Specifications

  • Applicable door width: 11.8 ft
  • Applicable door weight: 550 Lbs
  • Input voltage: DC 24V
  • Power: 45W
  • Voltage output of door lock control: DC 12V
  • Voltage output of light: DC 24V
  • Remote control distance: 49 ft
  • Motor speed ratio: 1200
  • Temperature: -40 ~ 135 degrees Fahrenheit
  • Durability: 2 million times
  • Package dimension: 16126 inches
  • Weight: 17.8 Lbs

1. SAFETY WARNING

I. Installation warning
1. Before installation, please carefully read the user manual and precautions, and then carry out assembly, installation, and debugging operations to avoid unnecessary losses.
2. All installation, debugging, and maintenance work must be carried out with the main power supply disconnected.
3. The controller power supply must have safety grounding measures.
4. Please be careful when touching this product during installation to avoid collision, squeezing, falling to the ground, or coming into contact with any liquid. This product should be placed away from high temperatures and open flames.
5. The controller of this product is controlled by 24V low voltage, please do not directly connect to 110V high voltage.

II. Operation warning
1. This product is not suitable for use by children, people with disabilities, or those who without basic knowledge and experience, unless accompanied by professional trained people who be responsible for their safety.
2. During equipment debugging, it is important to keep children or elderly people away from the site to avoid accidental injuries caused by excessive force during debugging errors.

III. Maintenance warning

1. When the equipment malfunctions, please cut off the power supply of the equipment first and then disassemble it to check the problem.
2. When checking the support arm, please be sure to place a no pass sign to prevent the folding arm from squeezing the hands of maintenance personnel and avoiding accidents.

2. PRODUCT INTRODUCTION

I. Introduction
The automatic door opener is designed for automatic control of single or double iron gates, villa doors, glass doors, electric small doors, and pedestrian walkway swing doors. It can be opened and closed automatically through access control devices, facial recognition devices, mobile phones, and license plate recognition devices. The driving motor adopts a new type of brushless DC motor, with sufficient and stable force. The controller adopts military motherboard technology, providing a more user-friendly operating experience.

II. Feature
Compact: Especially suitable for pedestrian passage doors, it can also be installed on 5cm wide small door pillars Safety: irreversible motor, reverse arm, built-in closing limit (when using a complete curved arm)
Practical: Small curved arms are suitable for installation under various special conditions, such as small door pillars or small installation spaces
Fast: No need to wait, the fastest time to turn on or off is only 3 seconds (in ideal conditions, use a shortened curved arm to open 90 °)
Soft start and soft stop function, greatly protecting motor gears and extending product service life

III. Parameter

Applicable door width <11.8 ft Remote control distance >49 ft
Applicable door weight <550 Lbs Motor speed ratio 1:200
Input voltage DC 24V Temperature -40℉ ~ 135℉
Power 45W Durability 2 million times

Voltage output of door lock
control| DC 12V| Package dimension| 16126 inches
Voltage output of light| DC 24V| Weight| 17.8 Lbs

3. INSTALLATION

For specific installation videos, please search for videos on Youtube
Hanchen How to Install Automatic Gate Opener

I. Preparation of tools and materials

Electric hammer (concrete column structure)
Electric drill (iron pipe and other structures)
Cross screwdriver
Wire stripping pliers
Cloth wrapping
Wrench
Power cord RVV2 × 1.5mm ²
Electric lock wire RVV2 × 1.5mm ²
Access control wire RVV4 × 1.0mm ²/Infrared anti pinch RVV4 × 1.0mm ² Or HSYV8 × 0.5mm ²

II. Determine the direction of opening the door

Determine

III. Gate structure

Gate structure

4. EQUIPMENT WIRING

EQUIPMENT WIRING

5. EQUIPMENT DEBUGGING

EQUIPMENT DEBUGGING

I. Opening angle

F1: The higher the value, the greater the door opening angle. Setting range is 10-270(unit:°)

II. Remote control pairing

FA: Press the motherboard to FA, press “OK”, and the display screen will display “PPPP”. Press and hold the “Stop” button on the remote control until there is a “beep” sound indicating pairing has been finished.

III. Direction of open the door

F2: 0-1, 0 by default (left), 1 (right)

IV. Restore factory settings

FB: Press the motherboard to FB, press the “OK” button to display LdEF. Press and hold the “OK” button until the buzzer sounds 5 times, indicating initialization is finished.

V. Controller parameter – detailed table

F1| Angle| The  larger  the  value,  the  greater  the  opening
angle| 10-270
---|---|---|---
F2| Direction| 0: Open the door to the left
1: Open the door to the right| 0 or 1
F3| Opening speed| The higher the value, the faster the door opening speed| 2-100
F4| Closing speed| The higher the value, the faster the door closing
speed| 2-100
F5| Closing time delay| Delay the closing time after the door is opened in
place| 0-7000
F6| Resistance of rebound strength| The  higher  the  value,  the  greater the  resistance force required to rebound| 6-70
F7| Resistance of rebound
sensitivity| The  higher  the  value,  the  longer  the  resistance
time is required to rebound| 1-30
F9| F9:A| Polarity of access signal| 0:  Indicates  that  the  low  level (connected  to COM) is valid
1: Active high level (voltage 3.3~12V)
Note: Generally,  this parameter should be set to 1 for face recognition of Hikvision
. After setting, it can take effect only after power
failure and restart| 0 or 1
F9:B| Closing
acceleration| The higher the value, the faster the closing
acceleration phase accelerates| 1-20
F9:C| Closing speed reduction| The larger the value is, the faster the deceleration will  be  in  the  closing  deceleration  stage.  Too large the value may lead to louder impact sound when the closing is in place.| 1-20
| F9:D| Magnetic lock selection| 0: Normal magnetic lock
1: Positive electric plug lock (power off lock pin out)
2: Negative plug lock Power plug lock out| 0-2
FA| Wireless remote control pairing| Press and  hold  the  “Stop” button  on the  remote control  until  there  is  a  “beep”  sound.  And  it indicates the machine pairing is finished| PPPP
FB| Parameter initialization| Press and hold the “OK” key until     the buzzer rings  5  times,  indicating  that  the  parameter  has been initialized.
Note:  F2  opening  direction,  FF:E  motor  type, these  two  parameters will  not  be  initialized  but
retain the user set values| LdEF
FC| Automatic running| 1: Periodically close the door and open the door for a long time to test the door| 0 or 1
FE| FE:4| Manually push the door to set the opening position| When the origin is found after power-on and the door is closed in place, the magnetic lock will be disconnected  after  entering  this  menu,  and  then you can manually open  the door  to the required position   and   press   “OK”   to set   the   current position as the position to open the door.| –
FE:5| Clear remote control| Press  and  hold  the  “OK”  key,  hear  5  buzzer sound, clear all of the saved remote control code data|
FF| FF:3| Opening
acceleration| The  higher  the  value,  the  faster  the  opening
speed| 1-100
---|---|---|---|---
FF:4| Opening speed reduction| The   higher   the   value,   the   faster the   door decelerates| 1-100
FF:b| Encounter resistance of rebound dead zone| When  the  door  of  the resistance  rebound  dead zone,  even  if  the  resistance  triggered,  will not rebound the door| 12-600
FH| FH:1.1| Opening position buffer| The larger the value, the smaller the buffer, and
the   smaller   the   value,   the   more   obvious   the buffer| 0-500
FH:1.2| Closing position buffer| The larger the value, the smaller the buffer, and
the   smaller   the   value,   the   more   obvious   the buffer| 0-500
FH:1.3| Opening position buffer ratio| The larger the value, the buffering speed of the door opening position is faster.| 0-256
FH:1.4| Closing position buffer ratio| The larger the value, the buffering speed of the door closing position is faster.| 0-256

6. TROUBLE SHOOTING

Fault code Fault information Cause analysis Treatment measures
0E+00 Internal error Internal error Return to controller manufacturer
0E+00 The following error exceeds the limit 1.  The actual motor model does
not match the controller motor model Select the matching motor model or

replace the motor through the menu FF:E
2.  The motor outlet shaft and the reducer are disconnected| Check mechanical structure
0E+00| Hall signal of motor is faulty| 1.  Hall wire of the motor is not connected or one of the wires is disconnected| Check the condition of hall line
2.  The hall plate of the motor is faulty| Return to the motor manufacturer for repair
0E+00| Motor overload| 1.  The motor is overloaded| Check whether the machine is
stuck
2.  The output capacity of motor
is too small| Replacement motor
3.  The actual motor model does
not match the controller motor model| Select the matching motor model
or replace the motor through the menu FF:E
0E+00| Controller temperature is too high.| 1.  The controller is surrounded by heat sources, such as a fan| Avoid heat
2.  The load continues to be too heavy and the output power of the motor is too large| Check the mechanical structure and replace the motor
3.  The temperature sensor inside the controller is faulty| Return to the controller manufacturer for repair
0E+00| Oversupply voltage| The switching power supply is abnormal and the output voltage is too high| Replace switching power supply
0E+00| The power supply voltage is too low| 1.  The switching power supply is abnormal and the output voltage is too low| Replace switching power supply
2.  The power of the switching power supply is too small| Replace a larger switching power supply.  It  is  recommended  that the     output     current of     the switching     power     supply     be greater than 7A
3.  The cable between the switching power supply and the controller is too long, causing a voltage drop on the power cable| Reduce  line  length , use  a wire with a  thicker  core and raise  the output  voltage  of  the  switching power supply
4.  The power cable is improperly connected to the terminal| Recontact well
0E+00| Control panel short circuit| 1.  The motor wire is broken and short connected with the shell and
other wires| Replace the motor cable
2.  Motor burned out internal short circuit| Return to the motor manufacturer for repair
3.  The power tube of the controller is burned down| Return to the controller manufacturer for repair

7. PACKAGE LIST

Serial number name quantity remarks
1 Gate opener 1 pc
2 Arm 1 pc
3 screw package Installation Sticker 1:1 1
4 Screw Post 1 set
5 M8*80 Expansion screws 4 pcs
6 M8*18 Hexagon socket screw 4 pcs
7 Hexagon wrench 1 pc
8 Cross tapping screws 22 pcs
9 Small iron sheet for the top of gate opener 1 pc
11 User manual 1 pc
12 Remote control 2 pcs
13 24V DC power supply 1 pc
14 Metal surface installation conversion board 2 pcs

Automatic-Gate-Opener

Frequently Asked Questions (FAQ)

Q: Is the gate opener suitable for heavy doors?

A: The gate opener is designed for doors weighing up to 550 Lbs.

Q: What is the remote control distance?

A: The remote control distance is 49 ft, providing convenient operation from a distance.

Q: How do I handle equipment malfunctions?

A: In case of malfunctions, cut off the power supply first and then proceed with troubleshooting after ensuring safety measures.