BIAMP CM1-6W Ceiling Microphone Connector Instruction Manual
- June 17, 2024
- biamp
Table of Contents
BIAMP CM1-6W Ceiling Microphone Connector
Ceiling Microphone Connector
Wiring Instructions
CM1-6W and CM1-6WS
June 2013
CEILING MICROPHONE CONNECTOR WIRING INSTRUCTIONS
PHOENIX CONNECTOR WIRING INSTRUCTIONS FOR CM1-6W and CM1-6WS CEILING MICROPHONES
-
Step 1 : Mount CM1-6W or CM1-6WS on ceiling tile using a 5/8″ hole.
-
Step 2 : Open back lid of junction box. Separate the supplied phoenix connector (male/female).
-
Step 3 : Insert external wire through strain relief nut, then connect the wire to the Phoenix terminal.
Recommended wire:
Belden 9451P – .124” O.D. or Belden 82761 – .116” O.D. -
Step 4 :
Wiring: -
= Ground
-
= Blue (+)
-
= Yellow (-)
-
Step 5 : Reconnect Phoenix terminals.
-
Step 6 : Tighten down the strain relief nut to hold wire firmly in place and close junction box lid.
CABLE STAY ASSEMBLY
- Wrap the cable around a beam, eyebolt or hanger. Next, slip the cable through the top of cable stay barrel pulling excess cable until taut.
- To release cable, depress the cable release pin on top, to release the loop, or on bottom, to extend cable length.