Introduction
Multiplexing up to 40 channels over one fiber pair, it increases the bandwidth, capacity and maximizes the usefulness of fiber. A visual confirmation via LEDs shows that each channel and line are set up correctly.
FMU-AD402160M3
Accessories
Hardware Overview
Front Panel Ports
Ports | Port Type | Description |
---|---|---|
LINE | LC/UPC | Line side port. |
MON | 1% (2%, 3%, 5% can be customized) service signal monitoring Port. | |
OSC | Optical supervisory channel. | |
C21-C60 | Mux Demux channel ports. | |
1310NM | 1310nm service expansion port, channel bandwidth ±50nm. |
Front Panel LEDs
LEDs | Status | Description |
---|---|---|
PWR1/PWR2 | Solid Green | The power module works properly. |
Off | The power is o / The power supply module is NOT in the |
position.
RUN| Blinking Green| The system works properly.
Off| The system is powered off.
| Green| Optical power is within the threshold.
Yellow| Optical power is out of the threshold, and > -28dB.
Grey| Optical power < -28dB.
Back Panel
Back Panel Ports
Ports | Description |
---|---|
SFP | SFP ports for 1G connection. |
RJ45 | RJ45 ports for 10/100BASE-T Ethernet connection. |
Back Panel Button
Button | Description |
---|---|
RESET | Press the RESET button for 3-5 seconds to restore factory default |
settings.
The IP, user name, and login password are restored to the default state.
Back Panel LEDs
Ports | Status | Description |
---|---|---|
FAN | Solid Green | The fan works properly. |
Off | The fan is powered off. | |
PWR | Solid Green | The controller module works properly. |
Off | The controller module is powered off. | |
RUN | Blinking Green | The controller module system works properly. |
The controller module system is damaged.
Site Environment
- Keep the equipment indoors. If it is in rainy season or in humid environment, dehumidification measures must be taken.
- Ensure there is no water on the storage floor and no leakage to the packing box of the equipment.
- Avoid automatic fire fighting facilities, heating systems, and other places where leakage may occur.
Installing
Installing the Cable Management
- Install ve cable rings on the cable rack.
- Attach the cable manager to the front of the Mux Demux with plastic rivets.
Rack Mounting
- Place the Mux Demux on the rack.
- Install and tighten the panel with 4 sets of screws.
Installing the Ground Wire
- Use gaskets and screws to fix the ground plate to the fan at the end of the Mux Demux.
- Connect the other end of the ground cable to the appropriate connection.
CAUTION: The earth connection must not be removed unless all supply connections have been disconnected.
Connecting the Power Cord
- Plug the AC power cord into the power port on the back of the Mux Demux.
- Connect the other end of the power cord to an AC power source.
WARNING: Do not install power cables while the power is on.
Connecting the Channel Ports
- Connect a fiber optic cable to the DWDM SFP/SFP+ transceiver, or other WDM devices.
- Connect the other end of the fiber optic cable to the channel ports of Mux Demux.
- Check if the indicators light is green.
Connecting the RJ45 Ports
- Connect the ethernet cable to the RJ45 port on the Mux Demux.
- Connect the other end of ethernet cable to the computer for WEB management.
Connecting the SFP Ports
- Plug the compatible SFP transceiver into the SFP port.
- Connect a fiber optic cable to the fiber transceiver.
Active DWDM Mux Demux User Manual
Step1: Connect the computer to the RJ45 port of the Mux Demux using the
network cable.
Step2: Set the computer IP to the same network segment as 192.168.126.1, for
example, 192.168.126.XXX.
Step3: Open a browser, type 192.168.126.1, and enter the default username and
password, root/public.
Step4: WEB management and monitor the traffic of each channel online.
Click “Change Password” in the navigation bar, enter the new username and the new password to complete the account password modification.
Click “IP Config” in the navigation bar, enter the correct format of IP,
gateway, and subnet mask in turn to complete the modification of the above
parameters. After the IP is modified, enter the new
IP address to enter the client management interface.
Step1: Click the button on the upper right to switch to the List view.
Step2: Check one channel that needs to be modified, or check multiple or all
channels for batch modification, and click “Edit”.
Step3: Enter the correct threshold and remarks.
Step4: Click “Apply” to complete the modification.
Online Resources
- Download https://www.fs.com/download.html
- Help Center https://www.fs.com/service/help_center.html
- Contact Us https://www.fs.com/contact_us.html
Product Warranty
FS ensures our customers that any damage or faulty items due to our workmanship, we will offer a free return within 30 Days from the day you receive your goods. This excludes any custom-made items or tailored solutions.
Warranty: Active Mux Demux enjoy 3 years limited warranty against defect in
materials or workmanship. For more details about warranty, please check at :
https://www.fs.com/policies/warranty.html
Return: If you want to return item(s), information on how to return can be
found at :
https://www.fs.com/policies/day_return_policy.html
Compliance Information
FCC
Note: This equipment has been tested and found to comply with the limits
for a Class B digital device, pursuant to part 15 of the FCC Rules. These
limits are designed to provide reasonable protection against harmful
interference in a residential installation. This equipment generates, uses,
and can radiate radio frequency energy and, if not installed and used in
accordance with the instructions, may cause harmful interference to radio
communications. However, there is no guarantee that interference will not
occur in a particular installation. If this equipment does cause harmful
interference to radio or television reception, which can be determined by
turning the equipment off and on, the user is encouraged to try to correct the
interference by one or more of the following measures:
- Reorient or relocate the receiving antenna.
- Increase the separation between the equipment and receiver.
- Connect the equipment into an outlet on a circuit dierent from that to which the receiver is connected.
- Consult the dealer or an experienced radio/TV technician for help.
This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions:
- this device may not cause harmful interference, and
- this device must accept any interference received, including interference that may cause undesired operation.
CAUTION:
Any changes or modifications not expressly approved by the grantee of this
device could void the user’s authority to operate the equipment.
Responsible party (only for FCC matter) FS.COM Inc.
380 Centerpoint Blvd, New Castle, DE 19720, United States
https://www.fs.com
CE
FS.COM GmbH hereby declares that this device is in compliance with the
Directive 2014/30/EU and 2014/35/EU. A copy of the EU Declaration of
Conformity is available at
www.fs.com/company/quality_control.html
FS.COMLIMITED
24F, Infore Center, No.19, Haitian 2nd Rd, Binhai Community, Yuehai Street,
Nanshan District, Shenzhen City FS.COM GmbH
NOVA Gewerbepark Building 7, Am Gfild 7, 85375 Neufahrn bei Munich, Germany
Q.C. PASSED
Copyright © 2021 FS.COM All Rights Reserved.
References
- FS.com - HPC, Data Center, Enterprise, Telecom
- HPC, Data Centre, Enterprise, Telecom - FS.com United Kingdom
- HPC, Rechenzentrum, Unternehmen, Telekom - FS.com Deutschland
- FS.com - Data Center, Enterprise, Telecom
- Contact Us - FS.com
- Kontakt - FS.com Deutschland
- Technische Dokumente - FS.com Deutschland
- Rückgaberecht - FS.com Deutschland
- HPC, Rechenzentrum, Unternehmen, Telekom - FS.com Deutschland
- Hilfezentrum - FS.com Deutschland
- Technical Documents - FS.com
- HPC, Datacenter, Enterprise, Télécom - FS.com France
- Comment Nous Contacter - FS.com France
- Documents techniques - FS.com France
- Politique de retour - FS.com France
- HPC, Datacenter, Enterprise, Télécom - FS.com France
- Centre d'aide - FS.com France
- Return Policy - FS.com
- Products Warranty - FS.com