TECHNICAL DATA

MODEL

Detector resolution

| CHALLENGER-15
---|---
384×288 px
Pixel size| 17 µm
Frame rate| 50 Hz
Eyepiece lens| 15 mm, fixed focus
Field of vision| 24.9 ° × 18.8 °

44.1 m × 33.1 m (H × V)

Display| LCOS, 720 × 560
Magnification| 1.5
Digital zoom| 2x, 4x
Max. battery life**| 6 h
Weight| 270 g
Dimensions| 169 × 57 × 60 mm
Internal memory| 8 GB
Recording formats| JPG (picture), MP4 (video)
Operating temperature| −10°C to +50°C
Water resistance| IP67
Detection range

(Target: 1.8 m × 0.5 m, P (n) = 99%)

| 530 m

We reserve the right to make changes to improve the technical parameters of the unit. / ** The actual operating time depends on the temperature of the battery and the intensity of use of the WiFi function and the built-in video recorder.

COMPONENTS AND CONTROLS

  1. Lens

  2. Power button

  3. Picture/video button

  4. Menu button

  5. Zoom button

  6. Eyepiece

  7. Dioptre adjustment wheel

  8. Tripod thread

  9. USB-C interface
    with LED display

SCOPE OF SUPPLY

  • 1x Challenger-15
  • 1x charging cable
  • 1x Operating Manual

SAFETY INSTRUCTIONS

The nominal charging voltage of this product is 5 V.

Please charge in good time when the battery is low to avoid a decreased service life due to deep discharge of the battery.
The thermal imager is not recommended to be used in high-temperature environments for a long time. If the temperature is too high, the imager will enter the high-temperature protection state, and automatically shut down.
The recommended temperature for use is −10°C to +50°C.
Ensure that the USB-C interface cover on the bottom of the thermal imager is tightly closed when used in humid environments, e.g. on rainy days.

  • If the unit is not used for a long period of time, it should be charged at least every 2 months during storage and kept in a dry and ventilated environment.
  • The unit should not be charged in an environment above 40 °C.

Disposal of waste electrical equipment and batteries

Do not dispose of waste electrical equipment and batteries in the household waste. Please hand them in to your local recycling centre. Batteries should be fully discharged when disposed of.

The devices are in conformity with the EU directives:
EMC Directive 2014/35/EU
RoHS Directive 2011/65/EU

OPERATION

CAUTION!
Do not point the lens of the unit at intense energy sources, including laser units and the sun. Otherwise, there is a risk of damaging electronic components of the unit. Damage resulting from non-compliance with the operating instructions is not covered by the warranty.

Before use
A technical inspection of the device is recommended before use.

  • Check the external appearance of the device: There should be no cracks in the casing.
  • Check the condition of the lens and eyepiece: There should be no cracks, greasy spots, dirt or other deposits.
  • Check the condition of the battery: It should be charged if necessary.
  • Check all electrical contacts: There must be no salts or oxidised spots.

SWITCHING ON AND OFF

  • Switch on the unit by pressing and holding the Power button. The start screen appears and after a few seconds the image is displayed.
  • Switch off the unit by pressing and holding the Power button.

STANDBY MODE
To increase the battery life, the unit can be set to standby mode.

  • When the unit is switched on, briefly press the Power button to enter standby mode.

The unit goes into standby mode.

  • Briefly press the Power button again to wake the unit from standby mode.
    The unit wakes up immediately; there is no waiting time as is the case when the unit is switched on after it has been switched off completely.

DIOPTRE ADJUSTMENT
The dioptre adjustment adjusts the eyepiece of the unit to the individual vision of the user.
Close the lens cover and turn the dioptre adjustment wheel clockwise or anticlockwise until you can see the symbols in the display clearly.

INFO BAR

The info bar in the upper right-hand image corner shows the digital zoom setting, the memory capacity (no bar = empty) and the charge status of the built-in battery (three bars = full). If WiFi is activated, the WiFi symbol from the menu is also displayed in the info bar.

MENU ICONS
The menu bar is located on the left edge of the screen.

  • Press the picture/video button or the zoom button to switch between the menu items.
  • Press the menu button to select a menu item.
  • Long press the menu button to exit the menu again.

LIEMKE Challenger 15 Thermal Imaging Monocular-6

SWITCHING THE IMAGE MODE

  • Press the menu button briefly to switch the image mode between White Hot, Black Hot, Fusion and Red Hot modes.

LIEMKE Challenger 15 Thermal Imaging Monocular-7

  1. White Hot – ideal for precise response
  2. Black Hot – ideal for quick finding
  3. Fusion – for detection at close range, e.g. thermal bridges
  4. Red Hot – for rapid detection of heat sources

DIGITAL ZOOM

  • Briefly press the zoom button to zoom the picture to 1× to 2×, 4× and back to 1x.
    The digital zoom factor is displayed in the info bar.

TAKING PICTURES AND VIDEOS

  • In normal display mode, briefly press the picture/video button to take aA picture.
    The display indicates that the picture has been saved.

  • Long press the picture/video button to start recording a video.
    During video recording, the recording time is displayed in the upper left corner of the screen.

  • Long press the picture/video button again to stop recording and save the video.

The display indicates that the video has been saved.
The remaining space in the internal memory is displayed in the info bar.

CALIBRATION FUNCTION (FCC)
During use, the image gradually deteriorates due to the changing background temperature of the sensor. This must be compensated for by periodically calibrating the sensor. For calibration, an inter-nal shutter is actuated, which makes a faint clicking sound. The image briefly freezes while the shutter is closed.

  • In FCC Auto mode, calibration is performed automatically at intervals set by the unit.
  • In FCC Manual mode, no automatic calibration is performed. The manual mode allows the user to determine the time when the image briefly freezes.
  • If you notice a deterioration in picture quality during use, start manual calibration by pressing and holding the zoom button.
  • In FCC External mode, no automatic calibration is performed either. Calibration takes place without the internal shutter and is therefore completely silent. The lens cap must be closed during calibration (this replaces the internal shutter). If the lens cap is inadvertently not closed when performing external calibration, the displayed image is overlapped by a still image of the scene displayed during calibration. This can be corrected by properly calibrating again with the lens cap closed.

STADIAMETRIC RANGEFINDER
For stadiametric distance measurement, you must first set the target size (height) of the target to which you want to measure the distance. To do this, proceed as follows:

  • Select the menu item Stadiametric Rangefinder in the menu and confirm it with the menu button.
  • Press the zoom button to enter the Parameters submenu.

Here you can choose between four different target sizes “wolf”,”bear”, “deer” and “individual” using the picture/video button or the zoom button.

  • Confirm your selection with the menu button.

In the sub-item “individual” you can define a custom target size in the range of 0.1 to 9.9 m height using the picture/video button or the zoom button.

  • Confirm the set value with the menu button.

To measure the distance, proceed as follows:

  • Select the menu item Stadiametric Rangefinder in the menu and confirm it with the menu button.

A long horizontal line with a short vertical line pointing upwards appears in the display image.

  • Place the intersection of the two lines at the top edge of the target to be measured and press the menu button (step 1).

The vertical line flashes briefly and then changes to the underside of the horizontal line.

  • Now place the intersection of the two lines at the lower edge of the target to be measured and press the menu button again (step 2).
    The distance to the target is then displayed in the upper left corner of the image.

LIEMKE Challenger 15 Thermal Imaging Monocular-8

Please note: The precision of the distance measurement depends primarily on the correspondence between the defined and the actual target size and on the smoothness of the hand during the measuring process. The sizes of the pre- configured targets are only indicative and may vary.

BLIND PIXEL CORRECTION
If a pixel error occurs permanently despite calibration and restart, it can be corrected as follows:

  • Select the menu item Blind Pixel Correction and open it.
  • Press the menu button to set the step size of the cursor adjustment to select the faulty pixel (step size 1, 5 or 10 pixels).
  • Press the menu or picture/video button to select the direction of movement of the cursor (left, right, up, down).
  • Move the cursor to the missing pixel step by step using the menu button.

An enlarged view of the selected pixel is shown in the lower right corner of the display. If the faulty pixel is covered by the menu display, the display can be mirrored by pressing and holding the picture/video button.

  • When the pixel is selected, correct it by a pressing and holding the picture/video button.

The number of corrected pixels is displayed at the bottom of the image.

  • Close the menu with a long press of the menu button.

HOT SPOT TRACKING
When hot spot tracking is activated, a green crosshair appears tracking the hottest object on the screen.

CHARGING THE BATTERY
The device is equipped with an internal, rechargeable battery that is charged via the USB-C interface on the underside of the hous-ing. The battery indicator in the upper right corner of the screen shows the charge level of the battery.

  • Please charge the battery at the latest when a low battery charge (red battery symbol) is displayed.
    You can charge the battery with the supplied power supply unit or a portable power supply unit such as a USB powerbank. A pow-erbank with 4000 mAh capacity can double the operating time. The LED indicator next to the USB-C interface lights up red during charging and changes to green when the battery is fully charged. The unit can be charged during operation. It charges faster than is needed for ongoing operation.

TRANSFERRING PICTURES AND VIDEOS

Once you have connected the unit to your computer via a USB cable and switched on the unit, it acts as a mass storage device so that you can view, copy or delete your pictures and videos on the computer.

WIFI FUNCTION AND APP CONNECTION

The app and information on the app connection can be found at: https://liemke.shop/medien

MAINTENANCE

  • Activate the WiFi function in the menu.
    Maintenance should be carried out at least twice a year and consist of the following actions.

  • Wipe the external surfaces of metal and plastic parts free of dust and dirt with a cotton cloth. Silicone grease can be used for this purpose.

  • Clean the contacts of the unit with a non-greasy organic solvent.

  • Check the glass surfaces of the eyepiece and the lens. If necessary, remove dust and sand from the lenses (preferably using a non-contact method). Cleaning of the external surfaces of the optic should be done with substances designed especially for this purpose.

TROUBLESHOOTING

This table lists all the problems that can occur when using the unit. Carry out all recommended checks and repairs as described in the table.
If an error occurs that is not listed in the table or if you cannot rectify an error yourself, the unit should be handed over to the responsible service centre for repair.

Malfunction Possible reason Correction
The thermal imager cannot be switched on. The battery is complete- ly
discharged. Charge the battery.
Can‘t be powered by an external power source. USB cable is damaged. Replace

USB cable.
The external power source is discharged| Charge the external power source (if nec- essary).
The image is blurred, with vertical lines and an uneven background.| Calibration needed.| Perform image cali- bration as described in section 14. “Calibration Function (FCC)”.
The image is too dark.| The brightness setting is too low.| Set the

display brightness

Coloured lines appear on the display or no image is shown.| The unit has been exposed to static elec- tricity during operation.| After the unit has been exposed to static elec- tricity, the unit will either restart automatically or you will have to switch it off and on again manually.
Low image quality/re- duced detection range.| These problems can occur when an observation is carried out on a day with difficult weather condi- tions (high humidity, snowfall, rain, fog etc.).
The smartphone or tablet PC cannot be connected to the unit.| The unit’s password has been changed.| Delete the network and reconnect using the existing password.
| The unit is located in an area with a large num- ber of WiFi networks that may cause interference.| To ensure stable WiFi operation, place the unit in another location with fewer or no WiFi networks at all.
No WiFi signal available or interrupted.| The unit is outside the WiFi range. There are obstacles between the unit and the receiver (e.g. concrete walls).| Place the unit within line of sight and range of the WiFi signal.
When the unit is used at low temperatures, the image quality of the surroundings is worse than at temperatures above freezing.| At temperatures above freezing, the observed objects (surroundings and background) are dif- ferent temperatures due to thermal conductivity, resulting in a high temperature contrast. Thus, the picture quality achieved by the unit is higher.

At low outdoor temperatures, the observed objects (background) usually cool down to about the same temperature, so that the temperature contrast is considerably reduced and the image quality (details) is lower as a result. This is a property of thermal imagers.

LIEMKE GmbH & Co.KG
Detmolder Straße 629b
D – 33699 Bielefeld
Germany
+49 (0) 521 329 695 – 0
office@liemke.com
www.liemke.com

Kontakt technischer Service Contact technical service
Blaser Group Wetzlar GmbH & Co. KG Liemke Service
Wilhelm-Loh-Straße 1
D-35578 Wetzlar
+49 (0) 6441 56691 700
service.bgw@blaser-group.com

References

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>

Related Manuals