Ledvion LV40001 IP20 Batten Integrated LED User Manual
- June 17, 2024
- Ledvion
Table of Contents
Ledvion LV40001 IP20 Batten Integrated LED
Product Information
Specifications:
- Model: LV40001, LV40002, LV40003, LV40004, LV40005, LV40006
- Watt: 15W, 30W, 40W
- Fixture Lumen: 1680Lm, 3360Lm, 4480Lm
- IP Value: IP20
- CRI: >80
- CCT: 4000K (LV40001, LV40002, LV40003), 6500K (LV40004, LV40005, LV40006)
- Dimmable: No
- IK Rating: IK08
- Dimensions: Vary based on model (see below)
- Input Power: AC: 220-240V, 50/60Hz
Product Usage Instructions
Installation Instructions:
Installation should only be done by persons with electrical technical
knowledge and experience. These products are not suitable for installation in
locations near the sea or in other environments with a corrosive atmosphere.
Technical Data Overview:
The IP20 Batten Integrated LED comes in various models with different wattage,
lumen output, and colour temperatures. The fixtures are non-dimmable and have
an IK08 rating for impact resistance.
Dimensions:
The dimensions vary based on the model:
- LV40001 & LV40002: 630 x 71 x 25 mm
- LV40003 & LV40004: 1230 x 71 x 25 mm
- LV40005 & LV40006: 1530 x 71 x 25 mm
Power Input Requirements:
The product operates on AC power ranging from 220-240V at a frequency of
50/60Hz. Ensure the input power matches the specified requirements to avoid
damage to the fixture.
Frequently Asked Questions (FAQ):
-
Q: Can this product be used in locations near the sea?
A: No, these products are not suitable for installation at locations near the sea or in other environments with a corrosive atmosphere. -
Q: Is the IP20 Batten Integrated LED dimmable?
A: No, the fixtures are non-dimmable. -
Q: What is the colour rendering index (CRI) of these fixtures?
A: The fixtures have a CRI greater than 80, ensuring good colour rendering for illuminated spaces.
Attention
Installation should only be done by persons with electro-technical knowledge
and experience. These products are not suitable for installation at locations
near the sea or in other environments with a corrosive atmosphere.
TECHNICAL DATA
Model| Watt| Fixture Lumen| IP Value| CRI| CCT|
Dimmable| IK Rating| Dimensions| Input Power
---|---|---|---|---|---|---|---|---|---
LV40001| 15W| 1680Lm| IP20| >80| 4000K| No| IK08| 630 x 71 x 25 mm| AC:
220-240V, 50/60Hz
LV40002| 30W| 3360Lm| IP20| >80| 4000K| No| IK08| 630 x 71 x 25 mm| AC:
220-240V, 50/60Hz
LV40003| 40W| 4480Lm| IP20| >80| 4000K| No| IK08| 1230 x 71 x 25 mm| AC:
220-240V, 50/60Hz
LV40004| 15W| 1680Lm| IP20| >80| 6500K| No| IK08| 1230 x 71 x 25 mm| AC:
220-240V, 50/60Hz
LV40005| 30W| 3360Lm| IP20| >80| 6500K| No| IK08| 1530 x 71 x 25 mm| AC:
220-240V, 50/60Hz
LV40006| 40W| 4480Lm| IP20| >80| 6500K| No| IK08| 1530 x 71 x 25 mm| AC:
220-240V, 50/60Hz
Hardware
Warning
- Please make sure to turn off the power before starting the installation.
- The light source of this luminaire is not replaceable, when the light source reaches its end of life the whole luminaire should be replaced.
- Before installation, you must carefully check the integrity of the product and accessories.
- When installing, products and flammable materials to ensure that at least 0.2m distance, lightning cannot be installed in the zenith or heat wall, pay attention to low voltage and high voltage electrical wiring separately.
- If the external flexible cable or cord of this luminaire is damaged, it shall be exclusively replaced by the manufacturer or his service agent or a similarly qualified person to avoid a hazard.
- To ensure that the power cord has enough length, do not kink cables. Output cables should be laid separately and at a distance from other cables.
- Install only by a certified electrician.
INSTALLATION INSTRUCTIONS
- Choose the right position, drill two holes and insert the screw (make sure the distance between the holes is no less than S0mm, Less than the bracket length).
- Shrapnel points it at the hole and then install the screws.
- Press the lamp body firmly into the mounting buckle to fix the lamp body, Slide the lamp body along the mounting buckle to the desired position as needed.
- Connect the wiring, use insulating tape, and waterproof tape for insulation and waterproofing, turn the power ON and test.
PACKING
- IP20 Batten (1PC)
- Instruction Manual (1PC)
- Quick connector, clips & screws
Symbols Description
- This marking indicates that this product should not be disposed of with other household wastes.
- LED battens are suitable for 50/60Hz operation.
- Led lamps to be used in dry conditions or in a luminaire that provides protection.
- Caution, risk of electric shock.
- LED battens are NOT suitable for dimming.
- Led battens are not suitable for emergency operations.
Notes on Disposal
- The product is designated for separate collection at an appropriate collection point.
- Do not dispose of the product with household waste. For more information, contact the retailer or the local authority responsible for waste management.
Care
Before cleaning the unit, disconnect it, if necessary from other components; do not use aggressive cleaning agents. The unit has been carefully checked for defects. If nevertheless, you do have cause for complaint, please go back to the retailer where you bought the product together with your proof of purchase. We are not liable for damage arising from incorrect handling, improper use or wear or tear. We reserve the right to make technical modifications.
Safety Instruction
General Safety
- Read the manual carefully before use. Keep this manual for future reference.
- Only use the product for its intended purposes. Do not use the product for other purposes than described in the manual.
- Do not use this product if any part is damaged or defective. If the product is damaged or defective, replace the product immediately.
- This product shall not be used by children without the supervision of an adult.
- Children shall not play with the device.
- Do not modify the product in any way.
- Do not expose the product to water or moisture. (IP 20)
- Do not immerse the product in water. (IP 44 – 1P 67)
- Keep the product away from heat sources.
- Do not block the ventilation openings.
- Do not look directly into the LED lamp.
- Keep a minimum distance of 1 meter between the lamp and the surface being illuminated.
Electrical safety
- To reduce the risk of electric shock, this product should only be opened by an authorized technician when service is required.
- Do not use the product if the cable or plug is damaged or defective. When damaged or defective, it must be replaced by the manufacturer or an authorised repair agent.
- Before use, always make sure that the voltage is the same as the voltage on the rating plate of the device.
- Make sure that the cable does not hang over the edge of a worktop and cannot be caught accidentally or tripped over.
Warning
- The light source contained in this luminaire shall only be replaced by the manufacturer his service agent or a similar qualified person.
- Caution, risk of electric shock.
- The external flexible cable or cord of this luminaire cannot be replaced; if the cord is damaged, the luminaire has to be destroyed.
Disclaimer
- Designs and specifications are subject to change without notice. All logos, brands and product names are trademarks or registered trademarks of their respective holders and are hereby recognized as such.
- Please visit us online on our website: www.ledvion.com For more information about our company and our products.
Documentation
- The product has been manufactured and supplied in compliance with all relevant regulations and directives, valid for all member states of the European Union. The product complies with all applicable specifications and regulations in the country of sale.
- Formal documentation is available upon request. The formal documentation includes, but is not limited to the Declaration of Conformity, the Material Safety Data Sheet and the product test report.
Declaration
CE declaration
This product complies with the following directives:
- LVD: 2014/35/EU
- EMC: 2014/30/EU
- RoHS: 2011/65/EU
Additionally, for Products with Radio transmitter units:
- RED: 2014/53/EU
The complete Declaration of Conformity Document (DOC) can be found on our website.
Contact Information
- 5692 DH Son en Breugel Ekkersrijt 4304 The Netherlands
- www.ledvion.com.
References
Read User Manual Online (PDF format)