LAPP 44423228 MHB Coax Instruction Manual

June 17, 2024
LAPP

LAPP 44423228 MHB Coax

Product Information

Specifications

  • Material Description: H-D SCEM AG 0.14-0.37
  • Contact Type: Female
  • Number of Working Contacts: 4 + Shielding
  • Recommended Ethernet Configuration: 10BASE-T, 100BASE-TX Rx + Rx Tx Tx +

Product Usage Instructions

Prepare Cable End

  1. Strip the cable to approximately 20mm.
  2. Fold back the shielding braid and secure it with a heat shrink tube.

Crimp Contacts
Crimp the contacts by inserting them into the contact carrier until they snap in.

Pin Arrangement
Observe the pin arrangement for proper connection:

Contact 1 2 3 4
10BASE-T white green orange white / orange

Coding
Tighten the 8 PE screws with 1.2 Nm torque.

Disassembling Contacts

  1. To disassemble contacts, use the extraction tool from the backside of the insulation body in the contact chamber.
  2. Push back the contact lock and pull out the contact from the chamber.

Frequently Asked Questions (FAQ)

Q: How do I disassemble the contacts?
A: To disassemble the contacts, use the extraction tool provided. Slide it from the back side of the insulation body in the contact chamber. Pay attention to the correct alignment.

Q: What is the recommended Ethernet configuration for this product?
A: The recommended Ethernet configuration is 10BASE-T, 100BASE-TX Rx + Rx Tx Tx + with specific color coding for each contact.

References