DELTA DOP eRemote Industrial Automation Headquarters User Manual
- June 12, 2024
- Delta
Table of Contents
DELTA DOP eRemote Industrial Automation Headquarters
User Information
Be sure to store this manual in a safe place.
Due to constantly growing product range, technical improvement and alteration
or changed texts, figures and diagrams, we reserve the right of this manual
contained information change without prior notice.
Coping or reproducing any part of this manual, without written consent of
Delta Electronics Inc. is prohibited.
Technical Support and Service
Welcome to contact us or visit our web site
(http://www.delta.com.tw/industrialautomation/ ) if you need any technical
support, service and information, or, if you have any question in using the
product. We are looking forward to serve you needs and willing to offer our
best support and service to you. Reach us by the following ways.
ASIA
DELTA ELECTRONICS, INC.
TAOYUAN Plant/
31- 1, SHIEN PAN ROAD, KUEI SAN
INDUSTRIAL ZONE TAOYUAN 333, TAIWAN
TEL: 886- 3- 362- 6301
FAX: 886- 3- 362- 7267
NORTH/ SOUTH AMERICA
DELTA PRODUCTS CORPORATION
Sales Office/
P.O. BOX 12173
5101 DAVIS DRIVE,
RESEARCH TRIANGLE PARK, NC 27709,
U.S.A.
TEL: 1- 919- 767- 3813
FAX: 1- 919- 767- 3969
JAPAN
DELTA ELECTRONICS (JAPAN) INC.
Sales Office/
DELTA SHIBADAIMON BLDG.
2- 1- 14 SHIBADAIMON, MINATO- KU,
TOKYO, 105- 0012, JAPAN
TEL: 81- 3- 5733- 1111
FAX: 81- 3- 5733- 1211
EUROPE
DELTRONICS (NETHERLANDS) B.V.
Sales Office/
DE WITBOGT 15, 5652 AG EINDHOVEN,
THE NETHERLANDS
TEL: 31- 40- 259- 2860
FAX: 31- 40- 259- 2851
Introduction
eRemote Remote Control Software
eRemote is a PC software used to help the customers view and check the same
screen shown on HMI at the production site, and control the manufacturing
process via Ethernet. No matter where you are, remote controlling is not an
arduous task at all.
Supported Models
The supported models for eRemote Remote Control Software are listed in the table below.
Series | Model Name | Remark |
---|---|---|
DOP- AE Series | DOP- AE57BSTD | DOP series Ex tension Ethernet Module, DOP- |
EXLNHJ1AE is required when using eRemote with DOP- AE series HMI product.
DOP- AE57GSTD
DOP- AE57CSTD
DOP- AE80THTD1
DOP- AE10THTD1
DOP- B Series| DOP- B03E211|
DOP- B07E415
DOP- B07E515
DOP- B08E515
DOP- B10E615
System Requirement
Below are the system requirements to comply with the operating environment of eRemote:
Hardware / Soft ware | Syst em Requirement |
---|---|
CPU | Pent ium 4 , 2GHz or greater is recommended |
Memory | 1GB and above is recommended |
Hard Disk | Capacity: 50MB and above |
Monitor | Support resolution: 1024 × 768 or higher full- color display. |
Print er | Print er compatible with Windows® 2000 & Windows® XP |
Operation System | Windows 2000 / WindowsXP/ Windows Vista/ Windows7 |
Software Installation
eRemote Setup
In this chapter, it will introduce general functions of eRemote with Windows. The users can use it to design what they want. Detail information for each function will be discussed in the following chapters.
Software Installation
To start the eRemote setup, please refer to the following steps:
Step 1. Please start- up your computer to Windows 2000/ WindowsXP system.
Step 2. Execute setup.exe from Windows taskbar by clicking “Start” > “Run”.
After pressing OK, the system will setup automatically and the following
dialog box will appear for selecting the desired display language.
Step 3. After pressing OK, the system will setup automatically and the users
will get the following dialog box to choose destination location.
To select the default directory
C: \ Program Files\ Delta Industrial Automation\ DOP eRemote 2.xx.xx, click
Next> for the next step. Setup will install in the directory indicated in the
Destination Directory box at the bottom of the dialog box.
To select a directory other than the default directory, click Browse. A list
of available directories appears. Highlight the desired directory for the
Delta eRemote and click OK, then Next> for the next step.
If necessary, click < Back button to take you back through Setup dialog boxes
one by one.
Step 4. After pressing Next, the following dialog box will appear and ask the
users to select the installation software, i.e. DOP eRemote. Then click
Install button to start DOP eRemote installation.
Step 5. The system will start DOP eRemote Installation.
Step 6. DOP eRemote has been installed successfully. Press Close to finish the
installation.
Working with eRemote
Before using eRemote, the users need to update HMI firmware. Please ensure to read the following instructions fully so that the users could understand how to update HMI firmware correctly.
Update Firmware
Remember to update the firmware before using eRemote. To select this function,
click Start > Programs > Delta Industrial Automation > HMI > DOP eRemote
2.xx.xx > Update Firmware Tool.
After clicking Update Firmware Tool, the following dialog box will appear for
the users to select the communication interface (the default setting is USB
driver). Press Update button to update HMI firmware automatically.
Start eRemote
To start eRemote, click Start > Programs > Delta Industrial Automation > HMI >
DOP eRemote 2.xx.xx > eRemote.
Connection
After starting eRemote, click Connection > New from menu bar to create a new
connection.
The following IP Address Setup dialog box will appear, and the system will
search and show all of the connecting HMIs via Etherent automatically. Select
the desired HMI and press OK button.
User could type domain name to connect with eRemote.
Before connection, the password is required. Please enter the correct password
and press OK button.
After entering the correct password, the system will start the connection automatically. After the connection is successfully established, the users can monitor and control HMI screens on the computer screen.
Menu Reference
eRemote provide three options function menu for Connection, Zoom, Tool and Help.
And, also provide user to select icon to execute 【 New Connection 】 , 【 Close Connection】、【 Zoom In】、【 Zoom Out】、【 Full Screen】 【 Help】.
Connection
Function
Create Remote Control Connection
New| Create a new connection
Close| Close the current connection
Language| Select the display language. It supports Traditional Chinese,
Simplified Chinese and English.
Exit| Exit the eRemote
Zoom
Function
Determine the view of the eRemote screen
Zoom in
| Increase the magnification of the screen. The largest magnification available is 300%.
Zoom out
| Reduce the magnification of the screen. The smallest magnification available
is 25%.
Full Screen| Set the Screen to Full Screen as monitor.
Press right key of mouse to select 【Zoom in】、【Zoom out】 or 【Reset 】to cancel
the full screen.
Zoom reset| Reset the magnification of the screen to 100%.
Tool
Function
About print screen
Print Screen| Print screen function could provide user print currently remote
screen.
HTTP| This function could use web page to remote HMI.
Step1. Into Tool and select HTTP.
Step2. Check Enable HTTP. The Port default value is 80. When open each web
page, the port should set different. If start the first web page, the port is
81, then start the second web page, the port should set to be 82.
Step3. After setting, please start browser and type IP address of PC like
http:/ 172.16.190.54:81。User could check your PC IP address at command window,
type ipconfig to check current IP address.
Step4. Please type http:/172.16.190.54:81 on browser, if user could see as
below screen it means connect successful.
Please type password, the default password is 12345678. After typing correct
password, press Login, user could use web page to control HMI.
If type correct IP address of PC, but it still cannot connect, please turn of
the proxy of PC and reconnect again.
| It will appear as below message when HTTP service cannot start. Please check
the port if conflict or not.
Help
Function
About eRemote
About| Show the various items of legal information of eRemote.
Appendix A Testing Example
Before creating testing example, make sure to change the upload and download option (Options > Configuration) on DOPSoft first. The default setting of upload and download is via USB. If the users need to use Ethernet, please change the default setting by referring to Appendix B.
Networking Settings
Ensure to observe the following instructions to complete PC networking
settings before eRemote operation.
Power on PC and start Windows. Click Start > Programs, point to Control Panel,
and then select Network Connections.
Double- click Network Connections icon, the following windows will appear.
Right- click the Local Area Connection icon, and then select Properties from
the pop- up menu.
The Local Area Connection Properties dialog box will open. Use General tab to
select Internet Protocol (TCP/ IP). Then, press Properties button.
The Internet Protocol (TCP/ IP) Properties dialog box will open. Choose Use
the following IP address and enter the IP address numbers of the PC into the
field of IP address and Subnet mask.
Then, press OK button to finish the settings.
Please note that if the IP address numbers of subnet masks of the PC and HMI
are different, HMI may not be displayed in the list when finding node.
Create Testing Example
Start DOPSoft Software program and click File > New or click New icon to
create a new project. Then, click Element > Button > Maintained to create a
Maintained element ($0.0) and click Element > Input > Numeric Entry to create
a numeric entry element ($10) on the screen. In this case, 10 inches color
B10E615 type DOP series HMI is used.
Click Options > Communication Setting and choose Ethernet tab then select
LocalHost and complete HMI networking settings and Enable Network shown as the
figure below. Then, press OK button to finish the settings.
After OK button is pressed, HMI networking is completed. Compile the edited
project file at the end of the programming and the edited project file could
be transferred to HMI.
Then, start the eRemote and click Connection > New from menu bar to create a
new connection. The following IP Address Setup dialog box will appear, and the
system will search and show all of the connecting HMIs via Etherent
automatically. Select the HMI and IP Address is 172.16.190.51 then press OK
button.
After selected HMI, eRemote will asking user to input password to create
connection. The default password is 12345678.
At this time, the users are able to monitor and control HMI screens on the
computer screen.
Appendix B Upload / Download via Ethernet
Environment Settings
The default setting of upload and download on DOPSoft is via USB. If the users
need to use Ethernet, please activate DOPSoft and select Options > Environment
to access the configuration options and change the upload and download
setting.
In Environment dialog box, change the default setting of upload and download
to Ethernet.
Then, press OK to complete the setting.
Communication Setting
If the users choose to use DHCP mode, please into Options > Communication
Setting > Ethernet > LocalHost to enable Obtain an IP address automatically.
If the users choose to use user- defined IP address, please into Options >
Communication Settings > Ethernet > LocalHost and set HMI IP Address then
ensure that the domain name is the same as the IP address of the personal
computer.
After Ethernet IP address is set, the users can enter into the system menu to
verify if the IP address is written correctly or not.
Then, observe the following instructions to complete PC networking settings.
Power on PC and start Windows. Click Start > Programs, point to Control Panel,
and then select Network Connections.
Double- click Network Connections icon, the following windows will appear.
Right- click the Local Area Connection icon, and then select Properties from
the pop- up menu.
The Local Area Connection Properties dialog box will open. Use General tab to
select Internet Protocol (TCP/ IP). Then, press Properties button.
The Internet Protocol (TCP/ IP) Properties dialog box will open. Choose Use
the following IP address and enter the IP address numbers of the PC into the
field of IP address and Subnet mask.
Then, press OK button to finish the settings.
Please note that if the IP address numbers of subnet masks of the PC and HMI
are different, HMI may not be displayed in the list when finding node.
Compile and Upload / Download All Data
After completing PC networking settings, compile the editing program
immediately. When compile operation is performed successfully, choose Upload
all Data or Download all Data next.
Then, the following dialog box will appear.
The users can check the box before Auto Search, and the system will detect the
connecting HMI automatically.
When the connecting HMI is found, press Start button, and the system will start to upload or download the screen data via Ethernet immediately.
References