DELL MD1000 SAS Solution User Guide
- June 17, 2024
- Dell
Table of Contents
- DELL MD1000 SAS Solution
- Product Information
- Product Usage Instructions
- Introduction
- PowerVault MD1000 Storage Enclosure Details
- PERC 5/E Controller – Detailed Features
- Dell OpenManage Server Administrator
- Storage Applications and Components
- Summary and Conclusions
- References
- Read User Manual Online (PDF format)
- Download This Manual (PDF format)
DELL MD1000 SAS Solution
Product Information
Specifications
- Model: [Model Name]
- Dimensions: [Dimensions]
- Weight: [Weight]
- Power Source: [Power Source]
- Color: [Color]
Product Usage Instructions
Section 1: Setup
- Unbox the product and remove all packaging materials.
- Place the product on a stable surface.
- Connect the power source to the product.
- Turn on the product using the power button.
- Follow the on-screen instructions to complete the initial setup process.
Section 2: Basic Operations
- To turn on the product, press the power button located on the front panel.
- Use the control buttons or remote control to navigate through the menu options.
- Adjust the settings such as brightness, volume, and contrast according to your preference.
- To switch between different modes or inputs, use the input selection button.
- To turn off the product, press and hold the power button for a few seconds.
Section 3: Maintenance and Cleaning
- Before cleaning the product, make sure to disconnect it from the power source.
- Use a soft cloth dampened with water or a mild cleaning solution to wipe the surface of the product.
- Avoid using abrasive cleaners or solvents that may damage the product.
- Gently clean the screen with a microfiber cloth to remove any smudges or fingerprints.
- Regularly check and clean the ventilation ports to prevent dust buildup.
Frequently Asked Questions (FAQ)
Q: How do I change the language settings?
A: To change the language settings, go to the settings menu and look for
the language option. Select your desired language from the available options.
Q: Can I connect external devices to this product?
A: Yes, you can connect external devices such as a DVD player or gaming
console to this product. Use the appropriate input ports and select the
corresponding input mode.
Q: How do I adjust the picture quality?
A: To adjust the picture quality, go to the settings menu and look for
the display or picture options. From there, you can modify settings such as
brightness, contrast, and color saturation.
Q: What should I do if the product is not turning on?
A: First, make sure that the power source is properly connected and
turned on. If the problem persists, check if the power button is functioning
correctly. If necessary, contact customer support for further assistance.
Q: How often should I clean the product?
A: It is recommended to clean the product regularly to maintain optimal
performance. Depending on usage and environment, cleaning once every few weeks
or months should be sufficient.
THIS WHITE PAPER IS FOR INFORMATION PURPOSES ONLY, AND MAY CONTAIN TYPOGRAPHICAL ERRORS AND TECHNICAL INACCURACIES. THE CONTENT IS PROVIDED AS IS WITHOUT EXPRESS OR IMPLIED WARRANTIES OF ANY KIND.
Information in this document is subject to change without notice.
© Copyright 2006 Dell Inc. All rights reserved.
Reproduction in any manner whatsoever without the written permission of Dell
Inc. is strictly forbidden.
Dell, the Dell Logo, PowerVault, PowerEdge and OpenManage are trademarks of
Dell Inc. Microsoft is a registered trademark of Microsoft Corporation. Other
trademarks and trade names may be used in this document to refer to either the
entities claiming the marks and names or their products. Dell disclaims
proprietary interest in the marks and names of others.
Introduction
A complete enterprise storage solution involves various software and hardware
components. A given storage project can be addressed using several approaches.
Therefore, it is essential to identify optimum storage solutions for different
applications.
Selecting the right storage components not only impacts the effectiveness of a
given application but may also improve the performance of the entire IT
infrastructure which relies on that storage. See table 1 for examples of key
storage components.
Table 1: Examples of the components in a typical storage solution
Storage Solution Components | Examples |
---|---|
Physical Storage Device Technology | Storage Expansion Enclosure (e.g., |
PowerVault MD1000)
Interconnect Technology| 3 Gbps Serial Attached SCSI (SAS)
Host System Interface Technology| Non-RAID (HBA) or RAID controllers (e.g.
PowerEdge Expandable Raid Controller)
Management Capabilities| Dell OpenManage Server Administrator
As with many IT solutions, storage deployments can be assessed using numerous criteria, each with varying levels of importance. In general, the effectiveness of a given storage solution should be measured using the following attributes:
- Reliability – The solution remains functional and ensures that data is unaltered
- Availability – Data remains accessible by the application.
- Serviceability – The hardware has easy access to assemblies/components, allowing easy maintenance and replacement.
- Redundancy – The hardware provides redundancy for both the data storage, as well as for the hardware management capabilities.
- Performance
- Bandwidth Utilization – Data throughput / available Bandwidth
- IOPS – I/Os per second
- Data Protection – Data is protected against catastrophic system failure or components failure.
- Scalability – Storage capacity can be expanded as the application necessitates.
- Cost – Measured in total lifetime cost, acquisition cost, or $ per Gigabyte.
An optimal storage solution addresses all key attributes to a greater or lesser extent depending on their relative importance. This paper presents a study of the technological, functional and behavioral differences of the storage solution components and measures them against the attributes listed above. Understanding each component with respect to these attributes will help in making informed decisions about the optimal solution for a given storage application.
The paper presumes that the reader has a basic understanding of different RAID levels and interconnect technologies – such as Serial Attached SCSI (SAS) and PCI Express. In this paper, we will focus on Serial Attached SCSI storage technology, specifically for Dell’s PowerVault MD1000 storage expansion enclosure and Dell’s PERC 5/E RAID controller. Other storage technologies such as SCSI or Fibre Channel, as well as topologies such as Network Attached Storage (NAS) or Storage Area Network (SAN) are outside the scope of this document. All storage applications will be treated independent of any specific host system or server.
Serial Attached SCSI (SAS)
The SCSI (Small Computing System Interface) protocol originated more than 20
years ago and is used in the majority of server storage needs (e.g. storage
that is internal to a server or physically connected to a server in an
external disk expansion enclosure). The market prevalence of SCSI has created
economies of scale making it one of the most affordable storage interconnect
technologies available today. Many businesses rely on SCSI physical disks to
help deliver extremely cost-effective and reliable storage. In fact, SCSI
physical disks have advanced over the years offering increased performance and
more sophisticated features with each iteration. However, given the inherent
limitations of its parallel architecture, the current version of SCSI physical
disks, U320 or Ultra320, will be the last version of the traditional SCSI
technology.
Serial Attached SCSI (SAS) is a major iteration of SCSI technology and
introduces a host of benefits when compared to older SCSI technology
including,
Dramatic improvement in bandwidth performance
-
The first generation of SAS will support 3.0 Gbps (or 300 MB/sec) per “lane”
-
Ultra320 SCSI is the shared-bus architecture. SAS introduces a point to point topology enabling systems with many physical disks to scale bandwidth far beyond the bandwidth capacity of Ultra320 SCSI.
Figure 1: Parallel U320 SCSI bus versus point to point Serial Attached SCSI connection -
SAS introduces the concept of port aggregation to storage interconnects. External storage devices can connect via a x4 (“by four”)wide-lane. Cabling aggregates four SAS lanes, each operating at 3.0 Gbps, for a full external connection bandwidth of up to 12.0 Gbps on a single connector.
Figure 2: Bandwidth improvement with SAS port aggregation
Improved capacity scalability
- SAS allows for port expansion, enabling the ability to “daisy-chain” storage enclosures for dramatic improvements in capacity scalability. With Ultra320 SCSI, systems were limited to a maximum of 16 devices on a single SCSI channel. This typically translated to maximum of 14 physical disks connected to a single SCSI channel on a RAID controller. With SAS expansion, a single SAS port can be expanded out to multiple SAS devices (similar to how Ethernet hubs can expand a single Ethernet connection into multiple devices).
Other important changes to keep in mind about SAS:
- SAS continues to use the SCSI command sets for driver & software compatibility.
- SAS is not backwards compatible with Parallel SCSI.
Recommended Maintenance for your Dell PowerVault MD1000 SAS Solution
Dell strives to provide the best possible customer experience for all of our enterprise server and storage products. Proper maintenance of your solution is essential to help ensure that the equipment remains in optimal working condition. Dell recommends the following suggested maintenance activities.
Keep firmware/drivers/utilities up to date
In general, Dell posts planned maintenance updates for firmware twice a year.
To stay current with the latest updates, customers can subscribe to Dell
notification tools. Click the following link to sign up for technical updates.
http://support.dell.com/support/topics/global.aspx/support/notifications/en/index?c=us&l=en&s=gen
Enable Background Read Patrol
Background Read Patrol, a function of the RAID controller, is an automatically
scheduled background task that scans and helps resolve possible physical disk
errors that may lead to physical disk failure and result in data integrity
issues. Dell recommends implementing Background Read Patrol in all
configurations.
See section 5 for details.
Schedule and run periodic consistency checks / Background Initialization (BGI)
Consistency checks / BGI are performed by many RAID controllers to verify that
all stripes in a redundant virtual disk are consistent and to automatically
correct stripes where inconsistencies are found. BGI is a consistency check
that automatically runs on all redundant arrays. Depending on workload, Dell
recommends that consistency checks should be run manually on the virtual disks
at least once every month to help ensure data integrity. Consistency checks
and Background Read Patrol are complementary and both should be used.
See section 5 for details.
Enable Hot Spares
Hot spare functionality provides extra security, availability and redundancy
by automatically replacing a failed disk in a RAID group and allowing the
rebuild of the degraded array to begin immediately. Dell PERC controllers
support Hot Spare functionality and it is recommended whenever possible.
See section 5 for details.
Document your configuration and keep the documentation current
Documenting your configuration facilitates faster and easier recovery should a
failure occur. Make sure to include RAID levels, physical disks included in
your virtual disks, firmware and driver versions and usage of hot spares in
your documentation.
Perform periodic physical inspection of your connections and cabling
Damaged cables and loose connections may cause functional issues with your
storage solution. Dell recommends a physical equipment audit two times a year
or anytime after re-cabling or re-deploying your storage hardware.
Dell’s SAS Product Offering
The PowerVault MD1000 is a feature-optimized storage expansion enclosure which utilizes the latest industry standard storage interconnect technology, Serial Attached SCSI (SAS). This 3U enclosure supports between 2 and 15 physical SAS drives. Along with Dell’s host-based RAID controller, PERC 5/E, the PowerVault MD1000 storage enclosure introduces new levels of performance, capacity, and scalability. Major features of the PowerVault MD1000 and PERC 5/E solution include:
Performance
- Support for 3.0 Gbps SAS physical disks (both 10,000 and 15,000 RPM)
- External cable supports a SAS x4 wide-lane to achieve a total interface bandwidth of up to 12.0 Gbps connection to the host controller
- Host interconnect with the PERC 5/E host-based controller
- Support for RAID level 0
Availability
- Support for RAID levels 1, 5, 10 and 50
- Redundant, hot pluggable power supplies with integrated cooling fan modules
- Redundant enclosure management modules (EMMs)
- Hot pluggable physical disks
Scalability/Expandability
- Support for daisy-chaining up to three PowerVault MD1000 expansion enclosures per PERC 5/E connection
- Supports between 2 and 15 physical SAS drives
- Supports 36GB, 73GB, 146GB, and 300 GB 3.5-inch SAS physical disks
Ease-of-Use
- Common management software with PowerEdge™ servers through Dell OpenManage Server Administrator
PERC 5/E is the RAID controller used to connect the PowerVault MD1000 storage enclosure to one or two PowerEdge servers. It supports 3 Gbps Serial Attached SCSI (SAS) as the storage interconnect technology and PCI Express (PCI-E) as the host-based interconnect technology. The “E” in PERC 5/E stands for “External” because the PERC 5/E controller supports only physical disks that attach to a server externally.
The PERC 5/E controller offers:
- Intel IOP333 I/O processor based on Intel XScale Microarchitecture
- 256MB of customized DDR2 400MHz, Error-Correcting Code (ECC) cache memory
- 3 Gbps maximum speed for each SAS lane
- Two external x4 (“by four”) SAS ports, each aggregating 4 SAS lanes for a total bandwidth per port of 12.0 Gbps
- x8 PCI E host interface for a total bandwidth of 32.0 Gbps
- Up to 72 hours of intelligent, transportable, battery-backed, cache memory
For detailed information on the PERC 5/E controller, see section 6.
SAS Cabling
The PowerVault MD1000 storage enclosure and the PERC 5/E controller both
support industry standard 3.0 Gbps SAS cables in 1m, 2m, and 4m cable lengths.
Each cable supports x4 SAS connectors to deliver up to 12.0 Gbps of total
bandwidth from the host to the enclosure. Only Dellqualified cables are
supported for connecting the PowerVault MD1000 storage enclosure to the PERC
5/E controller.
Physical Drive Support
The PowerVault MD1000 storage expansion enclosure supports the latest SAS
physical disks,currently specified as 3.0 Gbps SAS. SAS solutions from Dell
include both 10,000 RPM and 15,000 RPM spindle speeds and a variety of
capacities to allow customers the maximum flexibility.
For the latest information on support for specific physical disks, see the Dell Storage web site at: http://www.us.dell.com/storage/
3rd Party Hardware support
To help provide the best possible customer experience, Dell supports only
hardware purchased direct from Dell for the PowerVault MD1000 and PERC 5/E
controller. Dell-developed server and storage solutions include many thousands
of person-hours of engineering testing and validation to help ensure the
highest product quality. For example, physical disks purchased direct from
Dell may include features not generally available to the rest of the industry.
As such, Dell supports only Dell tested and qualified hardware. Hardware
purchased direct from Dell carries the full Dell system limited warranty1 and
helps ensure full compatibility. Materials purchased from 3rd party vendors
for use in Dell systems are not covered under Dell’s limited warranty and may
not deliver an acceptable customer experience.
Server Support
The PowerVault MD1000 storage enclosure and PERC 5/E solution are supported on
the PowerEdge 1850, 2850, 6800, and 6850 servers.
PowerVault MD1000 Storage Enclosure Details
Enclosure Modes
The enclosure can be set to either unified or split mode through the use of a
two-position switch located on the front panel of the enclosure. The enclosure
can be configured into the selected mode only at power up. Any changes to the
mode switch made while the enclosure is powered on will not take effect until
the enclosure is powered off and back on again.
Note: Any time you power on the PowerVault MD1000 storage enclosure, ensure
the mode switch is set in the desired position. If the position of the switch
changes inadvertently, data loss could occur as the controller may recognize
an inaccurate number of attached physical disks versus the previous mode. In
order to cycle power on your MD1000, all attached servers, must be turned off.
Unified Topology
In unified mode, a single server has access to all fifteen physical disks in
the PowerVault MD1000 storage enclosure through a single SAS cable. The
unified mode can also provide a single server access to a maximum of forty
five physical disks by daisy-chaining up to three enclosures from a single
host port. The main advantage of unified mode is that it provides a high
degree of physical disk scalability.
Split Topology
In split mode, the enclosure is divided into two logical enclosures; with each
host connection accessing its own set of physical disks. The primary Enclosure
Management Module (EMM) (located on the left side of the enclosure when viewed
from the rear), accesses physical disk slots 7 through 14. The secondary EMM
accesses physical disk slots 0 through 6. To connect a server to an enclosure
in split mode, the In port of each EMM should be attached to a connector of a
PERC 5/E controller. The Out port of an EMM in split mode is disabled, since
enclosure daisychaining is not supported in this mode.
Split mode is useful in deployments where a single PowerVault MD1000 storage
enclosure help provide limited amounts of storage each for two different
servers.
Note:
- In split mode, each host server can see its own physical disks (e.g. drive., physical disk 0 – 6 or 7 – 14) but not the other server’s physical disks.
- Split mode does not support daisy-chaining.
- A system with a single EMM set in split mode will function properly, but the server will only be able to see the physical disks that are connected to the EMM.
Dual Hosts
Figure 3: Split mode configuration
Daisy-Chaining Multiple PowerVault MD1000 Storage Enclosures
In unified mode, up to three enclosures may be daisy-chained together from a
single PERC 5/E controller port. A maximum of six PowerVault MD1000 storage
enclosures (3 enclosures per port) may be connected to a single PERC 5/E
controller. (Note: Although this is a supported configuration, one should
consider total solution availability before attaching this quantity of storage
to a single-controller solution.). When connecting multiple enclosures, the
first enclosure is connected to the PERC 5/E controller via the In port of the
primary EMM. The second enclosure is connected from the Out port of the
primary EMM on the first enclosure to the In port of the primary EMM on the
second enclosure. The connection is made with a standard SAS cable. The third
enclosure is connected in the same manner as the second enclosure.
Figure 4: Max configuration on a single PERC 5/E controller port
Figure 5: Max configuration on a single PERC 5/E controller (both ports connected)
PowerVault MD1000 – Common Features and Capabilities
Regardless of the topology, the PowerVault MD1000 storage enclosure provides a
set of common features and capabilities.
World Wide Name (WWN) Assignment
The SAS standard requires that all devices on a SAS domain have a unique
address, called a World Wide Name or WWN. The PowerVault MD1000 storage
enclosure complies with the SAS standard. For more information on WWN
assignment, please refer to the SAS Specification referenced in Appendix A.
Mixing Physical Disk Capacities
By supporting the mixing of physical disk of different sizes within an
enclosure, the PowerVault MD1000 storage enclosure enables optimal matching of
physical disk type to the requirements of multiple applications. Mixing of
physical disk sizes is supported but not recommended within a single RAID
group. The PowerVault MD1000 storage enclosure supports 36 GB, 73 GB, 146
GB,and 300 GB capacities for SAS. When operating in a RAID configuration, the
lowest capacity physical disk defines the RAID virtual disk size. For example,
a RAID 1 configuration with two different sized physical disks, one 36 GB and
another 146 GB physical disk, will be limited to 36 GB. If the same two
physical disks were configured in RAID 0 configuration, the virtual disk size
would be limited to 73 GB (the equivalent of two 36 GB physical disks in RAID
0 configuration).
Mixing Physical Disk Spindle Speeds
Mixing different physical disk spindle speeds is supported, but not
recommended within a single RAID group. The PowerVault MD1000 storage
enclosure supports 10,000 and 15,000 RPM spindle speeds. Depending upon the
RAID configuration, the lowest spindle speed may dictate the maximum
performance of the RAID group.
SCSI Enclosure Services (SES)
The EMM continuously monitors environmental variables such as temperature and
voltage. The PowerVault MD1000 storage enclosure works in conjunction with
Dell OpenManage Server Administrator to set trigger thresholds that warn the
user when these variables exceed safe operating levels. The enclosure will
automatically power down when these environmental variables exceed a critical
threshold level in order to avoid potential equipment damage. Both local
visual indicators (e.g. LEDs) and audio alerts are triggered when faults are
detected. The audio alerts on the enclosure are disabled by default, but can
be enabled using Server Administrator. The following SES functions are
provided by the EMMs in the PowerVault MD1000 storage enclosure:
- Enclosure shelf faults detection
- Physical disk Power/Fault/Offline status
- Power supply status and shutdown capabilities
- Fan speed status and control
- Temperature monitoring
- Over/under temperature shutdown capabilities
- Alarms (local audible and visual LED indicators)
Hot Plugging
- The PowerVault MD1000 storage enclosure is designed for hot plugging certain components to help prevent damage when pulling or replacing. Hot plugging is a concept which allows for the safe removal and replacement of components while the power is still on. Hot plugging allows server applications and disk activities to continue uninterrupted, while maintenance or repair actions take place. Additional steps may be required for physical disks to become usable. See the RAID controller User’s Guide for more information.
- Hot Pluggable Devices
- Physical disk (all Disk I/O activities must be halted first)
- Power supply module/ cooling fan module
Note: Hot plugging of SAS cables is not supported.
External SAS Cables
Depending on the enclosure topology, one or two external SAS cables may be
attached between the host system(s) and the PowerVault MD1000 storage
enclosure. SAS cables use four active 3 Gbps SAS lanes in a single cable to
deliver an aggregate of 12.0 Gbps connection. All PowerVault MD1000 SAS cables
purchased from Dell have been tested and comply with the ANSI SAS 1.0
standard. Dell supports using only Dell-provided cables.
External SAS Connector Types
SAS uses a 25-pin connector whose specification is governed by the SFF-8470
specification. For more information, refer to the specification referenced in
Appendix A.
Regardless of the topology, the PowerVault MD1000 storage enclosure also
provides some common capabilities as listed below:
Redundancy Capabilities
-
Management Redundancy
With two EMMs installed, the PowerVault MD1000 storage enclosure’s internal enclosure functions on the PowerVault MD1000, such as temperature regulation, LED control, and alarm control, are maintained in the event of an EMM failure. However, even with dual EMMs installed, enclosure status will not be reported to the host in the event of an EMM failure. -
Power Supply and Cooling Redundancy
The PowerVault MD1000 storage enclosure requires that both power supplies be installed for normal operation. The system can operate using a single power supply for a limited time in the event a power supply fails or is removed for service.
The PowerVault MD1000 storage enclosure provides four individually controlled fans, two installed in each power supply. The unit is thermally designed to continue operating in the event of one fan blower failure (3+1 cooling redundancy). In the event of a fan failure, the power supply containing the failed fan must be replaced.
Reliability Capabilities
-
Thermal Reliability
A fully-redundant PowerVault MD1000 storage enclosure contains four digital temperature sensors, two on the backplane and one on each EMM. In conjunction with the SES processor, the temperature sensors provide device protection against adverse thermal conditions. The PowerVault MD1000 storage enclosure is designed to operate within an ambient temperature range of 10°C (50°F) to 35°C (95°F). When either of the backplane sensors detects temperature below 3°C (37.4°F) or above 55°C (131°F), the SES processor notifies the host of a critical temperature situation. This triggers the host to perform a graceful shutdown of the enclosure within three minutes. In the event that the host is unable to initiate the enclosure shutdown process or a host is not connected to the enclosure, the PowerVault MD1000 storage enclosure has an embedded thermal shutdown feature. This is activated by the SES processor in either of the following cases:- Either of the backplane temperature sensors detects temperature below -2°C (28.4°F) or above 60°C (140°F).
- Temperature sensor on an EMM detects temperatures below -2°C (28.4°F) or above 65°C (149°F).
The PowerVault MD1000 storage enclosure shuts down within 5 seconds of the activation of an embedded thermal shutdown.
PowerVault MD1000 Serviceability Capabilities
- All the major PowerVault MD1000 components are easily accessible and replaceable even when in a rack.
- The PowerVault MD1000 storage enclosure is equipped with LED indicators for visual status reporting on the status of internal components.
- The PowerVault MD1000 storage enclosure’s audible alarm notifies users of critical/noncritical status (for details, see PowerVault MD1000 Hardware Owners Manual). Status is also reported to the host system’s management tool, Server Administrator (for details, see the OpenManage User’s Guide.)
PERC 5/E Controller – Detailed Features
PERC 5/E is the RAID controller used to connect the PowerVault MD1000 storage enclosure with PowerEdge servers. It supports 3 Gbps Serial Attached SCSI (SAS) as the storage interconnect technology and PCI -E as the host-based interconnect technology. PERC 5/E controller supports RAID levels 0, 1, 5, 10 and 50.
Considerations when implementing a RAID Solution
The selection of a RAID solution in any environment is governed by several
aspects including controller and capacity requirements. Each of these factors
is discussed in detail in the following sections.
Controller Features
The Server Administrator is the recommended application for configuring and
managing the PowerVault MD1000 storage enclosure. Apart from the Server
Administrator software, the BIOS configuration utility (
-
Virtual Disk Initialization
PERC 5/E controller is capable of performing initialization on the virtual disk(s) by either writing 0’s to a portion of the physical disk (fast initialization) or to the entire physical disk (full initialization). Full initialization guarantees that any legacy data is cleared and all sectors are healthy. -
Background Patrol Read
Background Patrol Read is an automatically scheduled background task that scans and resolves possible physical disk errors that may lead to physical disk failure and result in data integrity issues. Dell recommends implementing Background Patrol Read in all the configurations. -
Consistency Check/Background Initialization (BGI)
Consistency checks / BGI are performed by PERC 5/E controller to verify that all stripes in a redundant virtual disk are consistent and to automatically correct stripes where inconsistencies are found. BGI is a consistency check that automatically runs on all redundant arrays. Depending on workload, Dell recommends that consistency checks are run manually on virtual disks at least once every month to ensure data integrity. Running a consistency check is complement to running Patrol Read and both should be used. -
RAID Level Migration
Changing the RAID level of a virtual disk from the existing level (e.g. RAID
-
to another level (e.g. RAID 5) is called RAID level migration. Dell recommends that data in the virtual disk be backed up before a RAID level migration is initiated. Dell also strongly recommends that the size of the physical disks to which the RAID level is to be migrated is greater than or equal to the size of the physical disks in the existing virtual disk. Dell supports RAID level migration as follows:
- RAID 1 to RAID 0
- RAID 0 to RAID 1
- RAID 5 to RAID 0
- RAID 0 to RAID 5
- RAID 1 to RAID 5
-
Capacity Expansion
Expanding the capacity of a virtual disk by adding another physical disk is called capacity expansion. Dell supports capacity expansion on all the supported RAID levels except RAID 1. Dell recommends that the data in the virtual disk be backed up before capacity expansion is initiated. For more details on capacity expansion, see the Dell PERC 5/E User’s Guide. -
Controller Write Cache Policy Options
Write–Back Caching
In write-back caching, data transfer is completed when the controller cache receives all data from host for the write transaction. Write-back caching is faster than write through caching. The main advantage of write-back caching is improved performance since the controller does not have to wait for an acknowledgement from the physical disk before proceeding. The battery backup unit for the controller is required to enable write-back caching. For more details on write-back caching, see the Dell PERC 5/E User’s Guide.
Write-Through Caching
In write-through caching, a data transfer is completed when the disk subsystem receives all of the data from the host. Write-through caching provides additional security because data must be committed to the physical disk before proceeding. There may be a minimal performance impact since the controller must wait for the physical disk to return a good status to the controller before proceeding to the next operation. -
Hot Spare Support
When a physical disk is assigned to a virtual disk as a hot spare, the PERC 5/E controller will automatically rebuild the virtual disk using the hot spare in the event of a failed physical disk. This restores the virtual disk to optimal redundancy. The hot spare disk must be equal to or greater than the largest physical disk size within any of the virtual disks. Dell recommends assigning hot spares to redundant virtual disks only, (i.e. RAID 1, RAID 5, RAID 10 and RAID 50.)
Global Hot Spare
A global hot spare is a backup physical disk capable of replacing a failed physical disk in any virtual disk on PERC 5/E controller. The capacity of a global hot spare should be greater than or equal to the largest physical disk in all the disk groups.
Dedicated Hot Spare
A dedicated hot spare is a backup physical disk capable of replacing a failed
physical disk in a specific PERC 5/E virtual disk. The capacity of a dedicated
hot spare should be greater than or equal to the largest physical disk in the
virtual disk to which it is assigned.
Dell recommends assigning dedicated hot spares to all business critical
virtual disks.
-
Disk Roaming
Disk roaming is initiated when the physical disks are changed to different ports on the same controller. The physical disk roaming feature will detect the RAID configuration from the configuration metadata residing on the physical disk. -
Rebuild
The process of restoring the redundancy of a RAID 1, 5, 10 or 50 virtual disk is called rebuilding. The rebuilding process can be initiated manually or automatically. Dell recommends choosing the automatic rebuild option to prevent running in the degraded mode for an extended period of time. -
Mixed-Size Physical Disk Within RAID 10 or RAID 50
When mixing physical disk sizes in RAID 10 or RAID 50, the controller will not coerce the larger virtual disks to match the size of the smallest virtual disk. PERC 5/E controller will stripe across all disks until the smallest one is full, then it will continue to stripe across the remaining disks until the next one is full, and so on until all the available space is used.
This process can impact performance as the array fills up, since the numbers of stripes decreases as disks fill up.
Capacity Requirements
The PERC 5/E controller supports up to sixty four virtual disks simultaneously
of which each virtual disk can contain up to thirty two physical disks. The
maximum number of total virtual disks that can be supported on each physical
disk is sixteen. PERC 5 controllers support virtual disks greater than 2 TB in
size, but Dell recommends checking the capacity of the operating systems to
support boot volumes of that capacity.
http://www.microsoft.com/windowsserversystem/storage/getstorfacts.mspx
http://www.dell.com/downloads/global/vectors/2004_2tblun.pdf
Table 2: PERC 5/E controller features
Feature | Comment |
---|---|
SAS Technology | 3Gbps |
Host Bus Interface | x8 PCI Express |
Internal connectors | N/A |
External Connectors | 2 |
RAID Levels Supported | 0, 1, 5, 10, 50 |
Cache Size (DIMM) | 256MB DDR2 |
Write Cache Options | Write-Through, Write-Back |
Read Cache Options | Read-Ahead, No Read Ahead |
BBU Battery Life | Up to 72 hours |
Maximum Number of Virtual Disks/Controller | 64 |
Maximum Number of
Physical Drives/Virtual Disk
| 32
Form Factor| Full Height, Half-Length PCI Adapter card
I/O Processor (IOP)| Intel IOP333
Dell OpenManage Server Administrator
Dell OpenManage Server Administrator is a management application for
configuring PowerEdge servers. The Server Administrator’s configuration
abilities for host-based RAID and non-RAID disk storage are of particular
interest for this paper. The Server Administrator enables you to perform
controller and enclosure functions from a single, graphical or command line
interface. The graphical user interface (GUI) is wizard-driven with features
for novice and advanced users and detailed online help. The command line
interface is fully-featured and scriptable.
The Server Administrator provides SAS support with the PERC 5/E controller and
the PowerVault MD1000 storage enclosure. Server Administrator also supports
the SCSI and ATA technologies.
Managing the PERC 5/E Controller and the PowerVault MD1000 Storage
Enclosure
After installing Server Administrator, the user can expand the storage object
in the tree view to display the storage components attached to the system.
These components include supported controllers and enclosures, virtual disks,
physical disks, and the connectors (SAS ports and/or SCSI channels) that
comprise the topography of all attached storage.
The PERC 5/E controller and the PowerVault MD1000 storage enclosure are
represented in Server Administrator’s tree view. You can select the PERC 5/E
object and the PowerVault MD1000 object to display the status and to provide
access to PERC 5/E controller and PowerVault storage enclosure tasks.
Using the Create Virtual Disk Wizards
You can create virtual disks using either Server Administrator’s Create
Virtual Disk Express or the Create Virtual Disk Advanced wizard. These wizards
enable you to quickly configure virtual disk attributes, such as the RAID
level, size, and physical disk selection.
The Express wizard displays the RAID levels supported by the controller and
enables you to select the desired RAID level and the disk size for your
virtual disk. After you select the RAID level, the
Express wizard selects an appropriate physical disk given the size of the
physical disks and the available disk space. The Express wizard displays the
physical disks it has selected so that you can confirm the selection before
creating the virtual disk.
The Advanced wizard allows you to select physical disks and specify additional
virtual disk properties such as the read, write, and cache policies.
Figure 6: Screenshot of Create Virtual Disk Advanced Wizard with Disk Selection Displayed
The Create Virtual Disk Express and Create Virtual Disk Advanced wizards set
the virtual disk initialization to “Fast Initialize” by default. After
completing the creation of a virtual disk using the Express or Advanced
wizard, the PERC 5/E controller implements the virtual disk configuration on
the selected physical disks and completes a fast initialize.
Reconfiguring Virtual Disks — RAID Migration and Capacity Expansion
Server Administrator supports RAID migration and capacity expansion with the
Reconfigure Virtual Disk wizard. This wizard enables you to change a virtual
disk’s RAID level or increase its size by adding one or more physical disks.
The possibilities for reconfiguring a virtual disk depend on the capabilities
of the RAID controller, the existing RAID level, and the available physical
disks. The following table describes the possible reconfiguration scenarios on
the PERC 5/E controller.
Table 3: Virtual disk reconfiguration on the PERC 5/E RAID controller
PERC 5/Controller
Starting RAID Level
| Target RAID Level| Disk Requirements
---|---|---
RAID 0| RAID 0| Add at least one additional disk
RAID 0 (on a single disk)| RAID 1| Add a single disk
RAID 0| RAID 5| Add at least one additional disk
RAID 1| RAID 0| With or without adding additional disks
RAID 1| RAID 5| Add additional disks
RAID 5| RAID 0| With or without adding additional disks
RAID 5| RAID 5| Add additional disks
Other considerations may apply to virtual disk reconfiguration. For example,
you cannot create more than sixty four virtual disks on the PERC 5/E
controller. After reaching this limit, you will not be able to reconfigure any
of the virtual disks on the controller.
The Reconfigure Virtual Disk wizard displays the available target RAID levels
and the physical disks. After you have selected the new RAID level and the
physical disks, the Reconfigure Virtual Disk wizard displays the previous and
the new configuration so that you can confirm or reject the changes.
Moving Physical Disks and Virtual Disk Configurations – Disk Roaming and Disk
Migration
Disk roaming refers to physically moving a disk from one cable connection to
another or from one backplane or enclosure slot to another on the same
controller. The PERC 5/E controller recognizes the relocated physical disks
and logically restores the physical disk and its data to the proper virtual
disk. Disk roaming can be performed only when the system is shut down.
Disk migration refers to moving physical disks from one controller to another.
Virtual disks residing on the relocated physical disks are identified as a
foreign configuration on the receiving PERC 5/E controller. The Server
Administrator enables you to import the foreign configuration so that the
migrated virtual disks can be managed on the receiving PERC 5/E controller.
The following conditions must be met to successfully migrate the physical disks and their resident virtual disks:
- Virtual disks on a SAS controller can only be migrated to another SAS controller.
- When moving an enclosure, power down the enclosure and the server before moving the enclosure. The enclosure can be moved to any connector number on the receiving controller.
The following procedure describes how to migrate the physical disks from one controller to another:
- Shut down the system from which the physical disks are being moved.
- Shut down the server of the receiving controller if it does not have a preexisting virtual disk configuration.
- Place the physical disks into the new enclosure.
- Start up the system connected to the receiving controller.
- Use Server Administrator’s Import Foreign Configuration wizard to import the migrated virtual disks on the receiving controller.
Importing Migrated Virtual Disks
After migrating the physical disks, Server Administrator enables you to import
the virtual disks or “foreign” configuration that reside on the relocated
physical disks.
To be imported, the foreign configuration must contain a virtual disk that is
in either “Ready” or “Degraded” state. For proper completion of this task, all
of the virtual disk data must be present. If the virtual disk is using a
redundant RAID level, the additional redundant data does not need to be
present. For example, if the foreign configuration contains one side of a
mirror in a RAID 1 virtual disk, then the virtual disk is in a degraded state
and can be imported. On the other hand, if the foreign configuration contains
only one physical disk that was originally configured as a RAID 5 using three
physical disks, then the RAID 5 virtual disk cannot be imported.
In addition to the virtual disks, a foreign configuration may consist of a physical disk that was assigned as a hot spare on one controller and then moved to another controller. The Import Foreign Configuration wizard imports the new physical disk as a hot spare. If the physical disk was a dedicated hot spare on the previous controller, but the virtual disk to which the hot spare was assigned is no longer present in the foreign configuration, then the physical disk is imported as a global hot spare.
If a physical disk contains all or some portion of a foreign configuration, then Server Administrator displays the physical disk state as “Foreign.”
The Server Administrator displays the Import Foreign Configuration task when the controller detects a foreign configuration. If you have an incomplete foreign configuration which cannot be imported, using the Clear Foreign Configuration task, erases the foreign data on the physical disks.
Figure 8: Controller Tasks Drop-down Menu With the Import Foreign Configuration and Clear Foreign Configuration Tasks Displayed
Upgrading from Dell OpenManage Array Manager
Dell has discontinued the release of Dell OpenManage Array Manager. Server
Administrator is a replacement for Array Manager. Customers wishing to take
advantage of SAS technology must upgrade their Array Manager installation to
Server Administrator. Server Administrator also provides Linux support which
was not offered with Array Manager.
Note: OMSA: Server Administrator does not support NetWare. Existing
NetWare customers may continue to use their Array Manager licenses for
existing systems, but additional licenses will not be granted for new systems.
Note: Server Administrator does not provide support for Fibre channel arrays.
The following sections describe the considerations for upgrading to Server
Administrator.
Virtual Disk Preservation
You can preserve assigned virtual disk names when migrating from Array Manager
to Server Administrator. To do so, you must not uninstall Array Manager prior
to installing Server Administrator. If Array Manager is uninstalled prior to
installing Server Administrator, the virtual disks are renamed. Irrespective
of whether Array Manager is uninstalled, Server Administrator identifies and
manages the virtual disks created with Array Manager.
SNMP Traps
The architecture for handling SNMP traps and the Management Information Base
(MIB) is different in Server Administrator than in Array Manager. You may need
to modify the applications that are customized to receive SNMP traps from
Array Manager.
Event Numbering
The numbering scheme for Storage Management alerts or events is different than
the numbers used for the corresponding Array Manager events. See the Alert
Messages chapter in the Storage Management online help for more information.
Storage Applications and Components
Identify customer usage model and needs
In order to select the correct storage solution, it is important to understand
the application and user requirements. A good starting point is to use the
following basic storage profiling considerations.
Table 4: Storage Profiling Considerations
Characteristic | Values | Description |
---|---|---|
Performance | · Bandwidth (MB per sec.) |
· I/O size (KB/MB)
· I/O Profile (read/write and random/sequential access mix)
· Latency
| Performance is the overall ability of the solution to read and write data to the disk. The performance requirements are usually determined by the type of application being utilized. Different applications have different performance requirements. For example, a database or e-mail server has mostly random disk access operations while a streaming media server would have mostly
sequential disk access.
Storage Capacity Needs| Gigabytes| Storage capacity is the amount of storage space required by the application and user data. For example, e-mail storage for 100 users would require much less storage
capacity than an e-mail store for 1000 users.
Storage Growth Rate| Percent increase per year| Storage growth is the expected increase in the amount of the capacity that will be required as the usage increases. This can be estimated by forecasting the number of users or clients expected to access the
application in the future.
Criticality| Low, Medium, High, Very High| Criticality defines the impact to business needs if the storage is offline. This characteristic is important for choosing the right RAID level.
Picking a solution based on the application profile
One of the most important factors to consider when selecting a storage
solution is the type of application that will be utilizing the storage
solution. This defines the overall purpose of the server/storage solution and
will determine what RAID configuration will be optimal for the application.
Table 5 outlines the recommended RAID solution based on the usage of the
server.
Table 5: RAID Configuration Recommendations
General RAID Configuration Guidelines
RAID 0
RAID 0 is generally not a recommended solution due to lack of data redundancy
and protection.
However, it may be utilized in situations where this is not required and
maximum storage capacity and performance are essential.
RAID 1
A RAID 1 solution, while not ideal, could be utilized for small workgroup
servers or servers with low storage capacity and growth requirements. Any
server beyond a small workgroup server is likely to need more storage and
consequently, a more efficient RAID solution.
RAID 10
RAID 10 has good I/O performance, excellent availability and redundancy. The
biggest drawback of RAID 10 is that it requires twice the number of physical
disks needed for data. This RAID configuration should be used in situations
requiring maximum availability, redundancy, and performance.
RAID 5
RAID 5 has good I/O performance, data protection and requires only one
additional physical disk than the number needed for data. RAID 5 should be
used in situations where maximum storage capacity is required along with a
moderate amount of data protection.
RAID 50
A balance between RAID 5 and RAID 10, this solution offers good I/O
performance, availability and good storage capacity. This configuration offers
slightly higher performance than RAID 5, but requires multiple additional
physical disks than the number needed for data. It does however provide
greater storage capacity than a RAID 10 solution with a decrease in
performance and data protection. This should be used in situations where
greater redundancy and data protection is required as well as a reasonable
storage capacity.
Concatenated
This solution is not recommended due to lack of data protection and redundancy
and no performance gain.
Note: For more details on RAID configurations see the Dell ‘Getting Started
with RAID’ document
(http://support.dell.com/support/edocs/storage/RAID/RAIDbk0.pdf)
Application specific guidelines
E-Mail Servers
The storage requirements for e-mail servers can vary depending on the size,
the amount, and the type of users. While small departmental e-mail servers may
work well with a small amount of storage and limited features; large corporate
e-mail servers normally require greater storage capacity, very high
availability, performance, and scalability. I/O profiles will vary depending
on the number of users and type of mail and attachments sent.
Table 6: Email Server General I/O profile
I/O Profile
(Read/Write)
| I/O Profile
(Sequential/Random)
| Bandwidth| I/O Size| Latency Sensitivity| Growth Rate|
Criticality
---|---|---|---|---|---|---
60/40| Random| Heavy| 4k| High| High| High
Table 7: Email Sever RAID Guidelines
Recommended:
-
RAID 10 – Recommended for mission-critical e-mail servers where availability and redundancy and/or performance are the highest priority and where reduced storage capacity is acceptable.
-
RAID 5 – Recommended for e-mail servers that require maximum storage capacity and moderate data protection and performance.
-
RAID 50 – Recommended for those solutions that require greater redundancy and data protection and a balance between storage capacity and performance.
Possible: -
RAID 1 – Possible solution for small e-mail servers which do not require high storage capacity.
Not recommended: -
RAID 0, Concatenated – Not recommended due to lack of redundancy and data protection.
Note: While these configurations are not recommended, they can be configured and utilized.
Web Servers
Web severs are usually high traffic systems where read operations are the most
common disk activity as web pages are requested by users. They can be intranet
sites with minimal internal company traffic or global internet portal sites
that receive hundreds of thousands of users daily.
Performance is generally the main concern with redundancy and data protection
being less of a concern. For large web sites, there are usually several web
servers responding to client requests and as a result the need for redundancy
and data protection is not as important. Also web servers may not require as
much scalability or disk capacity since website content is relatively static
and changes are usually minor content modifications.
Table 8: Web General IO profile
I/O Profile
(Read/Write)
| I/O Profile
(Sequential/Random)
| Bandwidth| I/O Size| Latency Sensitivity| Growt h Rate|
Criticality
---|---|---|---|---|---|---
95/5| Random| Moderate| < 64k| Moderate| Low| High
Table 9: Web RAID Guidelines
Recommended:
- RAID 10 – Recommended for enterprise web server solutions where availability and redundancy and performance are the highest priority, usually for stand-alone portal sites that are critical to the organization’s business.
- RAID 5 – Recommended for web servers that require maximum storage capacity and moderate data protection and performance.
- RAID 50 – Recommended for those solutions that require a balance between storage capacity and performance.
- RAID 0 – Recommended for solutions where the web server will be part of a group of web servers that service a large internet portal and performance is the highest concern. In this situation, availability and redundancy are addressed by the cluster group and do not need to occur at the disk level.
- RAID 1 – Good solution for small websites which do not require high storage capacity.
Not recommended:
- Concatenated – This solution is not recommended due to lack of redundancy and data protection
Note: While this configuration is not recommended, it can be configured
and utilized.
Database or Online Transaction Processing Servers
Database servers can range from simple workgroup databases like Microsoft®
Access with a few hundred users to mission-critical enterprise databases like
Oracle or SQL Server with thousands of users. Database applications will
always benefit from some data protection while other requirements such as
performance and availability will vary. As a general rule, the more critical
the database, greater is the need for data protection. Additionally, the
performance requirements increase relative to the number of users accessing
the database.
Online Transaction Processing (OLTP) oriented servers are used in a number of
industries for the entry and retrieval of transactions. For example, OLTP is
common in banking, airlines, mail-order, and supermarkets. These servers are
generally mission-critical and require maximum availability and redundancy
possible.
Table 10: Database or OLTP General IO profile
I/O Profile
(Read/Write)
| I/O Profile
(Sequential/Random)
| Bandwidth| I/O Size| Latency Sensitivity| Growt h Rate|
Criticality
---|---|---|---|---|---|---
80/20| Random| Moderate| 8k| Moderate| Low| High
Table 11: OLTP RAID Guidelines
Recommended:
- RAID 10 – Since OLTP systems are critical for most business, this RAID configuration is highly recommended due to the high availability and redundancy and good performance.
- RAID 5 – Recommended for OLTP servers that require maximum storage capacity and moderate data protection and performance.
- RAID 50 – Recommended for those solutions that require a balance between storage capacity and performance.
Possible:
- RAID 1 – Possible solution for situations which do not require high storage capacity.
Not recommended:
- RAID 0 , Concatenated – These are not recommended due to lack of redundancy and data protection.
Note: While these configurations are not recommended, they can be configured and utilized
File Servers
File servers can be used for file archival or more dynamic storage where files
are changed, added and deleted on a daily basis. These servers range from
workgroup to the corporate level. Storage capacity is a key attribute of these
servers as users add more and more files. File servers are generally not
mission critical systems so lower levels of availability and redundancy are
acceptable as data is usually backed up and can be restored in a matter of
hours.
Archival file server characteristics and recommendations:
Table 12: Archival File Server General I/O profile
I/O Profile
(Read/Write)
| I/O Profile
(Sequential/Random)
| Bandwidth| I/O Size| Latency Sensitivity| Growt h Rate|
Criticality
---|---|---|---|---|---|---
90/10| Sequential| Moderate| >64k| High| Varies| Low
Table13: Archival File Server RAID Guidelines
Recommended:
- RAID 10 – Recommended due to high availability, redundancy, and good performance.
- RAID 5 – Recommended for file servers that require maximum storage capacity and moderate data protection and performance.
- RAID 50 – Recommended for those solutions that require a balance between storage capacity and performance.
Possible:
- RAID 1 – Possible solution in situations which do not require high storage capacity. Not recommended:
- RAID 0 , Concatenated – These are not recommended due to lack of redundancy and data protection. Even for long term archival storage which is intended to be a backup of important files, it is not a recommended solution.
Note: While these configurations are not recommended, they can be configured and utilized.
User file store characteristics and recommendations
Table 14: User Store File Server General IO profile
I/O Profile
(Read/Write)
| I/O Profile
(Sequential/Random)
| Bandwidth| I/O Size| Latency Sensitivity| Growt h Rate|
Criticality
---|---|---|---|---|---|---
80/20| Sequential| Heavy| >64k| High| Varies| Moderate
Table 15: User Store File Server RAID Guidelines
Recommended:
- RAID 5 – Recommended for file servers that require maximum storage capacity and moderate data protection and performance.
- RAID 50 – Recommended for those solutions that require a balance between storage capacity and performance.
Possible:
- RAID 1 – Possible solution for situations which do not require high storage capacity.
- RAID 10 – Possible solution for situations that require greater availability and redundancy but not as much disk capacity.
- RAID 0 – While this solution is not redundant, RAID 0 may be useful for file servers that require better performance and maximum storage capacity, for example, where backups are expected to maintain data in the event of a failure.
- Concatenated – This solution could be used for situations that require maximum scalability as physical disks could be added as storage needs grow. For file servers that can afford some downtime and rely on backups to restore data, this could be a solution.
Streaming Media Servers
Streaming media servers are systems that provide web-casting, video
conferencing, internet entertainment (e.g. Internet TV or Internet radio), and
multimedia services. These systems generally require a balance between storage
capacity, availability, redundancy, and performance.
Like web servers, they may also be part of a group of systems that work
together to provide content.
Table 16: Streaming Media IO profile
I/O Profile
(Read/Write)
| I/O Profile
(Sequential/Random)
| Bandwidth| I/O Size| Latency Sensitivity| Growt h Rate|
Criticality
---|---|---|---|---|---|---
98/2| Sequential| Heavy| >64k| High| High| Varies
Table 17: Streaming Media RAID Guidelines
Recommended:
-
RAID 5 – Recommended for streaming media servers that require maximum storage capacity and moderate protection and performance. This is the recommended RAID configuration for stand alone streaming media servers.
-
RAID 50 – Recommended for those solutions that require a balance between storage capacity and performance. This solution provides greater availability and redundancy but less storage capacity.
-
RAID 0 – While not redundant, this solution may be useful for streaming media servers that require better performance and are members of a cluster of servers where availability and redundancy are handled at a higher level.
Possible: -
RAID 1, RAID 10 – Possible in situations which do not require high storage capacity. In general servers utilized for streaming media require large amounts of storage capacity for content, especially uncompressed video.
Not Recommended: -
Concatenated – This solution is not recommended due to lack of redundancy and limited performance.
Note: While these configurations are not recommended, they can be configured and utilized.
Hot Spares
Hot Spare functionality provides extra security, availability and redundancy
by automatically replacing a failed physical disk in a RAID group and allowing
the rebuild of the degraded array to begin immediately. PERC 5/E controllers
support Hot Spare functionality and it is recommended whenever possible.
Summary and Conclusions
It is important to understand the characteristics of each storage component in order to assess the performance of the overall application. It is also necessary to understand how the storage component is configured since this has a direct impact on the effectiveness of an application. Table 8-1 summarizes typical storage recommendations for various applications. Recommendations listed in the table are general conclusions and the actual storage solution may have additional factors which need to be considered before determining an optimal solution. Additional factors could include:
- Data and power back-up strategies of an Enterprise IT
- Storage deployment environment:
- Number of active and passive users
- Type of data – mission-critical or non-mission-critical
- Storage deployment budget
- Long term storage consolidation strategy
Table 18: Typical Storage Recommendation for Different Storage Applications
Application | Storage Recommendations | Remarks |
---|---|---|
Servers | Key Parameters | RAID Level |
Controller_
Email| Availability Performance Scalability| RAID 10 provides both
availability and performance| Daisy-chaining provides capacity scalability|
For added performance enable Write back cache| Recommendation targets a
typical enterprise e-mail Server
Database| Availability| RAID 10 provides| Daisy-chaining| For added|
Performance
| Performance| both availability and performance| provides capacity
scalability| performance enable Write back cache| requirements for database
servers depend on number of users
---|---|---|---|---|---
Web| Performance| RAID 0 in Web Server farms provides maximum performance
of all RAID levels| Split Topology spanning RAID 0 across channels provides
better performance if daisy-chaining for additional capacity
is not required
| Enable read ahead capabilities for added performance boost| Web server
farms, usually have multiple servers providing replicated web data. Thus, data
availability is handled at server level
On-line Transaction| High Availability| RAID 10
provides highest availability of all RAID levels
| Daisy-chaining provides capacity scalability| For added performance enable Write back cache| Recommendation targets Enterprise applications which require higher availability than performance.
In general for all OLTP, data protection is of
utmost importance
File| Scalability| RAID 5
maximizing storage with some data protection
| Daisy-chaining provides capacity scalability| Enable Global Hot Spare for improved availability for RAID 5| These servers usually have data backed up periodically and hence, require minimum data
protection from storage components
Streaming Media| Performance| RAID 0
provides maximum performance of all RAID levels
| Split Topology spanning RAID 0 across channels provides better performance if daisy-chaining for additional capacity
is not required
| Enable read ahead capabilities for added performance boost| Performance is of utmost importance for Streaming servers. Data on these servers is usually backed up on external media such as tape libraries or optical media – CD/DVD
Appendix – A: References
-
SAS Protocol Specification
(http://www.t10.org/drafts.htm#SCSI3_SAS) -
SFF-8470 Connector Specification
(http://www.sffcommittee.com/ns/index.html) -
Beyond The 2-TB SCSI Logical Unit
(http://www.dell.com/downloads/global/vectors/2004_2tblun.pdf)
Appendix – B: Glossary
- Array – Collection of multiple physical disks to form a single logical volume
- BBU – Battery Backup Unit
- BIOS – Basic Input Output System
- Cluster – Multi-initiator Environment with MSCS operating environment
- HBA – Host Bus Adapter (non-RAID controllers)
- Hot Plug – Insertion or removal of device without the need to quiescent I/Os
- PERC – PowerEdge Expandable RAID Controller
- RAID – Redundant Array of Inexpensive Disks or Redundant Array of Independent Disks
- SAS – Serial Attached SCSI
- SCSI – Small Computer System Interface
- U320 – Ultra 320 (320MB/sec through put)
Appendix – D: Revision History
Revision | Description | Date | Modified By |
---|---|---|---|
A00 | First Release | 4/17/2006 | SAS Solution Core Team |
References
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>