AIDEEPEN SHT-2000 Temperature and Humidity Controller Instruction Manual

June 17, 2024
Aideepen

AIDEEPEN SHT-2000 Temperature and Humidity Controller

AIDEEPEN-SHT-2000-Temperature-and-Humidity-Controller

Product Information

Specifications

  • Main function: Heating/Cooling
  • Size: Not specified

Technical Parameters

  • Power supply: Not specified
  • Sensor: Included
  • Humidifying: Yes
  • Heating: Yes

Panel Instruction
The panel instruction is not provided in the text extract. Please refer to the user manual for detailed panel instructions.

Heating/Cooling Mode Setting
To set the heating or cooling mode:

  1. Refer to the wiring diagram to correctly connect the power supply and sensor.
  2. Set the desired mode by using the designated buttons or controls on the device.
  3. The indicator light will display the current mode (On for refrigeration/heating, Off for no operation, Flash for compressor delay).

Humidification/Dehumidification Mode Setting
To set the humidification or dehumidification mode:

  1. Refer to the wiring diagram to correctly connect the power supply, sensor, and humidifier (if applicable).
  2. Set the desired mode by using the designated buttons or controls on the device.
  3. The indicator light will display the current mode (On for humidification, Off for no operation).

Indicator Light Status Instruction

The indicator lights on the device provide information about temperature, humidity, and settings:

  • Temperature indicator light: Displays the current temperature.
  • Humidity indicator light: Displays the current humidity level.
  • Set indicator light: Indicates the status of parameter settings (On for setting in progress).

Error Description

The device has built-in error alarm functions to notify users of any issues:

  • Sensor error: If the sensor is open circuit or short circuit, the device will activate the sensor error alarm mode. All running operations will be stopped, and the nixie tube will display “EE”.
    Press any key to cancel the alarm sound and return to normal temperature display when the error is cleared.

  • Temperature measurement exceeding range: If the measuring temperature exceeds the temperature measuring range, the device will activate the error alarm function. All running operations will be stopped, and the nixie tube will display “HH”. Press any key to cancel the alarm sound and return to normal working mode when the temperature is within the measuring range.

Safety Regulations

To ensure safe usage of the product, please adhere to the following safety regulations:

  • Danger:
    1. Strictly distinguish the sensor down-lead, power wire, and output relay interface to prevent wrong connections or overloading of the relay.
    2. Prohibit connecting wire terminals without electricity cut-off.
  • Warning: Prohibit using the machine under the environment of over damp, high temperature, strong electromagnetism interference, or strong corrosion.
  • Notice:
    1. The power supply should conform to the voltage value indicated in the instruction.
    2. To avoid interference, keep a proper distance between the sensor down-lead and power wire.

FAQ

Q: How do I contact customer support?
A: For any other situations or inquiries, please feel free to contact us via email at sales@aideepen.com.

Main function Specification and size Technical parameters
Panel instruction

Any other situations, please feel free to contact us via email: sales@aideepen.com

Heating/cooling mode setting

Wiring diagram

1 2 3 4 5 6 7 8 9 10

Blue Yellow Green
Red

Power supply

Sensor

Humidifying Heating

Humidification/Dehumidification mode setting

Blue Yellow Green Red
Sensor

Blue Yellow Green Red
Sensor

Indicator light status instruction

Indicator light Temperature
indicator Humidity indicator
Set indicator light

Function

On:Refrigeration/Heating starts;Off :Refrigeration /Heating stops;Flash:compressor delay On: humidification starts; off : humidification stops
On:parameter setting status

Note Cool,Heat indicator light can not be”on” status simultaneously

Error description
Alarm when sensor error: Controller activate the sensor error alarm mode when sensor open circuit or short circuit, all the running status is closed off with the buzzer alarms, and the nixie tube displays”EE”, press any key can cancel alarm sound,system back to display the normal temperature when the error and the fault is cleared.
Alarm when the measuring temperature exceeds temperature measuring range: Controller activates the error alarm function when the measuring temperature exceeds the temperature measuring range, all the running status is closed off with the buzzer alarms, and the nixie tube displays”HH”, Press any key can cancel alarm sound, system back to display the normal working mode when the temperature restore to normal measuring range.

Safety Regulations

Danger: 1. Strictly distinguish the sensor down-lead, power wire and output relay interface from one another, and prohibit wrong connections or overloading the relay
2. Dangers: Prohibit connecting the wire terminals without electricity cut- off
Warning: Prohibit using the machine under the environment of over damp, high temp., strong electromagnetism interference or strong corrosion. Notice: 1. The power supply should conform to the voltage value indicated in the instruction. 2. To avoid the interference, the sensor down-lead and power wire should be kept a proper distance.