Hanchen 550 LBS Automatic Gate Opener Instruction Manual
- June 17, 2024
- Hanchen
Table of Contents
Hanchen 550 LBS Automatic Gate Opener
INSTRUCTION MANUAL
Specifications
- Applicable door width: 11.8 ft
- Applicable door weight: 550 Lbs
- Input voltage: DC 24V
- Power: 45W
- Voltage output of door lock control: DC 12V
- Voltage output of light: DC 24V
- Remote control distance: 49 ft
- Motor speed ratio: 1200
- Temperature: -40 ~ 135 degrees Fahrenheit
- Durability: 2 million times
- Package dimension: 16126 inches
- Weight: 17.8 Lbs
1. SAFETY WARNING
I. Installation warning
1. Before installation, please carefully read the user manual and
precautions, and then carry out assembly, installation, and debugging
operations to avoid unnecessary losses.
2. All installation, debugging, and maintenance work must be carried out with
the main power supply disconnected.
3. The controller power supply must have safety grounding measures.
4. Please be careful when touching this product during installation to avoid
collision, squeezing, falling to the ground, or coming into contact with any
liquid. This product should be placed away from high temperatures and open
flames.
5. The controller of this product is controlled by 24V low voltage, please do
not directly connect to 110V high voltage.
II. Operation warning
1. This product is not suitable for use by children, people with
disabilities, or those who without basic knowledge and experience, unless
accompanied by professional trained people who be responsible for their
safety.
2. During equipment debugging, it is important to keep children or elderly
people away from the site to avoid accidental injuries caused by excessive
force during debugging errors.
III. Maintenance warning
1. When the equipment malfunctions, please cut off the power supply of the
equipment first and then disassemble it to check the problem.
2. When checking the support arm, please be sure to place a no pass sign to
prevent the folding arm from squeezing the hands of maintenance personnel and
avoiding accidents.
2. PRODUCT INTRODUCTION
I. Introduction
The automatic door opener is designed for automatic control of single or
double iron gates, villa doors, glass doors, electric small doors, and
pedestrian walkway swing doors. It can be opened and closed automatically
through access control devices, facial recognition devices, mobile phones, and
license plate recognition devices. The driving motor adopts a new type of
brushless DC motor, with sufficient and stable force. The controller adopts
military motherboard technology, providing a more user-friendly operating
experience.
II. Feature
Compact: Especially suitable for pedestrian passage doors, it can also be
installed on 5cm wide small door pillars Safety: irreversible motor, reverse
arm, built-in closing limit (when using a complete curved arm)
Practical: Small curved arms are suitable for installation under various
special conditions, such as small door pillars or small installation spaces
Fast: No need to wait, the fastest time to turn on or off is only 3
seconds (in ideal conditions, use a shortened curved arm to open 90 °)
Soft start and soft stop function, greatly protecting motor gears and
extending product service life
III. Parameter
Applicable door width | <11.8 ft | Remote control distance | >49 ft |
---|---|---|---|
Applicable door weight | <550 Lbs | Motor speed ratio | 1:200 |
Input voltage | DC 24V | Temperature | -40℉ ~ 135℉ |
Power | 45W | Durability | 2 million times |
Voltage output of door lock
control| DC 12V| Package dimension| 16126 inches
Voltage output of light| DC 24V| Weight| 17.8 Lbs
3. INSTALLATION
For specific installation videos, please search for videos on Youtube
Hanchen How to Install Automatic Gate Opener
I. Preparation of tools and materials
Electric hammer (concrete column structure)
Electric drill (iron pipe and other structures)
Cross screwdriver
Wire stripping pliers
Cloth wrapping
Wrench
Power cord RVV2 × 1.5mm ²
Electric lock wire RVV2 × 1.5mm ²
Access control wire RVV4 × 1.0mm ²/Infrared anti pinch RVV4 × 1.0mm ² Or HSYV8
× 0.5mm ²
II. Determine the direction of opening the door
III. Gate structure
4. EQUIPMENT WIRING
5. EQUIPMENT DEBUGGING
I. Opening angle
F1: The higher the value, the greater the door opening angle. Setting range is 10-270(unit:°)
II. Remote control pairing
FA: Press the motherboard to FA, press “OK”, and the display screen will display “PPPP”. Press and hold the “Stop” button on the remote control until there is a “beep” sound indicating pairing has been finished.
III. Direction of open the door
F2: 0-1, 0 by default (left), 1 (right)
IV. Restore factory settings
FB: Press the motherboard to FB, press the “OK” button to display LdEF. Press and hold the “OK” button until the buzzer sounds 5 times, indicating initialization is finished.
V. Controller parameter – detailed table
F1| Angle| The larger the value, the greater the opening
angle| 10-270
---|---|---|---
F2| Direction| 0: Open the door to the left
1: Open the door to the right| 0 or 1
F3| Opening speed| The higher the value, the faster the door opening speed|
2-100
F4| Closing speed| The higher the value, the faster the door closing
speed| 2-100
F5| Closing time delay| Delay the closing time after the door is opened in
place| 0-7000
F6| Resistance of rebound strength| The higher the value, the greater
the resistance force required to rebound| 6-70
F7| Resistance of rebound
sensitivity| The higher the value, the longer the resistance
time is required to rebound| 1-30
F9| F9:A| Polarity of access signal| 0: Indicates that the low level
(connected to COM) is valid
1: Active high level (voltage 3.3~12V)
Note: Generally, this parameter should be set to 1 for face recognition of
Hikvision
. After setting, it can take effect only after power
failure and restart| 0 or 1
F9:B| Closing
acceleration| The higher the value, the faster the closing
acceleration phase accelerates| 1-20
F9:C| Closing speed reduction| The larger the value is, the faster the
deceleration will be in the closing deceleration stage. Too large the
value may lead to louder impact sound when the closing is in place.| 1-20
| F9:D| Magnetic lock selection| 0: Normal magnetic lock
1: Positive electric plug lock (power off lock pin out)
2: Negative plug lock Power plug lock out| 0-2
FA| Wireless remote control pairing| Press and hold the “Stop” button on
the remote control until there is a “beep” sound. And it indicates
the machine pairing is finished| PPPP
FB| Parameter initialization| Press and hold the “OK” key until the buzzer
rings 5 times, indicating that the parameter has been initialized.
Note: F2 opening direction, FF:E motor type, these two parameters
will not be initialized but
retain the user set values| LdEF
FC| Automatic running| 1: Periodically close the door and open the door for a
long time to test the door| 0 or 1
FE| FE:4| Manually push the door to set the opening position| When the origin
is found after power-on and the door is closed in place, the magnetic lock
will be disconnected after entering this menu, and then you can
manually open the door to the required position and press “OK” to
set the current position as the position to open the door.| –
FE:5| Clear remote control| Press and hold the “OK” key, hear 5 buzzer
sound, clear all of the saved remote control code data|
FF| FF:3| Opening
acceleration| The higher the value, the faster the opening
speed| 1-100
---|---|---|---|---
FF:4| Opening speed reduction| The higher the value, the faster
the door decelerates| 1-100
FF:b| Encounter resistance of rebound dead zone| When the door of the
resistance rebound dead zone, even if the resistance triggered, will
not rebound the door| 12-600
FH| FH:1.1| Opening position buffer| The larger the value, the smaller the
buffer, and
the smaller the value, the more obvious the buffer| 0-500
FH:1.2| Closing position buffer| The larger the value, the smaller the buffer,
and
the smaller the value, the more obvious the buffer| 0-500
FH:1.3| Opening position buffer ratio| The larger the value, the buffering
speed of the door opening position is faster.| 0-256
FH:1.4| Closing position buffer ratio| The larger the value, the buffering
speed of the door closing position is faster.| 0-256
6. TROUBLE SHOOTING
Fault code | Fault information | Cause analysis | Treatment measures |
---|---|---|---|
0E+00 | Internal error | Internal error | Return to controller manufacturer |
0E+00 | The following error exceeds the limit | 1. The actual motor model does | |
not match the controller motor model | Select the matching motor model or |
replace the motor through the menu FF:E
2. The motor outlet shaft and the reducer are disconnected| Check mechanical
structure
0E+00| Hall signal of motor is faulty| 1. Hall wire of the motor is not
connected or one of the wires is disconnected| Check the condition of hall
line
2. The hall plate of the motor is faulty| Return to the motor manufacturer
for repair
0E+00| Motor overload| 1. The motor is overloaded| Check whether the machine
is
stuck
2. The output capacity of motor
is too small| Replacement motor
3. The actual motor model does
not match the controller motor model| Select the matching motor model
or replace the motor through the menu FF:E
0E+00| Controller temperature is too high.| 1. The controller is surrounded
by heat sources, such as a fan| Avoid heat
2. The load continues to be too heavy and the output power of the motor is
too large| Check the mechanical structure and replace the motor
3. The temperature sensor inside the controller is faulty| Return to the
controller manufacturer for repair
0E+00| Oversupply voltage| The switching power supply is abnormal and the
output voltage is too high| Replace switching power supply
0E+00| The power supply voltage is too low| 1. The switching power supply is
abnormal and the output voltage is too low| Replace switching power supply
2. The power of the switching power supply is too small| Replace a larger
switching power supply. It is recommended that the output current
of the switching power supply be greater than 7A
3. The cable between the switching power supply and the controller is too
long, causing a voltage drop on the power cable| Reduce line length , use a
wire with a thicker core and raise the output voltage of the switching
power supply
4. The power cable is improperly connected to the terminal| Recontact well
0E+00| Control panel short circuit| 1. The motor wire is broken and short
connected with the shell and
other wires| Replace the motor cable
2. Motor burned out internal short circuit| Return to the motor manufacturer
for repair
3. The power tube of the controller is burned down| Return to the controller
manufacturer for repair
7. PACKAGE LIST
Serial number | name | quantity | remarks |
---|---|---|---|
1 | Gate opener | 1 | pc |
2 | Arm | 1 | pc |
3 | screw package | Installation Sticker 1:1 | 1 |
4 | Screw Post | 1 | set |
5 | M8*80 Expansion screws | 4 | pcs |
6 | M8*18 Hexagon socket screw | 4 | pcs |
7 | Hexagon wrench | 1 | pc |
8 | Cross tapping screws | 22 | pcs |
9 | Small iron sheet for the top of gate opener | 1 | pc |
11 | User manual | 1 | pc |
12 | Remote control | 2 | pcs |
13 | 24V DC power supply | 1 | pc |
14 | Metal surface installation conversion board | 2 | pcs |
Frequently Asked Questions (FAQ)
Q: Is the gate opener suitable for heavy doors?
A: The gate opener is designed for doors weighing up to 550 Lbs.
Q: What is the remote control distance?
A: The remote control distance is 49 ft, providing convenient operation from a distance.
Q: How do I handle equipment malfunctions?
A: In case of malfunctions, cut off the power supply first and then proceed with troubleshooting after ensuring safety measures.
Read User Manual Online (PDF format)