This light meets the following criteria:
GB7000.1-2007/IEC60598-1:2003
GB7000.217-2008/IEC60598-2-17:1984+A2:1990
PRODUCT MAIN FEATURES
The light’s lighting function is controlled by DMX-512.
Using international standard (1990) DMX single, digital control panel display.
With 2 DMX channel as dimmer.
0~100%, smooth dimmer.
CRI more than 91, 3200~5600K color temperature optional, light effective
distance is 3~8 meters.
Passive cooling, with large heatsink for completely silent operation.
OVERVIEW AND DIMENSIONS
SAFETY INFORMATION
Important
Every person involved with the installation, operation and maintenance of this
device must be qualified and follow the instructions of this manual.
Manufacturer will not with responsibility for problems caused by mishandling
and wrong installation.
Verify that the voltage matches the rated voltage.
When the voltage is 110V, do not connect more than 10 lightings in total to AC
mains power in one interconnected daisy chain
When the voltage is 220V, do not connect more than 20 lightings in total to AC
mains power in one interconnected daisy chain.
Before using the fixture, check that all power distribution equipment and
cables are in perfect condition and rated for the current requirements of all
connected devices.
Always ground (earth) the fixture electrically.
Avoiding hit the Light during move or installation.
The minimum distance between light-output and the illuminated surface must be
more than 0.5 meters. Keep all combustible materials (for example fabric,
wood, paper) at least 0.2 meters away from the fixture.
Do not expose the fixture to rain or moisture.
Avoid looking directly into the light source (especially those who suffer from
epileptic fits) Maximum ambient temperature (Ta) is 40°C. Do not operate
fixture at temperatures higher than this.
The Maximum surface temperature is 50°C When suspending the fixture above
ground level, verify that the structure can hold at least 10 times the weight
of all installed devices.
Verify that all external covers and rigging hardware are securely fastened and
use an approved means of secondary attachment such as a safety cable.
POWER CONNECTION
INSTALLING A NEUTRIK CONNECTOR ON A POWER CABLE
Put bushing and chuck onto the cable.
Prepare cable as shown above. The power cable must be a three-conductor 2.5mm2
cable.
Insert the wire into the terminals and fasten the clamping device by a flat
screwdriver.
Push insert and chuck into housing (pay attention to the guiding keyway).
Fasten bushing.
The color-coding schemes and some possible pin identification schemes; if pins
are not clearly identified, or if you have any doubts about proper
installation, consult a qualified electrician.
The power cable must be a three-conductor 2.5mm2 cable.
When the voltage is 110V, do not connect more than 10 lightings in total to AC
mains power in one interconnected daisy chain.
When the voltage is 220V, do not connect more than 20 lightings in total to AC
mains power in one interconnected daisy chain.
Wire color | Conductor | Symbol |
---|---|---|
Brown | Live | L |
Blue | Neutral | N |
Yellow/green | ground |
PHYSICAL INSTALLATION
This lighting can be placed on a horizontal surface such as a stage or clamped
to a truss or similar rigging structure in any orientation using a rigging
clamp.
When suspending the fixture above ground level, verify that the structure can
hold at least 10 times the weight of all installed devices.
Verify that all external covers and rigging hardware are securely fastened and
use an approved means of secondary attachment such as a safety cable.
CONTROL PANNEL
Rotating the “Mode” knob to setting the main menu, press to enter.
Rotating the “Manual” knob to setting the sub menu, press to esc.
After the setting, you can rotate the Manual knob for CCT and linear dimmer.
MENU MAP
DMX PROTOCOL
DMX512 STD CHANNEL MODE (2-WAY LED)
DMX CHANNEL
CH | Name | Value | Function |
---|---|---|---|
CH1 | Dimmer | 000←→255 | Dimmer from 0% to 100% |
CH2 | Warm white | 000←→255 | Warm white |
CH3 | Cool white | 000←→255 | Cool white |
DMX CHANNEL STROBE
CH | Name | Value | Function |
---|---|---|---|
CH1 | Dimmer | 000←→255 | Dimmer from 0% to 100% |
CH2 | Strobe | 000←→009 |
010←→255
| No strobe
Strobe from slow to fast
CH3| Warm white| 000←→255| Warm white
CH4| Cool white| 000←→255| Cool white
DMX512 EXT CHANNEL MODE (2-WAY LED)
DMX CHANNEL
CH | Name | Value | Function |
---|---|---|---|
CH1 | Dimmer | 000←→255 | Dimmer from 0% to 100% |
CH2 | Color temperature | 000←→009 |
010←→255
| No function CT from 3200K to 5600K
DMX CHANNEL STROBE
CH | Name | Value | Function |
---|---|---|---|
CH1 | Dimmer | 000←→255 | Dimmer from 0% to 100% |
CH2 | Strobe | 000←→009 |
010←→255
| No strobe
Strobe from slow to fast
CH3| Color temperature| 000←→009| No function
MEETING CHANNEL MODE (NEED CONTROL BY SPECIAL CONTROL BOX)
MEETING CHANNEL
CH | Name | Value | Function |
---|---|---|---|
CH1 | Dimmer | 000←→255 | Dimmer from 0% to 100% |
CH2 | Color temperature | 000←→255 | 3200K ~ 5600K Color temperature= 8Bit * 256 |
- 16Bit
CH3| Color temperature| 000←→255| 3200K ~ 5600K Color temperature= 8Bit * 256 - 16Bit
MEETING CHANNEL STROBE
CH | Name | Value | Function |
---|---|---|---|
CH1 | Dimmer | 000←→255 | Dimmer from 0% to 100% |
CH2 | Color temperature | 000←→255 | 3200K ~ 5600K Color temperature= 8Bit * 256 |
- 16Bit
CH3| Color temperature| 000←→255| 3200K ~ 5600K Color temperature= 8Bit * 256 - 16Bit
LUX CHART
COMMON INSTRUCTION
The light uses international 3 pins DMX signal cannon for DMX in and DMX out;
The light uses blue LCD display to show the parameter. If there is no DMX in,
the display will show the information which you can check from the menu map.
In fact, the light has 2 DMX channels modes, please refer the DMX channel
chart.
This light uses full aluminum shell for the heat dissipation, and electronic
temperature detection to ensure the proper operation of the circuit at any
time.
This light is only for indoor use, when you install it by hanging, please use
the safety cable to ensure the safety.
If you have any questions, please contact our support department.
TECHNICAL SPECIFICATION
Input voltage: AC100~240V, 50/60Hz.
Power consumption: 120W
Light output power : 100W for every color
Light source : 200W high power bicolor led lamp
LED life : 50,000 hours
Color temperature : 3200 K-5600K.
CRI : Ra (CRI)≥95, R9≥90, TLCI≥95
Optics : 15–35-degree linear manual zoom
Dimming : 0-100% linear dimming
Channel : 2CH, 3CH, 4CH based on different mode
Control mode : wired DMX /manual control.
Control panel : TFT color display screen & two dimming knobs.
Central illumination: 5 meters 4760LUX (5600K, 15 °)
Protection class : IP20
Working temperature: -25℃~ +40℃
Shell material: aluminum alloy
APPENDIX
Problem and solution
Problem | Reason | Resolution |
---|---|---|
Device does not work | No power | AC100-240V, 50/60Hz Check the power |
connection, and make sure device connect the mains in well condition.
Check if the fuse is good.
LED Bulb is off| LED bulb damaged| Replacing LED module
LED drive board damaged| Replacing LED drive board
Temperature switches damaged| Replacing temperature switch
Caution