Minoston MP31Z-800S Z Wave Smart Plug User Guide
- June 17, 2024
- Minoston
Table of Contents
- Minoston MP31Z-800S Z Wave Smart Plug
- FCC STATEMENT
- SAFETY WARNING
- SPECIFICATION
- Introduction
- Key Features
- Product Overview
- Button & Indicator Function Description
- Adding Your Device To Hub
- QR Code and DSK
- Command Class
- Basic Set Mapping
- Indicator Command Class
- Association Group
- Configuration Parameters
- Read User Manual Online (PDF format)
- Download This Manual (PDF format)
Minoston MP31Z-800S Z Wave Smart Plug
FCC STATEMENT
Federal Communications Commission (FCC) Statement FCC Caution:
Any changes or modifications not expressly approved by the party responsible
for compliance could void the user’s authority to operate this equipment. This
device complies with Part 15 of the FCC Rules. Operation is subject to the
following two conditions: (1) This device may not cause harmful interference,
and (2) this device must accept any interference received, including
interference that may cause undesired operation.
NOTE:
This equipment has been tested and found to comply with the limits for a Class
B digital device, under Part 15 of the FCC Rules. These limits are designed to
provide reasonable protection against harmful interference in a residential
installation. This equipment generates, uses and can radiate radio frequency
energy and, if not installed and used by the instructions, may cause harmful
interference to radio communications. However, there is no guarantee that
interference will not occur in a particular installation. If this equipment
does cause harmful interference to radio or television reception, which can be
determined by turning the equipment off and on, the user is encouraged to try
to correct the interference by one or more of the following measures: Reorient
or relocate the receiving antenna. Increase the separation between the
equipment and the receiver. Connect the equipment to an outlet on a circuit
different from that to which the receiver is connected. Consult the dealer or
an experienced radio/TV technician for help. This equipment should be
installed and operated with a minimum distance of 20cm between the radiator
and your body.
SAFETY WARNING
- RISK OF FIRE
- RISK OF ELECTRICAL SHOCK
- RISK OF BURNS
CONTROLLING APPLIANCES:
EXERCISE EXTREME CAUTION WHEN USING Z-Wave™ DEVICES TO CONTROL APPLIANCES.
OPERATION OF THE Z-Wave™ DEVICE MAY BE IN A DIFFERENT ROOM THAN THE CONTROLLED
APPLIANCE, ALSO ANUNINTENTIONAL ACTIVATION MAY OCCUR IF THE WRONG BUTTON ON
THE REMOTE IS PRESSED. Z-Wave™ DEVICES MAY AUTOMATICALLY BE POWERED ON DUE TO
TIMED EVENT PROGRAMMING. DEPENDING UPON THE APPLIANCE, THESE UNATTENDED OR
UNINTENTIONAL OPERATIONS COULD POSSIBLY RESULT IN A HAZARDOUS CONDITION. FOR
THESE REASONS, WE RECOMMEND DO NOT RETURN THIS PRODUCT TO THE STORE THE
FOLLOWING: DO NOT USE Z-Wave™ DEVICES TO CONTROL ELECTRIC HEATERS OR ANY OTHER
APPLIANCES WHICH MAY PRESENT A HAZARDOUS CONDITION DUE TO UNATTENDED OR
UNINTENTIONAL OR AUTOMATIC POWER ON CONTROL.
SPECIFICATION
ITEM | INFORMATION |
---|---|
Model | MP31Z |
Power Supply | AC 120V 60HZ |
Signal(Frequency) | 908.42MHz |
Long Range | Support |
Range | Up to 100 feet line of sight between the Wireless Controller and the |
closest Z-Wave™ receiver module.
Operating Temperature Range| 5-104° F (-10-40° C)
- Specifications are subject to change without notice due to continuing product improvement
- Website: www.minoston.com\.
Introduction
- This product can be operated in any Z-Wave network with other Z-Wave Plus™ certified devices from other manufacturers.
- All non-battery-operated nodes within the network will act as repeaters regardless of vendor to increase the reliability of the network. Each module is designed to act as a repeater, which will re-transmit a radio frequency (RF) signal by routing the signal around obstacles and radio dead spots to ensure that the signal is received at its intended destination.
- MP31Z is a security-enabled Z-Wave Plus™ device. A security-enabled Z-Wave Plus™ Controller must be used to fully utilize the product.
Type
- GENERIC_TYPE: GENERIC_TYPE_SWITCH_BINARY(0x10)
- SPECIFIC_TYPE: SPECIFIC_TYPE_NOT_USED(0x00)
- APP ICON TYPE: ICON_TYPE_GENERIC_ON_OFF_POWER_SWITCH(0x0700)
Key Features
- Remote ON/OFF control via the Z-Wave™ controller
- Manual ON/OFF control
- Support Association Group and Auto Report switch status
- Support firmware upgrades via Over-the-air (need Gateways support)
- Support Z-Wave™ Long Range (need Gateways support)
- Support Smart Start
Product Overview
- A. on/off button
- B. LED
- C. Output Outlet
- E. Input
Button & Indicator Function Description
Button Definition
-
Press 1x: Turn on/off Outlet Z-Wave network inclusion(ADD) /exclusion(REMOVE)
-
Factory Reset: Remove the switch from power. Press and hold the manual button, plug the switch in and continue holding the manual button for 3 seconds.
Note: Please use this procedure only when the network primary controller is missing or otherwise inoperable. -
Press 10x: Change the value of parameter 3.
Adding Your Device To Hub
- The device supports two methods of inclusion, When using a Z-Wave Plus™ certified controller choose Network Wide Inclusion or SmartStart.
- TAP the button once times to ADD/INCLUDE the device.
- Network Wide Inclusion To A Z-Wave™ Network
- TAP the button once times to REMOVE/EXCLUDE the device
- Refer to your primary controller instructions to process the inclusion/exclusion setup procedure.
- When prompted by your primary controller, click the Z-Wave button one time.
- The device is compatible with SmartStart.
SmartStart-enabled products can be added to a Z-Wave™ network by scanning the Z-Wave QR Code found on the top of the outlet or the back of the box with a controller providing SmartStart inclusion. No further action is required and the SmartStart product will be added automatically within 10 minutes of being switched on and in the network vicinity.
Note:
Z-Wave Long Range device can only support be included via SmartStart.Extract
the DSK from the end device paste it into the Dsk Value in the PC Controller,
and make sure the ‘ Long Range’ option is ticked.
QR Code and DSK
- The QR code are stocked to the side of the case, DSK is included in the QR code.
- The DSK code can be found on the DSK label which is attached on the packaging box.
PACKAGE
DEVICE
Command Class
Endpoint ROOT CC List
Command Class Name | Version | Required Security Class |
---|---|---|
Z-Wave Plus Info | V2 | none |
Security 2 | V1 | none |
Supervision | V1 | none |
Transport Service | V2 | none |
Association | V2 | highest granted |
Association Group Information | V3 | highest granted |
Multi Channel Association | V3 | highest granted |
Version | V3 | highest granted |
Manufacturer Specific | V2 | highest granted |
Device Reset Locally | V1 | highest granted |
Power Level | V1 | highest granted |
Indicator | V3 | highest granted |
Firmware Update Meta Data | V5 | highest granted |
Configuration | V4 | highest granted |
Switch Binary | V2 | highest granted |
Basic | V2 | highest granted |
Basic Set Mapping
- The Basic Set command is mapped to the Binary Switch Set command.
- The Basic Report command is mapped to the Binary Switch Report command.
Indicator Command Class
The indicator (blue colour) will flash according to the indicator set command received from HUB.
Indicator ID | Property ID |
---|---|
0x50 (NODE IDENTIFY) | 0x03(ON OFF PERIOD) |
0x50 (NODE IDENTIFY) | 0x04(ON OFF CYCLES) |
0x50 (NODE IDENTIFY) | 0x05(ONE TIME ON OFF PERIOD) |
Association Group
Endpoint ROOT
ID | Name | Node Count | Profile | Function |
---|
1
| ****
Lifeline
| ****
5
| ****
General: Lifeline
| Device Reset Locally Notification Indicator Report
Switch Binary Report
2| Basic Set| 5| Control: Key01| Basic Set
Configuration Parameters
Number| Name| Information| Format/Size| Read Only|
Altering| Advanced| MIN| MAX| Default
---|---|---|---|---|---|---|---|---|---
0 3| Reaction of led| Change the reaction of the indicator.| 1 byte unsigned
integer| NO| NO| NO| 0| 3| 1
41| Indicator brightness| Setting indicator’s brightness.| 1 bytes unsigned
integer| NO| NO| NO| 0| 2| 0
42| Restore status| Restore status after power failure.| 1 bytes unsigned
integer| NO| NO| NO| 0| 2| 0
84| Reset factory| Set 1 to reset the factory default| 1 byte unsigned
integer| NO| NO| NO| 0| 1| 0
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>