Introduction
Thank you for choosing FS S5500-48T6SP-R PoE+ Switch. This guide is designed to familiarize you with the layout of the switch and describes how to deploy the switch in your network.
Accessories
Hardware Overview
Front Panel Ports
Ports | Description |
---|---|
RJ45 | 10/100/1000BASE-T ports for Ethernet connection |
SFP+ | Hot swap SFP+ ports for 1/10G connection |
CON | A baud rate of 9600bps |
Front Panel Button
Buttons | Description |
---|---|
SWAP | Swap function, used to switch POE indication. |
Front Panel LEDs
LEDs | Status | Description |
---|---|---|
PWR | On | The switch is powered on. |
SYS | On | The system is being started up. |
Blink | The system works normally. | |
POE | On | The port is linked. |
Off | The port is not linked. |
Back Panel
Site Environment
Make sure that the site environment is well-ventilated, the heat of electrical
devices is well-discharged and sufficient air circulation is provided for device
cooling.
Avoid to damage devices by following the electrostatic discharge prevention
procedure.
Ensure that there is adequate air flow around the switch. Make sure the machine
box is sealed because the opened machine box will reverse the cool air flow.
Mounting the Switch
Desk Mounting
- Attach four rubber pads to the bottom.
- Place the chassis on a desk.
Rack Mounting
- Fix the mounting brackets to the two sides of the switch with six M3 screws.
- Attach the switch to the rack with four M6 screws and cage nuts.
Grounding the Switch
- Connect one end of the grounding cable to a proper earth ground, such as the rack in which the switch is mounted.
- Fix the grounding lug to the grounding point on the back panel of the switch with washers and screws.
CAUTION: The earth connection cannot be removed unless all supply onnections have been disconnected.
Connecting the Power
- Plug the AC power cord into the power port on the back panel of the switch.
- Connect the other end of the power cord to an AC power source.
CAUTION: Do not install power cables while the power is on.
Connecting the Console Port
- Connect the console port and the terminal or PC’s serial port through specific console cable.
- Run terminal emulation software, such as super Windows terminal.
Connecting the RJ45 Port
- Connect an Ethernet cable to the RJ45 port of IP cameras, IP telephones, Access Points (AP), or other network devices.
- Connect the other end of the Ethernet cable to the RJ45 port of the switch.
Connecting SFP+ Ports
- Plug the compatible SFP+ transceiver into the SFP+ port.
- Connect a fiber cable to the fiber transceivers. Then connect the other end of the cable to network routers or other fiber devices.
WARNING: Laser beams will cause eye damage. Do not look into bores of optical modules or optical fibers without eye protection.
Stacking the S5500-48T6SP-R PoE+ Switch
The S5500-48T6SP-R PoE+ switch support stacking up to 8 units between the same
model together.
It can be physically stacked using optical fiber cables connected to SFP+
tranceivers, or 10G Direct
Attach Cables(DAC). Any 2 SFP+ ports on rear panel of the switch can be used
for physical stacking.
Configuring the Switch
Configuring the Switch Using the Web-based Interface
Step 1: Connect your computer to any Ethernet port of the switch with the
network cable.
Step 2: Set up the IP confguration on your computer. The IP address of
your computer should be set in the same subnet addresses of the switch. The IP
address is 192.168.1.x (“x” is any number from 2 to 254).
Step 3: Open a browser. Enter the default IP address of the switch
http://192.168.1.1.
Step 4: When the login page appears, choose the language you need and
enter the username and password(admin/admin).
You are now ready to configure the switch. Refer to the S5500-48T6SP-R PoE+
switch Configuration Guide online for further information.
Configuring the Switch Using the Console Port
Step 1: Connect a computer to the switch’s console port with the supplied
console cable.
Step 2: Start the terminal simulation software such as HyperTerminal on
the computer.
Step 3: Configure the terminal simulation with the following parameters:
- 9600 bits per second
- 8 data bits
- 1 stop bit
- no sum check bit
- no traffic control
Step 4: Enter the username and password(admin/admin).
CAUTION: Be sure to save settings before exiting the software.
Troubleshooting
Power LED Working Abnormally
-
Check the power cable connections at the switch and the power outlet and whether the power
on-off is at “ON” location. -
Make sure that all cables are used correctly and comply with the Ethernet specifications.
HyperTerminal Displaying Abnormally
- Make sure the power supply is normal and the console cable is properly connected.
- Check whether the console cable is the right type.
- Check whether the control cable driver is properly installed on the computer.
- Ensure the parameters of the HyperTerminal are correct.
Accessing the Web-based Configuration Page Unsuccessfully
- Check every port and LED on the switch and make sure the Ethernet cable is connected properly.
- Try another port on the switch and make sure the Ethernet cable is suitable and works normally.
- Power off the switch for a while, then power it on again.
- Make sure the IP address of your PC is set within the subnet of the switch.
- If you still cannot access the configuration page, please restore the switch to its factory defaults.
Then the IP address of your PC should be set as 192.168.1.x (“x” is any number from 2 to 254) and Subnet Mask as 255.255.255.0.
Online Resources
- Download https://www.fs.com/products_support.html
- Help Center https://www.fs.com/service/fs_support.html
- Contact Us https://www.fs.com/contact_us.html
Product Warranty
FS ensures our customers that if there are any damage or faulty items due to
our workmanship, we will offer a free return within 3 months from the day you
receive your goods. This excludes any custom made items or tailored solutions.
Warranty: This product enjoys 2 years limited warranty against defect in
materials or workmanship. For more details about warranty, please check at
https://www.fs.com/policies/warranty.html
Return: If you want to return item(s), information on how to return can be
found at https://www.fs.com/policies/day_return_policy.html
Compliance Information
FCC
Note: This equipment has been tested and found to comply with the limits
for a Class A digital device, pursuant to part 15 of the FCC Rules. These
limits are designed to provide reasonable protection against harmful
interference when the equipment is operated in a commercial environment. This
equipment generates, uses, and can radiate radio frequency energy and, if not
installed and used in accordance with the instruction manual, may cause
harmful interference to radio communications.
Operation of this equipment in a residential area is likely to cause harmful
interference in which case the user will be required to correct the
interference at his own expense.
This device complies with part 15 of the FCC Rules. Operation is subject to
the following two conditions:
- This device may not cause harmful interference, and
- this device must accept any interference received, including interference that may cause undesired operation.
CAUTION:
Any changes or modifications not expressly approved by the grantee of this
device could void the user’s authority to operate the equipment.
Responsible party (only for FCC matter)
FS.COM Inc.
380 Centerpoint Blvd, New Castle, DE 19720, United States
https://www.fs.com
CE
FS.COM GmbH hereby declares that this device is in compliance with the
Directive 2014/30/EU and 2014/35/EU. A copy of the EU Declaration of
Conformity is available at
www.fs.com/company/quality_control.html
FS.COM LIMITED
24F, Infore Center, No.19, Haitian 2nd Rd,
Binhai Community, Yuehai Street,Nanshan
District, Shenzhen City
FS.COM GmbH
NOVA Gewerbepark Building 7, Am
Gfild 7, 85375 Neufahrn bei Munich, Germany
Q.C. PASSED
Copyright © 2022 FS.COM All Rights Reserved.
References
- FS.com - HPC, Data Center, Enterprise, Telecom
- HPC, Data Centre, Enterprise, Telecom - FS.com United Kingdom
- HPC, Rechenzentrum, Unternehmen, Telekom - FS.com Deutschland
- FS.com - Data Center, Enterprise, Telecom
- Contact Us - FS.com
- Kontakt - FS.com Deutschland
- Rückgaberecht - FS.com Deutschland
- HPC, Rechenzentrum, Unternehmen, Telekom - FS.com Deutschland
- Technische Dokumente - FS.com Deutschland
- Hilfezentrum - FS.com Deutschland
- HPC, Datacenter, Enterprise, Télécom - FS.com France
- Comment Nous Contacter - FS.com France
- Politique de retour - FS.com France
- HPC, Datacenter, Enterprise, Télécom - FS.com France
- Documents techniques - FS.com France
- Centre d'aide - FS.com France
- Return Policy - FS.com
- Products Warranty - FS.com
- Technical Documents - FS.com
- Help Center - FS.com