EMOS ZO0303 LED Streetlight Instruction Manual
- June 17, 2024
- EMOS
Table of Contents
EMOS ZO0303 LED Streetlight
Product Information
Specifications:
- Part Number: ZO0303
- Input Voltage: 30 W
- Color Temperature: 3,000 K (warm white), 4,000 K (neutral white)
- Luminous Flux: 3,600 lm, 6,000 lm, 8,400 lm
- Lifespan: 36,000 hours
- Protection Rate: IP65
Product Usage Instructions
Mounting:
- Ensure the power supply is turned off before installation.
- Adjust the lamp to the desired position and tighten the screw of the fixing bracket.
- Connect your mains cable with the input lead of the lamp through the waterproof junction box (IP65 or above).
- Adjust the lamp angle and install it in the right position.
- Attach the fixing bracket to the light pole with suitable screws.
- Turn on the power.
Maintenance Instructions:
Before maintenance, switch off the lamp and wait until it is cooled. Clean
it with a soft moistened cloth. Never submerge the lamp in water or other
liquids. During maintenance, observe general rules for occupational safety and
be very careful.
FAQ
-
Q: What should I do if the lamp is not working properly after installation?
A: If the lamp is not working correctly after installation, please check the power supply, and connections, and ensure that all steps of installation have been followed correctly. If issues persist, contact customer support for assistance. -
Q: Can I use this product indoors?
A: This LED streetlight is designed for outdoor use and should not be used indoors. Using it indoors may result in damage to the product or unsafe conditions. -
Q: How can I adjust the brightness of the light?
A: The brightness of the light cannot be adjusted as it has a fixed luminous flux. For different brightness levels, consider using a different wattage model.
LED Streetlight
LED Streetlight is designed for outdoor use to be mounted onto a pole. Ingress Protection IP65 – for outdoor use.
DIMENSIONS
Part No.
|
Input Voltage
|
Power
| Color Temperature (K)| Luminous flux (lm)|
Beam angle
| Lifespan (hours)| Protection rate|
CRI (Ra)
|
Dimensions
---|---|---|---|---|---|---|---|---|---
ZO0303|
220–240 V AC
| 30 W| 3 000 K
(warm white)
| 3 600 lm|
130 × 60°
|
36 000 h
|
IP65
|
80
| 412 × 146 × 63 mm
ZO0304| 30 W|
4 000 K
(neutral white)
| 3 600 lm| 412 × 146 × 63 mm
ZO0504| 50 W| 6 000 lm| 412 × 146 × 63 mm
ZO0704| 70 W| 8 400 lm| 515 × 175 × 63 mm
MOUNTING
- Ensure that the power supply is turned off before installation (see Fig. 1)
- Adjust the lamp to the desired position and tighten the screw of the fixing bracket. Connect your mains cable with the input lead of the lamp through the waterproof junction box (see fig. 2). (Need to use the junction box of IP65 or above, ensure to tighten the waterproof screw.)
- Adjust the lamp Angle and install it in the right position (see fig.3). Attach the fixing bracket to the light pole with suitable screws (see fig. 4, 5)
- Turn on the power (see fig.6)
Maintenance instructions
- Before maintenance, switch off the lamp and wait until it is cooled.
- Clean it with a soft moistened cloth.
- Never submerge the lamp in water or other liquids.
- During maintenance, observe general rules for occupational safety, and be very careful.
WARNING
- If the external flexible cable or cord of this luminaire is damaged, it shall be exclusively replaced by the manufacturer or his service agent or a similarly qualified person to avoid a hazard.
- The light source contained in this luminaire shall only be replaced by the manufacturer or his service agent or a similar qualified person.
- Terminal block not included. Installation may require advice from a qualified person.
- Terminal block for connection of power supply: 3 terminals screw-type or screw-less type, rated for cross-section range including 1.0 mm² and voltage min 230 V.
- The Street light fitting may only be connected to electrical mains with installation and protection that is in line with valid regulations and standards.
- Before interfering with the Street light fitting or performing maintenance and repair, the light fitting must be disconnected from the mains. This must only be done by a knowledgeable/experienced person within the meaning of valid regulations on qualification for such activities.
- Protection against dangerous contact voltage is ensured through connection to a neutral conductor.
- The exterior flexible cable for the light fitting cannot be replaced; if the cable is damaged, the light fitting must be disposed of.
- The light source of the light fitting is not replaceable; after the end of the light fitting‘s service life, the entire light fitting must be replaced.
- The light fitting does not come with a terminal box. Installation may require the assistance of a qualified person.
- Caution, risk of electric shock.
EMOS spol. s r.o. declares that the ZO0303, ZO0304, ZO0504, and ZO0704 comply
with the essential requirements and other relevant provisions of the
Directive. The device can be freely operated in the EU. The Declaration of
Conformity can be found at http://www.emos.eu/download.
This product contains a light source of energy efficiency class E
References
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>