BENINCA BOB2124 Swing Gate Motor Owner’s Manual
- June 13, 2024
- BENINCA
Table of Contents
BENINCA BOB2124 Swing Gate Motor
Product Information
Model | BOB2124 / BOB2124 E BOB3024 / BOB3024 E |
---|---|
Overall Dimensions | 796mm x 62mm |
Corsa (Stroke) | 270mm |
Mettere a livello (Leveling) | 660mm |
Interasse ancoraggi (Distance between axes of anchoring
bolts)| 88mm
Lunghezza anta (Door leaf width)| BOB2124: 1m, 1.5m, 2m, 2.1m
BOB3024: 1m, 1.5m, 2m, 2.5m, 3m
Poids porte (Door leaf weight)| BOB2124: 300kg, 250kg, 215kg, 200kg
BOB3024: 400kg, 350kg, 300kg, 250kg, 200kg
Tope en apertura (Opening stop)| 3
Tempo apertura (Opening time)| X: 115, Y: 105, Z: 80, K: 545, M: 50
X: 120, Y: 120, Z: 80, K: 540, M: 70
X: 135, Y: 135, Z: 80, K: 525, M*: 80
Grasso (Grease)| Mettere a livello (Leveling)
Rosetta 10×30 (Washer 10×30)| Posizione 1 (PG13,5)
Posizione 2 (PG11)
Product Usage Instructions
The power cables must be kept separated from the auxiliary cables. For cable length lower than 5m, use a cable 2×2.5sqmm. For cable length from 5 to 10 m use a cable 2x4sqmm. Cables longer than 10m are not recommended to connect control unit and motor.
Please refer to the following links for more information:
Overall dimensions
Max. wing length
BOB2124 – BOB 2124 E | BOB3024 – BOB 3024 E |
---|---|
Door leaf width | Door leaf weight t |
Longueur porte | Poids porte |
Longitud hoja
Dł. skrzydła
| Peso hoja
Ciężar skrzydła
| Longitud hoja
Dł. skrzydła
| Peso hoja
Ciężar skrzydła
(m)| (kg)| (m)| (kg)
1| 300| 1,0| 400
1,5| 250| 1,5| 350
2| 215| 2,0| 300
2,1| 200| 2,5| 250
—| —| 3,0| 200
BOB 21M / BOB 30M
1| – Marcia motore| – Motor gear| – Motorgang| – Marche moteur| –
Marcha motor| – Bieg silnika
2| + Marcia motore| + Motor gear| + Motorgang| + Marche moteur|
+ Marcha motor| + Bieg silnika
BOB 21ME / BOB 30ME
1| – Marcia motore| – Motor gear| – Motorgang| – Marche moteur| –
Marcha motor| – Bieg silnika
2| + Marcia motore| + Motor gear| + Motorgang| + Marche moteur|
+ Marcha motor| + Bieg silnika
3| Segnale ENCODER| ENCODER signal| ENCODER- Signal| Signal
ENCODEUR| Señal ENCODER| Sygnał ENKODERA
4| Positivo ENCODER| ENCODER positive| ENCODER Pluspol| Positif
ENCODEUR| Positivo ENCODER| Dodatni ENKODERA
5| Negativo ENCODER| ENCODER negative| ENCODER Minuspol| Négatif
ENCODER| Negativo ENCODER| Ujemny ENKODERA
Wire diagram
Legenda :
- Motoreducer
- Photo-electric cells
- Key selector (external) or digital keyboard
- Flash-light
- Antenna
- Electronic board.
The power cables must be kept separated from the auxiliary cables. For cable length lower than 5m, use a cable 2×2.5sqmm. For cable length from 5 to 10 m use a cable 2x4sqmm. Cables longer than 10m are not recommended to connect control unit and motor.
EC Declaration of Conformity
Manufacturer: Automatismi Benincà SpA.
Address: Via Capitello, 45 – 36066 Sandrigo (VI) – Italia
Herewith declares that: the operator for hinged gates model BOB 2124 / BOB2124
E / BOB 3024 / BOB 3024 E is complying with provisions set forth by the
following other EC Directive:
- DIRECTIVE 2004/108/EC OF THE EUROPEAN PARLIAMENT AND OF THE COUNCIL of 15 December 2004, on the harmonization of the laws of Member States relating to electromagnetic compatibility and which cancels Directive 89/336/EEC, according to the following harmonized regulations: EN 61000-6-2:2005, EN 61000-6-3:2007.
WARNING
The product shall not be used for purposes or in ways other than those for
which the product is intended for and as described in this manual. Incorrect
uses can damage the product and cause injuries and damages.
The company shall not be deemed responsible for the non-compliance with a good
manufacture technique of gates as well as for any deformation, which might
occur during use.
Keep this manual for further use.
Qualified personnel, in compliance with regulations in force, shall install the
system.
Packaging must be kept out of reach of children, as it can be hazardous. For
disposal, packaging must be divided the various types of waste (e.g. carton
board, polystyrene) in compliance with regulations in force.
The installer must supply all information on the automatic, manual and
emergency operation of the automatic system and supply the end user with
instructions for use. Make sure that before wiring an adequate differential
switch and an overcurrent protection is provided.
Pursuant to safety regulations in force, some types of installation require
that the gate connection be earthed.
During installation, maintenance and repair, cut off power supply before
accessing to live parts.
Descriptions and figures in this manual are not binding. While leaving the
essential characteristics of the product unchanged, the manufacturer reserves
the right to modify the same under the technical, design or commercial point
of view without necessarily update this manual.
Introduction
- Before installing the system, read the instruction herein. It is mandatory not to use the BOB item for applications different from those indicated in the instructions herein.
- Supply the end user with instructions for using this system.
- The end user should receive special instruction manual
- All Benincà items are covered by an insurance pol- icy for damages and injuries caused by manufacture faults. It is however required that the machine bear the CE marking and original Benincà parts be used.
General information
To ensure a good operation of these automatic devices, the gate to be
automated should meet the following requirements:
- good strength and stiffness.
- hinges should have a minimum backlash and al-low for smooth and regular manual operations.
- when closed, the gate leaves should correctly overlap for their entire height.
As the actuator is not supplied with electromagnetic limit switches, it is
indispensable to provide mechanical stops on closing and opening on the gate
that is to be automated (fig.1)
Fitting the automatic system
Stabilise the height of the automatic system above ground level (it should be
as central as possible with respect to the gate and corresponding to a sturdy
cross piece).
Then weld the plate P respecting the distances in fig. 2.
When the gate is closing, weld the bracket S respecting the distance in fig. 3,
onto a cross piece of the gate or another suitably robust element; bear in
mind that in this condition the actuator must not be completely at the end of
travel.
Remove the protective cover C unscrewing the screw F, then fix the actuator to
the plate P with the screw T, the washer L and the nut D (fig. 3).
Lastly block the actuator on the plate S with the screw V and the washer R.
The holes in the actuator (fig.2A) help you respect the optimum installation
distances.
The adjustable fixing brackets, available on request, allow a wider possibility
of adapting the actuator to the different installation conditions, also
avoiding cutting and welding the brackets supplied.
How to adjust the mechanical stoppers
The actuator is provided with adjustable mechanical stoppers in the opening
and closing phases. The sys-tem is adjusted by suitably positioning the “Open”
and “Close” mechanical locks, as shown hereunder (Fig.2): 1) Unlock the
automatic system by using the special release lever, as shown in the
instructions for the user.
- Close the door/gate leaf.
- Loosen screws V1 and move the “Close” lock until it reaches the pivot P, then tighten screws V1.
- Open the door/gate leaf.
- Loosen screws V2 and move the “Open” lock until it reaches the pivot P, then tighten screws V2.
- Reset the automatic operating mode.
Connections
The special plate P (Fig. 5) allows for using a link for sheath or cable gland
PG11, or PG13,5. Once the type of cable gland is applied to the plate, fix the
latter to the adaptor cover by means of screws V.
WARNING
The insurance policy, which covers any damages or injuries caused by
manufacture faults, requires that the installation comply with regulations in
force and Benincà original accessories be used.
TECHNICAL DATA
TECHNICAL DATA | BOB2124 BOB2124 E | BOB3024 BOB3024 E |
---|---|---|
Power supply | 24Vdc | |
Absorbed current | 5,5 A | |
Thrust | 1800 N | |
Jogging | Intensive | |
Protection degree | IP44 | |
Operating temperature | -20°C / +50°C |
Useful stroke:
- with 2 stoppers
- without stoppers
| 270 mm
325 mm
Noise level| <70 dB
Lubrication| Permanent grease
Weight| 8,2 kg| 8,3 kg
User’s handbook
Safety rules
- Do not stand in the movement area of the gate.
- Do not let children play with controls and near the gate.
- Should operating faults occur, do not attempt to repair the fault but call a qualified technician.
Manual and emergency maneuver In the event of a power cut or breakdown, proceed as follows to operate the wings manually (refer to figures A,B,C):
- Open the protective door of the release mechanism (fig. A).
- Insert the special release key supplied and turn it through 90°, as indicated in fig. B for a right actuator or as indicated in fig. C for a left actuator.
- It is now possible to open/close the wing manually.
- To restore automatic operation, return the release key to its initial position.
- Remove the release lever and close the protective door.
Maintenance
- Every month check the good operation of the emergency manual release.
- It is mandatory not to carry out extraordinary maintenance or repairs as accidents may be caused. These operations must be carried out by qualified personnel only.
- The operator is maintenance free but it is necessary to check periodically if the safety devices and the other components of the automation system work properly. Wear and tear of some components could cause dangers.
Waste disposal
As indicated by the symbol shown, it is forbidden to dispose this product as
normal urban waste as some parts might be harmful for environment and human
health, if they are disposed of incorrectly. Therefore, the device should be
disposed in special collection platforms or given back to the reseller if a
new and similar device is purchased. An incorrect disposal of the device will
result in fines applied to the user, as provided for by regulations in force.
Warning
All Benincá products are covered by insurance policy for any possible damages
to objects and persons caused by construction faults under condition that the
entire system be marked CE and only Benincá parts be used.
Part List
Ref.| BOB 2124
Code| BOB 2124 E
Code| BOB 3024
Code| BOB 3024E
Code| Note
---|---|---|---|---|---
1| 9686868| 9686868| 9686769| 9686769|
2| 9686869| 9686869| 9686869| 9686869|
3| 9686766| 9686766| 9686766| 9686766|
4| 9686871| 9686871| 9686871| 9686871|
5| 9686872| 9686872| 9686872| 9686872|
6| 9686873| 9686873| 9686816| 9686816|
7| 9686881| 9686767| 9686881| 9686767|
8| 9686765| 9686765| 9686765| 9686765|
9| 9686876| 9686876| 9686876| 9686876|
10| 9686877| 9686877| 9686877| 9686877|
11| 9686883| 9686883| 9686883| 9686883|
References
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>