ZENDURE ZDSMCT Satellite Monitor CT Instruction Manual

June 17, 2024
ZENDURE

ZENDURE ZDSMCT Satellite Monitor CT

Specifications

  • Name: Satellite Monitor CT
  • Model : Not specified
  • Weight: Not specified
  • Dimensions: Not specified
  • Rated System Voltage : Not specified
  • Frequency : Not specified
  • Consumption: Not specified
  • Max Measurement per Channel : Not specified
  • Protection Level: Not specified
  • Operating Temperature : Not specified
  • Storage Temperature: Not specified
  • Operating Humidity (RH): Not specified
  • Max Operating Altitude : Not specified
  • Wireless Type : Not specified

Product Usage Instructions

Before You Begin

The information contained herein is subject to change without notice. For the latest version, please visit Zendure Download Center.

Safety Instructions

  • The product should be installed by a qualified person (electrician).
  • Check for any damages or cable issues before operating.
  • Avoid unauthorized personnel from replacing internal components.
  • Follow the user manual for installation to prevent injury or damage.
  • Ensure input power is disconnected before installation.
  • Avoid outdoor installation or exposure to elements.

Product Features

What’s in The Box

  • Monitor IoT Antenna
  • 150A CT x1 x 2
  • Mounting kit
  • AC Power Cable
  • Installation Manual

Diagrams

  • IoT Antenna: For wireless communication.
  • IoT Indicator: Green light flashes while pairing.
  • REV Indicator: Indicates reverse power to grid.
  • RUN Indicator: Function not specified.
  • IoT/Reset Button: Pair/connect to Wi-Fi network, factory reset option.
  • CT1 Input, CT2 Input, AC Power Input: Connection ports.

Installation

Step 1 – Turn off the main breaker and remove the cover

  1. Open the door to the electrical panel and turn off the main breaker.
  2. Remove the screws and the panel cover.

Step 2 – Find a place for the Satellite Monitor CT

Using the Mounting Kit provided, install the Satellite Monitor CT beside the electrical panel or inside if there is no outlet available (using appropriate procedures).

Step 3 – Clamp the CT sensor around the service main

Clamp the CT sensor around the service main. Note the direction of energy flow (grid to home). If using three-phase power and other Zendure products, follow specific instructions.

FAQ

  • Q: Can I install the Satellite Monitor CT myself?
  • A : The product should be installed by a qualified electrician to ensure safety and proper installation.
  • Q: What do I do if I notice damage to the Satellite Monitor CT?
  • A: If you notice any damage or cable issues, stop using the product immediately and contact Zendure support for assistance.
  • Q : How do I pair the Satellite Monitor CT with a Wi-Fi network?
  • A : Press and hold the IoT/Reset Button for 3 seconds to pair and connect to a Wi-Fi network.

DISCLAIMER

The ZENDURE Satellite Monitor CT should be installed by a qualified person (electrician), who should be familiar with all electrical codes, and electrical wiring practices and with experience working with home electrical systems. Any accident, damage or injury caused by incorrect installation is the sole responsibility of the user. Read all safety instructions and other product information in this manual carefully, and read any labels or stickers attached to the product before using it. Users take full responsibility for the safe usage and operation of this product. Familiarize yourself with relevant regulations in your area. You are solely responsible for being aware of all relevant regulations and using Zendure products in a way that is compliant. Keep this manual for future reference.

Before You Begin

The information contained herein is subject to change without notice. For the latest version, please visit https://zendure.com/pages/download-center

Specifications

Satellite Monitor CT is an IoT-powered electricity meter. It allows you to simultaneously monitor the consumption of any household appliances, circuits and office equipment in single-phase electrical systems. It is perfect for monitoring household consumption, as well as tracking how much energy your solar panels are producing and controlling SolarFlow and AIO output to household appliances. Zendure Satellite Monitor CT does not support a parallel feed configuration or comprehensive three-phase monitoring, however if your household uses three-phrase electricity, it can monitor one phase in that system.

Name Satellite Monitor CT
Model ZDSMCT
Weight ≈ 181g
Dimensions 140 x 35 x 77mm
Rated System Voltage 100 ~ 240VAC ±10%
Frequency 50/60Hz
Consumption < 1.1W
Max Measurement per Channel 150A
Protection Level IP44
Operating Temperature -20 ~ 70℃
Storage Temperature -40 ~ 85℃
Operating Humidity (RH) 5 ~ 95%
Max Operating Altitude 3000 M
Wireless Type

Safety Instructions

  1. The product should be installed by a qualified person (electrician).
  2. Please check whether Satellite Monitor CT is damaged, cracked, or cables are damaged before operating. If so, please stop using the product immediately and contact Zendure support.
  3. Do not attempt to replace the internal components of the equipment by any unauthorized personnel.
  4. Please install the product according to the user manual to avoid injury or damage to the product.
  5. Ensure that the input power is disconnected before installation.
  6. Do not install or operate the product outdoors or expose to moisture or submerge it in liquid. Only clean the ports with a dry cloth.
  7. Do not use the product if it is damaged or appears to be damaged. Do not disassemble the product. Consult official Zendure channels when service or repair is required. Incorrect disassembly or reassembly may result in a risk of fire or injury to persons.
  8. Adhere to all local and national safety regulations for installation and use. This product is designed for residential use only.
  9.  Keep out of reach of children and pets.

Product Features

What’s in The Box

ZENDURE-ZDSMCT- Satellite-Monitor-CT-FIG-1

Diagrams

ZENDURE-ZDSMCT- Satellite-Monitor-CT-FIG-2

  1. IoT Antenna
  2. IoT Indicator The green light flashes while pairing and will stay lit when the device is paired.
  3. REV Indicator Indicates reverse power to the grid.
  4. RUN Indicator
  5. IoT/Reset Button Press the button for 3 seconds to pair and connect to a Wi-Fi network, and press and hold for 10 seconds to factory reset.
  6. CT1 Input
  7. CT2 Input
  8. AC Power Input

Installation

  • Step 1 Turn off the main breaker and remove the cover Open the door to the electrical panel and turn off the main breaker. Remove the screws and the panel cover.

  • Step 2ZENDURE-ZDSMCT- Satellite-Monitor-CT-FIG-4
    Find a place for the Satellite Monitor CT Using the Mounting Kit provided, install the Satellite Monitor CT beside the electrical panel or inside if there is no outlet available (using appropriate procedures).

  • Step 3ZENDURE-ZDSMCT- Satellite-Monitor-CT-FIG-5
    Clamp CT sensor around service main Clamp the CT sensor around the service main. Note the K L direction of energy flow (grid to home). If the installation site uses three-phase power and you have a Zendure SolarFlow or Zendure AIO, clamp the CT sensor around the same phase as those products.

  • Step 4
    Connect the AC power cord to the grid single-phase socket
    Plug the power harness into the Satellite Monitor CT AC power input connection until it snaps into place. Then connect the harness plug to a single-phase power outlet.

  • Step 5ZENDURE-ZDSMCT- Satellite-Monitor-CT-FIG-7
    Close the cover and turn on all breakers Secure the cover to the box with the screws and turn power on. Confirm the Satellite Monitor CT powers on, then close the door to the electrical panel.

  • Step 6

Download the Zendure app
Please read the Zendure app user guide and download the app using the QR code above or by visiting https://zendure.com/pages/download-center

Privacy Policy
By using Zendure Products, Applications and Services, you consent to the Zendure Terms of Use and Privacy Policy, which you can access via the “About” section of the “User” page in the Zendure App.ZENDURE-ZDSMCT- Satellite-
Monitor-CT-FIG-9

Warranty

This product carries a two-year warranty from the purchase date. Please feel free to contact us if you have any product questions or suggestions.

Customer Service Email:
support@zendure.com

CONTACT

  • Zendure USA Inc.
  • ZENDURE TECHNOLOGY CO., LIMITED Hours: Mon – Fri 9:00 – 17:00
  • Pacific Phone: 1-800-991-6148 (US)
  • +49-800-627-3067 (DE)

Support / Contact:

© 2023 Zendure USA Inc. All Rights Reserved. Printed on recycled materials. MADE IN CHINA

ZENDURE-ZDSMCT- Satellite-Monitor-CT-FIG-10

References

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>

Related Manuals