FORTRESS 57336 Air Compressor Instruction Manual
- June 17, 2024
- FORTRESS
Table of Contents
ULTRA QUIET SERIES
AIR COMPRESSOR
57336 Air Compressor
57336
26 GALLON
OIL FREE
PORTABLE
Owner’s Manual & Safety Instructions
Save This Manual Keep this manual for the safety warnings and precautions,
assembly, operating, inspection, maintenance and cleaning procedures. Write
the product’s serial number in the back of the manual (or month and year of
purchase if product has no number). Keep this manual and the receipt in a safe
and dry place for future reference.
Visit our website at: http://www.harborfreight.com email our technical
support at:
productsupport@harborfreight.com
When unpacking, make sure that the product is intact and undamaged. If any
parts are missing or broken, please call
1-888-866-5797 as soon as possible.
Copyright© 2023 by Harbor Freight Tools® . All rights reserved.
No portion of this manual or any artwork contained herein may be reproduced in
any shape or form without the express written consent of Harbor Freight Tools.
Diagrams within this manual may not be drawn proportionally. Due to continuing
improvements, actual product may differ slightly from the product described
herein.
Tools required for assembly and service may not be included.
WARNING
Read this material before using this product.
Failure to do so can result in serious injury.
SAVE THIS MANUAL.
WarninG SyMBOlS anD DeFinitiOnS
****| This is the safety alert symbol. It is used to alert you to potential
personal injury hazards. Obey all safety messages that follow this symbol to
avoid possible injury or death.
---|---
| Indicates a hazardous situation which, if not avoided, will result in death
or serious injury.
| Indicates a hazardous situation which, if not avoided, could result in death
or serious injury.
| Indicates a hazardous situation which, if not avoided, could result in minor
or moderate injury.
| Addresses practices not related to personal injury.
IMPORTANT SAFETY INFORMATION
General Safety Warnings
WarninG read all safety warnings and instructions.
Failure to follow the warnings and instructions may result in electric shock,
fire and/or serious injury.
Save all warnings and instructions for future reference.
The warnings, precautions, and instructions discussed in this instruction
manual cannot cover all possible conditions and situations that may occur. It
must be understood by the operator that common sense and caution are factors
which cannot be built into this product, but must be supplied by the operator.
-
Work area safety
a. Keep work area clean and well lit. Cluttered or dark areas invite accidents.
b. Do not operate the compressor in explosive atmospheres, such as in the presence of flammable liquids, gases or dust. Compressor motors produce sparks which may ignite the dust or fumes.
c. Keep children and bystanders away from an operating compressor. -
electrical safety
a. compressor plugs must match the outlet. never modify the plug in any way. Do not use any adapter plugs with grounded compressors. Standard plugs and matching outlets will reduce risk of electric shock.
b. Do not expose compressor to rain or wet conditions. Water entering a compressor will increase the risk of electric shock.
c. Do not abuse the cord. never use the cord for unplugging the compressor. Keep cord away from heat, oil, sharp edges or moving parts. Damaged or entangled cords increase the risk of electric shock. -
personal safety
a. Stay alert, watch what you are doing and use common sense when operating this compressor. Do not use this compressor while you are tired or under the influence of drugs, alcohol or medication. A moment of inattention while operating a compressor
may result in serious personal injury.
b. Use personal protective equipment. always wear anSi-approved eye protection during setup and use.
c. prevent unintentional starting. ensure the switch is in the off-position before connecting to power source or moving the compressor. -
compressor use and care
a. Do not use the compressor if the switch does not turn it on and off. Any compressor that cannot be controlled with the switch is dangerous and must be repaired.
b. Disconnect the plug from the power source before making any adjustments, changing accessories, or storing the compressor. Such preventive safety measures reduce the risk of starting the compressor accidentally.
c. Store an idle compressor out of the reach of children and do not allow persons unfamiliar with the compressor or these instructions to operate it. A compressor is dangerous in the hands of untrained users.
d. Maintain the compressor. Keep the compressor clean for better and safer performance. Follow instructions for lubricating and changing accessories. Keep dry, clean and free from oil and grease. check for misalignment or binding of moving
parts, breakage of parts and any other condition that may affect the compressor’s operation. if damaged, have the compressor repaired before use. Many accidents are caused by a poorly maintained compressor.
e. Use the compressor in accordance with these instructions, taking into account the working conditions and the work to be performed. Use of the compressor for operations different from those intended could result in a hazardous situation. -
Service
a. Have your compressor serviced by a qualified repair person using only identical replacement parts. This will ensure that the safety of the compressor is maintained.
air compressor Safety Warnings
- risk of fire or explosion – do not spray flammable liquid in a confined area or towards a hot surface. Spray area must be well-ventilated. Do not smoke while spraying or spray where spark or flame is present. arcing parts – keep compressor at least 20 feet away from explosive vapors, such as when spraying with a spray gun.
- risk of bursting – do not adjust regulator higher than marked maximum pressure of attachment.
- risk of injury – do not direct air stream at people or animals.
- Do not use to supply breathing air.
- Do not leave compressor unattended for an extended period while plugged in. Unplug compressor after working.
- Keep compressor well-ventilated. Do not cover compressor during use.
- Drain Tank daily and after use. Internal rust causes tank failure and explosion.
- Do not remove the valve cover or adjust internal components.
- Compressor head gets hot during operation. Do not touch it or allow children nearby during or immediately following operation.
- Do not use the air hose to move the compressor.
- Release the pressure in the storage tank before moving.
- The use of accessories or attachments not recommended by the manufacturer may result in a risk of injury to persons.
- All air line components, including hoses, pipe, connectors, filters, etc., must be rated for a minimum working pressure of 150 PSI, or 150% of the maximum system pressure, whichever is greater.
- USE OF AN EXTENSION CORD IS NOT RECOMMENDED. If you choose to use an extension cord, use the following guidelines:
TABle a: recOMMenDeD MiniMUM Wire GaUGe FOr eXtenSiOn cOrDS (120 VOlt)NAMEPLATE AMPERES (at full load)| EXTENSION CORD LENGTH
---|---
25′| 50′| 100′| 150′
0 – 6| 18| 16| 16| 14
6/1/10| 18| 16| Do not use.
10.| 16| 16| Do not use.
12.| 14| 12| Do not use.
a. Make sure your extension cord is in good condition.
b. Be sure to use an extension cord which is heavy enough to carry the current
your product will draw. An undersized cord will cause a drop in line voltage
resulting in loss of power and overheating. Table A shows the correct size to
use depending on cord length and nameplate ampere rating. If in doubt, use the
next heavier gauge. The smaller the gauge number, the heavier the cord.
- Industrial applications must follow OSHA guidelines.
- Maintain labels and nameplates on the compressor. These carry important safety information. If unreadable or missing, contact Harbor Freight Tools for a replacement.
- This product is not a toy. Keep it out of reach of children.
- People with pacemakers should consult their physician(s) before use. Electromagnetic fields in close proximity to heart pacemaker could cause pacemaker interference or pacemaker failure.
SAVE THESE INSTRUCTIONS.
Grounding
WARNING
TO PREVENT ELECTRIC SHOCK AND DEATH FROM INCORRECT GROUNDING WIRE
CONNECTION:
Check with a qualified electrician if you are in doubt as to whether the
outlet is properly grounded. Do not modify the power cord plug provided with
the compressor.
Never remove the grounding prong from the plug. Do not use the compressor if
the power cord or plug is damaged. If damaged, have it repaired by a service
facility before use. If the plug will not fit the outlet, have a proper outlet
installed by a qualified electrician.
110-120 VAC Grounded Compressors: Compressors with Three Prong Plugs
-
In the event of a malfunction or breakdown, grounding provides a path of least resistance for electric current to reduce the risk of electric shock.
This compressor is equipped with an electric cord having an equipment- grounding conductor and a grounding plug. The plug must be plugged into a matching outlet that is properly installed and grounded in accordance with all local codes and ordinances. -
Do not modify the plug provided — if it will not fit the outlet, have the proper outlet installed by a qualified electrician.
-
Improper connection of the equipment-grounding conductor can result in a risk of electric shock. The conductor with insulation having an outer surface that is green with or without yellow stripes is the equipment-grounding conductor. If repair or replacement of the electric cord or plug is necessary, do not connect the equipment- grounding conductor to a live terminal.
-
Check with a qualified electrician or service personnel if the grounding instructions are not completely understood, or if in doubt as to whether the compressor is properly grounded.
-
Use only 3-wire extension cords that have 3-prong grounding plugs and 3-pole receptacles that accept the compressor’s plug.
-
Repair or replace damaged or worn cord immediately.
125 VAC 3-Prong Plug and Outlet (for up to 125 VAC and up to 15 A) -
This compressor is intended for use on a circuit that has an outlet that looks like the one illustrated above in 125 VAC 3-Prong Plug and Outlet. The compressor has a grounding plug that looks like the plug illustrated above in 125 VAC 3-Prong Plug and Outlet.
-
The outlet must be properly installed and grounded in accordance with all codes and ordinances.
-
Do not use an adapter to connect this compressor to a different outlet.
For technical questions, please call
1-888-866-5797.
Symbology
PSI | Pounds per square inch of pressure |
---|---|
CFM | Cubic Feet per Minute flow |
SCEM | Cubic Feet per Minute flow at standard conditions |
NPT | National pipe thread, tapered |
NPS | National pipe thread, straight |
| Double Insulated
| Volts
| Alternating Current
| Amperes
Specifications
Electrical Rating | 120VAC / 60Hz / 14A |
---|---|
Air Outlet Size | 1/4″ -18 NPT |
Air Pressure | Shut-off |
Restart | 135 PSI |
Air Tank Capacity | 26 Gallons |
Air Flow Capacity | 4.5 SCFM @ 90 PSI |
Sound Level | 69 dBA @ 3′ |
NOtice: to prevent damage to air tools, tank Output pressure is regulated to 155 pSi +/- 5 pSi.
Installation
** Read the entire iMpOrtant SaFety inFOrMatiOn section at the beginning of
this manual including all text under subheadings therein before set up or use
of this product.
WARNING
TO PREVENT SERIOUS INJURY FROM ACCIDENTAL OPERATION:
Turn the power Switch “OFF” and unplug the air compressor from its electrical
outlet before assembling or making any adjustments to the compressor.
Note: For additional information regarding the parts listed in the
following pages, refer to the Assembly Diagram near the end of this manual.
Functions**
Assembly
Attach Wheels
- After unboxing, leave compressor on base inside of tray. Fold down edges of tray and attach Wheels.
- Attach Wheels to brackets on Tank (7) using Axle Bolts (1), Flat Washers (3), Spring Washers (4), and Nuts (5).
Attach Hose Hook
Hose Hook (11) can be installed on either side of Compressor.
- Remove Cap Nuts (12) from either side of Compressor.
- Place Hose Hook over Bolts (14) and secure with Cap Nuts.
Breaking in the Compressor
- Turn the Power Switch OFF and unplug Power Cord.
- Fully open Drain Valve.
- Plug in the Power Cord.
- Turn the Power Switch ON (AUTO).
- Let the unit run for 30 minutes. Air will expel freely through the Drain Valve.
- Turn the Power Switch OFF.
- Unplug the Power Cord and close Drain Valve.
Air Connection Setup
-
Connect a regulator valve, an inline shut off valve and a 1/4″ NPT air hose to the Quick Coupler (all sold separately). The air hose must be long enough to reach the work area with enough extra length to allow free movement while working.
Note: An in-line shutoff ball valve is an important safety device because it controls the air supply even if the air hose is ruptured. The shutoff valve should be a ball valve because it can be closed quickly. -
Depending on the tool that will be used with this compressor, incorporate additional components, such as an in-line oiler, a filter, or a dryer (all sold separately), as shown on Figure A on page 8 and Figure B on page 9. Consult air tool’s manual for needed accessories.
| Description| Function
---|---|---
A| Air Hose| Connects air to tool
B| Filter| Prevents dirt and condensation from damaging tool or workpiece
C| Regulator| Adjusts air pressure to tool
D| Lubricator (optional)| For air tool lubrication
E| Coupler and Plug| Provides quick connection and release
F| Leader Hose (optional)| Increases coupler life
G| Air Cleaner / Dryer (optional)| Prevents water vapor from damaging
workpiece
H| Air Adiusfing Valve (optional)| For fine tuning airflow at tool
| Description| Function
---|---|---
A| Vibration Pads| For noise and vibration reduction
B| Anchor Bolts| Secures air compressor in place
C| Ball Valve| Isolates sections of system for maintenance
D| Isolation Hose| For vibration reduction
E| Main Air Line – 314″ minimum recommended| Distributes air to branch lines
F| Ball Valve| To drain moisture from system
G| Branch Air Line -1/2′ minimum recommended| Brings air to point of use
H| Air Hose| Connects air to tool
I| Filter| Prevents dirt and condensation from damaging tool or workpiece
J| Regulator| Adjusts air pressure to tool
K| Lubricator (optional)| For air tool lubrication
L| Coupler and Plug| Provides quick connection and release
M| Leader Hose (optional)| Increases coupler life
N| Air Cleaner I Dryer (optional)| Prevents water vapor from damaging
workpiece
0| Air Adiustinq Valve (optional)| For fine tuning airflow at tool
Operating Instructions
**** Read the ENTIRE IMPORTANT SAFETY INFORMATION section at the beginning of this manual including all text under subheadings therein before set up or use of this product.
Compressor Area Set Up
- Designate a work area that is clean and well-lit. The work area must not allow access by children or pets to prevent injury.
- Locate the Compressor on a flat level surface to ensure proper pump lubrication and to prevent damage to the unit. Keep at least 12″ of space around the unit to allow air circulation.
- Route the power cord from the compressor to the grounded wall outlet, along a safe path without creating a tripping hazard or exposing the power cord to possible damage.
General Operation
-
Close the Drain Valve.
-
Close the in-line shutoff valve between the compressor and the air hose.
-
Plug the Power Cord into a grounded 120 VAC electrical outlet.
-
Pull the ring on Safety Valve to release pressure.
-
Turn the Power Switch ON (AUTO) .
-
Allow the Air Compressor to build up pressure until it cycles off.
Note: At the beginning of the day’s first use of the Air Compressor, check for air leaks by applying soapy water to connections while the
Air Compressor is pumping and after pressure cutout. Look for air bubbles. If air bubbles are present at connections, tighten connections. Do not use the Air Compressor unless all connections are air tight, the extra air leaking out will cause the compressor to operate too often, increasing wear on the compressor.
Note: As long as the Power Switch is ON (AUTO), the operation of the Air Compressor is automatic, controlled by an internal pressure switch. The Compressor will turn on automatically when the air pressure drops to 135 PSI, and will turn off automatically when the air pressure reaches 175 PSI.
WARNING! TO PREVENT SERIOUS INJURY AND DEATH FROM EXPLOSION: Do not adjust the internal pressure switch. Any change to the automatic pressure levels may cause excess pressure to accumulate, causing a hazardous situation. -
Pull out the Regulator and adjust so that the air output is enough to properly power the tool, but the output will not exceed the tool’s maximum air pressure at any time. Turn the knob clockwise to increase the pressure and counter-clockwise to decrease pressure. Adjust the pressure gradually, while checking the air output gauge to set the pressure. Push in Regulator when finished.
-
Make sure the air tool’s throttle or switch is in the off position. Connect the air tool to the air hose.
-
Open the in-line shutoff valve.
-
Use the air tool as needed.
-
After the job is complete, turn the Power Switch OFF.
-
Unplug the Air Compressor.
-
Close the in-line shutoff valve.
-
Bleed air from the tool then disconnect the tool.
-
Drain Tank according to Draining Moisture from the Tank on page 12.
-
Clean, then store the Air Compressor indoors.
Emergency Depressurization
If it is necessary to quickly depressurize the Compressor, turn the Power
Switch OFF.
Then, pull on the ring on the Safety Valve to quickly release stored air
pressure.
Automatic Shut off System
-
If the Compressor automatically shuts off before reaching its normal cutoff pressure:
a. Shut off all tools.
b. . Turn Power Switch OFF.
c. Unplug Compressor.
D . Wait until the Compressor cools down (about 10 minutes);
e. Plug in Compressor.
f. Turn Power Switch ON (AUTO).
g. Resume operation -
Possible causes of repeated automatic shut off of the compressor are:
a. Using an extension cord that is too long or narrow;
b. An air leak or open hose causing the compressor ; to cycle too often and build up heat.
c. Turning Air Compressor off and in to ickly. on again too quickly. -
Correct any issues before further use to avoid damage to the compressor.
Maintenance and Servicing
**** Procedures not specifically explained in this manual must be performed
only by a qualified technician.
WARNING
TO PREVENT SERIOUS INJURY FROM ACCIDENTAL OPERATION:
Turn the Power Switch “OFF” and unplug the Compressor from its electrical
outlet before performing any inspection, maintenance, or cleaning procedures.
TO PREVENT SERIOUS INJURY FROM COMPRESSOR FAILURE:
Do not use damaged equipment. If abnormal noise or vibration occurs, have the
problem corrected before further use.
Cleaning, Maintenance, and Lubrication
-
BeFOre eacH USe, inspect the general condition of the air compressor. Check for:
• loose hardware,
• misalignment or binding of moving parts,
• cracked or broken parts,
• damaged electrical wiring, and
• any other condition that may affect its safe operation. -
AFter USe, wipe external surfaces of the compressor with a clean cloth.
-
**WarninG!** tO preVent SeriOUS inJUry: if the supply cord of this compressor is damaged, it must be replaced only by a qualified service technician.
Maintenance Schedule
Following are general guidelines for maintenance checks of the Air Compressor.
note: The environment in which the compressor is used, and the frequency
of use will affect how often you will need to check the Air Compressor
components and perform maintenance procedures.
Daily:
a. Make sure all nuts and bolts are tight.
b. Drain moisture from air tank.
c. Check for abnormal noise or vibration.
d. Check for air leaks. *
e. Wipe off any oil or dirt from the compressor.
Weekly:
a. Inspect Air Filter.
Monthly:**
a. Inspect Safety Valve.
-
To check for air leaks, apply soapy water to joints while the Air Compressor is pressurized. Look for air bubbles.
To clean the compressor surface, wipe with a damp cloth, using a mild detergent or mild solvent.
Draining Moisture from the tank
** The Drain Valve is located under the Tank. It must be used daily to release all trapped air and moisture from the Tank. Doing this will eliminate condensation and prevent tank corrosion.- Turn the Power Switch off.
- Place a collection pan under the Drain Valve.
- Turn the Drain Valve to open it. Tilt Compressor forward to drain.
- When all the pressure and moisture are released, close the Drain Valve.
air Filter Maintenance
Check the Air Filter weekly to see if it needs replacement. Replace the filter
more often if compressor is used in dirty environments.
- Remove the Cover.
- Remove the Air Filter.
- Check Filter for accumulated dirt.
- To prevent injury from dust and debris, wear ANSI-approved safety goggles, NIOSHapproved dust mask/respirator, and heavy-duty work gloves. In a well-ventilated area away from bystanders, use pressurized air (no more than 15 PSI) to blow dust out of the filter.
- Replace Air Filter. Replace with new Air Filter as needed.
- Replace the Cover.
Troubleshooting
Problem | Possible Causes | Likely Solutions |
---|
Compressor does
not start or restart| 1 Tank(s) already pressurized.
2 Power cord not plugged in properly.
3.Incorrect power supply.
4.No power at outlet.
5.Building power supply circuit tripped or blown fuse.
6.Cord wire size is too small or cord is too long to properly power
compressor.
7.Compressor needs service.| 1.No problem. Compressor will start when needed.
2.Check that cord is plugged in securely.
3.Check that circuit matches compressor requirements.
4.Reset circuit breaker. or have outlet serviced by a qualified technician.
5.Reset circuit or replace fuse. Check for low voltage conditions. It may be
necessary to disconnect other electrical appliances from the circuit or move
the compressor to its own circuit.
6.Use larger diameter or shorter extension cord or eliminate extension cord.
See Recommended Wire Gauge for Extension Cords in Safety section.
7.Have unit inspected by a qualified technician.
Compressor builds pressure too slowly| 1.Incorrect power supply.
2.Working environment too cold.
3.Safety valve leaking.
4.Loose fittings.| 1.Check that circuit matches compressor requirements.
2.Move compressor to a warmer location.
3.Listen for air leaking from valve.
If leaking. replace with identical valve with same rating. DO NOT SEAL OR
TAMPER WITH SAFETY VALVE.
4 Reduce air pressure. then check all fittings with a soap solution
for air leaks and tighten as needed. Do not overtighten.
Compressor not building enough air pressure| 1.Air filter needs cleaning.
2.Check Valve needs service.
3.Compressor not large enough for job.
4.Loose fittings.
5.Hose or hose connections too narrow.
6.High altitude reducing air output.| 1 Check air filter and clean as needed.
2.Have technician clean or replace. as needed.
3.Check if accessory CFM is met by Compressor. If Compressor cannot supply
enough
air flow (CFM). use a larger Compressor.
4 Reduce air pressure. then check all fittings with a soap solution
for air leaks and tighten as needed. Do not overtighten.
5.Replace with wider hose and/or hose connections.
6.Higher altitudes require compressors with greater output.
Overheating| 1.Air filter needs cleaning.
2.Unusually dusty environment.
3.Extension cord used.| 1.Check air filter and clean as needed.
2.Clean filter more often or move unit to cleaner environment.
3.Eliminate extension cord.
Compressor starts and stops excessively| 1, Loose fittings.
2. Compressor not large enough for job.| 1.Reduce air pressure. then check
all fittings with a soap solution for air leaks and tighten as needed. Do not
overtighten.
2.Check if accessory CFM is met by Compressor. If Compressor cannot supply
enough
air flow (CFM). use a larger Compressor.
Excessive noise| Loose fittings.| Reduce air pressure. then check all fittings
with a soap solution for air leaks and tighten as needed. Do not overtighten.
Moisture in discharge air| Too much moisture in air.| Install inline air
filter/dryer. and/or relocate to less humid environment.
Safety Valve ‘pops”| Safety valve needs service.| Pull on test ring of safety
valve. If it still pops. replace.
Air leaks from pump or fittings| Loose fittings.| Reduce air pressure. then
check all fittings with a soap solution for air leaks and tighten as needed.
Do not overtighten.
Air leaks from tank| Defective or rusted tank.| Have tank replaced by a
qualified technician.
Drain moisture from tank daily to prevent future corrosion.
**** Follow all safety precautions whenever diagnosing or servicing the
compressor. Disconnect power supply before service.
Parts List and Diagram
PLEASE READ THE FOLLOWING CAREFULLY
THE MANUFACTURER AND/OR DISTRIBUTOR HAS PROVIDED THE PARTS LIST AND ASSEMBLY
DIAGRAM IN THIS MANUAL AS A REFERENCE TOOL ONLY. NEITHER THE MANUFACTURER OR
DISTRIBUTOR MAKES ANY REPRESENTATION OR WARRANTY OF ANY KIND TO THE BUYER THAT
HE OR SHE IS QUALIFIED TO MAKE ANY REPAIRS TO THE PRODUCT, OR THAT HE OR SHE
IS QUALIFIED TO REPLACE ANY PARTS OF THE PRODUCT. IN FACT, THE MANUFACTURER
AND/OR DISTRIBUTOR EXPRESSLY STATES THAT ALL REPAIRS AND PARTS REPLACEMENTS
SHOULD BE UNDERTAKEN BY CERTIFIED AND LICENSED TECHNICIANS, AND NOT BY THE
BUYER. THE BUYER ASSUMES ALL RISK AND IABILITY ARISING OUT OF HIS OR HER
REPAIRS TO THE ORIGINAL PRODUCT OR REPLACEMENT PARTS THERETO, OR ARISING OUT
OF HIS OR HER INSTALLATION OF REPLACEMENT PARTS THERETO.
Parts list
Part | Description | Qty |
---|---|---|
1 | Axle Bolt | 2 |
2 | Wheel | 2 |
3 | Flat Washer | 2 |
4 | Spring Washer | 2 |
5 | Nut | 2 |
6 | Drain Valve | 1 |
7 | Tank | 1 |
8 | Screw | 2 |
9 | Flat Washer | 2 |
10 | Rubber Foot | 2 |
11 | Hose Hook | 1 |
12 | Cap Nut | 4 |
13 | Nut | 4 |
14 | Hex Bolt | 8 |
15 | Base | 1 |
16 | Shock Pad | 4 |
17 | Check Valve | 1 |
18 | Pump Assembly | 1 |
19 | Exhaust Hose | 1 |
20 | Exhaust Connector | 1 |
21 | Cold Start Valve | 1 |
22 | Cylinder Head Cover Base | 1 |
23 | Cylinder Head Cover | 1 |
24 | Screw | 2 |
25 | Air Filter | 2 |
26 | Cover | 2 |
27 | Sealing Ring | 2 |
28 | Tube | 1 |
29 | Power Switch | 1 |
30 | Handle Grip | 2 |
31 | Screw | 2 |
32 | Capacitor Cover | 1 |
33 | Capacitor | 2 |
34 | Terminal B | 1 |
35 | Frame | 1 |
36 | Power Cord | 2 |
37 | Hose | 1 |
38 | Safety Valve | 1 |
39 | Tank Gauge | 1 |
40 | Pressure Regulator Valve Assembly | 1 |
41 | Regulator | 1 |
42 | Outlet Gauge | 1 |
43 | Air Outlet | 1 |
44 | Pressure Regulator Panel | 1 |
45 | Screw | 2 |
46 | Lock Washer | 4 |
47 | Outer Lock Washer | 4 |
Record Product’s Serial Number Here:
Note: If product has no serial number, record month and year of purchase
instead.
Note: Some parts are listed and shown for illustration purposes only, and
are not available individually as replacement parts. Reference UPC
193175514516.
Assembly Diagram
Limited 90 Day Warranty
Harbor Freight Tools Co. makes every effort to assure that its products meet
high quality and durability standards, and warrants to the original purchaser
that this product is free from defects in materials and workmanship for the
period of 90 days from the date of purchase. This warranty does not apply to
damage due directly or indirectly, to misuse, abuse, negligence or accidents,
repairs or alterations outside our facilities, criminal activity, improper
installation, normal wear and tear, or to lack of maintenance. We shall in no
event be liable for death, injuries to persons or property, or for incidental,
contingent, special or consequential damages arising from the use of our
product. Some states do not allow the exclusion or limitation of incidental or
consequential damages, so the above limitation of exclusion may not apply to
you. THIS WARRANTY IS EXPRESSLY IN LIEU OF ALL OTHER WARRANTIES, EXPRESS OR
IMPLIED, INCLUDING THE WARRANTIES OF MERCHANTABILITY AND FITNESS.
To take advantage of this warranty, the product or part must be returned to us
with transportation charges prepaid. Proof of purchase date and an explanation
of the complaint must accompany the merchandise. If our inspection verifies
the defect, we will either repair or replace the product at our election or we
may elect to refund the purchase price if we cannot readily and quickly
provide you with a replacement. We will return repaired products at our
expense, but if we determine there is no defect, or that the defect resulted
from causes not within the scope of our warranty, then you must bear the cost
of returning the product.
This warranty gives you specific legal rights and you may also have other
rights which vary from state to state.
26677 Agoura Road
Calabasas, CA 91302
1-888-866-5797
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>