Product Information
Specifications
- Main function: Heating/Cooling
- Size: Not specified
Technical Parameters
- Power supply: Not specified
- Sensor: Included
- Humidifying: Yes
- Heating: Yes
Panel Instruction
The panel instruction is not provided in the text extract. Please refer to
the user manual for detailed panel instructions.
Heating/Cooling Mode Setting
To set the heating or cooling mode:
- Refer to the wiring diagram to correctly connect the power supply and sensor.
- Set the desired mode by using the designated buttons or controls on the device.
- The indicator light will display the current mode (On for refrigeration/heating, Off for no operation, Flash for compressor delay).
Humidification/Dehumidification Mode Setting
To set the humidification or dehumidification mode:
- Refer to the wiring diagram to correctly connect the power supply, sensor, and humidifier (if applicable).
- Set the desired mode by using the designated buttons or controls on the device.
- The indicator light will display the current mode (On for humidification, Off for no operation).
Indicator Light Status Instruction
The indicator lights on the device provide information about temperature, humidity, and settings:
- Temperature indicator light: Displays the current temperature.
- Humidity indicator light: Displays the current humidity level.
- Set indicator light: Indicates the status of parameter settings (On for setting in progress).
Error Description
The device has built-in error alarm functions to notify users of any issues:
-
Sensor error: If the sensor is open circuit or short circuit, the device will activate the sensor error alarm mode. All running operations will be stopped, and the nixie tube will display “EE”.
Press any key to cancel the alarm sound and return to normal temperature display when the error is cleared. -
Temperature measurement exceeding range: If the measuring temperature exceeds the temperature measuring range, the device will activate the error alarm function. All running operations will be stopped, and the nixie tube will display “HH”. Press any key to cancel the alarm sound and return to normal working mode when the temperature is within the measuring range.
Safety Regulations
To ensure safe usage of the product, please adhere to the following safety regulations:
- Danger:
- Strictly distinguish the sensor down-lead, power wire, and output relay interface to prevent wrong connections or overloading of the relay.
- Prohibit connecting wire terminals without electricity cut-off.
- Warning: Prohibit using the machine under the environment of over damp, high temperature, strong electromagnetism interference, or strong corrosion.
- Notice:
- The power supply should conform to the voltage value indicated in the instruction.
- To avoid interference, keep a proper distance between the sensor down-lead and power wire.
FAQ
Q: How do I contact customer support?
A: For any other situations or inquiries, please feel free to contact us
via email at sales@aideepen.com.
Main function Specification and size Technical parameters
Panel instruction
Any other situations, please feel free to contact us via email: sales@aideepen.com
Heating/cooling mode setting
Wiring diagram
1 2 3 4 5 6 7 8 9 10
Blue Yellow Green
Red
Power supply
Sensor
Humidifying Heating
Humidification/Dehumidification mode setting
Blue Yellow Green Red
Sensor
Blue Yellow Green Red
Sensor
Indicator light status instruction
Indicator light Temperature
indicator Humidity indicator
Set indicator light
Function
On:Refrigeration/Heating starts;Off :Refrigeration /Heating
stops;Flash:compressor delay On: humidification starts; off : humidification
stops
On:parameter setting status
Note Cool,Heat indicator light can not be”on” status simultaneously
Error description
Alarm when sensor error: Controller activate the sensor error alarm mode when
sensor open circuit or short circuit, all the running status is closed off
with the buzzer alarms, and the nixie tube displays”EE”, press any key can
cancel alarm sound,system back to display the normal temperature when the
error and the fault is cleared.
Alarm when the measuring temperature exceeds temperature measuring range:
Controller activates the error alarm function when the measuring temperature
exceeds the temperature measuring range, all the running status is closed off
with the buzzer alarms, and the nixie tube displays”HH”, Press any key can
cancel alarm sound, system back to display the normal working mode when the
temperature restore to normal measuring range.
Safety Regulations
Danger: 1. Strictly distinguish the sensor down-lead, power wire and output
relay interface from one another, and prohibit wrong connections or
overloading the relay
2. Dangers: Prohibit connecting the wire terminals without electricity cut-
off
Warning: Prohibit using the machine under the environment of over damp, high
temp., strong electromagnetism interference or strong corrosion. Notice: 1.
The power supply should conform to the voltage value indicated in the
instruction. 2. To avoid the interference, the sensor down-lead and power wire
should be kept a proper distance.