FOS technologies 200W Bicolor LED Fresnel User Manual

June 17, 2024
FOS technologies

FOS technologies 200W Bicolor LED Fresnel

FOS technologies 200W Bicolor LED Fresnel 

Symbol Please read this user manual before using this product!

Keep it for further reference!

Thank you

Thank you for using our product! Please read this manual carefully and. For technical reference in future, please keep this user manual well. This user manual contains all installation and operation information of this LED fixture, it’s very useful for user to install and operate the light. Please strictly abide by the relevant instruction for the installation and operation.
This light meets the following criteria:
GB7000.1-2007/IEC60598-1:2003
GB7000.217-2008/IEC60598-2-17:1984+A2:1990

PRODUCT MAIN FEATURES

The light’s lighting function is controlled by DMX-512.
Using international standard (1990) DMX single, digital control panel display.
With 2 DMX channel as dimmer.
0~100%, smooth dimmer.
CRI more than 91, 3200~5600K color temperature optional, light effective distance is 3~8 meters.
Passive cooling, with large heatsink for completely silent operation.

OVERVIEW AND DIMENSIONS

Overview And Dimensions

SAFETY INFORMATION

Important

Every person involved with the installation, operation and maintenance of this device must be qualified and follow the instructions of this manual. Manufacturer will not with responsibility for problems caused by mishandling and wrong installation.
Verify that the voltage matches the rated voltage.
When the voltage is 110V, do not connect more than 10 lightings in total to AC mains power in one interconnected daisy chain
When the voltage is 220V, do not connect more than 20 lightings in total to AC mains power in one interconnected daisy chain.
Before using the fixture, check that all power distribution equipment and cables are in perfect condition and rated for the current requirements of all connected devices.
Always ground (earth) the fixture electrically.
Avoiding hit the Light during move or installation.
The minimum distance between light-output and the illuminated surface must be more than 0.5 meters. Keep all combustible materials (for example fabric, wood, paper) at least 0.2 meters away from the fixture.
Do not expose the fixture to rain or moisture.
Avoid looking directly into the light source (especially those who suffer from epileptic fits) Maximum ambient temperature (Ta) is 40°C. Do not operate fixture at temperatures higher than this.
The Maximum surface temperature is 50°C When suspending the fixture above ground level, verify that the structure can hold at least 10 times the weight of all installed devices.
Verify that all external covers and rigging hardware are securely fastened and use an approved means of secondary attachment such as a safety cable.

POWER CONNECTION

INSTALLING A NEUTRIK CONNECTOR ON A POWER CABLE

Power ConnectionPower
Connection

Put bushing and chuck onto the cable.
Prepare cable as shown above. The power cable must be a three-conductor 2.5mm2 cable.
Insert the wire into the terminals and fasten the clamping device by a flat screwdriver.
Push insert and chuck into housing (pay attention to the guiding keyway).
Fasten bushing.
The color-coding schemes and some possible pin identification schemes; if pins are not clearly identified, or if you have any doubts about proper installation, consult a qualified electrician.

Power Connection
Power Connection

The power cable must be a three-conductor 2.5mm2 cable.
When the voltage is 110V, do not connect more than 10 lightings in total to AC mains power in one interconnected daisy chain.
When the voltage is 220V, do not connect more than 20 lightings in total to AC mains power in one interconnected daisy chain.

Wire color Conductor Symbol
Brown Live L
Blue Neutral N
Yellow/green ground

PHYSICAL INSTALLATION

This lighting can be placed on a horizontal surface such as a stage or clamped to a truss or similar rigging structure in any orientation using a rigging clamp.
When suspending the fixture above ground level, verify that the structure can hold at least 10 times the weight of all installed devices.
Verify that all external covers and rigging hardware are securely fastened and use an approved means of secondary attachment such as a safety cable.

CONTROL PANNEL

Control Pannel

Rotating the “Mode” knob to setting the main menu, press to enter.
Rotating the “Manual” knob to setting the sub menu, press to esc.
After the setting, you can rotate the Manual knob for CCT and linear dimmer.

Control Pannel

MENU MAP

Main menu

DMX PROTOCOL

DMX512 STD CHANNEL MODE (2-WAY LED)

DMX CHANNEL

CH Name Value Function
CH1 Dimmer 000←→255 Dimmer from 0% to 100%
CH2 Warm white 000←→255 Warm white
CH3 Cool white 000←→255 Cool white

DMX CHANNEL STROBE

CH Name Value Function
CH1 Dimmer 000←→255 Dimmer from 0% to 100%
CH2 Strobe 000←→009

010←→255

| No strobe

Strobe from slow to fast

CH3| Warm white| 000←→255| Warm white
CH4| Cool white| 000←→255| Cool white

DMX512 EXT CHANNEL MODE (2-WAY LED)

DMX CHANNEL

CH Name Value Function
CH1 Dimmer 000←→255 Dimmer from 0% to 100%
CH2 Color temperature 000←→009

010←→255

| No function CT from 3200K to 5600K

DMX CHANNEL STROBE

CH Name Value Function
CH1 Dimmer 000←→255 Dimmer from 0% to 100%
CH2 Strobe 000←→009

010←→255

| No strobe

Strobe from slow to fast

CH3| Color temperature| 000←→009| No function

MEETING CHANNEL MODE (NEED CONTROL BY SPECIAL CONTROL BOX)

MEETING CHANNEL

CH Name Value Function
CH1 Dimmer 000←→255 Dimmer from 0% to 100%
CH2 Color temperature 000←→255 3200K ~ 5600K Color temperature= 8Bit * 256
  • 16Bit
    CH3| Color temperature| 000←→255| 3200K ~ 5600K Color temperature= 8Bit * 256
  • 16Bit

MEETING CHANNEL STROBE

CH Name Value Function
CH1 Dimmer 000←→255 Dimmer from 0% to 100%
CH2 Color temperature 000←→255 3200K ~ 5600K Color temperature= 8Bit * 256
  • 16Bit
    CH3| Color temperature| 000←→255| 3200K ~ 5600K Color temperature= 8Bit * 256
  • 16Bit

LUX CHART

Lux Chart

COMMON INSTRUCTION

The light uses international 3 pins DMX signal cannon for DMX in and DMX out;
The light uses blue LCD display to show the parameter. If there is no DMX in, the display will show the information which you can check from the menu map.
In fact, the light has 2 DMX channels modes, please refer the DMX channel chart.
This light uses full aluminum shell for the heat dissipation, and electronic temperature detection to ensure the proper operation of the circuit at any time.
This light is only for indoor use, when you install it by hanging, please use the safety cable to ensure the safety.
If you have any questions, please contact our support department.

TECHNICAL SPECIFICATION

Input voltage: AC100~240V, 50/60Hz.
Power consumption: 120W
Light output power : 100W for every color
Light source : 200W high power bicolor led lamp
LED life : 50,000 hours
Color temperature : 3200 K-5600K.
CRI : Ra (CRI)≥95, R9≥90, TLCI≥95
Optics : 15–35-degree linear manual zoom
Dimming : 0-100% linear dimming
Channel : 2CH, 3CH, 4CH based on different mode
Control mode : wired DMX /manual control.
Control panel : TFT color display screen & two dimming knobs.
Central illumination: 5 meters 4760LUX (5600K, 15 °)
Protection class : IP20
Working temperature: -25℃~ +40℃
Shell material: aluminum alloy

APPENDIX

Problem and solution

Problem Reason Resolution
Device does not work No power AC100-240V, 50/60Hz Check the power

connection, and make sure device connect the mains in well condition.
Check if the fuse is good.
LED Bulb is off| LED bulb damaged| Replacing LED module
LED drive board damaged| Replacing LED drive board
Temperature  switches damaged| Replacing temperature switch

Caution

  • Unqualified person involved with installation, operation and maintenance of this device is prohibited.
  • If any above-mentioned problem happened, or unknown problem happened, please contact our support department.

Logo

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

FOS technologies User Manuals

Related Manuals