ALLEN HEATH XONE-96 Dj Mixer Instruction Manual

June 17, 2024
ALLEN HEATH

ALLEN HEATH XONE-96 Dj Mixer

ALLEN HEATH-XONE-96-Dj-Mixer-product

Product Information

  • Specifications
    • Product Name: XONE:96 XFADER
    • Manufacturer: ALLEN&HEATH
    • Model: [mini innoFADER]
  • Description
    • The XONE:96 XFADER is a high-quality fader designed to be used with the XONE:96 mixer.
    • It features the mini innoFADER technology, which provides smooth and precise control over audio mixing.
    • The fader is calibrated to ensure accurate performance and can be adjusted according to user preferences.
  • Features
    • Precision control for audio mixing
    • Smooth and accurate performance
    • Calibration options for customization
  • Compatibility
    • The XONE:96 XFADER is compatible with the XONE:96 mixer.

Product Usage Instructions

  • Section 1: Initial Setup
    • Ensure that the XONE:96 mixer is powered on and connected to the audio system.
    • Place the XONE:96 XFADER in the designated fader slot on the mixer.
    • Make sure the mixer and the XFADER are properly connected using the provided cables.
  • Section 2: XFADER Calibration
    • Access the calibration mode on the XONE:96 mixer. This can usually be done through the mixer’s settings menu.
    • Follow the on-screen instructions or refer to the XONE:96 user manual to enter the XFADER calibration mode.
    • While in the calibration mode, adjust the XFADER position to its lowest point (usually -∞).
    • Move the XFADER to its highest point (usually +6dB) and mark this position on the mixer.
    • Return the XFADER to its lowest point and mark this position as well.
    • Using a suitable screwdriver, adjust the calibration trim potentiometer located near the XFADER to align the marked positions with the desired audio levels (e.g., -∞ and +6dB).
    • Repeat the calibration process if necessary until the XFADER accurately corresponds to the marked positions.
    • Exit the calibration mode and test the XFADER’s performance by moving it smoothly between its lowest and highest points. The audio levels should match the marked positions on the mixer.
  • Section 3: Maintenance
    • To maintain optimal performance of the XONE:96 XFADER, follow these guidelines:
    • Regularly clean the XFADER using a soft cloth and mild cleaning solution.
    • Avoid exposing the XFADER to excessive moisture or liquids.
    • Protect the XFADER from dust and debris by covering it when not in use.
    • Avoid placing heavy objects on top of the XFADER to prevent damage.
  • Frequently Asked Questions (FAQ)
    • Q: Can I use the XONE:96 XFADER with other mixers?
    • A: The XONE:96 XFADER is specifically designed for use with the XONE:96 mixer. It is recommended to use it with compatible devices for optimal performance.
    • Q: How often should I calibrate the XFADER?
    • A: Calibration is typically a one-time process, but it may need to be repeated if the XFADER’s performance becomes inaccurate or inconsistent.

XFADER CALIBRATION

XONE: 96 XFADER CALIBRATION

  • If adjustment of the XONE:96 XFADER cut-in point is required when new, or after replacing the standard Mini innoFADER.
  • Calibration requires the use of a T8, Torx, and slotted (flat-blade) screwdriver.
  • Place the mixer face-down on a clean surface.
  • Remove and retain two (2) Torx screws securing the front panel to the base of the mixer [1].
  • Turn the mixer over. Remove and retain six (6) Torx screws securing the front panel to the top and chassis [2].ALLEN HEATH-XONE-96-Dj-Mixer-fig-1 \(2\)
  • Loosen, but do not remove, two (2) Torx screws securing the top panel sides to the mixer chassis [3]
  • With care, pull the front panel away from the mixer and place face down in front of the chassis.
  • The XFADER calibration potentiometer is located on the right side of the mixer as shown [4]ALLEN HEATH-XONE-96-Dj-Mixer-fig-1 \(3\)ALLEN HEATH-XONE-96-Dj-Mixer-fig-1 \(4\)
  • Turn the corresponding channel fader up and monitor the LR MIX output (via headphones, MST, or BOOTH output)
  • Using a flat-headed driver, turn the XFADER calibration pot (clockwise) until the audio signal only just cuts OUT.ALLEN HEATH-XONE-96-Dj-Mixer-fig-1 \(5\)
  • Check that the XFADER travels ≤1mm towards the X position before the audio signal cuts back IN.
  • Turn the corresponding channel fader down.ALLEN HEATH-XONE-96-Dj-Mixer-fig-1 \(6\)
  • Turn the corresponding channel fader UP and monitor the LR MIX output
  • Using a slotted (’flat-blade’) driver, turn the XFADER calibration pot (clockwise) until the audio signal only just cuts OUTALLEN HEATH-XONE-96-Dj-Mixer-fig-1 \(7\)
  • Again, check the XFADER travels ≤1mm, toward the Y position, before the audio signal cuts IN
  • Turn the corresponding channel fader down.
  • Next, route audio to two mix channels, assigning one to X side of the XFADER and the other to Y, and check the XFADER function and different XFADER curve switch options to confirm adjustment is complete.
  • Finally, replace the front panel, re-fit, and retighten all screws securing the front panel to the chassis and top panel.