BENINCA BOB 50M Linear Worm Drive Swing Gate Motor Instruction Manual
- June 17, 2024
- BENINCA
Table of Contents
BENINCA BOB 50M Linear Worm Drive Swing Gate Motor
Overall dimensions
Wire diagram
Legenda:
- Motoreducer BOB50M
- Photo-electric cells FTC/FTM
- Key selector CH/TO.KEY (external) or digital keyboard
- Flash-light LAMPI
- Electronic board BRAIN/Head.
EC Declaration of Conformity
Manufacturer: Automatismi Benincà SpA.
Address: Via Capitello, 45 – 36066 Sandrigo (VI) – Italia
Herewith declares that: the operator for hinged gates model BOB50M /
BOB50ME.
is complying with provisions set forth by the following other EC Directive:
- DIRECTIVE 2004/108/EC OF THE EUROPEAN PARLIAMENT AND OF THE COUNCIL of 15 December 2004, on the harmonization of the laws of Member States relating to electromagnetic compatibility and which cancels Directive 89/336/EEC, according to the following harmonized regulations: EN 61000-6-2:2005, EN 61000-6-3:2007.
- DIRECTIVE 2006/95/EC OF THE EUROPEAN PARLIAMENT AND OF THE COUNCIL of 12 December 2006, on the harmonization of the laws of Member States relating to electrical equipment designed for use with certain voltage limits, according to the following harmonized regulations: EN 60335-1:2002 + A1:2004 + A11:2004 + A12:2006 + A2:2006 + A13:2008; EN 60335-1-103:2003.
Benincà Luigi, Legal responsible. Sandrigo, 10/06/2010.
WARNING
The product shall not be used for purposes or in ways other than those for
which the product is intended for and as described in this manual. Incorrect
uses can damage the product and cause injuries and damages.
The company shall not be deemed responsible for the non-compliance with a good
manufacture technique of gates as well as for any deformation, which might
occur during use.Keep this manual for further use. Qualified personnel, in
compliance with regulations in force, shall install the system. Packaging must
be kept out of reach of children, as it can be hazardous. For disposal,
packaging must be divided the various types of waste (e.g. carton board,
polystyrene) in compliance with regulations in force. The installer must
supply all information on the automatic, manual and emergency operation of the
automatic system and supply the end user with instructions for use. An
omnipolar switch/section switch with remote contact opening equal to, or
higher than 3mm must be provided on the power supply mains.. Make sure that
before wiring an adequate differential switch and an overcurrent protection is
provided. Pursuant to safety regulations in force, some types of installation
require that the gate connection be earthed. During installation, maintenance
and repair, cut off power supply before accessing to live parts. Descriptions
and figures in this manual are not binding. While leaving the essential
characteristics of the product unchanged, the manufacturer reserves the right
to modify the same under the technical, design or commercial point of view
without necessarily update this manual.
Introduction
- Before installing the system, read the instruction herein.
- It is mandatory not to use the BOB 5M / BOB 5ME item for applications different from those indicatedin the instructions herein.
- Supply the end user with instructions for using this system.
- The end user should receive special instruction manual.
- All Benincà items are covered by an insurance policy for damages and injuries caused by manufacture faults. It is however required that the machine bear the CE marking and original Benincà parts be used.
General information
To ensure a good operation of these automatic devices, the gate to be
automated should meet the following requirements:
- good strength and stiffness.
- hinges should have a minimum backlash and allow for smooth and regular manual operations.
- when closed, the gate leaves should correctly overlap for their entire height.
How to install the automatic system
Calculate the height of the system from the ground it is advisable to
define a position as much centred as possible with respect to the main door
and in correspondence with a strong cross girder). Weld the plate P, following
measures in Fig. 1.
- It is advisable to use an electric lock
With the door closed, weld bracket S to a cross beam of the main door or other element with equal strength, according to measures shown in Fig. 1. Keep in mind that, when carrying out this operation, the actuator should not be totally in a stroke end position. Remove the cover C by loosening the screw F. Then fix the actuator to the plate P by means of the screw T and the nut D (Fig. 2).
Lock the actuator to plate S by means of screw V and washer R. The holes in the acturator (Fig. 1a-1b) help to keep to the optimum installation measures.
How to adjust the mechanical stoppers
The actuator is provided with adjustable mechanical stoppers in the opening and closing phases. The system is adjusted by suitably positioning the “Open” and “Close” mechanical locks, as shown hereunder (Fig.3):
- Unlock the automatic system by using the special release lever, as shown in the instructions for the user (page 21-22).
- Close the door/gate leaf.
- Loosen screws V1 and move the “Close” lock until it reaches the pivot P, then tighten screws V1.
- Open the door/gate leaf.
- Loosen screws V2 and move the “Open” lock until it reaches the pivot P, then tighten screws V2.
- Reset the automatic operating mode.
In the BOB 5M version, two limit micro-switches are provided fixed to the mechanical stoppers. The micro-switches trigger slightly in advance with respect to the mechanical stop.
Connections
-
The special plate P (Fig. 4) allows for using a link for sheath or cable gland PG11, or PG13,5. Once the type of cable gland is applied to the plate, fix the latter to the adaptor cover by means of screws V.
-
Insert the cable, or cables, under the terminal board, as shown in Fig.5. This will leave enough space for the capacitor.
-
BOB 5M: carry out the wiring by referring to the wire diagram shown in Fig 6a (use both limit switches). In order to use either the opening limit switch or the mechanical stoppers, change wiring as shown in Fig. 6b (opening limit switch only) or 6c (mechanical stoppers only).
N.B: in wiring connections shown in Fig. 6a and 6b, the capacitor MUST NOT be connected to the control unit, while for wire connection shown in Fig. 6c, the capacitor can be connected to the control unit. -
BOB 5ME: carry out the wiring by referring to wire diagram shown in Fig 6d.
-
It is mandatory to provide for ground by using the special GND terminal.
1 | Close |
---|---|
2 | Open |
3 | COM |
4 | GND |
5 | ENCODER signal |
6 | ENCODER positive |
7 | ENCODER negative |
a | Black wire |
b | White wire |
c | Red wire |
FCC | CLOSE limit switch |
FCO | OPEN limit switch |
WARNING
The insurance policy, which covers any damages or injuries caused by
manufacture faults, requires that the installation comply with regulations in
force and Benincà original accessories be used.
TECHNICAL DATA
| BOB50M BOB50ME
---|---
Power supply| 230Vac 50/60Hz
Absorbed rating| 310 W
Absorbed current| 1,4 A
Thrust| 3500 N
Jogging| 40%
Protection degree| IP54
Operating temperature| -20°C / +70°C
Capacitor| 9 μF
Door leaf max. weight| 600 kg
Useful stroke:
- with 2 mechanical stoppers
- with 1 mechanical stopper
- without mechanical stoppers
| 455 mm
485 mm
520 mm
Translation speed| 0,7 m/min
Noise level| <70 dB
Lubrication| Permanent grease
Weight| 11,6 kg
Safety rules
- Do not stand in the movement area of the door.
- Do not let children play with controls and near the door.
- Should operating faults occur, do not attempt to repair the fault but call a qualified technician.
Manual and emergency operation
In the event of power failure or fault, to manually open and close the
door/gate, proceed as follows:
- open the protection door of the release device (Fig. A);
- introduce the special release key supplied and turn it by 90°, as shown by the arrow on the removable cover highlighted in Figure B;
- now the door can be opened/closed by hand;
- to reset the automatic operation, move the release key to the initial position;
- remove the release lever and close the protection door.
Maintenance
- Every month check the good operation of the emergency manual release.
- It is mandatory not to carry out extraordinary maintenance or repairs as accidents may be caused. These operations must be carried out by qualified personnel only.
- The operator is maintenance free but it is necessary to check periodically if the safety devices and the other components of the automation system work properly. Wear and tear of some components could cause dangers.
Waste disposal
- As indicated by the symbol shown, it is forbidden to dispose this product as normal urban waste as some parts might be harmful for environment and human health, if they are disposed of incorrectly.
Therefore, the device should be disposed in special collection platforms or given back to the reseller if a new and similar device is purchased. An incorrect disposal of the device will result in fines applied to the user, as provided for by regulations in force.
Warning
All Beninca products are covered by insurance policy for any possible damages
to objects and persons caused by construction faults under condition that the
entire system be marked CE and only Beninca parts be used.
n°| BOB50M / BOB50ME
Description| Cod.
---|---|---
1| Plastic cover| 9686630
2| Release lever| 9686631
3| Unblock. group| 9686632
4| Blister| 9686633
5| Motor| 9686634
6| Upper cover| 9686635
7| Gear| 9686636
8| Worm screw| 9686637
9| Lock with pin| 9686638
10| Lower cover| 9686639
11| Limit stop (Only BOB 5M)| 9686640
12| Locks| 9686641
13| Worm screw supp.| 9686642
14| Encoder
(Only BOB 5ME)| 9686516