dacor HDER36S Heritage 30 Wide Dual Fuel Ranges User Guide

June 17, 2024
dacor

dacor HDER36S Heritage 30 Wide Dual Fuel Ranges

Product Information

Specifications

  • Model: HDPR30S, HDER30S
  • Electrical Requirements: 240Vac*, 60 Hz, 30 Amp
  • Total Connected Load: 5.75kW (24.0 Amp)
  • Gas Type : Natural/LP (propane) Minimum Gas-Supply Pressure: 5 water column (Natural), 10 water column (LP)
  • Max Gas-Supply Pressure : 1/2 psi
  • GAS-/ELECTRICAL-ACCESS DIMENSIONS:
    • A: 3 1/4 (8.3 cm)
    • B*: 6 3/4 (17.1cm)
    • C: 4 1/4 (10.8 cm)
    • D*: 27 (68.6 cm)
    • E**: 6 3/4 (17.1cm)
  • Cabinet Layout:
    • Model HDPRS/HDERS 30:
    • Cutout Dimensions: F: 36(91.4cm) / G: 30 (76.2cm)
    • H: 27 3/8(69.5 cm)
    • Model HDPRS/HDERS 36:
    • Cutout Dimensions: F: 30 (76.2 cm) / G: 30 1/8(76.5cm)
    • H: 33 1/2(84.8 cm)
    • Model HDPRS/HDERS 48:
    • Cutout Dimensions: F: 42 (106.7 cm) / G: 36(91.4cm)
    • H: 43 1/2(110.5cm)

Product Usage Instructions

Electrical Installation

For the HDPR30S and HDER30S models, a 240Vac, 60 Hz, 30 Amp electrical circuit is required. The total connected load is 5.75kW (24.0 Amp). For the HDPR36S and HDER36S models, a 240Vac, 60 Hz, 30 Amp electrical circuit is required. The total connected load is 5.75kW (24.0 Amp). For the HDPR48S and HDER48S models, a 240Vac*, 60 Hz, 50 Amp electrical circuit is required. The total connected load is 10.1kW (41.9 Amp).

Gas Supply Installation

The minimum gas-supply pressure requirements are as follows:

  • Natural Gas: 5 water column
  • LP (propane): 10 water column

The maximum gas-supply pressure for all models is 1/2 psi.

Cabinet Layout and Cutout Dimensions

The cabinet layout and cutout dimensions for the HDPRS/HDERS models are as follows:

  • Model HDPRS/HDERS 30:
    • Cutout Dimensions: F: 36(91.4cm) / G: 30 (76.2cm)
    • H: 27 3/8(69.5 cm)
  • Model HDPRS/HDERS 36:
    • Cutout Dimensions: F: 30 (76.2 cm) / G: 30 1/8(76.5cm)
    • H: 33 1/2(84.8 cm)
  • Model HDPRS/HDERS 48:
    • Cutout Dimensions: F: 42 (106.7 cm) / G: 36(91.4cm)
    • H: 43 1/2(110.5cm)

Approved Downdraft Vents

For the HDPRS/HDERS models, the following downdraft vents are approved:

  • HDPRS/HDERS 30: MRV3015
  • HDPRS/HDERS 36 : MRV36-ER
  • HDPRS/HDERS 48 : MRV48-ER

Important: Please refer to the downdraft installation instructions for duct and electrical installation requirements. Use only approved Dacor downdraft vents.

Countertop Cutout For Downdraft Vent

  1. Vertical from range grate level to combustible overhead surface; if installing an overhead hood, see hood specifications for minimum required clearances.
  2. Cabinet/countertop depth is at the customer’s discretion, but the cabinet face must not protrude beyond the rear of the range front panel.

FAQ

  • Q: Can the electrical wiring hole size be increased?
  • A: Yes, the hole size for the electrical wiring may be increased to 11/8(2.9 cm) by removing the conduit bracket at the bottom of the electrical box.
  • Q: Where can I find the exact specifications for the gas-supply pressure?
  • A: The exact specifications for the gas-supply pressure can be found on the rating label located on the upper-rear of the range.
  • Q : Are there any specific installation requirements for freestanding ranges installed in Canada?
  • A: Yes, for freestanding ranges installed in Canada, a factory-installed 4-wire appliance cord with NEMA 14-50P plug is required, without modification.

Dimensions

  • Observe all governing codes and ordinances during planning and installation. Contact your local building department for details.t
    The range must be installed as specified in its installation instructions.

Critical Depth/Height Dimensions

HDPRS model shown; common dimensions are given; unique HDPRS/HDERS dimensions indicated

ELECTRICAL REQUIREMENTS

Model| Required Circuit| Total Connected Load
HDPR30S, HDER30S| ****

240 Vac*, 60 Hz, 30 Amp.

| ****

5.75 kW (24.0 Amp.)

HDPR36S, HDER36S
HDPR48S, HDER48S| 240 Vac, 60 Hz, 50 Amp.| 10.1kW (41.9Amp.)
4-wire, two 120 Vac hot (L1 and L2), one neutral, one ground; these ratings are for reference only; see the range’s data label (back of range) for exact specifications.

The wiring must be long enough that the range can be pulled out for service, without being disconnected. Wiring to the range must:

  • meet NEMA standards and the requirements in the abovetable
  • include a strain relief
  • be terminated by tinned leads, closed-loop terminals, or open-ended spade lugs with upturned ends
  • connect to a junction box or receptacle installed by a licensed electrician.

The range may be connected via one of these two methods:

  • 4-wire conduit connected to a 4-wire junction box
  • 3-wire conduit (where local code permits, not for use with new branch circuit installations) connected to a 3-wire junction box.

Using a power cord:

  • A 4-wire power cord with a NEMA14-50P plug connected to a NEMA 14-50R receptacle:

  • A 3-wire power cord (where permitted) with a NEMA10-50P plug connected to a NEMA 10-50R receptacle

  • The power cord plug must be UL-listed type SRD or SRDT.

  • Range models DYRP36D-C-S and DYRP48D-C-S come with a factory-installed 4-wire appliance cord with a NEMA14-50P plug. For freestanding ranges installed in Canada, a factory-installed 4-wire appliance cord with NEMA 14-50P plug is required, without modification.

MINIMUM GAS-SUPPLY PRESSURE REQUIREMENTS

MINIMUM GAS-SUPPLY PRESSURE **REQUIREMENTS***

Gas Type| Min. Manifold Pressure| Min. Gas- Supply Pressure**
Natural| 5” water column| 6” water column
LP (propane)| 10” water column| 11” water column
*Gas-supply pressure for testing the regulator setting shall be at least 1” water column (249 Pa) above the specified manifold pressure; **Max gas-supply pressure, all models: 1/2psi.

The above ratings are for reference only; see the rating label (upper-rear range) for exact specifications.

GAS-/ELECTRICAL-ACCESS **DIMENSIONS**

Model| A| B| C| D| E**
HDPR30S/ HDER30S| 3 1/4″ (8.3 cm)| 27”

(68.6 cm)

| 6 3/4″ (17.1cm)|

6 3/4 (17.1cm)

|

7/8”

(2.2 cm)

dia.

HDPR36S/ HDER36S| 6 3/4″ (17.1cm)| 27”

(68.6 cm)

| 12”

(30.5 cm)

HDPR48S/ HDER48S| 4 1/4” (10.8 cm)| 27”

(68.6 cm)

| 9”

(22.9 cm)

*Measurement with range legs adjusted to their lowest height; **The hole size for the electrical wiring may be increased to 11/8”(2.9 cm) by removing the conduit bracket in the bottom of the electrical box.

Cabinet Layout

  • All maximum/minimum dimensions and clearances in the diagrams below must be maintained for safe operation.
  • Place the range away from drafts (open doors and windows, and home heating/cooling systems).
  • Do not install cabinets over the range, or to reduce the risk of burn injury from reaching over a hot cooktop, install a range hood that projects horizontally at least 5” beyond the cabinet bottoms.
  • The range may be installed against the rear wall. Dacor strongly recommends installing a backguard or non-combustible material on the rear wall between the range vent hood.
  • Seal openings in the wall behind the range and in the floor below.
  • The grey area in the diagram below shows the suggested gas/electrical utilities. Existing utilities may be used if they do not hinder range placement.
  • Gas/electrical utilities must be located so the range can be moved for service without being disconnected.
  • An external, manual shut-off valve must be installed between the gas inlet and range so gas to the range can be shut on/off.
  • Installation must allow access to the gas shut-off valve and circuit-breaker panel/fuse box when the range is in place.

CUTOUT DIMENSIONS

Model| F: recommended/min.| G: min./max.| H
HDPRS/HDERS 30| 36”(91.4 cm) / 30” (76.2cm)| 30” (76.2 cm) / 30 1/8”(76.5cm)| 273/8″(69.5 cm)
HDPRS/HDERS 36| 42” (106.7 cm) / 36”(91.4cm)| 36”(91.4 cm) / 36 1/8”(91.8cm)| 33 1/2”(84.8 cm)
HDPRS/HDERS 48| 54”(137.2cm) / 48” (122.0cm)| 48” (121.9cm) / 48 1/8”(122.2 cm)| 43 1/2”(110.5cm)
APPROVED DOWNDRAFTVENTS

Range| Downdraft Vent
HDPRS/HDERS 30| MRV3015
HDPRS/HDERS 36| MRV36-ER
HDPRS/HDERS 48| MRV48-ER
IMPORTANT: See downdraft installation instructions for duct and electrical installation requirements. Use only approved Dacordowndraft vents.

Standard Cutoutwith Range Hood

Countertop Cutout For Downdraft Vent

  1. Vertical from range grate level to the combustible overhead surface; if installing an overhead hood, see hood specifications for minimum required clearances.
  2. Cabinet/countertop depth is at the customer’s discretion, but the cabinet face must not protrude beyond the rear of the range front panel. (See Pg.1fordimensions.)
  3. Consult local codes for exact location requirements.
  4. Vertical from grate level to a combustible surface.
  5. Not applicable to cabinets that horizontally are over 10” (25.4 cm) from the range edge.