Please read this instruction manual carefully before installation and first use, and store it in a safe place. If you pass on the product to another person, hand over this instruction manual along with it.

Explanation of symbols

DANGER!
Safety instruction : Failure to observe this instruction will cause fatal or serious injury.

WARNING!
Safety instruction : Failure to observe this instruction can cause fatal or serious injury.

NOTICE!
Failure to observe this instruction can cause material damage and impair the function of the product.

NOTE
Supplementary information for operating the product.

General safety instructions

General safety

The manufacturer accepts no liability for damage in the following cases:

  • Faulty assembly or connection
  • Damage to the product resulting from mechanical influences and excess voltage
  • Alterations to the product without express permission from the manufacturer
  • Use for purposes other than those described in the operating manual

Note the following basic safety information when using electrical devices to protect against:

  • Electric shock
  • Fire hazards
  • Injury

General safety

DANGER!

  • In the event of fire, use a fire extinguisher which is suitable for electrical devices.

WARNING!

  • Only use the device as intended.
  • Ensure that the red and black terminals never come into contact.
  • Disconnect the device from the mains:
    • Before cleaning and maintenance
  • If you disassemble the device:
    • Detach all connections
    • Make sure that no voltage is present at any of the inputs and outputs
  • The device may not be used if the device itself or the connection cable are visibly damaged.
  • If the power cable for this device is damaged, it must be replaced by the manufacturer, customer service or a similarly qualified person in order to prevent safety hazards.
  • This device may only be repaired by qualified personnel. Inadequate repairs may cause serious hazards.
  • This device can be used by children aged 8 years or over, as well as by persons with diminished physical, sensory or mental capacities or a lack of experience and/or knowledge, providing they are supervised or have been taught how to use the device safely and are aware of the resulting risks.

Electrical devices are not toys.

  • Always keep and use the appliance out of the reach of children.
  • Children must be supervised to ensure that they do not play with the device.

NOTICE!

  • Before start-up, check that the voltage specification on the type plate is the same as that of the power supply.
  • Ensure that other objects cannot cause a short circuit at the contacts of the device.
  • Never pull the plug out of the socket by the connection cable.
  • Store the device in a dry and cool place.

Safety when installing the device

DANGER!

  • Never mount the device anywhere where there is a risk of gas or dust explosion.

!CAUTION!

  • Ensure that the device is standing firmly.
  • The device must be set up and fastened in such a way that it cannot tip over or fall down.

NOTICE!

  • Do not expose the device to a heat source (such as direct sunlight or heating). Avoid additional heating of the device in this way.
  • Set up the device in a dry location where it is protected against splashing water

Safety when connecting the device electronically

  • DANGER! Danger of electrocution

    • If you are working on electrical systems, ensure that there is somebody close at hand who can help you in emergencies.
  • WARNING!

    • Make sure that the lead has a sufficient cross-section.
    • Lay the cables so that they cannot be damaged by the doors or the bonnet.
      Crushed cables can lead to serious injury.
  • CAUTION!

    • Lay the cables so that they cannot be tripped over or damaged.
  • NOTICE!

    • Use ductwork or cable ducts if it is necessary to lay cables through metal panels or other panels with sharp edges.
    • Do not lay the 230 V mains cable and the 12 V DC cable in the same duct.
    • Do not lay the cable so that it is loose or heavily kinked.
    • Fasten the cables securely.
    • Do not pull on the cables.

Operating the device safely

  • DANGER! Danger of electrocution
    • Do not touch exposed cables with your bare hands.

WARNING!

  •  Only use the device in closed, well-ventilated rooms.

CAUTION!

  • Do not operate the device
    • In salty, wet or damp environments
    • In the vicinity of corrosive fumes
    • In the vicinity of combustible materials
    • In areas where there is a danger of explosions.
  • Before starting the device, ensure that the power supply line and the plug are dry.
  • Always disconnect the power supply when working on the device.
  • Please observe that parts of the device may still conduct voltage even if the fuse has blown.
  • Do not disconnect any cables when the device is still in use.

NOTICE!

  • Make sure the air inlets and outlets of the device are not covered.
  • Ensure good ventilation.

Scope of delivery

Accessories

The target group for this manual

The electrical installation (chapter “Connecting the inverter” on page 14) is intended for professionals who are familiar with the applicable regulations of the country in which the equipment is to be installed and/or used.

All other chapters are intended for the users.

Intended use

WARNING!

  • Never use the inverter on vehicles where the positive terminal of the battery is connected to the chassis.

The wave inverter converts direct current into a 230 – 240 V AC supply of 50 Hz or 60 Hz:

  • 12 Vg : DSP1312T, DSP1812T, DSP2312T, DSP3512T
  • 24 Vg : DSP1324T, DSP1824T, DSP2324T, DSP3524T

Technical description

The inverters can be operated wherever a DC connection is available:

  • 12 Vg : DSP1312T, DSP1812T, DSP2312T, DSP3512T
  • 24 Vg : DSP1324T, DSP1824T, DSP2324T, DSP3524T
  • The lightweight and compact construction of this device allows for easy installation in mobile homes, commercial vehicles or motor and sailing yachts.
  • The output voltage corresponds to the household voltage from the socket (pure sine wave, THD < 3 %).

Please observe the values for constant output power and peak output power as indicated in the chapter “Technical data”. Never connect devices that have a higher power requirement.

NOTE

  • Note when connecting devices with an electrical drive (such as power drills and refrigerators), that they often require more power than is indicated on the type plate.

The inverter has various protective mechanisms.

  • Overvoltage shutdown : The inverter shuts itself off when the voltage exceeds the cut-off value. It restarts when the voltage returns to the restart value.
  • Undervoltage shutdown : The inverter shuts itself off when the voltage sinks below the cut-off value. It restarts when the voltage rises to the restart value.
  • Excess temperature shutdown : The inverter switches off when the temperature inside the device or the temperature on the cooling element exceeds a cutoff value. It restarts when the voltage rises to the restart value.
  • Overloading and short circuit shutdown : The LED on the inverter indicates an operating fault when an excess load is connected or a short circuit has occurred. The fuse in the device must be pressed in again by hand after it is triggered by excess current.

NOTE :The individual values are found in the chapter “Technical data”

The inverter can be operated in the following network configurations:

  • TN network: The neutral conductor of the inverter is grounded. A downstream safety switch (RCD) must be installed.
  • IT network : Both phases are insulated. This is suitable for operating one load. If more than one load will be connected a protection plan has to be set up (e. g. insulation monitor).

The network configuration is set via a DIP switch at the device.
The inverters DSP13xxT, DSP18xxT, and DSP23xxT have a connection cable with a socket and plug. The inverter DSP35xxT is directly connected at the terminals via the PG glands.
Due to the phase synchronisation, the inverter adapts to the phase of the AC input voltage. Thereby voltage peaks are prevented when switching from battery to mains.

The inverter is suitable for operating sensitive consumers because the output voltage is a pure sinus wave.
The inverter is fitted with a priority circuit. If an external 230 Vw voltage is available,this will have priority. If no external 230 Vw voltage is connected, then the connected battery will be used as the power supply.

The inverter can be switched to an energy-saving mode to prevent the connected battery from discharging too quickly.
The inverter can be turned on or off using the remote control (accessory).
Additionally, the inverter can be controlled using the energy monitor (accessory).

Control elements

DOMETIC-DSP3524T-Sine-Power-Comfort-fig278

Connections

NOTE: The version for continental Europe is depicted.

Fitting the inverter

NOTE : Before fitting the inverter, you should connect all cables because all connections are freely accessible.

Tools required

For the electrical connection you will need the following tools:

  • Crimping tool
  • 3 multi-coloured, flexible connection cables. Determine the necessary thickness from the table in chapter “Connecting the inverter”.
  • Cable lugs and conductor sleeves

For fastening you will require the following tools:

  • Machine bolts (M4) with washers and self-locking nuts or self-tapping screws or wood screws.

Mounting instructions

When selecting the installation location, observe the following instructions:

  • The inverter can be mounted horizontally or vertically.
  • The inverter must be installed in a place that is protected from moisture.
  • The inverter may not be installed in the presence of flammable materials.
  • The inverter may not be installed in a dusty environment.DOMETIC-DSP3524T-Sine-Power-Comfort-fig20
  • The place of installation must be well-ventilated. A ventilation system must be available for installations in small, enclosed spaces. The minimum clearance around the inverter must be at least 5 cm (fig.3).
  • The ventilation holes on the front and back of the inverter must remain clear.
  • For ambient temperatures higher than 40 °C (such as in engine or heating compartments, or direct sunlight), the inverter may shut down although the connected load is below the rated load (derating).
  • The device must be installed on a level and sufficiently sturdy surface.

NOTICE! Before drilling any holes, make sure that no electrical cables or other parts of the vehicle can be damaged by drilling, sawing and filing.

Mounting the inverter

DOMETIC-DSP3524T-Sine-Power-Comfort-fig21

  • Mount the inverter as shown (fig.4).

Connecting the inverter

  • General instructions

WARNING!

  • The inverter may only be connected by a qualified workshop. The following information is intended for technicians who are familiar with the guidelines and safety precautions to be applied.

  • Never use the inverter on vehicles where the positive terminal of the Battery is connected to the chassis.

  • If you do not fit a fuse to the positive cable, the cables can overload, which might result in a fire.

  • When installed in vehicles or boats, the inverter must be connected to the chassis or earth.

  • When setting up a socket distribution circuit (mains setup), comply with the applicable regulations.

  • Only use copper cables.

  • Keep the cables as short as possible (< 1 m).

  • For grounding use a cable with a minimum cross section of 4 mm².

  • Keep to the specified cable cross-section and fit a cable fuse (fig.6) as close to the battery as possible on the positive cable (see the table).

Connecting the inverter

WARNING!

  • Before connecting the AC output cable, make sure the inverter is switched off at the main switch.

NOTICE!

  • Make sure that you do not reverse the polarity. Incorrect polarity can damage the inverter.

NOTE

  • Tighten the nuts and bolts to a maximum torque of 15 Nm. Loose connections may cause overheating.

Connect the inverter as shown:

  • Connecting the battery : fig.5 and fig.6
  • Connecting the ground terminal fig.7
  • Connecting the 230 V power cable : fig.8 (INPUT)
  • Connecting the 230 V output cable : fig.8 (OUTPUT

Connecting multiple appliances

The device is equipped at delivery with galvanic isolation. For the safe operation of multiple appliances, a circuit breaker (residual current circuit breaker) must be built into the socket distribution circuit.
Install a residual current circuit breaker in the socket distribution circuit.

Connecting the remote control (accessory)

NOTICE! Only plug in the connection to the remote control in the remote port. The device can be damaged by connecting it incorrectly.

  • Connect the remote control as shown (fig.9).

Connecting the external switch to turn the device on and off

NOTE

  • Use cables with a cable cross-section of 0.25 – 0.75 mm².

You can use the following as an external switch:

  • External switch, voltage supply from the inverter : fig.10A
  • Control unit with relay or transistor circuit (TR): fig.10B
  • External switch with a voltage supply from the battery (BAT) of the vehicle : fig.10C
  • External switch with its own voltage supply (DC POWER) e.g. from the ignition: fig.10D
  • Set the main switch (fig.2(1) to “OFF”.
  • Make sure that the connection for the remote control (fig.2,.(11) is not assigned.
  • Set the main switch (fig.(21) to “REMO.”.
  • Connect the external on/off switch with the connection cable to the terminal (fig.2(12).

Connecting the fault display relay

You can install a relay that monitors whether the 230 V input is connected. Thereby you can, for example, implement an immobiliser so that the vehicle cannot be started when the 230 V input is connected.

  • Connect the relay as shown (fig.11):
    • NO : normally open contact
    • COM : common contact
    • NC : normally closed contact

Relay specification:

Using the inverter

Switching on the inverter

Set the main switch (fig.2(1) of the inverter as follows:

  • * “0”: to switch the inverter permanently off
    • “I”: to switch the inverter permanently on

    • “II”: to switch the inverter on and off with a remote control (accessory)
      The inverter performs a self-test when starting.

    • ✓ After the self-test is completed successfully, the LED lights up blue (fig.2(2).

Status indications

The blue LED (fig.2(2) shows the operating condition of the inverter.

The inverter switches off if:

  • The battery voltage drops below 10 V (12 Vg connection) or 20 V (24 Vg connection).
  • The battery voltage exceeds 16.5 V (12 Vg connection) or 33 V (24 Vg connection).
  • The inverter is overloaded.
  • The inverter overheats.

If this happens, shut down the inverter with the main switch (fig.2(1).
Check that the inverter is sufficiently ventilated and that the ventilation grilles are unimpeded.
Wait 5 – 10 minutes and switch the inverter on again without any electric consumers.

Switching to energy-saving mode

NOTE: The energy-saving mode can be set with a remote control only.

Configuring the inverter

You can adjust the device using the DIP switch (fig.2(4).

Defining settings

Using the S1 dip switch you can define whether the parameter of the setting should be made using the connection of a CI BUS capable control panel or the dip switches.

Setting the mains voltage

You can set the mains voltage using the S2 dip switch.

Switching to energy-saving mode

  • You can set the energy-saving mode using the S3 and S4 dip switches. In this way, the battery you connect to the inverter is not discharged as quickly.
  • The inverter operates in energy-saving mode as long as the required power is below the set level. If the required power exceeds the set level, the inverter works in normal mode.

The values to be set on your inverter can be found in the following table:

Setting net configuration

Using the S5 dip switch you can define in which net configuration the inverter shall operate.

Cleaning and caring for the inverter

NOTICE! Do not use sharp or hard objects or cleaning agents for cleaning as these may damage the product

  • Occasionally clean the product with a damp cloth.

Troubleshooting

  • WARNING! Do not open the device. You risk sustaining an electric shock by doing this.
  • NOTE If you have detailed questions on the specifications of the inverter please contact the manufacturer (addresses on the back of the instruction manual).

The LED (fig.22) indicates the fault:

Warranty

The statutory warranty period applies. If the product is defective, please contact the manufacturer’s branch in your country (see the back of the instruction manual for the addresses) or your retailer.
For repair and guarantee processing, please include the following documents when you send in the device:

  • A copy of the receipt with purchasing date
  • A reason for the claim or description of the fault

Disposal

➤ Place the packaging material in the appropriate recycling waste bins wherever possible.

If you wish to finally dispose of the product, ask your local recycling centre or specialist dealer for details about how to do this in accordance with the applicable disposal regulations

Technical data

DOMETIC-DSP3524T-Sine-Power-Comfort-fig15

Protective devices

Overvoltage shutdown

Undervoltage shutdown

For the current EU declaration of conformity for your device please refer to the respective product page on dometic.com or contact the manufacturer directly.

Contacts

AUSTRALIA

  • Dometic Australia Pty. Ltd.
  • 1 John Duncan Court
  • Varsity Lakes QLD 4227
  • 1800 212121
  • +61 7 55076001
  • Mail : sales@dometic.com.au

AUSTRIA

  • Dometic Austria GmbH
  • Neudorferstraße 108
  • A-2353 Guntramsdorf
  • +43 2236 908070
  • +43 2236 90807060
  • Mail : info@dometic.at

BRAZIL

  • Dometic DO Brasil LTDA
  • Avenida Paulista 1754, conj. 111
  • SP 01310-920 Sao Paulo
  • +55 11 3251 3352
  • +55 11 3251 3362
  • Mail : info@dometic.com.br

DENMARK

  • Dometic Denmark A/S
  • Nordensvej 15, Taulov
  • DK-7000 Fredericia
  • +45 75585966
  • +45 75586307
  • Mail : info@dometic.dk

HONG KONG

  • Dometic Group Asia Pacific
  • Suites 2207-11 · 22/F · Tower 1
  • The Gateway · 25 Canton Road,
  • Tsim Sha Tsui · Kowloon
  • +852 2 4611386
  • +852 2 4665553
  • Mail : info@waeco.com.hk

ITALY

  • Dometic Italy S.r.l.
  • Via Virgilio, 3
  • I-47122 Forlì (FC)
  • +39 0543 754901
  • +39 0543 754983
  • Mail : vendite@dometic.it

JAPAN

  • Dometic KK
  • Maekawa-Shibaura, Bldg. 2
  • 2-13-9 Shibaura Minato-ku
  • Tokyo 108-0023
  • +81 3 5445 3333
  • +81 3 5445 3339
  • Mail : info@dometic.jp

MEXICO

  • Dometic Mx, S. de R. L. de C. V.
  • Circuito Médicos No. 6 Local 1
  • Colonia Ciudad Satélite
  • CP 53100 Naucalpan de Juárez
  • Estado de México
  • +52 55 5374 4108
  • +52 55 5393 4683
  • Mail : info@dometic.com.mx

NETHERLANDS

  • Dometic Benelux B.V.
  • Ecustraat 3
  • NL-4879 NP Etten-Leur
  • +31 76 5029000
  • +31 76 5029019
  • Mail : info@dometic.nl

NEW ZEALAND

NORWAY

  • Dometic Norway AS
  • Østerøyveien 46
  • N-3232 Sandefjord
  • +47 33428450
  • +47 33428459
  • Mail : firmapost@dometic.no

POLAND

  • Dometic Poland Sp. z o.o.
  • Ul. Puławska 435A
  • PL-02-801 Warszawa
  • +48 22 414 3200
  • +48 22 414 3201
  • Mail : info@dometic.pl

PORTUGAL

  • Dometic Spain, S.L.
  • Branch Office em Portugal
  • Rot. de São Gonçalo nº 1 – Esc. 12
  • 2775-399 Carcavelos
  • +351 219 244 173
  • +351 219 243 206
  • Mail : info@dometic.pt

RUSSIA

  • Dometic RUS LLC
  • Komsomolskaya square 6-1
  • RU-107140 Moscow
  • +7 495 780 79 39
  • +7 495 916 56 53
  • Mail: info@dometic.ru

SINGAPORE

  • Dometic Pte Ltd
  • 18 Boon Lay Way 06–140 Trade Hub 21 Singapore 609966
  • +65 6795 3177
  • +65 6862 6620
  • Mail: dometic@dometic.com.sg

SOUTH AFRICA

  • Dometic (Pty) Ltd.
  • Regional Office
  • South Africa & Sub-Saharan Africa 2 Avalon Road
  • West Lake View Ext 11 Modderfontein 1645
  • Johannesburg
  • +27 11 4504978
  • +27 11 4504976
  • Mail: info@dometic.co.za

SPAIN

  • Dometic Spain S.L.
  • Avda. Sierra del Guadarrama, 16
  • E-28691 Villanueva de la Cañada Madrid
  • +34 91 833 60 89
  • +34 900 100 245
  • Mail: info@dometic.es

SWEDEN

  • Dometic Scandinavia AB
  • Gustaf Melins gata 7 S-42131 Västra Frölunda
  • +46 31 7341100
  • +46 31 7341101
  • Mail: info@dometicgroup.se

SWITZERLAND

  • Dometic Switzerland AG
  • Riedackerstrasse 7a CH-8153 Rümlang
  • +41 44 8187171
  • +41 44 8187191
  • Mail: info@dometic.ch

UNITED ARAB EMIRATES

  • Dometic Middle East FZCO
  • P. O. Box 17860
  • S-D 6, Jebel Ali Freezone

Dubai

UNITED KINGDOM

  • Dometic UK Ltd.
  • Dometic House, The Brewery
  • Blandford St. Mary Dorset DT11 9LS
  • +44 344 626 0133
  • +44 344 626 0143
  • Mail: customerservices@dometic.co.uk

USA

  • Dometic RV Division
  • 1120 North Main Street Elkhart, IN 46515
  •  +1 574-264-2131

GERMANY

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>

Related Manuals