UV-1530 COMPONENT DIAGRAM
READ ENTIRE MANUAL THOROUGHLY
BEFORE INSTALLING THIS ULTRA-VIOLET LIGHT UNIT
UV-1530 SETUP INSTRUCTIONS
-
First remove lamp from packaging.Try not to touch the bulb with your hands.
The oils may cause hot spots on the bulb and early failure. -
Bulbs should be replaced yearly.
Attach the electrical connections to both ends of the bulb. Make sure bulb is clean of grease and oil.Make sure housing collar is firmly tightened. Do not over tighten as this will cause glass inner sleeve to break.Insert bulb and wiring into sleeve.Seat rubber boot over the collar.Insert stem elbow fittings. Make sure they are completely seated.Mount UV with supplied clips to the RO filter.
CONNECT WATER LINES, START THE SYSTEM AND CHECK FOR LEAKS.
IF NO LEAKS EXIST, PLUG IN THE UV FILTER AND ENJOY!
UV-6010/UV-LB/UV-XL/UV-12 COMPONENT DIAGRAM
READ ENTIRE MANUAL THOROUGHLY
BEFORE INSTALLING THIS ULTRA-VIOLET LIGHT UNIT
- Housing
- Ultraviolet Bulb
- Quart Sleeve
- Power Transformer
- Electrical Connection / Rubber Boot
- Stem Elbow Fittings
- Mounting Clips
UV-6010/UV-LB/UV-XL/UV-12 SETUP INSTRUCTIONS
- First remove lamp from packaging.Try not to touch the bulb with your hands. The oils may cause hot spots on the bulb and early failure.
- Bulbs should be replaced yearly.
Attach the electrical connections to the end of the bulb. Make sure bulb is clean of grease and oil. Make sure housing collar is firmly tightened. Do not over tighten as this will cause glass inner sleeve to break. Insert bulb and wiring into sleeve. Seat rubber boot over the collar. Insert stem elbow fittings. Make sure they are completely seated.
Mount UV with supplied clips to the RO filter.
AREAS OF APPLICATIONS
• RO Water System
• De-ionization
• Rinse Water| • Hot/Cold Water Dispenser
• Coffee Machine
• Wash Water| • Water purification System
• Potable Water
• Bottle Water
---|---|---
ELECTROMAGNETIC WAVE DRAWING
NOTICES:
-
When the GX UV is installed and running, the first 280cc of water will be warmer than normal.
When the system to which the UV is connected is not in use, the water will warm up after 25 minutes. You may flush the GX System filter before use to remove the warmer water. -
Do not look directly at the ultraviolet rays emitting from the UV lamp or it may cause eye damage.
-
Unplug the UV electrical cord before servicing and/or cleaning the UV lamp or housing.
MODEL SPECIFICATIONS
PART #| IN / OUT| VOLTAGE| BALLAST| FLOW
RATE| MAXIMUM
OPERATING
PRESSURE| LAMP LIFE| AUDIBLE LAMP
ALARM
---|---|---|---|---|---|---|---
UV-1530| 1/4″ NPT| 110V-120V / 60HZ
220V-240V (special
order)| 6W| 1 GPM| 85psi| 5.000 hrs.| No
UV-6010| 1/4″ NPT| 110V-120V / 60HZ
220V-240V (special
order)| 14W| 2 GPM| 125psi| 9,000 hrs.| yes
UV-LB| 1/2″ NPT| 110V-120V / 60HZ
220V-240V (special
order)| 24W| 4 GPM| 125psi| 9,000 hrs.| yes
UV-XL| 1/2″ NPT| 110V-120V / 60HZ
220V-240V (special
order)| 32W| 6 GPM| 125psi| 9,000 hrs.| yes
UV-12| 3/4″ MNPT| 110V-120V / 60HZ
220V-240V (special
order)| 39W| 12 GPM| 125psi| 9,000 hrs.| yes
GROWONIX SYSTEM WARRANTY
For a period of one year from the date of original purchase, we will replace or repair any part of the GrowoniX reverse osmosis water system that we find to be defective in operation du e to faulty materials or workmanship with the EXception of the replaceable filters and membranes.
GENERAL CONDITIONS
Damage to any part of this reverse osmosis system because of misuse;
misapplication; negligence; alteration; accident; installation; or operation
contrary to our instructions, incompatibility with accessories not installed
by GrowoniX, or damage caused by freezing, flood, fire, or Act of God, is not
covered by this warranty. In all such cases, regular charges will apply. This
limited warranty does not include service to diagnose a claimed malfunction in
this unit. This warranty is void if the claimer is not the original purchaser
of the unit or if the unit is not operated under normal municipal water or
well water conditions.
GrowoniX assumes no liability in connection with this reverse osmosis system.
GrowoniX assumes no liability for any damages incurred through the use of this
product. It is the responsibility of the end user to gauge the safe use of
this product in the environment where it is applied. We do not authorize any
person or representative to assume for us any other obligations on the sale of
this reverse osmosis system. The information given out in the manual we
believe to be true, but are offered to you in good faith without guarantee
because each application of this product is different and beyond our control.
THE FOLLOWING STANDARD OPERATING CONDITIONS FOR RESIDENTIAL/COMMERCIAL REVERSE
OSMOSIS SYSTEMS MUST BE MET FOR WARRANTY TO BE VALID.
| Water Pressure| pH Range| Maximum TDS| Water Temp
---|---|---|---|---
Standard System| 40-80 psi| 11-Feb| 2000 ppm| 40-100 F
GROWONIX RETURN POLICY
MERCHANDISE RETURN DETAILS AND PROCEDURE:
If any merchandise was defective —we will refund the full purchase price upon
receiving and reviewing the merchandise returned in undamaged condition.
RMA NUMBER:
You must first obtain a Return Merchandise Authorization (RMA) number from
GrowoniX.com. Any products sent to GrowoniX without an RMA number will not
receive a refund and may be returned to the sender at their expense.
All refund amounts will be based on the manufacturer’s warranty and GrowoniX
return policy. Refunds will be issued back using the payment method you used
when you placed your order. Refunds take up to 3-5 business days to process
once we receive the return.
PACKAGING :
Please kindly re-pack the product in its original box, or a box of equivalent
strength. The unit should be packed in the same manner as it came to prevent
damage in shipping. Please return everything that was in the original box,
including any free items if applicable. Be sure to drain out all water from
wet systems and parts and wrap them in plastic bags before packing.
RETURN TO:
We will provide you with an GrowoniX warehouse address for return merchandise
when we issue the RMA number.
www.growonix.com toll free 888.406.8521, office 818.510.0264, sales@growonix.com
Built in the U.S.A.
References
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>