FS COM M6200 Network Management Unit User Guide

June 4, 2024
FS COM

FS COM Logo M6200 Network Management Unit
User Guide
FS COM M6200 Network Management Unit

Introduction

FS M6200 Series Platform provides a managed, flexible, and scalable architecture for fiber networks.
It can support EDFA, OEO, OLP, DCM, and other M6200 Series Infrastructure Modules to construct a multi-service optical transmission network platform.

FS COM M6200 Network Management Unit - Fig 1

M6200 Series Platform Overview

M6200 Series Infrastructure Modules

  1. Slot Card TypeFS COM M6200 Network Management Unit - Fig 2FS COM M6200 Network Management Unit - Fig 3
  2. Slot Card TypeFS COM M6200 Network Management Unit - Fig 4

NOTE:

  1. M6200 series modules are designed as 1-slot card types or 2-slot card types to match the managed chassis.
  2. 1-slot module: OEO, DWDM EDFA, OLP, DWDM Red/Blue Filter, DCM(40km), OSC, NMU, etc.
  3. 2-slot module: MUX, DEMUX, DCM(80km).

M6200 Series Managed Chassis

FS COM M6200 Network Management Unit - Fig 5

Chassis Type Chassis Slot
M6200-CH2U 7pcs
M6200-CH5U 15pcs

Accessories

FS COM M6200 Network Management Unit - Fig 6FS
COM M6200 Network Management Unit - Fig 7

DWDM Mux Demux Module

FS COM M6200 Network Management Unit - Fig 8

Front Panel Port

Port Port Type Description
C21-C60 LC/UPC Mux/Demux Channel Port
OUT Optical Singal Output Port
IN Optical Singal Input Port
MON Input/Output Optical Power Monitoring Port

DWDM EDFA (Erbium Doped Fiber Amplifier)FS COM M6200 Network Management
Unit - Fig 9 Front Panel Port

Port Port Type Description
VOA Port SFP Optical Power Attenuation Adjusting Port for SFP VOA
OUT LC/UPC Optical Signal Output Port
IN Optical Signal Input Port
OSCO Optical Supervisory Channel Output Port
OSCI Optical Supervisory Channel Input Port
MON Optical Signal Monitoring Port
CONSOLE Micro USB Debugging & Upgrading Port

Front Panel LED

LED Alarm State Normal State Description
ALM Always-ON:
There is an alarm about the power supply, the fan, or the NMU module. Light
OFF Module State Alarm

Quick Flash:
The module type does not match.
RUN| Always OFF:
The module is not normally enabled.| Slow Flash| Module Run
IN| Always Red:
There is a LOS alarm at the port.| Always Green| Input Optical Power Alarm
OUT| Always OFF:
The port is not enabled.

10G OEO Transponder

FS COM M6200 Network Management Unit - Fig 10 Front Panel Port

Port Port Type Description
Port 1~10 SFP/SFP+ Optical Transceiver Signal Transmitting Port

Front Panel LED

LED Status Description
SYS Slow Flash of Green Light There is no alarm in the module.
Quick Flash of Red Light The module type does not match.
Slow Flash of Red Light There is an alarm in the module.
Always Red The module is enabled.
1~10 Always Green There is no LOS alarm at the port.
Always Red There is a LOS alarm at the port.
Always OFF The port is disabled.

Signal Protocol

Service Type Rate
STM-1 SDH Service 155.52Mbit/s
STM-4 622.08Mbit/s
STM-16 2.488Gbit/s
STM-64 9.95Gbit/s
ESCON SAN Service 200Mbit/s
FC100 1.06Gbit/s
FC200 2.12Gbit/s
DVB-ASI. SDL Digital TV Service 270Mbit/s
HD-SDI HDTV Service 1.485Gbit/s
GE Ethernet Service 1.25Gbit/s
FE 125Mbit/s
CPRI Option1 0.6144Gbit/s
CPRI Option2 1.2288Gbit/s
CPRI Option3 2.4576Gbit/s
10GE LAN 10.31Gbit/s
10GE WAN 9.95Gbit/s
OTU2 OTN Service 10.71Gbit/s
OTU2e 11.1Gbit/s

100G OEO Transponder

FS COM M6200 Network Management Unit - Fig 11

Front Panel Port

Port Port Type Description
Port 1~6 QSFP+/QSFP28 40/100Gbps Optical Transceiver Signal

Transmitting Port

Front Panel Port

LED Status Description
ALM Always Red There is an alarm for the Power, Fan, and NMU modules.
Quick Flash of Red Light The module type does not match.
Always OFF There is no alarm in the module.
RUN Slow Flash of Green Light The module is normal.
Always OFF The module does not work.
1~6 Always Green There is no LOS alarm at the port.
Always Red There is a LOS alarm at the port.
Quick Flash of Red Light The transceiver does not match.
Always OFF The port is disabled.

DCM (Dispersion Compensation Module)

FS COM M6200 Network Management Unit - Fig 12

Front Panel Port

Port Port Type Description
IN LC/UPC Optical Signal Input Port
OUT Optical Signal Output Port

OSC Module (Optical Supervisory Channel Module)FS COM M6200 Network
Management Unit - Fig 13 Front Panel Port

Port Port Type Description
IN1/2 LC/UPC Transmission Line Side Optical Singal Input Port
OUT1/2 Transmission Line Side Optical Singal Output Port
OSCI1/OSCI2 Optical Supervisory Channel Input Port
OSCO1/OSCO2 Optical Supervisory Channel Output Port
TX1/2 WDM Demultiplexing Optical Singal Input Port
RX1/2 WDM Multiplexing Optical Singal Output Port

1+1 OLP (Optical Line Protection)FS COM M6200 Network Management Unit -
Fig 14 Front Panel Port

Port Port Type Description
TX/RX LC/UPC Input/Output Port Connected to the Transmission Equipment
T1/R1 Main Optical Signal Transmitting Port/Receiving Port
T2/R2 Backup Optical Signal Transmitting Port/Receiving Port
CONSOLE Micro USB Debugging & Upgrading Port

Panel Key Instruction

Key Function Description
AUTO/FORCE Press for switching auto mode or manual mode Switching

Working Mode
PRI/SEC| Press for switching work channel of primary/second state| Switching Working Channel

Front Panel LED

LED Status Description
ALM Always-ON There is an alarm in the sub-module.
Quick Flash The module type does not match.
Always OFF The alarm does not exist.
RUN Slow Flash The module works normally.
Always OFF The module is not normally enabled.
A/F Always-ON The module is in automatic mode.
Always OFF The module is in manual mode.
P/S Always-ON The line is in the primary channel state.
Always OFF The line is in a secondary channel state.
TX/R1/R2 Always-ON The line power is normal.
Always OFF The line power is lower than the threshold.

Managed ChassisFS COM M6200 Network Management Unit - Fig
15 Front Panel Port

Slots Description
NMU Module Network Management Unit(NMU), the main control module of the

chassis
Blank Plate 1| Used for 1+1 NMU module backup or M6200 series business module
Blank Plate 2~7| Used for 1-slot/2-slot M6200 series business module
Fan| Support field-replaceable and hot-swappable
AC Power| AC power supply, 90VAC~264VAC, 45Hz~65Hz, supports 1+1 backup

FS COM M6200 Network Management Unit - Fig 16 Front Panel Port

Slots Description
NMU Module Network Management Unit(NMU), the main control module of the

chassis
Blank Plate 1| Only used for 1+1 NMU module backup
Blank Plate 2~15| Used for 1-slot/2-slot M6200 series business module
Fan| Support field-replaceable and hot-swappable
AC Power| AC power supply, 110VAC~260VAC, 45Hz~65Hz, supports 1+1 backup

Networking Management UnitFS COM M6200 Network Management Unit - Fig
17 Front Panel Port

Port Port Type Rate Description
MGMT 1~4 RJ45 ETH 10/100M
Auto-negotiate 1. Connect to the local network management computer

2. Interface for NMS concatenation equipment
MGMT5~6| SFP| 100M| Out of band OSC management
CONSOLE| RJ45 ETH| /| Debugging & Upgrading port

Front Panel LED

LED Status Description
ALM Always-ON There is an alarm on the power supply, the fan, or the

NMU Module.
Always OFF| There is no alarm.
RUN| Quick Flash| The module works normally.
Always OFF| The module is not normally enabled.
ACT| Always-ON| The module is the primary module.
Always OFF| The module is the second module.

Site Environment
Keep the equipment indoors. If it is in the rainy season or in a humid environment, dehumidification measures must be taken.
Ensure there is no water on the storage floor and no leakage to the packing box of the equipment.
Avoid automatic fire fighting facilities, heating systems,s and other places where leakage may occur.

Installing

Wearing ESD Wrist Strap

  1. FS COM M6200 Network Management Unit - Fig 18 Before touching any device or module, wear an ESD wrist strap or ESD gloves to protect sensitive components against electrostatic discharge from the human body.
  2. Connect another end of the ESD wrist strap to the PGND point on the chassis.

Installing Business ModuleFS COM M6200 Network Management Unit - Fig
19

  1. Hold the ejector levers on the front panel of the module and raise them.FS COM M6200 Network Management Unit - Fig 20
  2. Push the module gently along the guide rail until the module cannot go any further. Then lower the two ejector levers of the module.

Installing Mounting Brackets

FS COM M6200 Network Management Unit - Fig 21

  1. Secure the mounting brackets to the two sides of the M6200 series managed chassis with 8x M4 screws.

Rack Mounting

  1. Put the M6200 series managed chassis on the shelf in the cabinet.
  2. Install and tighten the panel with 4 sets of M6 screws.
  3. The cable manager can be installed together with mounting brackets to the cabinet.

Grounding the M6200 Series Managed Chassis

FS COM M6200 Network Management Unit - Fig 23

  1. Secure the grounding lug to the grounding point on the chassis front panel with the washers and screws.
  2. Connect the other end of the cable to a proper earth ground, such as the rack in which M6200 series is mounted.

**CAUTION:** The earth connection must not be removed unless all supply connections have been disconnected.

Connecting Power Cord

FS COM M6200 Network Management Unit - Fig 24

  1. Plug the AC power cord into the power port on the front panel of the AC power module.
  2. Connect the other end of the power cord to an AC power source.

WARNING: Do not install power cables while the power is on.
Connecting to the Management Ports
SFP Management PortFS COM M6200 Network Management Unit - Fig
25

  1. Plug the compatible SFP transceiver into the SFP port on the front of the NMU module.
  2. Connect a fiber optic cable to the transceiver. Then connect the other end of the cable to another fiber device, such as a switch.

RJ45 Management port

FS COM M6200 Network Management Unit - Fig 26

  1. Connect one end of the standard RJ45 Ethernet cable to the MGMT1&2 port on the front of the NMU module.
  2. Connect the other end of the cable to a computer.

NOTE:

  1. SFP management port is designed for long-haul management of more than 100m.
  2. The RJ45 management port is designed for short-haul management of less than 100m.
  3. You can start your management by selecting one of the above six management ports.

Configuring the M Series Platform

Configuring the M Series Platform Using the Web-based interface
Step 1: Connect your computer with the network cable to any Ethernet MGMT port of the NMU module.
Step 2: Get the NMS software from the CD of chassis accessories or download the file “NMS software” online, and then install it. Step 3: Double Click “NMS Server” icon on the desktop and the dialogue box of license validation will pop up. Enter the license key (included in the CD) to finish validation. (If you can’t find the license key, please contact the FS sales manager for help.)

FS COM M6200 Network Management Unit - Fig 28 Step 4: Then the NMS server interface pops up. Double-click “Start NMS Server” to run the server, when it prompts “Please connect your client to the web server on port: 9090”, it means that you have successfully started the NMS server. And then you can close the NMS Server window, the server is still running in the background.FS COM M6200 Network Management Unit - Fig
29 Step 5: Open a browser window. (Recommend IE11.0 and above version or Google Chrome browser).

  1. If you log in from the local NMS host, enter localhost:9090 in the address bar to open the login interface.
  2. If you log in from another remote host, enter the server IP address XXX.XXX.XXX.XXX:9090 (IP address of NMS server) to open the login interface.

Step 6: Enter the correct user name and password (For the administrator, the default login user name is “root”, and the default password is “public”), as shown in the figure below:FS COM M6200 Network Management Unit - Fig
30 Step 7: Click login, you are now ready to configure M series platform
NOTE: Refer to the M SERIES NETWORK MANAGEMENT USER MANUAL online for further information

Troubleshooting

Module LEDs Working Abnormally

  1. Check the power cable connections at the M6200 series managed chassis and the power source.
  2. Make sure that all cables are used correctly and comply with the power specifications.
  3. Make sure that business modules are in the right position in the M6200 series managed chassis.

Accessing the Web-based Configuration Page Unsuccessfully

  1. Check the MGMT ports LED on the NMU module and make sure the Ethernet cable is connected properly.
  2. Try another port on the NMU module and make sure the Ethernet cable is suitable and works normally.
  3. Power off the M6200 series managed chassis. After a while, power it on again.
  4. Make sure the IP address of your NMS server is correctly configured.
  5. If you still cannot access the configuration page, please reinitialize the NMS server to its factory defaults.

Business Module Cannot Be Added

  1. Enter through CMD.
  2. Ping business module IP to check whether it can communicate.
  3. Check whether normal communication can be made between the business module and the NMU module.
  4. Change another business module.

Online Resources

Download: https://www.fs.com/download.html
Help Center: https://www.fs.com/service/help_center.html
Contact Us: https://www.fs.com/contact_us.html

Product Warranty

FS ensures our customers that for any damaged or faulty items due to our workmanship, will o er a free return within 30 Days from the day you receive your goods. This excludes any custom-made items or tailored solutions.
Warranty: M6200 series enjoy 2 years limited warranty against defect in materials or workmanship. For more details about the warranty, please check at :
https://www.fs.com/policies/warranty.html
Return: If you want to return the item(s), information on how to return can be found at: https://www.fs.com/policies/day_return_policy.html

Compliance Information

FCC
Note: This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures:

  • Reorient or relocate the receiving antenna.
  • Increase the separation between the equipment and the receiver.
  • Connect the equipment to an outlet on a circuit different from that to which the receiver is connected.
  • Consult the dealer or an experienced radio/TV technician for help.

This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions:

  1. This device may not cause harmful interference, and
  2. This device must accept any interference received, including interference that may cause undesired operation.

CAUTION:
Any changes or modifications not expressly approved by the grantee of this device could void the user’s authority to operate the equipment.
Responsible party (only for FCC matters)
FS.COM Inc.
380 Centerpoint Blvd, New Castle, DE 19720, United States
https://www.fs.com
CE
FS.COM GmbH hereby declares that this device is in compliance with Directive 2014/30/EU. A copy of the EU Declaration of Conformity is available at www.fs.com/company/quality_control.html
FS.COM LIMITED
24F, Infore Center, No.19, Haitian 2nd Rd,
Binhai Community, Yuehai Street,Nanshan
District, Shenzhen City
FS.COM GmbH
NOVA Gewerbepark Building 7, Am
Gfild 7, 85375 Neufahrn bei Munich, Germany

Q.C. PASSED
Copyright © 2021 FS.COM All Rights Reserved.