
1 PRIOR TO INSTALLATION: Turn off power to fixture.
Remove existing:
- Reflectors/ballast covers
- Brackets
- Lamps/lamp holders
2 PREPARE EXISTING FIXTURE FOR INSTALLATION:
Remove all electrical parts and ballast compartment cover leaving only the
supply and grounding leads.
NOTE: Please properly dispose of lamps and removed components.
3 CONNECT DRIVER TO MAIN FEED
NOTE: For sensor SKUs, Please ensure the sensor is properly secured
prior to installing the LED panel. CAUTION: For sensor SKUs, Please be
careful with handling. Keep hand far from sensor location while installing.
4 SECURE LED PANEL TO FIXTURE HOUSING: Once driver is properly energized, adjust bracket by opening or closing to snugly fit against fixture housing and secure LED panel to fixture housing by using the provided #8×1/2″ self drilling screws. If there are no brackets, then use the #8×1/2″ self drilling screws to secure the LED panel directly to the fixture housing.
5 SECURE LED PANEL TO FIXTURE HOUSING (8ft. Kits): Connect the driver LED panel to the support LED panel using the 2 halves of the connector. Once driver is properly energized, adjust bracket by opening or closing to snugly fit against fixture housing and secure LED panels to fixture housing by using the provided #8×1/2″ self drilling screws. If there are no brackets, then use the #8×1/2″ self drilling screws to secure the LED panels directly to the fixture housing.
Wiring Diagrams
4 ft.
Connect Load and Neutral lines from branch power.
8 ft.
Connect Load and Neutral lines from branch power, and connect support panel to
the driver panel.
This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. CAN ICES-005 (A) / NMB-005 (A)”
This device complies with part 15 of the FCC rules for the United States and Industry Canada (IC) license exempt RSS standard(s). Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. Any changes or modifications not expressly approved by the manufacturer could void the user’s authority to operate this equipment. This product is intended for commercial use only.
NOTE: This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment. This equipment generate, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instruction manual, may cause harmful interference to radio communications. Operation of this equipment is a residential area is likely to cause harmful interference in which case the user will be required to correct the interference at his own expense.
© 2020 Current Lighting Solutions, LLC. All rights reserved. GE and the GE monogram are trademarks of the General Electric Company and are used under license. Information provided is subject to change without notice. All values are design or typical values when measured under laboratory conditions.
www.GECurrent.com | IND535 (Rev 04/29/20) | A-1010914
References
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>