SHURE MXA902 Integrated Conferencing Ceiling Array Instruction Manual

June 17, 2024
Shure

Table of Contents

SHURE MXA902 Integrated Conferencing Ceiling Array

Product Information

Specifications

  • Model: MXA902 Integrated Conferencing Ceiling Array

  • Manufacturer: Shure Incorporated Frequency Response: Detailed specifications
    available in the user manual

  • Dimensions: Detailed dimensions are available in the user manual

Product Usage Instructions

Getting Started

MXA902 Designer Setup

  1. Install the MXA902 and connect it to a PoE+ port on the network switch using an Ethernet cable.
  2. If your switch doesn’t supply PoE+, the loudspeaker does not play sound and the error LED flashes.
  3. Connect the computer running Designer to the same network.
  4. Open Designer and check that you’re connected to the correct network in Settings.
  5. Go to Online devices. To identify devices, click the product icon to flash the lights on a device. Find the MXA902 in the list.
  6. Check if there are firmware updates available for the MXA902 and install the latest. You can also use Shure Update Utility.

Route Audio and Apply DSP
The easiest way to route audio and apply DSP is with the Designer’s optimized workflow. Optimize routes audio signals, apply DSP settings, turns on mute synchronization, and enables LED control for connected devices.

Example: Connecting an MXA902 and an ANIUSB-MATRIX

  1. In Designer, create a new room.
  2. Drag and drop the MXA902 and the ANIUSB-MATRIX to add them to the room.

Installation
Install in a Ceiling Grid Detailed installation instructions for mounting in a ceiling grid are available in the user manual.

VESA Standardized Mounting Instructions for VESA standardized mounting are provided in the user manual for reference.

FAQ

Q: How do I troubleshoot issues with the MXA902?
A: Refer to the Troubleshooting section in the user manual for detailed steps on resolving common issues with the MXA902.

User guide for Shure MXA902 integrated ceiling array microphone, loudspeaker, and IntelliMix DSP. Learn how to install and get great audio in small/medium rooms Version: 0.2 (2023-H)

MXA902 Integrated Conferencing Ceiling Array

Getting Started

MXA902 Designer Setup
The MXA902 microphone and loudspeaker intelligently covers all talkers inside the 20 x 20-foot (6.1 x 6.1 m) coverage area. IntelliMix DSP sends a clear signal for the far end, with AEC, noise reduction, and more on a single output. The loudspeaker provides high-quality speech reproduction for the entire 20 x 20-foot (6.1 x 6.1 m) coverage area. After completing this basic setup process, you should be able to:

  • Discover the MXA902 in Designer
  • Adjust DSP settings, route audio, and change loudspeaker levels

You will need:

  • Cat5e or better Ethernet cable (shielded cable recommended)
  • Network switch that provides Power over Ethernet Plus (PoE+)
  • Shure Designer software (download at shure.com/designer)

Step 1: Install and Connect

  1. Install the MXA902 and connect it to a PoE+ port on the network switch using Ethernet cable. If your switch doesn’t supply PoE+, the loudspeaker does not play sound and the error LED flashes.
  2. Connect the computer running Designer to the same network.
  3. Open Designer. Check that you’re connected to the correct network in Settings.
  4. Go to Online devices. To identify devices, click the product icon to flash the lights on a device. Find the MXA902 in the list.
  5. Check if there are firmware updates available for the MXA902 and install the latest. You can also use Shure Update Utility (download at shure.com/suu).

Step 2: Route Audio and Apply DSP
The easiest way to route audio and apply DSP is with Designer’s optimize workflow. Optimize routes audio signals, applies DSP settings, turns on mute synchronization, and enables LED control for connected devices. For this example, we’ll connect an MXA902 and an ANIUSB-MATRIX.

  1. In Designer, create a new room. Drag and drop the MXA902 and the ANIUSB-MATRIX to add them to the room.
  2. Select Optimize. Designer sends the microphone signal to the ANIUSB-MATRIX, sets the MXA902’s loudspeaker as the AEC reference, and makes other DSP changes. You can also route audio manually in Designer or Dante Controller.
  3. Check the audio routes and settings to make sure they fit your needs.

Step 3: Listen and Adjust

  1. Connect a computer with videoconferencing software (such as Zoom or Microsoft Teams) installed on it to the ANIUSB-MATRIX’s USB port.
  2. Open the ANIUSB­MATRIX’s matrix mixer in Designer. Make sure that the box where the Dante input and the USB out­put intersect is checked (this sends the microphone signal to the computer).
  3. Open the videoconferencing software on the computer connected to the ANIUSB-MATRIX. In the settings, choose the ANIUSB-MATRIX as the speaker and microphone.
  4. Place a test call with the whole system. Have the far-end caller tell you how the microphone signal sounds and make adjustments as needed:
    • ◦ Microphone: [Your room] > MXA902 > IntelliMix
    • Loudspeaker: [Your room] > MXA902 > Loudspeaker > Speaker output.
  5. If needed, move the microphone’s coverage area up to 4 feet (1.2 m) in any direction: [Your room] > Coverage map. You can also listen to the microphone signal directly using a Dante headphone amp to help make adjustments.

Important : Use Designer 4.7.25 or newer to discover the MXA902. Refer to MXA902 Limitations for details about using the MXA902 with Designer 4.7.25 and certain Shure device firmware.

MXA902 Web Application Setup

Out of the box, the MXA902 has a 20 x 20-foot (6.1 x 6.1 m) coverage area for microphone pickup and speech reproduction. You can shift the microphone coverage up to 4 feet (1.2 m) in any direction using Designer or the web application. After com­pleting this basic setup process, you should be able to:

  • Access the MXA902’s web application
  • Adjust DSP settings, route audio, and change loudspeaker levels

You will need:

  • Cat5e (or better) Ethernet cable
  • Network switch that provides Power over Ethernet Plus (PoE+)
  • Shure Web Device Discovery and Dante Controller software

Step 1: Install and Connect

  1. Install the microphone and connect it to a PoE+ port on the network switch using an Ethernet cable.
  2. Connect the computer running Shure Web Device Discovery and Dante Controller to the same network.
  3. Open Shure Web Device Discovery. Find the MXA902 in the list of devices and double­click to open the web applica­tion.

Step 2: Route Audio
To route audio to and from other Dante devices, use Dante Controller.

  1. Open Dante Controller and find the MXA902 in the list of transmitters and receivers.
  2. Find the Dante device you’re sending the MXA902’s microphone signal to in the list of receivers. To make an audio route, check the box where the MXA902’s automix output intersects with the receiver device’s input channel.
  3. To route far-end audio to the MXA902’s loudspeaker, check the box where the transmitter device’s channel intersects with one of the MXA902’s 2 Dante input channels in the receiver list. The 2 inputs are summed and sent to the loud­speaker (the loudspeaker signal is also set as the AEC reference).
  4. In your videoconferencing software, make sure to select the correct microphone and loudspeaker sources.

Step 3: Listen and Adjust

  1. Place a test call with the whole system. Have the far-end caller tell you how the microphone signal sounds and make adjustments in the web application as needed:
    • Microphone: MXA902 web application > IntelliMix
    • Loudspeaker: MXA902 web application > Loudspeaker > Speaker output.
  2. If needed, move the microphone’s coverage area up to 4 feet (1.2 m) in any direction: MXA902 web application > Coverage map. You can also listen to the microphone signal directly using a Dante headphone amp to help make ad­justments.

General Description

The Microflex Advance™ MXA902 Integrated Conferencing Ceiling Array delivers premium audio capture and reproduction for small­ to medium­sized meeting spaces—with virtually no setup required. It combines an advanced array microphone with an integrated loudspeaker for natural-sounding speech reproduction. Features Single-Zone Automatic Coverage™ technology to capture audio from a 20 by 20-foot (6 by 6 meter) area and onboard IntelliMix DSP for echo- and noise-free audio. Paintable white finish; versatile mounting options.

Features

  • Array microphone and loudspeaker in one unit for premium sound with minimal installation time
  • Single-Zone Automatic Coverage technology to capture audio from a 20 by 20-foot (6 by 6 meter) area out of the box Integrated 2.5-inch wide-dispersion loudspeaker for clear, intelligible speech reproduction
  • Onboard IntelliMix DSP with acoustic echo cancellation, noise reduction, automatic mixing, AGC, and EQ for echo- and noise-free audio
  • Square form factor available in 24-inch or 60-cm sizes with paintable white finish
  • Versatile options for ceiling, pole, or wire rope suspension mounting
  • Shure Designer System Configuration software for easy setup and configuration
  • PoE+ powered
  • LED status bar with configurable colors and brightness
  • Dante & AES67 audio networking protocols

MXA902 Parts

SHURE-MXA902 -Integrated -Conferencing -Ceiling-Array-fig-
\(4\)

  1. Mute status LED
    The device mute button in Designer or the web application changes the mute status LED. Customize LED color and behavior in Designer: Device configuration

    Settings > Lights.
    Mute Status LED Default Settings** Microphone Status| LED Color/Behavior
    ---|---
    Active| Green (solid)
    Muted| Red (solid)
    Hardware identification| Green (flashing)
    Firmware update in progress**| Green (progresses along bar)

Reset

| Network reset: Red (progresses along bar)

Factory reset: Triggers device power-up

Error| Red (split, alternate flashing)
Microphone Status| LED Color/Behavior
---|---

Device power-up

| Multi-color flash, then blue (moves quickly back and forth across bar)

Note : If LEDs are disabled, they will still turn on when the device powers up or when an error state occurs.

  1. Reset button
  2. RJ-45 network port
  3. Network status LED (green)
    • Off = No network link
    • On = Network link established
    • Flashing = Network link active
  4. Network speed LED (amber)
    • Off = 10/100 Mbps
    • On = 1 Gbps
  5. Eyelet screws for suspension mounting (12 mm diameter)
  6. VESA MIS-D mounting holes (100 mm spacing)
  7. Safety tether attachment points
  8. Loudspeaker enclosure

Power Over Ethernet Plus (PoE+)

This device requires PoE Plus (PoE+) to operate. It is compatible with Class 4 PoE+ sources. PoE+ is delivered in one of the following ways:

  • A network switch that provides PoE+
  • A PoE+ injector device (must be a gigabit device)

Note : When connected to a PoE source, the MXA902 works as a microphone but not as a loudspeaker. The red error LED also flashes. To dismiss, connect to a PoE+ source to turn on the loudspeaker or go to Settings > Lights to clear the error.

Model Variations

SKU Description
MXA902W- S White square microphone with loudspeaker
MXA902W-S- 60CM White square microphone with loudspeaker (60 cm)

Optional Accessories and Replacement Parts

  • A900-S-GM Gripple Mount Kit, Square
  • A900-S-PM Pole Mount Kit, Square
  • A900-PM-3/8IN Threaded Rod Adapter Mounting Kit A910-JB Junction Box Accessory
  • A900-CM Ceiling Mount
  • RPM904 frame and grille assembly
  • RPM901W-US frame and grille assembly

Note : Shure’s A910-25MM accessory doesn’t fit the MXA902.

What’s in the Box

Square array microphone with loudspeaker MXA902-S or MXA902-S-60CM

Hardware kit with:

Cable ties (8) Strain relief tabs (3) Rubber pad set

|

90A49117

Reset Button

The reset button is behind the grille with a silkscreened circle around it. To push it, use a paper clip or other tool. You can also reset the device using the control software.

Reset Modes

  • Network reset (press for 4-8 seconds): Resets all Shure control and audio network IP settings to factory defaults. Red LED along bar.
  • Full factory reset (press for more than 8 seconds): Resets all network and configuration settings to the factory defaults. Multicolor flash, then blue LED along bar.

MXA902 Control Software

There are 2 ways to control the MXA902:

  • Use Shure Designer software (download at shure.com/designer)
    • Control all Shure devices in one place.
    • Route audio to and from Shure devices.
  • Open the MXA902’s web application with Shure Web Device Discovery (download at shure.com)
    • Control 1 device at a time.
    • Route audio with Dante Controller software.

To update firmware, use Designer or Shure Update Utility (download at shure.com/suu).

Controlling Devices with Shure Designer Software

To control this device’s settings, use Shure Designer software. Designer enables integrators and system planners to design au­dio coverage for installations using MXA microphones and other Shure networked devices.

To access your device in Designer:

  • Download and install Designer on a computer connected to the same network as your device.
  • Open Designer, and check that you’re connected to the correct network in Settings.
  • Click Online devices. A list of online devices appears.
  • To identify devices, click the product icon to flash the lights on a device. Select your device in the list and click Config­ure to control device settings.

Learn more at shure.com/designer.You can also access device settings using Shure Web Device Discovery.

How to Update Firmware Using Designer

Applies to Designer 4.2 and newer. Before setting up devices, check for firmware updates using Designer to take advantage of new features and improvements. You can also install firmware using Shure Update Utility for most products.

To update:

  1. Open Designer. If there’s new firmware that you haven’t downloaded yet, the Designer shows a banner with the number of updates available. Click to download firmware.
  2. Go to Online devices and find your devices.
  3. Choose a firmware version for each device from the Available firmware column. Make sure that no one is editing device settings during an update.
  4. Select the checkbox next to each device you plan to update and click Update firmware. Devices may disappear from Online devices during an update. Don’t close Designer while updating firmware.

MXA902 Coverage

The MXA902 uses Single-Zone Automatic Coverage technology. There is one 20 x 20-foot (6.1 x 6.1 m) coverage area that captures every talker in it with minimal configuration. The MXA902’s integrated loudspeaker provides natural- sounding speech reproduction for the entire coverage area. To access microphone coverage settings:

  • Designer: Add the microphone to a room and go to the Coverage map.
  • Web application : Go to Coverage.

Any talker in the blue coverage area has microphone coverage. Click and drag to move the coverage area up to 4 feet (1.2 m) in any direction.

The MXA902 provides 1 automated output with IntelliMix DSP for the far end. For most rooms, all you need to do is install the microphone above the coverage area and route the audio signal using Shure Designer software or Dante Controller.

How Much Space Does the MXA902 Cover?

The MXA902’s microphone coverage area is set at 20 x 20 feet (6.1 x 6.1 m). For most rooms, Shure recommends:

  • Maximum distance from talker to microphone: 16 feet (4.9 m)
  • Maximum mounting height: 10 feet (3 m)

The maximum distance from talker to microphone and maximum mounting height also depend on your room’s acoustics, con­struction, and materials. Acoustically treated rooms that are less reverberant generally sound better and help improve your mi­crophone signal. The MXA902’s loudspeaker delivers high-quality speech reproduction for the entire 20 x 20-foot (6.1 x 6.1 m) coverage area.

Adjust Microphone and Loudspeaker Levels

To adjust levels, open the MXA902 in Designer or the device web application.

Microphone Levels
To adjust, go to IntelliMix.

  1. Make a test call with your videoconferencing software.
  2. Talk in all parts of the coverage area at a normal speech volume and have someone on the far end listen to your signal. Adjust levels as needed. The coverage area gain fader is post-gate.
  3. Adjust EQ settings as needed. You can use EQ to improve speech intelligibility and control problematic frequencies in a room (such as a low-frequency rumble caused by HVAC systems). You can also make changes to IntelliMix DSP blocks here.
  4. If needed, listen to the microphone signal directly using a Dante headphone amp or with Dante Virtual Soundcard.

Loudspeaker Levels
To adjust, go to Loudspeaker and use the Speaker output fader.
Make a test call with your videoconferencing software and adjust the loudspeaker level as needed. If you set a higher loud­speaker level, you may need to use a higher NLP setting on the AEC block to remove echo.
If needed, use the signal generator to help with EQ adjustments. The signal generator is pre-EQ.

Mute the MXA902

The MXA902 has multiple mute points for controlling the microphone, the loudspeaker, or both:

SHURE-MXA902 -Integrated -Conferencing -Ceiling-Array-fig-
\(7\)

  1. IntelliMix output mute : Mutes the microphone’s Dante output channel
  2. Dante input mute: Mutes the selected Dante input channel
  3. Speaker output mute: Mutes the loudspeaker output
  4. Device mute: Mutes everything (microphone and loudspeaker). This mute button also changes the mute status LED.

Use Designer’s Optimize Workflow

Designer’s optimize workflow speeds up the process of connecting systems with at least 1 microphone and 1 audio processor. Optimize also creates mute control routes in rooms with MXA network mute buttons. When you select Optimize in a room, De­signer does the following:

  • Creates audio routes and mute control routes Adjusts audio settings
  • Turns on mute synchronization
  • Enables LED logic control for applicable devices

The settings are optimized for your particular combination of devices. You can customize settings further, but the optimize workflow gives you a good starting point. Optimize works with any device in Designer.

To use the optimized workflow:

  1. Place all relevant devices in a room.
  2. Select Optimize. Designer optimizes microphone and DSP settings for your equipment combination.

If you remove or add devices, select Optimize again. After optimizing a room, check and adjust settings to fit your needs. You may need to:

  • Delete unnecessary routes.
  • Check levels and adjust gain.
  • Check that AEC reference signals are correctly routed.
  • Fine-tune DSP blocks as needed.

Note : In the Routing view, a dotted line indicates a broken route that will not pass audio.

SHURE-MXA902 -Integrated -Conferencing -Ceiling-Array-fig-
\(8\)

Possible reasons:

  • Devices controlled by Dante Domain Manager (DDM).
  • Resolve the issues in DDM. Devices controlled by Dante device lock. Resolve the issues with Dante device lock.
  • Devices have mismatched encryption settings. Resolve the issues with encryption settings.
  • Devices have mismatched passphrases. Resolve the passphrase issue.
  • Devices located on different subnets. Resolve the issue by manually routing devices.

Hovering over devices provides additional information about the issue.

Important : Use Designer 4.7.25 or newer to discover the MXA902. Refer to MXA902 Limitations for details about using the MXA902 with Designer 4.7.25 and certain Shure device firmware.

How to Install the MXA902

There are many ways to install the MXA902 to get great coverage in small- to medium-sized meeting rooms.

Installation Best Practices

  • Don’t place the microphone behind obstructions.
  • Coverage depends on your room’s acoustics, construction, and materials. Take these into consideration when planning.
  • For most rooms, Shure recommends 10 feet (3 m) as the maximum mounting height.

Mounting options:

  • In a ceiling grid
  • With a VESA mounting device
  • On NPT pole
  • Suspend from ceiling with A900-GM Suspend from ceiling with your own hardware
  • On 3/8-inch threaded rod
  • Attach to ceiling with A900-CM

Install in a Ceiling Grid

Before you begin:

  • Remove the plastic cover from the grille.
  • Remove the cardboard piece between the loudspeaker and the back panel.
  • If using, install the rubber pads on the corners of the microphone to prevent scratches.
  • Verify that your ceiling grid size matches your model variation.
  • If using the A910-JB junction box, install it before ceiling installation.

IMPORTANT : Do not install the 60 cm model in a 2-foot (609.6 mm) ceiling grid.

  1. 1. Make space in the ceiling grid for the array microphone to be installed.
  2. Route the Ethernet cable above the ceiling grid and through the opening in the ceiling.
  3. Plug the Ethernet cable into the microphone.
  4. Attach the safety tether between the building structure and one of the tie-off points on the back of the microphone using braided metal cable or other high-strength wire (not included). This safety measure prevents the microphone from falling in an emergency situation. Make sure there is no tension on the safety tether. Follow any local regulations.
  5. Install the microphone in the ceiling grid.

SHURE-MXA902 -Integrated -Conferencing -Ceiling-Array-fig-
\(10\)

Notice

The MXA902­S­60CM is not designed or intended to be installed within a 24” ceiling grid, which is the standard grid size in North America. Mounting in such a grid in the above-shown configuration is unsafe and may cause damage to the product and/or injury to those below.

Installing the Junction Box Accessory

The A910­JB junction box mounts on square ceiling array microphones to connect conduit. There are 3 knockouts on the junc­tion box for attaching conduit. See local regulations to determine if the junction box is necessary.

Note : Install the junction box on the microphone before installing the microphone in the ceiling.

SHURE-MXA902 -Integrated -Conferencing -Ceiling-Array-fig-
\(12\)

To install:

  1. Remove the knockout you plan to use on the junction box.
  2. Remove the 4 screws from the microphone as shown.
  3. Align the junction box with the screw holes. If possible, plug the network cable into the microphone before securing the junction box.
  4. Reinstall the 4 screws to secure the junction box to the microphone.

VESA Standardized Mounting

SHURE-MXA902 -Integrated -Conferencing -Ceiling-Array-fig-
\(14\)

The rear plate has 4 threaded holes for attaching the microphone to a VESA mounting device. The mounting holes follow the VESA MIS-D standard:

  • Screw specification: M4 thread (hole depth = 9.15 mm)
  • Hole spacing: 100 mm square

The VESA mounting holes are compatible with these Shure accessories:

  • A900-PM
  • A900-PM-3/8IN
  • A900-CM

Suspending from the Ceiling

SHURE-MXA902 -Integrated -Conferencing -Ceiling-Array-fig-
\(15\)

Suspend the microphone using your own equipment, or with Shure’s A900-GM kit (includes mounting cables and hooks).

To mount using your own equipment, you will need:

  • Braided metal cable or high-strength wire
  • Hardware to attach cable to ceiling
  1. Attach the mounting cables to the 12 mm diameter eyelet screws on the microphone.
  2. Attach the cables to the ceiling using appropriate hardware.

Install on a Ceiling with the A900-CM

Attach array microphones to the ceiling with the A900-CM mounting kit.
Refer to the A900-CM user guide to learn how to install on other ceiling materials.

Dante Channels

The MXA902 has:

  • 2 input channels
  • 1 automix output with IntelliMix DSP

The 2 input channels are summed and sent to the loudspeaker’s output. These input channels are useful if you need to send a far-end signal and program audio to the loudspeaker. The MXA902’s AEC reference is the same signal sent to the integrated loudspeaker and can’t be changed.

IntelliMix DSP

This device contains IntelliMix digital signal processing blocks that can be applied to the microphone’s output. The DSP blocks include:

  • Acoustic echo cancellation (AEC)
  • Automatic gain control (AGC) Noise reduction
  • Compressor
  • Delay

To access, go to the IntelliMix tab.

DSP Best Practices

  • Apply DSP blocks as needed. Run a test of your system without DSP, and then add processing as needed to fix any is­sues that you hear in the audio signal.
  • Unless you encounter video that lags behind audio, set delay to off.

Acoustic Echo Cancellation

  • In AV conferencing, a person may hear their voice echo. This happens when a near-end microphone picks up audio from the room’s loudspeakers and sends it back to the far end as echo.
  • Acoustic echo cancellation (AEC) is a DSP algorithm that gets rid of distracting echo in your microphone signal. AEC identifies the far­end signal and stops it from being captured by the near­end microphone. During a call, AEC works constantly to opti­mize
  • processing as long as far-end audio is present. AEC is necessary for clear, uninterrupted calls.
  • The MXA902 uses the built-in loudspeaker as the AEC reference signal.

Note : If the loudspeaker is off and you still want to use AEC, route the far-end signal you want to cancel to one of the Dante inputs.

AEC Settings

Reference Meter
Use the reference meter to visually verify the reference signal is present. The reference signal should not be clipping.

ERLE
Echo return loss enhancement (ERLE) displays the dB level of signal reduction (the amount of echo being removed). The ERLE meter generally corresponds to the reference meter.

Reference
The MXA902’s reference signal is set to the built­in loudspeaker, which is the sum of the 2 Dante inputs. When the loud­speaker is on, the reference signal is post-DSP.

Non-Linear Processing
The primary component of the acoustic echo canceller is an adaptive filter. Non-linear processing supplements the adaptive filter to remove any residual echo caused by acoustic irregularities or changes in the environment. Use the lowest possible setting that is effective in your room.

  • Low: Use in rooms with controlled acoustics and minimal echoes. This setting provides the most natural sound for full du­plex.
  • Medium: Use in typical rooms as a starting point. If you hear echo artifacts, try using the high setting.
  • High: Use to provide the strongest echo reduction in rooms with bad acoustics, or in situations where the echo path fre­quently changes.

Choose the Right NLP Setting
If far-end callers hear echo, test different NLP settings to find one that works. In general, it’s best to use the lowest NLP setting that removes echo from your mic signal.
The level of the MXA902’s loudspeaker can also affect how well the AEC removes the reference signal from the mic’s signal. Experiment with using a higher NLP setting when the loudspeaker level is higher.

Noise Reduction

Noise reduction significantly reduces the amount of background noise in your signal caused by projectors, HVAC systems, or other environmental sources. It is a dynamic processor, which calculates the noise floor in the room and removes noise throughout the entire spectrum with maximum transparency.

Settings
The noise reduction setting (low, medium, or high) represents the amount of reduction in dB. Use the lowest possible setting that effectively lowers noise in the room.

Automatic Gain Control (AGC)

  • Automatic gain control automatically adjusts channel levels to ensure consistent volume for all talkers in all scenarios. For qui­eter voices, it increases gain. For louder voices, it attenuates the signal.
  • Enable AGC on channels where the distance between the talker and the microphone may vary, or in rooms where many differ­ent people will use the conferencing system.
  • Automatic gain control happens post-gate (after the automixer) and does not affect when the automixer gates on or off.

Target Level (dBFS)
−37 dBFS as a starting point to ensure adequate headroom and adjust if necessary. This represents the RMS (aver­age) level, which is different from setting the input fader according to peak levels to avoid clipping.

Maximum Boost ( dB)
Sets the maximum amount of gain that can be applied

Maximum Cut ( dB)
Sets the maximum attenuation that can be applied

Tip : Use the boost/cut meter (not available on all microphones) to monitor the amount of gain added or subtracted from the signal. If the meter is always reaching the maximum boost or cut level, adjust the input fader so the signal is closer to the target level.

Delay

  • Use delay to synchronize audio and video. When a video system introduces latency (where you hear someone speak, and their mouth moves later), add delay to align audio and video.
  • Delay is measured in milliseconds. If there is a significant difference between audio and video, start by using larger intervals of delay time (500-1000 ms). When the audio and video are slightly out of sync, use smaller intervals to fine-tune.

Compressor

Use the compressor to control the dynamic range of the selected signal.

Threshold
When the audio signal exceeds the threshold value, the level is attenuated to prevent unwanted spikes in the output sig­nal. The amount of attenuation is determined by the ratio value. Perform a soundcheck and set the threshold 3-6 dB above average talker levels, so the compressor only attenuates unexpected loud sounds.

Ratio
The ratio controls how much the signal is attenuated when it exceeds the threshold value. Higher ratios provide stronger attenuation. A lower ratio of 2:1 means that for every 2 dB the signal exceeds the threshold, the output signal will only ex­ceed the threshold by 1 dB. A higher ratio of 10:1 means a loud sound that exceeds the threshold by 10 dB will only ex­ceed the threshold by 1 dB, effectively reducing the signal by 9 dB.

Parametric Equalizer

Maximize audio quality by adjusting the frequency response with the parametric equalizer. Common equalizer applications:

  • Improve speech intelligibility
  • Reduce noise from HVAC systems or video projectors
  • Reduce room irregularities
  • Adjust frequency response for reinforcement systems

Setting Filter Parameters
Adjust filter settings by manipulating the icons in the frequency response graph, or by entering numeric values. Disable a filter using the check-box next to the filter.

Filter Type

| Only the first and last band have selectable filter types.

Parametric: Attenuates or boosts the signal within a customizable frequency range

Low Cut: Rolls off the audio signal below the selected frequency

Low Shelf: Attenuates or boosts the audio signal below the selected frequency

High Cut: Rolls off the audio signal above the selected frequency

High Shelf: Attenuates or boosts the audio signal above the selected frequency

---|---
Frequency| Select the center frequency of the filter to cut/boost
Gain| Adjusts the level for a specific filter (+/- 30 dB)

Q

| Adjusts the range of frequencies affected by the filter. As this value increases, the bandwidth becomes thinner.

Width

| Adjusts the range of frequencies affected by the filter. The value is represented in octaves.

Note: the Q and width parameters affect the equalization curve in the same way. The only difference is the way the values are represented.

SHURE-MXA902 -Integrated -Conferencing -Ceiling-Array-fig-
\(16\)

Copy, Paste, Import, and Export Equalizer Channel Settings

These features make it simple to use effective equalizer settings from a previous installation, or simply accelerate configuration time.

Copy and Paste
Use to quickly apply the same PEQ setting across multiple channels.

  1. Select the channel from the pull-down menu in the PEQ screen.
  2. Select Copy
  3. In the pull-down menu, select the channel to apply the PEQ setting and select Paste.

Import and Export
Use to save and load PEQ settings from a file on a computer. This is useful for creating a library of reusable configuration files on computers used for system installation.

Export| Choose a channel to save the PEQ setting, and select Export to file.
---|---
Import| Choose a channel to load the PEQ setting, and select Import from file.

Equalizer Applications

Conferencing room acoustics vary based on room size, shape, and construction materials. Use the guidelines in following ta­ble.

EQ Application Suggested Settings

Treble boost for improved speech intelligibility

| Add a high shelf filter to boost frequencies greater than 1 kHz by 3-6 dB
HVAC noise reduction| Add a low cut filter to attenuate frequencies below 200 Hz

Reduce flutter echoes and sibilance

| Identify the specific frequency range that “excites” the room:

1.   Set a narrow Q value

2.   Increase the gain to between +10 and +15 dB, and then experiment with frequencies between 1 kHz and 6 kHz to pinpoint the range of flutter echoes or sibi­ lance

3.   Reduce the gain at the identified frequency (start be­ tween -3 and -6 dB) to minimize the unwanted room sound

Reduce hollow, resonant room sound

| Identify the specific frequency range that “excites” the room:

1.   Set a narrow Q value

2.   Increase the gain to between +10 and +15 dB, and then experiment with frequencies between 300 Hz and 900 Hz to pinpoint the resonant frequency

3.   Reduce the gain at the identified frequency (start be­ tween -3 and -6 dB) to minimize the unwanted room sound

EQ Contour
Use the EQ contour to quickly apply a high-pass filter at 150 Hz to the microphone’s signal. Select EQ contour to turn it on or off.

Encryption

  • Audio is encrypted with the Advanced Encryption Standard (AES-256), as specified by the US Government National Institute of Standards and Technology (NIST) publication FIPS-197. Shure devices that support encryption require a passphrase to make a connection. Encryption is not supported with third-party devices.
  • In Designer, you can only enable encryption for all devices in a room in live mode: [Your room] > Settings > Audio ­encryption.

To activate encryption in the web application:

  1. Go to Settings > Audio encryption > Enable encryption.
  2. Enter a passphrase. All devices must use the same passphrase to establish an encrypted connection.

Important : For encryption to work:

  • All Shure devices on your network must use encryption.
  • Disable AES67 in Dante Controller. AES67 and AES-256 cannot be used at the same time.

Important : Use Designer 4.7.25 or newer to discover the MXA902. Refer to MXA902 Limitations for details about using the MXA902 with Designer 4.7.25 and certain Shure device firmware.

Networking Best Practices

When connecting Shure devices to a network, use the following best practices:

  • Always use a “star” network topology by connecting each device directly to the switch or router.

  • Connect all Shure networked devices to the same network and set to the same subnet.

  • Allow all Shure software through the firewall on your computer.

  • Use only 1 DHCP server per network. Disable DHCP addressing on additional servers.
    Power on the switch and DHCP server before powering on the Shure devices.

  • To expand the network, use multiple switches in a star topology.

  • All devices must be at the same firmware revision level.

Switch and Cable Recommendations for Dante Networking

Switches and cables determine how well your audio network performs. Use high­quality switches and cables to make your au­dio network more reliable.

Network switches should have:

  • Gigabit ports. 10/100 switches may work on small networks, but gigabit switches perform better.
  • Power over Ethernet (PoE) or PoE+ ports for any devices that require power
  • Management features to provide information about port speed, error counters, and bandwidth used
  • Ability to switch off Energy Efficient Ethernet (EEE). EEE (also known as “Green Ethernet”) may cause audio dropouts and problems with clock synchronization.
  • Diffserv (DSCP) Quality of Service (QoS) with strict priority and 4 queues

Ethernet cables should be:

  • Cat5e or better
  • Shielded

For more information, see our FAQ about switches to avoid.

Device IP Configuration

This Shure device uses 2 IP addresses: one for Shure control, and one for Dante audio and control.

  • Shure control
    • Carries data for Shure control software, firmware updates, and third-party control systems (such as AMX or Crestron)
  • Dante’s audio and control
    • Carries Dante digital audio and control data for Dante
    • Controller Requires a wired, gigabit Ethernet connection to operate

To access these settings in Designer, go to [Your device] > Settings > IP configuration.

Setting Latency

Latency is the amount of time for a signal to travel across the system to the outputs of a device. To account for variances in la­tency time between devices and channels, Dante has a predetermined selection of latency settings. When the same setting is selected, it ensures that all Dante devices on the network are in sync.These latency values should be used as a starting point. To determine the exact latency to use for your setup, deploy the set­up, send Dante audio between your devices, and measure the actual latency in your system using Audinate’s Dante Controller software. Then round up to the nearest latency setting available, and use that one. Use Audinate’s Dante Controller software to change latency settings.

Latency Recommendations

Latency Setting Maximum Number of Switches
0.25 ms 3
0.5 ms (default) 5
1 ms 10
2 ms 10+

QoS (Quality of Service) Settings

QoS settings assign priorities to specific data packets on the network, ensuring reliable audio delivery on larger networks with heavy traffic. This feature is available on most managed network switches. Although not required, assigning QoS settings is recommended.

Note : Coordinate changes with the network administrator to avoid disrupting service.

To assign QoS values, open the switch interface and use the following table to assign Dante -associated queue values.

  • Assign the highest possible value (shown as 4 in this example) for time-critical PTP events
  • Use descending priority values for each remaining packet.

Dante QoS Priority Values

Priority| Usage| DSCP Label| Hex| Decimal| Binary
---|---|---|---|---|---

High (4)

| Time-critical PTP events|

CS7

|

0x38

|

56

|  111000
Medium (3)| Audio, PTP| EF| 0x2E| 46| 101110
Low (2)| (reserved)| CS1| 0x08| 8| 001000
None (1)| Other traffic| BestEffort| 0x00| 0| 000000

Note : Switch management may vary by manufacturer and switch type. Consult the manufacturer’s product guide for specific configuration details.
For more information on Dante’s requirements and networking, visit www.audinate.com.

Networking Terminology

  • PTP (Precision Time Protocol): Used to synchronize clocks on the network
  • DSCP (Differentiated Services Code Point): Standardized identification method for data used in layer 3 QoS prioritization

IP Ports and Protocols

Shure Control

Port

|

TCP/UDP

|

Protocol

|

Description

| Factory De­

fault

---|---|---|---|---
21| TCP| FTP| Required for firmware updates (otherwise closed)| Closed
22| TCP| SSH| Secure Shell Interface| Closed
23| TCP| Telnet| Not supported| Closed
53| UDP| DNS| Domain Name System| Closed
67| UDP| DHCP| Dynamic Host Configuration Protocol| Open
68| UDP| DHCP| Dynamic Host Configuration Protocol| Open
**80*| TCP| HTTP| Required to launch embedded web server| Open
443| TCP| HTTPS| Not supported| Closed
2202| TCP| ASCII| Required for 3rd party control strings| Open
5353| UDP| mDNS†| Required for device discovery| Open
5568| UDP| SDT (multicast)†| Required for inter-device communication| Open
57383| UDP| SDT (unicast)| Required for inter-device communication| Open
8023| TCP| Telnet| Debug console interface| Closed
8180| TCP| HTML| Required for web application (legacy firmware only)| Open
8427| UDP| SLP (multicast)†| Required for inter-device communication| Open
64000**| TCP| Telnet| Required for Shure firmware update| Open

*These ports must be open on the PC or control system to access the device through a firewall.
These protocols require multicast. Ensure multicast has been correctly configured for your network. See Audinate’s website for information about ports and protocols used by Dante Audio.

Digital Audio Networking

Dante digital audio is carried over standard Ethernet and operates using standard internet protocols. Dante provides low la­tency, tight clock synchronization, and high Quality­of­Service (QoS) to provide reliable audio transport to a variety of Dante de­vices. Dante audio can coexist safely on the same network as IT and control data, or can be configured to use a dedicated net­work.

Compatibility with Dante Domain Manager
This device is compatible with Dante Domain Manager software (DDM). DDM is network management software with user au­thentication, role-based security, and auditing features for Dante networks and Dante-enabled products. Considerations for Shure devices controlled by DDM:

  • When you add Shure devices to a Dante domain, set the local controller access to Read Write. Otherwise, you won’t be able to access Dante settings, perform a factory reset, or update device firmware.
  • If the device and DDM can’t communicate over the network for any reason, you won’t be able to control Dante settings, perform a factory reset, or update device firmware. When the connection is reestablished, the device follows the policy set for it in the Dante domain.
  • If Dante’s device lock is on, DDM is offline, or the configuration of the device is set to Prevent, some device settings are dis­abled. These include Dante encryption, MXW association, AD4 Dante browse and Dante cue, and SCM820 linking.

Refer to Dante Domain Manager’s documentation for more information.

Dante Flows for Shure Devices

  • Dante flows get created any time you route audio from one Dante device to another. One Dante flow can contain up to 4 audio channels. For example: sending all 5 available channels from an MXA310 to another device uses 2 Dante flows, because 1 flow can contain up to 4 channels.
  • Every Dante device has a specific number of transmit flows and receive flows. The number of flows is determined by Dante platform capabilities.
  • Unicast and multicast transmission settings also affect the number of Dante flows a device can send or receive. Using multi­cast transmission can help overcome unicast flow limitations.

Shure devices use different Dante platforms:

Dante Platform

| Shure Devices Using Plat­

form

| Unicast Transmit Flow Limit|

Unicast Receive Flow Limit

---|---|---|---

Brooklyn II

| ULX-D, SCM820, MXWAPT, MXWANI, P300, MXCWAPT|

32

|

32

Brooklyn II (without SRAM)

| MXA920, MXA910, MXA902, MXA710, AD4|

16

|

16

Ultimo/UltimoX

| MXA310, ANI4IN, ANI4OUT, ANIUSB-MATRIX, ANI22, MXN5-C|

2

|

2

DAL| IntelliMix Room| 16| 16

AES67

AES67 is a networked audio standard that enables communication between hardware components which use different IP au­dio technologies. This Shure device supports AES67 for increased compatibility within networked systems for live sound, inte­grated installations, and broadcast applications.

The following information is critical when transmitting or receiving AES67 signals:

  • Update Dante Controller software to the newest available version to ensure the AES67 configuration tab appears.
  • Before turning encryption on or off, you must disable AES67 in Dante Controller.
  • AES67 cannot operate when the transmit and receive devices both support Dante.
Shure Device Supports: Device 2 Supports: AES67 Compatibility
Dante and AES67 Dante and AES67 No. Must use Dante.

Dante and AES67

| AES67 without Dante. Any other au­

dio networking protocol is acceptable.

|

Yes

Separate Dante and AES67 flows can operate simultaneously. The total number of flows is determined by the maximum flow limit of the device.

Sending Audio from a Shure Device

All AES67 configuration is managed in Dante Controller software. For more information, refer to the Dante Controller user guide.

  1. Open the Shure transmitting device in Dante Controller.
  2. Enable AES67.
  3. Reboot the Shure device.
  4. Create AES67 flows according to the instructions in the Dante Controller user guide.

Receiving Audio from a Device Using a Different Audio Network Protocol
Third-party devices: When the hardware supports SAP, flows are identified in the routing software that the device uses. Oth­erwise, to receive an AES67 flow, the AES67 session ID and IP address are required. Shure devices: The transmitting device must support SAP. In Dante Controller, a transmit device (appears as an IP address) can be routed like any other Dante device.

Paint Square Array Microphones

You can paint the grille and frame of square ceiling array microphones to blend in with a room’s design. Note: Don’t remove any of the screws on the MXA902’s loudspeaker enclosure while painting.

Step 1: Remove the Frame and Grille

  1. On each side of the frame, remove the 6 screws and washers that attach the main assembly to the frame. Important: Do not remove the 4 recessed screws in each corner.

  2. Carefully lift the assembly out of the frame.

  3. Remove the gray plastic LED lightpipe. Leave the black plastic guide in place.

  4. Remove all 4 recessed screws from one side of the frame. Remove that side of the frame.

  5. Slide the flat grille out of the frame.

  6. Carefully remove the foam piece from the grille. Pull from the edges, where it is attached with hook-and-loop fastener strips.
    Important : Do not paint the foam.

  7. Before painting, reinstall the side of the frame you removed in step 1.4.

Step 2: Mask and Paint

  1. Use masking tape to cover the entire extrusion (highlighted in black) that runs along the inside of the frame. This en­sures that the necessary metal pieces make contact when reassembled.SHURE-MXA902 -Integrated -Conferencing -Ceiling-Array-fig- \(19\)
  2. Use masking tape to cover the hook-and-loop fastener strips on the grille.
  3. Paint the frame and grille. Let them dry completely before reassembling. Do not paint any part of the main assembly.

Step 3: Reassembly

  1. Attach the foam piece to the grille with the hook-and-loop fastener strips.

  2. Remove one side of the frame as in step 1.4. Slide the grille back into the frame. Attach the remaining side of the frame and secure it with the 4 screws.

  3. Attach the LED lightpipe to the black plastic guide piece.

  4. Align the LED with the lightpipe and put the main assembly back in place on the frame.
    Note : The label on the assembly is in the corner that corresponds to the LED.

  5. Install 6 screws per side to secure the main assembly to the frame. Do not over-tighten.

Using Command Strings

This device receives logic commands over the network. Many parameters controlled through Designer can be controlled using a third-party control system, using the appropriate command string.

Common applications:

  • Mute
    LED color and behavior

  • Loading presets

  • Adjusting levels

A complete list of command strings is available at: pubs.shure.com/command- strings/mxa902.

Troubleshooting

Problem Solution

No microphone signal or signal is quiet/distorted

|

Check cables.

Verify that output channel isn’t muted. Check that output levels are not set too low.

No loudspeaker signal

|

Check that MXA902 is plugged in to a PoE+ source. The MXA902 powers on when connected to PoE, but the loud­ speaker does not work.

Check cables.

Verify that input channels aren’t muted.

Check that signals are properly routed to the input channels.

Microphone sound quality is muffled or hollow

|

Check that coverage area is positioned correctly and mic levels are sufficient.

Use EQ to adjust frequency response.

MXA902 does not power on

|

Check that MXA902 is plugged in to a PoE+ source. The MXA902 powers on when connected to PoE, but the loud­ speaker does not work.

Check network cables and connections.

MXA902 doesn’t show up in Designer or Shure Web De­

vice Discovery

|

Ensure that MXA902 has power.

Make sure MXA902 is on the same network and subnet as PC.

Turn off network interfaces not used to connect to the device (such as Wi-Fi).

Check that DHCP server is functioning (if applicable). Reset the device if necessary.

Refer to no online devices FAQ for more help.

Flashing red error LED

| Go to [Your device] > Settings > General > Export log to export the device event log. Designer also has an event log in the main menu that collects information for all Designer devices. Use the event logs to get more informa­ tion, and contact Shure if necessary.

No lights

| Go to [Your device] > Settings > Lights. Check if brightness is disabled or if any other settings are turned off.
Web application lags in Google Chrome browser| Turn off hardware acceleration option in Chrome.

Additional Resources

  • Shure Knowledge Base FAQs
  • Command strings for Shure devices
  • Shure Enterprise Networking Troubleshooting Checklist Training from the Shure Audio Institute
  • Shure Systems YouTube channel

Download Shure Software

  • Shure Designer
  • Shure Update Utility
  • Shure Web Device Discovery
  • Software and firmware archive

Specifications

General

  • Coverage Area Size
    • 20 x 20 ft (6.1 x 6.1 m)
  • Coverage Type
    • Single-zone automatic
  • Power Requirements
    • Power over Ethernet Plus (PoE+), Class 4
  • Power Consumption
    • 24 W maximum
  • Control Software
    • Designer
  • Cable Requirements
    • Cat5e or higher (shielded cable recommended)
  • Connector Type
    • RJ45
  • Plenum Rating
    • UL2043 (Suitable for Air Handling Spaces)
  • Dust Protection
    • IEC 60529 IP5X Dust Protected
  • Operating Temperature Range
    • 6.7°C (20°F) to 40°C (104°F)
  • Storage Temperature Range
    • 29°C (−20°F) to 74°C (165°F)

Microphone

  • Frequency Response
    • 125 Hz to 20 kHz

AES67 or Dante Digital Output

Channel Count 1 output channel
Sampling Rate 48 kHz
Bit Depth 24
  • Sensitivity at 1 kHz

    • 1.74 dBFS/Pa
  • Maximum SPL

    • Relative to 0 dBFS overload
  • 95.74 dB SPL

    • Signal-to-Noise Ratio
  • Ref. 94 dB SPL at 1 kHz

    • 75.76 dB A­weighted
  • Latency

    • Does not include Dante latency 26.6 ms
  • Self Noise

    • 18.24 dB SPL­A
  • Dynamic Range

    • 77.5 dB
  • Digital Signal Processing

    • Automatic mixing, acoustic echo cancellation (AEC), noise reduction, automatic gain control, compressor, delay, equalizer (4­band parametric), mute, gain (140 dB range)
  • Acoustic Echo Cancellation Tail Length

    • Up to 250 ms

Loudspeaker
AES67 or Dante Digital Input

Channel Count 2 input channels

Frequency Range (−10 dB)
120 Hz to 20 kHz

Maximum Output Level
At 1 meter

Pink noise 86 dB SPL
1 kHz sine tone 88 dB SPL

Coverage Angle
Average of 1-octave band centered on 4 kHz  80°

Digital Signal Processing
Delay, compressor, signal generator, equalizer (4-band parametric)

Latency
Not including Dante latency

MXA902 Microphone Frequency Response
Frequency response measured directly on-axis from a distance of 6 feet (1.83 m).

SHURE-MXA902 -Integrated -Conferencing -Ceiling-Array-fig-
\(20\)

Dimensions
MXA902-S:

SHURE-MXA902 -Integrated -Conferencing -Ceiling-Array-fig-
\(21\)

  • A (Flange): 0.41 in. (10.5 mm)
  • B (Edge to edge): 23.77 in. (603.8 mm)
  • C (Height): 2.2 in. (56.04 mm)

MXA902-S-60CM:

SHURE-MXA902 -Integrated -Conferencing -Ceiling-Array-fig-
\(22\)

  • A (Edge to edge): 23.38 in. (593.8 mm)
  • B (Height): 2.2 in. (56.04 mm)

Weight
MXA902-S or MXA902-S-60CM: 12.7 lb. (5.8 kg)

IMPORTANT SAFETY INSTRUCTIONS\

  1. READ these instructions.
  2. KEEP these instructions.
  3. HEED all warnings.
  4. FOLLOW all instructions.
  5. DO NOT use this apparatus near water.
  6. CLEAN ONLY with dry cloth.
  7. DO NOT block any ventilation openings. Allow sufficient distances for adequate ventilation and install in accordance with the manufacturer’s instructions.
  8. DO NOT install near any heat sources such as open flames, radiators, heat registers, stoves, or other apparatus (in­cluding amplifiers) that produce heat. Do not place any open flame sources on the product.
  9. DO NOT defeat the safety purpose of the polarized or grounding type plug. A polarized plug has two blades with one wider than the other. A grounding type plug has two blades and a third grounding prong. The wider blade or the third prong are provided for your safety. If the provided plug does not fit into your outlet, consult an electrician for replace­ment of the obsolete outlet.
  10. PROTECT the power cord from being walked on or pinched, particularly at plugs, convenience receptacles, and the point where they exit from the apparatus.
  11. ONLY USE attachments/accessories specified by the manufacturer.
  12. USE only with a cart, stand, tripod, bracket, or table specified by the manufacturer, or sold with the apparatus. When a cart is used, use caution when moving the cart/apparatus combination to avoid injury from tip-over.
  13. UNPLUG this apparatus during lightning storms or when unused for long periods of time.
  14. REFER all servicing to qualified service personnel. Servicing is required when the apparatus has been damaged in any way, such as power supply cord or plug is damaged, liquid has been spilled or objects have fallen into the apparatus, the apparatus has been exposed to rain or moisture, does not operate normally, or has been dropped.
  15. DO NOT expose the apparatus to dripping and splashing. DO NOT put objects filled with liquids, such as vases, on the apparatus.
  16. The MAINS plug or an appliance coupler shall remain readily operable.
  17. The airborne noise of the Apparatus does not exceed 70dB (A).
  18. Apparatus with CLASS I construction shall be connected to a MAINS socket outlet with a protective earthing connec­tion.
  19. To reduce the risk of fire or electric shock, do not expose this apparatus to rain or moisture.
  20. Do not attempt to modify this product. Doing so could result in personal injury and/or product failure.
  21. Operate this product within its specified operating temperature range.

This symbol indicates that dangerous voltage constituting a risk of electric shock is present within this unit.
This symbol indicates that there are important operating and maintenance instructions in the literature accom­panying this unit.

Important Product Information

The equipment is intended to be used in professional audio applications. Please follow your regional recycling scheme for batteries, packaging, and electronic waste.

Waste Electrical and Electronic Equipment (WEEE) Directive

  • In the European Union and the United Kingdom, this label indicates that this product should not be disposed of with household waste. It should be deposited at an appropriate facility to enable recovery and recycling.
  • Registration, Evaluation, Authorization of Chemicals (REACH) Directive
  • REACH (Registration, Evaluation, Authorization of Chemicals) is the European Union (EU) and the United Kingdom (UK) chemical substances regulatory framework. Information on substances of very high concern contained in Shure products in a concentration above 0.1% weight over weight (w/w) is available upon request.
  • Dante is a registered trademark of Audinate Pty Ltd.

Information to the user
This product has been tested and found to comply with the limits for a Class A digital device pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operat­ed in a commercial environment. This product generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the manufacturer’s instruction manual, may cause harmful interference with radio communications. Operation of this product in a residential area is likely to cause harmful interference, in which case you will be required to cor­rect the interference at your own expense.

This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions:

  1. This device may not cause harmful interference.
  2. This device must accept any interference received, including interference that may cause undesired operation.

Notice : The FCC regulations provide that changes or modifications not expressly approved by Shure Incorporated could void your authority to operate this equipment.

These limits are designed to provide reasonable protection against harmful interference in a non­residential installation. How­ever, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful inter­ference with radio or television reception, which can be determined by turning the equipment off and on, you are encouraged to try to correct the interference by one or more of the following measures:

  • Reorient or relocate the antenna of the radio/television receiver.
  • Increase the separation between this equipment and the radio/television receiver.
  • Plug the equipment into a different outlet so that the equipment and the radio/television receiver are on different power mains branch circuits.
  • Consult a representative of Shure or an experienced radio/television technician for additional suggestions.

EMC conformance testing is based on the use of supplied and recommended cable types. The use of other cable types may degrade EMC performance.
Shure has determined that this product is a Class A harmonized product. The following sections provide country-specific EMC/EMI or product safety information.
For information regarding responsible party and other matters relating to FCC compliance, please contact Shure Incorporated, 5800 W. Touhy Avenue, Niles, Illinois 60714-4608 U.S.A. shure.com/contact

Warning : This is a Class A product. In a domestic environment this product may cause radio interference in which case the user may be required to take adequate measures.

Certifications

CE Notice

UKCA Notice

  • Hereby, Shure Incorporated declares that this product with UKCA Marking has been determined to be in compliance with UK­CA requirements.
  • The full text of the UK declaration of conformity is available at the following site: https://www.shure.com/en­GB/support/declara­tions-of-conformity.
  • This Class A digital apparatus complies with Canadian ICES-003. Cet appareil numérique de la classe A est conforme à la norme NMB-003 du Canada.

Canada, ISED Notice
Notice : The Industry Canada regulations provide that changes or modifications not expressly approved by Shure Inc. could void your authority to operate this equipment.

References

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>